950 resultados para Ultrasonic velocity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague-Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by similar to 20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the clinical setting, the early detection of myocardial injury induced by doxorubicin (DXR) is still considered a challenge. To assess whether ultrasonic tissue characterization (UTC) can identify early DXR-related myocardial lesions and their correlation with collagen myocardial percentages, we studied 60 rats at basal status and prospectively after 2mg/Kg/week DXR endovenous infusion. Echocardiographic examinations were conducted at baseline and at 8,10,12,14 and 16 mg/Kg DXR cumulative dose. The left ventricle ejection fraction (LVEF), shortening fraction (SF), and the UTC indices: corrected coefficient of integrated backscatter (IBS) (tissue IBS intensity/phantom IBS intensity) (CC-IBS) and the cyclic variation magnitude of this intensity curve (MCV) were measured. The variation of each parameter of study through DXR dose was expressed by the average and standard error at specific DXR dosages and those at baseline. The collagen percent (%) was calculated in six control group animals and 24 DXR group animals. CC-IBS increased (1.29 +/- 0.27 x 1.1 +/- 0.26-basal; p=0.005) and MCV decreased (9.1 +/- 2.8 x 11.02 +/- 2.6-basal; p=0.006) from 8 mg/Kg to 16mg/Kg DXR. LVEF presented only a slight but significant decrease (80.4 +/- 6.9% x 85.3 +/- 6.9%-basal, p=0.005) from 8 mg/Kg to 16 mg/Kg DXR. CC-IBS was 72.2% sensitive and 83.3% specific to detect collagen deposition of 4.24%(AUC=0.76). LVEF was not accurate to detect initial collagen deposition (AUC=0.54). In conclusion: UTC was able to early identify the DXR myocardial lesion when compared to LVEF, showing good accuracy to detect the initial collagen deposition in this experimental animal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To identify potential associations between fetal surveillance tests and acidosis at birth in pregnancies with abnormal but positive end-diastolic velocity in the umbilical artery. Methods: A prospective case-control study [group 1: pH < 7.2; group 2: pH >= 7.2] including 46 fetuses with abnormal but positive end-diastolic velocity in the umbilical artery was conducted between February 2007 and March 2009. Outcome variables were evaluated by univariate analysis and compared between the two groups. Clinically relevant and statistically significant variables were analyzed by logistic regression. Results: Abnormal nonstress test, presence of deceleration, and absent fetal breathing movements were statistically significant. Logistic regression analysis revealed that fetal heart rate (FHR) deceleration in the nonstress test is the only predictor of fetal acidosis at birth (p = 0.024; OR = 8.2; 95% CI: 1.2-52). Conclusions: In fetuses with positive end-diastolic flow velocity, acute variables of the antenatal surveillance tests are correlated with acidosis at birth and FHR deceleration in the nonstress test is the only predictor of fetal acidosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theoretical E-curve for the laminar flow of non-Newtonian fluids in circular tubes may not be accurate for real tubular systems with diffusion, mechanical vibration, wall roughness, pipe fittings, curves, coils, or corrugated walls. Deviations from the idealized laminar flow reactor (LFR) cannot be well represented using the axial dispersion or the tanks-in-series models of residence time distribution (RTD). In this work, four RTD models derived from non-ideal velocity profiles in segregated tube flow are proposed. They were used to represent the RTD of three tubular systems working with Newtonian and pseudoplastic fluids. Other RTD models were considered for comparison. The proposed models provided good adjustments, and it was possible to determine the active volumes. It is expected that these models can be useful for the analysis of LFR or for the evaluation of continuous thermal processing of viscous foods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the complex reflection coefficient of ultrasonic shear-waves at the solid-liquid interface is a technique employed for the measurement of the viscoelastic properties of liquids. An interesting property of the measurement technique is the very small penetration depth of the shear-waves into the liquid sample, which permits measurements with liquid films of some micrometers thick. This property, along with the adhesion of oily substances to surfaces, can be used for the detection of oily contaminants in water. In this work, the employment of the ultrasonic shear-wave reflection technique to the detection of oily contaminants in water is proposed and the theoretical and experimental concepts involved are discussed. Preliminary experimental results show the measurement technique can detect SAE 40 automotive oil in water in volume proportions less than 0.