885 resultados para customized treadmill


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technical complications in implant prosthetic cases represent a major challenge in dentistry. This case report describes minimally invasive management to recover an implant with a fractured remnant of a zirconia abutment, including provisional rehabilitation during a sequential treatment protocol in the esthetic zone. A patient was treated with a screw-retained one-piece implant-supported reconstruction made of a customized zirconia abutment with direct ceramic veneering in the maxillary right central incisor position. During the prosthetic try-in, a fracture in the apical portion of the abutment was evident. The first rescue attempt led to fracture of the retrieval instrument. Immediately, an individualized wired construction was applied to bond the existing fractured reconstruction to the neighboring teeth to maintain the peri-implant mucosal architecture. Because the implant screw canal was blocked, a customized round bur had to be manufactured and was placed in the implant axis with a specific bracket tool from the service set to protect the interior implant threads. Then, the drills of the service set were guided by the newly created access to remove the fractured remnants. The implant screw was retapped and the area rinsed with chlorhexidine solution. All remnants were removed without the need for surgical intervention. Neither the implant connection nor the bone-to-implant interface was damaged. The stepwise treatment approach with the customized round bur combined with the system-specific drills of the service set saved the blocked implant so that the patient could be successfully rehabilitated with a new implant reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Libraries of learning objects may serve as basis for deriving course offerings that are customized to the needs of different learning communities or even individuals. Several ways of organizing this course composition process are discussed. Course composition needs a clear understanding of the dependencies between the learning objects. Therefore we discuss the metadata for object relationships proposed in different standardization projects and especially those suggested in the Dublin Core Metadata Initiative. Based on these metadata we construct adjacency matrices and graphs. We show how Gozinto-type computations can be used to determine direct and indirect prerequisites for certain learning objects. The metadata may also be used to define integer programming models which can be applied to support the instructor in formulating his specifications for selecting objects or which allow a computer agent to automatically select learning objects. Such decision models could also be helpful for a learner navigating through a library of learning objects. We also sketch a graph-based procedure for manual or automatic sequencing of the learning objects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Specification consortia and standardization bodies concentrate on e-Learning objects to en-sure reusability of content. Learning objects may be collected in a library and used for deriv-ing course offerings that are customized to the needs of different learning communities. How-ever, customization of courses is possible only if the logical dependencies between the learn-ing objects are known. Metadata for describing object relationships have been proposed in several e-Learning specifications. This paper discusses the customization potential of e-Learning objects but also the pitfalls that exist if content is customized inappropriately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Importance: Although rheumatic heart disease has been nearly eradicated in high-income countries, 3 in 4 children grow up in parts of the world where it is still endemic. Objectives: To determine the prevalence of clinically silent and manifest rheumatic heart disease as a function of age, sex, and socioeconomic status and to estimate age-specific incidence. Design, Setting, and Participants: In this school-based cross-sectional study with cluster sampling, 26 schools in the Sunsari district in Eastern Nepal with 5467 eligible children 5 to 15 years of age were randomly selected from 595 registered schools. After exclusion of 289 children, 5178 children were enrolled in the present study from December 12, 2012, through September 12, 2014. Data analysis was performed from October 1, 2014, to April 15, 2015. Exposures: Demographic and socioeconomic characteristics were acquired in a standardized interview by means of a questionnaire customized to the age of the children. A focused medical history was followed by a brief physical examination. Cardiac auscultation and transthoracic echocardiography were performed by 2 independent physicians. Main Outcomes and Measures: Rheumatic heart disease according to the World Heart Federation criteria. Results: The median age of the 5178 children enrolled in the study was 10 years (interquartile range, 8-13 years), and 2503 (48.3%) were female. The prevalence of borderline or definite rheumatic heart disease was 10.2 (95% CI, 7.5-13.0) per 1000 children and increased with advancing age from 5.5 (95% CI, 3.5-7.5) per 1000 children 5 years of age to 16.0 (95% CI, 14.9-17.0) in children 15 years of age, whereas the mean incidence remained stable at 1.1 per 1000 children per year. Children with rheumatic heart disease were older than children without rheumatic heart disease (median age [interquartile range], 11 [9-14] years vs 10 [8-13] years; P = .03), more commonly female (34 [64.2%] vs 2469 [48.2%]; P = .02), and more frequently went to governmental schools (40 [75.5%] vs 2792 [54.5%]; P = .002). Silent disease (n = 44) was 5 times more common than manifest disease (n = 9). Conclusions and Relevance: Rheumatic heart disease affects 1 in 100 