957 resultados para Weighted Mri


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem examinations and magnetic resonance imaging (MRI) studies suggest involvement of the entorhinal cortex (EC) in schizophrenic psychoses. However, the extent and nature of the possible pathogenetical process underlying the observed alterations of this limbic key region for processing of multimodal sensory information remains unclear. Three-dimensional high-resolution MRI volumetry and evaluation of the regional diffusional anisotropy based on diffusion tensor imaging (DTI) were performed on the EC of 15 paranoid schizophrenic patients and 15 closely matched control subjects. In schizophrenic patients, EC volumes showed a slight, but not significant, decrease. However, the anisotropy values, expressed as inter-voxel coherences (COH), were found to be significantly decreased by 17.9% (right side) and 12.5% (left side), respectively, in schizophrenics. Reduction of entorhinal diffusional anisotropy can be hypothesized to be functionally related to disturbances in the perforant path, the principal efferent EC fiber tract supplying the limbic system with neuronal input from multimodal association centers. Combinations of different MRI modalities are a promising approach for the detection and characterization of subtle brain tissue alterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Cognitive complaints, such as poor concentration and memory deficits, are frequent after whiplash injury and play an important role in disability. The origin of these complaints is discussed controversially. Some authors postulate brain lesions as a consequence of whiplash injuries. Potential diffuse axonal injury (DAI) with subsequent atrophy of the brain and ventricular expansion is of particular interest as focal brain lesions have not been documented so far in whiplash injury. OBJECTIVE: To investigate whether traumatic brain injury can be identified using a magnetic resonance (MR)-based quantitative analysis of normalized ventricle-brain ratios (VBR) in chronic whiplash patients with subjective cognitive impairment that cannot be objectively confirmed by neuropsychological testing. MATERIALS AND METHODS: MR examination was performed in 21 patients with whiplash injury and symptom persistence for 9 months on average and in 18 matched healthy controls. Conventional MR imaging (MRI) was used to assess the volumes of grey and white matter and of ventricles. The normalized VBR was calculated. RESULTS: The values of normalized VBR did not differ in whiplash patients when compared with that in healthy controls (F = 0.216, P = 0.645). CONCLUSIONS: This study does not support loss of brain tissue following whiplash injury as measured by VBR. On this basis, traumatic brain injury with subsequent DAI does not seem to be the underlying mechanism for persistent concentration and memory deficits that are subjectively reported but not objectively verifiable as neuropsychological deficits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish an MRI classification system for intervertebral disks using axial T2 mapping, with a special focus on evaluating early degenerative intervertebral disks. MATERIALS AND METHODS: Twenty-nine healthy volunteers (19 men, 10 women; age range, 20-44 years; mean age, 31.8 years) were studied, and axial T2 mapping was performed for the L3-L4, L4-L5, and L5-S1 intervertebral disks. Grading was performed using three classification systems for degenerative disks: our system using axial T2 mapping and two other conventional classification systems that focused on the signal intensity of the nucleus pulposus or the structural morphology in sagittal T2-weighted MR images. We analyzed the relationship between T2, which is known to correlate with change in composition of intervertebral disks, and degenerative grade determined using the three classification systems. RESULTS: With axial T2 mapping, differences in T2 between grades I and II were smaller and those between grades II and III, and between grades III and IV, were larger than those with the other grading systems. The ratio of intervertebral disks classified as grade I was higher with the conventional classification systems than that with axial T2 mapping. In contrast, the ratio of intervertebral disks classified as grade II or III was higher with axial T2 mapping than that with the conventional classification systems. CONCLUSION: Axial T2 mapping provides a more T2-based classification. The new system may be able to detect early degenerative changes before the conventional classification systems can.