856 resultados para comfort, outdoor, indoor
Resumo:
Ozone monitoring techniques utilize expensive instruments that are often large and heavy. These instruments are not easy to handle in the field, and their size also limits some sampling schemes, principally for indoor ozone determination. We have developed a lightweight, inexpensive, and sensitive method that offers flexibility to undertake measurements of ambient ozone in many environments, both indoor and outdoor. The method is based on the reaction of ozone with indigo blue dye. The indigo molecule contains 1 carbon double bond (C = C) that reacts with ozone and results in nearly colorless reaction products. During sample collection, 2 cellulose filters coated with 40 mu L of 1.0 x 10(-3) M indigo blue were used. The determinations were done spectrophotometrically at 250 and 600 nm. The analytical parameters studied were sampling time and flow rate. Analytical curves were constructed with concentrations ranging from 37 to 123 parts per billion by volume (ppbv) of standard ozone, at 0.4 L/min and 15 min sampling time. The detection limits achieved were 6 and 9 ppbv, respectively, at 250 and 600 nm. Considering interferences, measurements made at 250 nm gave more reliable and specific values for ozone.
Resumo:
Background: Air conditioning-induced rhinitis in allergic individuals is a common epidemiologic finding, but its physiopathology,is still controversial. The aim of this study was to describe and compare the effects of experimental air conditioning temperature changes on the nasal mucosa of individuals with persistent allergic rhinitis compared with a control group.Methods: A case-control challenge study was performed in a laboratory of thermal comfort with experimental twin challenge chambers set at a 12 C difference in temperature. A group of 32 patients with persistent allergic rhinitis and a group of 16 control subjects were exposed for 30 minutes, 3 times alternately in each chamber. Nasal symptom scores were recorded and nasal samples collected before, immediately after, and 24 and 48 hours after the challenge.Results: the rhinitis group showed a higher symptom score, epithelial shedding, percentage of eosinophils, total inflammatory cells, leukotriene C-4, eosinophil cationic protein, albumin, and tryptase levels compared with controls. There was also a significant increase in symptom score, total cells recovered, percentage of eosinophils, epithelial shedding, albumin, myeloperoxidase, and soluble intercellular adhesion molecule 1 in both groups compared with baseline levels.Conclusion: Sudden temperature changes led to a more pronounced inflammatory nasal response in the rhinitis group with the recruitment and activation of eosinophils.Clinical implications: Persistent allergic rhinitis is a risk factor for developing sudden temperature change-related rhinitis even in the absence of allergen exposure.
Resumo:
According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
This article is about thermal comfort in the wearable product. The research correlates fashion and architecture, in so far as it elects the brise soleil - an architectural element capable of regulating temperature and ventilation inside buildings - as a study referential, in trying to transpose and adapt its mechanisms to the wearable apparel.
Resumo:
This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.
Resumo:
Most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established national institutions and national programs in charge of the study of radon and its connection with lung cancer risk and public health. In this paper an indoor radon measurements in Latin American countries is presented. The participants in this work were from Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. Many different techniques are used in this common effort, and the indoor radon levels in specific locations in each of the participant countries are presented.
Resumo:
The quality of open urban spaces is very important for urban vitality. Nowadays urban designers have to face the great challenge of designing urban spaces able to respond to people's need for liveable spaces. The success of these spaces depends on various aspects and the microclimatic condition has been recognized as one of the most influential. However, studies on thermal comfort in open space have shown that the user's thermal sensation does not depend only on microclimate parameters but also on other local qualitative aspects. Thus, environmental quality evaluation of successful public spaces can contribute to understand this issue. This paper focuses on a case study regarding Queen Square's environmental quality, a public space of historical importance in Bath-UK. The first stage of the research, a study on local characteristics and people observations, allowed a preliminary evaluation of the space performance, their social aspects, while it characterized and quantified the hourly variation of the space use in different days and seasons. In the second stage, short microclimatic surveys were carried out simultaneously with a perception survey through a questionnaire. The results show the strong vitality of the square and socioenvironmental significance, not only for its location in the urban context, but also for its historical value. The environmental quality of the square contributes to the users' sensation of comfort even in adverse climatic conditions. This research is part of a project that aims to investigate the impact of the environmental stimuli in the use of open spaces and intend to develop design strategies that aim to maximise the use of open spaces in different weather conditions.
Resumo:
This study is aimed to analyze the thermal comfort in different areas in the city of São Paulo. Two different areas were selected, a densely built (Consolação district) and the other was Fontes do Ipiranga State Park (FISP), an area with only a few buildings and reduced impermeability. A micro-climatic ENVImet was used to simulate the interaction surface-atmosphere in the urban environment. The model resolution is between 0.5 and 10m. This model was developed by Bruse and Fleer (1998) and Bruse (2004). Through the thermal comfort index PMV (predicted mean vote) and MRT (mean radiant temperature) provided by the model, it revealed that the State Park displays PMV values close to comfortable compared to the other studied area. The analysis of thermal comfort index and the Wind flow showed the influence of high buildings in the local climatic environment.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O presente trabalho propõe metodologias para detectar a presença e localizar um intruso em ambientes indoor, 2-D e 3-D, sendo que neste último, utiliza-se um sistema cooperativo de antenas e, em ambos os casos, o sistema é baseado em radares multiestáticos. Para obter uma alta resolução, o radar opera com pulsos UWB, que possuem amplitude espectral máxima em 1 GHz para ambientes 2-D e, pulsos de banda larga com frequências entre 200 MHz e 500 MHz para ambientes 3-D. A estimativa de localização, para os ambientes bidimensionais, é feita pela técnica de otimização Enxame de Partículas - PSO (Particle Swarm Optimization), pelo método de Newton com eliminação de Gauss e pelo método dos mínimos quadrados com eliminação de Gauss. Para o ambiente tridimensional, foi desenvolvida uma metodologia vetorial que estima uma possível região de localização do intruso. Para a simulação das ondas eletromagnéticas se utiliza o método numérico FDTD (Diferenças Finitas no Domínio do Tempo) associado à técnica de absorção UPML (Uniaxial Perfectly Matched Layer) com o objetivo de truncar o domínio de análise simulando uma propagação ao infinito. Para a análise do ambiente em 2-D foi desenvolvido o ACOR-UWB-2-D e para o ambiente 3-D foi utilizado o software LANE SAGS.