schoolchildren in Eastern Nepal, is primarily clinically silent, and may be more common among girls. The overall prevalence and the ratio of manifest to subclinical disease increase with advancing age, whereas the incidence remains stable at 1.1 per 1000 children per year. Early detection of silent disease may help prevent progression to severe valvular damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nucleus pulposus replacements have been subjected to highly controversial discussions over the last 40 years. Their use has not yet resulted in a positive outcome to treat herniated disc or degenerated disc disease. The main reason is that not a single implant or tissue replacement was able to withstand the loads within an intervertebral disc. Here, we report on the development of a photo-polymerizable poly(ethylene glycol)dimethacrylate nano-fibrillated cellulose composite hydrogel which was tuned according to native tissue properties. Using a customized minimally-invasive medical device to inject and photopolymerize the hydrogel insitu, samples were implanted through an incision of 1 mm into an intervertebral disc of a bovine organ model to evaluate their long-term performance. When implanted into the bovine disc model, the composite hydrogel implant was able to significantly re-establish disc height after surgery (p < 0.0025). The height was maintained after 0.5 million loading cycles (p < 0.025). The mechanical resistance of the novel composite hydrogel material combined with the minimally invasive implantation procedure into a bovine disc resulted in a promising functional orthopedic implant for the replacement of the nucleus pulposus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Growth hormone replacement therapy (GHRT) increases exercise capacity and insulin resistance while it decreases fat mass in growth hormone-deficient patients (GHD). Ectopic lipids (intramyocellular (IMCL) and intrahepatocellular lipids (IHCL) are related to insulin resistance. The effect of GHRT on ectopic lipids is unknown. It is hypothesized that exercise-induced utilization of ectopic lipids is significantly decreased in GHD patients and normalized by GHRT. GHD (4 females, 6 males) and age/gender/waist-matched control subjects (CS) were studied. VO2max was assessed on a treadmill and insulin sensitivity determined by a two-step hyperinsulinaemic-euglycaemic clamp. Visceral (VAT) and subcutaneous (SAT) fat were quantified by MR-imaging. IHCL and IMCL were measured before and after a 2 h exercise at 50-60% of VO2max using MR-spectroscopy (∆IMCL, ∆IHCL). Identical investigations were performed after 6 months of GHRT. VO2max was similar in GHD and CS and significantly increased after GHRT; GHRT significantly decreased SAT and VAT. 2 h-exercise resulted in a decrease in IMCL (significant in CS and GHRT) and a significant increase in IHCL in CS and GHD pre and post GHRT. GHRT didn't significantly impact on ∆IMCL and ∆IHCL. We conclude that aerobic exercise affects ectopic lipids in patients and controls. GHRT increases exercise capacity without influencing ectopic lipids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to the lack of exercise testing devices that can be employed in stroke patients with severe disability, the aim of this PhD research was to investigate the clinical feasibility of using a robotics-assisted tilt table (RATT) as a method for cardiopulmonary exercise testing (CPET) and exercise training in stroke patients. For this purpose, the RATT was augmented with force sensors, a visual feedback system and a work rate calculation algorithm. As the RATT had not been used previously for CPET, the first phase of this project focused on a feasibility study in 11 healthy able-bodied subjects. The results demonstrated substantial cardiopulmonary responses, no complications were found, and the method was deemed feasible. The second phase was to analyse validity and test-retest reliability of the primary CPET parameters obtained from the RATT in 18 healthy able-bodied subjects and to compare the outcomes to those obtained from standard exercise testing devices (a cycle ergometer and a treadmill). The results demonstrated that peak oxygen uptake (V'O2peak) and oxygen uptake at the submaximal exercise thresholds on the RATT were ̴20% lower than for the cycle ergometer and ̴30% lower than on the treadmill. A very high correlation was found between the RATT vs the cycle ergometer V'O2peak and the RATT vs the treadmill V'O2peak. Test-retest reliability of CPET parameters obtained from the RATT were similarly high to those for standard exercise testing devices. These findings suggested that the RATT is a valid and reliable device for CPET and that it has potential to be used in severely impaired patients. Thus, the third phase was to investigate using the RATT for CPET and exercise training in 8 severely disabled stroke patients. The method was technically implementable, well tolerated by the patients, and substantial cardiopulmonary responses were observed. Additionally, all patients could exercise at the recommended training intensity for 10 min bouts. Finally, an investigation of test-retest reliability and four-week changes in cardiopulmonary fitness was carried out in 17 stroke patients with various degrees of disability. Good to excellent test-retest reliability and repeatability were found for the main CPET variables. There was no significant difference in most CPET parameters over four weeks. In conclusion, based on the demonstrated validity, reliability and repeatability, the RATT was found to be a feasible and appropriate alternative exercise testing and training device for patients who have limitations for use of standard devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A three-level satellite to ground monitoring scheme for conservation easement monitoring has been implemented in which high-resolution imagery