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI), 40 forensic cases were examined and findings were verified by subsequent autopsy. Results were classified as follows: (I) cause of death, (II) relevant traumatological and pathological findings, (III) vital reactions, (IV) reconstruction of injuries, (V) visualization. In these 40 forensic cases, 47 partly combined causes of death were diagnosed at autopsy, 26 (55%) causes of death were found independently using only radiological image data. Radiology was superior to autopsy in revealing certain cases of cranial, skeletal, or tissue trauma. Some forensic vital reactions were diagnosed equally well or better using MSCT/MRI. Radiological imaging techniques are particularly beneficial for reconstruction and visualization of forensic cases, including the opportunity to use the data for expert witness reports, teaching, quality control, and telemedical consultation. These preliminary results, based on the concept of "virtopsy," are promising enough to introduce and evaluate these radiological techniques in forensic medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem examination of chest trauma is an important domain in forensic medicine, which is today performed using autopsy. Since the implementation of cross-sectional imaging methods in forensic medicine such as computed tomography (CT) and magnetic resonance imaging (MRI), a number of advantages in comparison with autopsy have been described. Within the scope of validation of cross-sectional radiology in forensic medicine, the comparison of findings of postmortem imaging and autopsy in chest trauma was performed. METHODS: This retrospective study includes 24 cases with chest trauma that underwent postmortem CT, MRI, and autopsy. Two board-certified radiologists, blind to the autopsy findings, evaluated the radiologic data independently. Each radiologist interpreted postmortem CT and MRI data together for every case. The comparison of the results of the radiologic assessment with the autopsy and a calculation of interobserver discrepancy was performed. RESULTS: Using combined CT and MRI, between 75% and 100% of the investigated findings, except for hemomediastinum (70%), diaphragmatic ruptures (50%; n=2) and heart injury (38%), were discovered. Although the sensitivity and specificity regarding pneumomediastinum, pneumopericardium, and pericardial effusion were not calculated, as these findings were not mentioned at the autopsy, these findings were clearly seen radiologically. The averaged interobserver concordance was 90%. CONCLUSION: The sensitivity and specificity of our results demonstrate that postmortem CT and MRI are useful diagnostic methods for assessing chest trauma in forensic medicine as a supplement to autopsy. Further radiologic-pathologic case studies are necessary to define the role of postmortem CT and MRI as a single examination modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic accuracy of in situ postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) in the detection of primary traumatic extra-axial hemorrhage. MATERIALS AND METHODS: Thirty forensic neurotrauma cases and 10 nontraumatic controls who underwent both in situ postmortem cranial MSCT and MR imaging before autopsy were retrospectively reviewed. Both imaging modalities were analyzed in view of their accuracy, sensitivity, and specificity concerning the detection of extra-axial hemorrhage. Statistical significance was calculated using the McNemar test. kappa values for interobserver agreement were calculated for extra-axial hemorrhage types and to quantify the agreement between both modalities as well as MRI, CT, and forensics, respectively. RESULTS: Analysis of the detection of hemorrhagic localizations showed an accuracy, sensitivity, and specificity of 89%, 82%, and 92% using CT, and 90%, 83%, and 94% using MRI, respectively. MRI was more sensitive than CT in the detection of subarachnoid hemorrhagic localizations (P = 0.001), whereas no significant difference resulted from the detection of epidural and subdural hemorrhagic findings (P = 0.248 and P = 0.104, respectively). Interobserver agreement for all extra-axial hemorrhage types was substantial (CT kappa = 0.76; MRI kappa = 0.77). The agreement of both modalitites was almost perfect (readers 1 and 2 kappa = 0.88). CONCLUSION: CT and MRI are of comparable potential as forensic diagnostic tools for traumatic extra-axial hemorrhage. Not only of forensic, but also of clinical interest is the observation that most thin blood layers escape the radiological evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 34-year-old woman who had a left anterior wall myocardial infarction develop in the first trimester of pregnancy. Despite urgent and successful revascularization, she demonstrated persistent segmental wall motion abnormalities by transthoracic echocardiography. To manage this patient safely through pregnancy with a better definition of myocardium at risk, a cardiac magnetic resonance examination was performed. This identified a large territory of acutely edematous myocardium in addition to providing accurate volumetric measurements of left ventricular size and function. Because of her gravid state, gadolinium was not administered nor was it required to delineate the region of myocardium at risk.