Resumo:
O projeto de sistemas de comunicações móveis requer o conhecimento do ambiente em que será implementado. Para tanto, busca-se a exatidão na predição de propagação do sinal através do uso de modelos de predição. O presente trabalho propõe um modelo empírico para a estimativa da intensidade de sinal recebida em ambientes indoor, e que apresentam mais de uma fonte transmissora, utilizando Sistema de Antenas Distribuídas (DAS). O método apresenta uma generalização para o caso de múltiplas fontes, também chamado multifontes, e como caso particular com apenas uma fonte. A modelagem é feita através do uso de radiais partindo de cada transmissor, com o intuito de considerar a variabilidade do sinal em ambientes indoor. Estas várias perturbações no sinal, que causam desvanecimento rápido são caracterizadas através das distribuições estatísticas de desvanecimento. As mais utilizadas como a de Rayleigh, Rice e Nakagami são apresentadas para caracterização do canal, além dessas são calculadas as distribuições recentemente desenvolvidas, de Kappa-mi e Eta-mi. Para a validação do modelo realizaram-se campanhas de medições em um shopping center, que possui um DAS, com o teste em dois ambientes distintos, um supermercado e uma praça de alimentação. As simulações são realizadas no software MATLAB® e o desempenho dos resultados avaliados através do cálculo dos erros absoluto, desvio padrão e erro rms.
Resumo:
O advento de novas formas multimídia tem atraído uma clientela exigente, onde preocupação não é somente com o serviço, mas também, com a qualidade que esse serviço pode ser oferecido. As WLAN (Wireless Local Area Networks) tornaram-se a forma mais comum de roteamento de Internet, devido ao seu baixo custo e facilidade de implementação. Para realizar um bom roteamento é necessário um planejamento, utilizando-se modelos. Os modelos de propagação existentes na literatura fazem a predição da intensidade do sinal, mas algumas vezes não contemplam a previsão de um bom serviço. Nesse sentido a presente dissertação propõe-se a elaborar um modelo de propagação empírico indoor multi-andar que não só prediz a potência recebida, mas também faz uma previsão para algumas métricas de QoS (Quality of Service) de chamadas VoIP (Voice over Internet Protocol). Para a elaboração do modelo proposto foram feitas campanhas de medição, em um prédio de dois andares, em pisos distintos mantendo-se a posição do ponto de acesso (PA) fixa. Estudos de geometria analítica para a contagem e agregação de perdas em pisos e paredes. Os resultados do modelo proposto foram comparados com um modelo da literatura que tem um comportamento similar, onde é possível verificar o melhor desempenho do modelo proposto, e para efeito de estudo um andar completamente simulado foi introduzido para avaliação.
Resumo:
Este trabalho trata de alguns modelos de propagação de ondas eletromagnéticas. Primeiramente, foram analisados modelos relacionados com a predição do sinal eletromagnético em ambientes indoor. Os modelos utilizados neste trabalho foram o Traçado de Raios, Caminho Dominante de Energia (DPM) e o FDTD. Para os dois primeiros modelos foi, utilizado um software comercial e para o método FDTD foi desenvolvido um algoritmo para o qual o sinal é analisado em um ambiente com a mesma geometria utilizada no software. Os resultados, para os pontos de recepção analisados, fornecidos pelos três modelos, são concordantes. Verifica-se a influência dos fenômenos de propagação na intensidade do sinal. A relevância deste trabalho encontra-se no fato de não haver, na literatura pesquisada, trabalhos que comparassem os três modelos de predição mencionados, além de propor temas para pesquisas futuras.
Resumo:
O ensaio imunoenzimático para identificação de repastos sangüíneos apresenta especificidade até nível de gênero, sensibilidade para identificação de repastos sangüíneos parciais e detecção de repastos múltiplos. Foram identificadas as fontes alimentares de 82% dos anofelinos coletados em campo. Foram testados seis anticorpos monoclonais (humano, suíno, cão, bovino, rato e galinha) e destes, apenas o anti- IgG bovino apresentou instabilidade. Obteve-se 55,7% (519/932) dos repastos positivos para sangue humano, o que demonstra, a preferência alimentar destes anofelinos por humanos. Dos 206 mosquitos que apresentaram repasto único, 27,6% foi em humanos. O Anopheles darlingi apresentou 41% dos repastos em humanos e o Índice de Sangue Humano (HBI) no intradomicílio foi de 0,71. An. marajoara apresentou 51,3% dos repastos em humanos, embora tenha sido encontrada em grande quantidade no ambiente extradomiciliar e apresentando HBI no intradomicílio de 0,76. O An. nuneztovari foi a espécie mais abundante, apresentando comportamento exofílico e antropofílico, com 53,8% de repastos em humano e HBI no intradomicílio de 0,65. O método ELISA Sanduíche está implantado, identificando a fonte alimentar das espécies de anofelinos coletadas em campo, exceto para bovino. É a primeira vez que esta técnica é utilizada para determinação de repastos sanguíneos em anofelinos na região Amazônica brasileira. É importante a determinação da fonte alimentar das espécies de anofelinos no sentido de caracterizar o comportamento antropofílico e assim associá-las ou não à transmissão de malária.