serves as an intermediate step for inspecting high priority sites. A digital vertical aerial camera system was developed to fulfill the need for an economical source of imagery for this intermediate step. A method for attaching the camera system to small aircraft was designed, and the camera system was calibrated and tested. To ensure that the images obtained were of suitable quality for use in Level 2 inspections, rectified imagery was required to provide positional accuracy of 5 meters or less to be comparable to current commercially available high-resolution satellite imagery. Focal length calibration was performed to discover the infinity focal length at two lens settings (24mm and 35mm) with a precision of O.1mm. Known focal length is required for creation of navigation points representing locations to be photographed (waypoints). Photographing an object of known size at distances on a test range allowed estimates of focal lengths of 25.lmm and 35.4mm for the 24mm and 35mm lens settings, respectively. Constants required for distortion removal procedures were obtained using analytical plumb-line calibration procedures for both lens settings, with mild distortion at the 24mm setting and virtually no distortion found at the 35mm setting. The system was designed to operate in a series of stages: mission planning, mission execution, and post-mission processing. During mission planning, waypoints were created using custom tools in geographic information system (GIs) software. During mission execution, the camera is connected to a laptop computer with a global positioning system (GPS) receiver attached. Customized mobile GIs software accepts position information from the GPS receiver, provides information for navigation, and automatically triggers the camera upon reaching the desired location. Post-mission processing (rectification) of imagery for removal of lens distortion effects, correction of imagery for horizontal displacement due to terrain variations (relief displacement), and relating the images to ground coordinates were performed with no more than a second-order polynomial warping function. Accuracy testing was performed to verify the positional accuracy capabilities of the system in an ideal-case scenario as well as a real-world case. Using many welldistributed and highly accurate control points on flat terrain, the rectified images yielded median positional accuracy of 0.3 meters. Imagery captured over commercial forestland with varying terrain in eastern Maine, rectified to digital orthophoto quadrangles, yielded median positional accuracies of 2.3 meters with accuracies of 3.1 meters or better in 75 percent of measurements made. These accuracies were well within performance requirements. The images from the digital camera system are of high quality, displaying significant detail at common flying heights. At common flying heights the ground resolution of the camera system ranges between 0.07 meters and 0.67 meters per pixel, satisfying the requirement that imagery be of comparable resolution to current highresolution satellite imagery. Due to the high resolution of the imagery, the positional accuracy attainable, and the convenience with which it is operated, the digital aerial camera system developed is a potentially cost-effective solution for use in the intermediate step of a satellite to ground conservation easement monitoring scheme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is estimated that more than half the U.S. adult population is overweight or obese as classified by a body mass index of 25.0–29.9 or ≥30 kg/m 2, respectively. Since the current treatment approaches for long-term maintenance of weight loss are lacking, the National Institutes of Health state that an effective approach may be to focus on weight gain prevention. There is a limited body of literature describing how adults maintain a stable weight as they age. It is hypothesized that weight stability is the result of a balance between energy consumption and energy expenditure as influenced by diet, lifestyle, behavior, genetics and environment. The purpose of this research was to examine the dietary intake and behaviors, lifestyle habits, and risk factors for weight change that predict weight stability in a cohort of 2101 men and 389 women aged 20 to 8 7 years in the Aerobic Center Longitudinal Study regardless of body weight at baseline. At baseline, participants completed a maximal exercise treadmill test to determine cardiorespiratory fitness, a medical history questionnaire, which included self-reported measures of weight, dietary behaviors, lifestyle habits, and risk factors for weight change, a three-day diet record, and a mail-back version of the medical history questionnaire in 1990 or 1995. All analyses were performed separately for men and women. Results from multivariate regression analyses indicated that the strongest predictor of follow-up weight for men and women was previous weight, accounting for 87.0% and 81.9% of the variance, respectively. Age, length of follow-up and eating habits were also significant predictors of follow-up weight in men, though these variables only explained 3% of the variance. For women, length of follow-up and currently being on a diet were significantly associated with follow-up weight but these variables explained only an additional 2% of the variance. Understanding the factors that influence weight change has tremendous public health importance for developing effective methods to prevent weight gain. Since current weight was the strongest predictor of previous weight, preventing initial weight gain by maintaining a stable weight may be the most effective method to combat the increasing prevalence of overweight and obesity. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context. Alzheimer’s disease is a major source of morbidity and mortality in aging societies. Preventive measures, such as increasing cardiorespiratory fitness, to reduce the risk of Alzheimer’s disease mortality have not been sufficiently examined.^ Objective. To examine the association between levels of cardiorespiratory fitness and Alzheimer’s disease mortality.^ Design, Setting, and Patients. A prospective cohort study of 53,911 men and 18,876 women (mean age, 51.4 [SD, 10.0] years; range 20-88) enrolled in the Cooper Center Longitudinal Study who completed a baseline health examination during 1970-2006. The primary exposure, cardiorespiratory fitness, was assessed via a maximal exercise test. Fitness was categorized according to age- and sex-specific tertiles based on the participants’ distribution of maximal treadmill exercise test duration, in metabolic equivalent tasks (METs). The main outcome measure was Alzheimer’s disease mortality, defined as the underlying or contributing cause of death using the National Death Index and death certificates through December 31, 2006.^ Results. There were 175 Alzheimer’s disease deaths during a mean follow up of 37 years and 1,309,170 person-years of exposure. Women in the high fitness category had a 70% reduction in risk of Alzheimer’s mortality compared to women in the low fitness category (HR=0.3; 95% CI, 0.1-0.8; P=.02), while adjusting for potential confounders. Similarly, women in the moderate fitness category had a 70% reduction in risk for AD mortality compared to women in the low fit category (HR=0.3; 95% CI, 0.1-0.7; P=.005). Among men, the relationship between fitness level and AD mortality risk was examined but none were of statistical significance. The adjusted comparison of men in the high fitness category to low fit men yielded an HR of 0.9 (95% CI, 0.6-1.5; P=.79), while moderately fit men compared to low fit men yielded an HR of 1.3 (95% CI, 0.9-1.9; P=.21).^ Conclusions. Higher levels of cardiorespiratory fitness were associated with decreased risk of AD mortality, in women. No statistically significant association was found among men. Physical fitness may be an important protective factor against Alzheimer’s disease death in women, further supporting its clinical and public health values.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective measurements of physical fitness and pulmonary function are related individually to long-term survival, both in healthy people and in those who are ill. These factors are furthermore known to be related to one another physiologically in people with pulmonary disease, because advanced pulmonary disease causes ventilatory limitation to exercise. Healthy people do not have ventilatory limitation to exercise, but rather have ventilatory reserve. The relationship between pulmonary function and exercise performance in healthy people is minimal. Exercise performance has been shown to modify the effect of pulmonary function on mortality in people with chronic obstructive pulmonary disease, but the relationship between these factors in healthy people has not been studied and is not known. The purpose of this study is to quantify the joint effects of pulmonary function and exercise performance as these bear on mortality in a cohort of healthy adults. This investigation is an historical cohort study over 20 years of follow-up of 29,624 adults who had complete preventive medicine, spirometry and treadmill stress examinations at the Cooper Clinic in Dallas, Texas.^ In 20 years of follow-up, there were 738 evaluable deaths. Forced expiratory volume in one second (FEV$\sb1$) percent of predicted, treadmill time in minutes percent of predicted, age, gender, body mass index, baseline smoking status, serum glucose and serum total cholesterol were all significant, independent predictors of mortality risk. There were no frank interactions, although age had an important increasing effect on the risk associated with smoking when other covariates were controlled for in a proportional-hazards model. There was no confounding effect of exercise performance on pulmonary function. In agreement with the pertinent literature on independent effects, each unit increase in FEV$\sb1$ percent predicted was associated with about eight tenths of a percent reduction in adjusted mortality rate. The concept of physiologic reserve is useful in interpretation of the findings. Since pulmonary function does not limit exercise tolerance in healthy adults, it is reasonable to expect that exercise tolerance would not modify the effect of pulmonary function on mortality. Epidemiologic techniques are useful for elucidating physiological correlates of mortality risk. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to examine, in the context of an economic model of health production, the relationship between inputs (health influencing activities) and fitness.^ Primary data were collected from 204 employees of a large insurance company at the time of their enrollment in an industrially-based health promotion program. The inputs of production included medical care use, exercise, smoking, drinking, eating, coronary disease history, and obesity. The variables of age, gender and education known to affect the production process were also examined. Two estimates of fitness were used; self-report and a physiologic estimate based on exercise treadmill performance. Ordinary least squares and two-stage least squares regression analyses were used to estimate the fitness production functions.^ In the production of self-reported fitness status the coefficients for the exercise, smoking, eating, and drinking production inputs, and the control variable of gender were statistically significant and possessed theoretically correct signs. In the production of physiologic fitness exercise, smoking and gender were statistically significant. Exercise and gender were theoretically consistent while smoking was not. Results are compared with previous analyses of health production. ^