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dimensional analysis was employed to develop a predictive formula for the terminal velocity for a magnet dropped down a metallic tube. In this particular application, the technique succeeded in generating the same formula theoretically derived and that has been published by others. The analysis thus presented suggests other applications that can be developed for motivating in the use of the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to analyze the influence of ultrasonic activation of calcium hydroxide (CH) pastes on pH and calcium release in simulated external root resorptions. Methods: Forty-six bovine incisors had their canals cleaned and instrumented, and defects were created in the external middle third of the roots, which were then used for the study. The teeth were externally made impermeable, except for the defected area, and divided into the following 4 groups containing 10 samples each according to the CH paste and the use or not of the ultrasonic activation: group 1: propylene glycol without ultrasonic activation, group 2: distilled water without ultrasonic activation, group 3: propylene glycol with ultrasonic activation, and group 4: distilled water with ultrasonic activation. After filling the canals with the paste, the teeth were restored and individually immersed into flasks with ultrapure water. The samples were placed into other flasks after 7, 15, and 30 days so that the water pH level could be measured by means of a pH meter. Calcium release was measured by means of an atomic absorption spectrophotometer. Six teeth were used as controls. The results were statistically compared using the Kruskal-Wallis and Mann-Whitney U tests (P < .05). Results: For all periods analyzed, the pH level was found to be higher when the CH paste was activated with ultrasound. Calcium release was significantly greater (P < .05) using ultrasonic activation after 7 and 30 days. Conclusions: The ultrasonic activation of CH pastes favored a higher pH level and calcium release in simulated external root resorptions. (J Endod 2012;38:834-837)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background To establish the correlation between quantitative analysis based on B-mode ultrasound images of vulnerable carotid plaque and histological examination of the surgically removed plaque, on the basis of a videodensitometric digital texture characterization. Methods Twenty-five patients (18 males, mean age 67 ± 6.9 years) admitted for carotid endarterectomy for extracranial high-grade internal carotid artery stenosis (≥ 70% luminal narrowing) underwent to quantitative ultrasonic tissue characterization of carotid plaque before surgery. A computer software (Carotid Plaque Analysis Software) was developed to perform the videodensitometric analysis. The patients were divided into 2 groups according to symptomatology (group I, 15 symptomatic patients; and group II, 10 patients asymptomatic). Tissue specimens were analysed for lipid, fibromuscular tissue and calcium. Results The first order statistic parameter mean gray level was able to distinguish the groups I and II (p = 0.04). The second order parameter energy also was able to distinguish the groups (p = 0,02). A histological correlation showed a tendency of mean gray level to have progressively greater values from specimens with < 50% to >75% of fibrosis. Conclusion Videodensitometric computer analysis of scan images may be used to identify vulnerable and potentially unstable lipid-rich carotid plaques, which are less echogenic in density than stable or asymptomatic, more densely fibrotic plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Experimental studies demonstrate that infection with trypanosoma cruzi causes vasculitis. The inflammatory lesion process could hypothetically lead to decreased distensibility of large and small arteries in advanced Chagas' disease. We tested this hypothesis. Methods and results We evaluated carotid-femoral pulse-wave velocity (PWV) in 53 Chagas' disease patients compared with 31 healthy volunteers (control group). The 53 patients were classified into 3 groups: 1) 16 with indeterminate form of Chagas' disease; 2) 18 with Chagas' disease, electrocardiographic abnormalities, and normal systolic function; 3) 19 with Chagas' disease, systolic dysfunction, and mild-to-moderate congestive heart failure. No difference was noted between the 4 groups regarding carotid-femoral PWV (8.4 ± 1.1 vs 8.2 ± 1.5 vs 8.2 ± 1.4 vs 8.7 ± 1.6 m/s, P = 0.6) or pulse pressure (39.5 ± 7.6 vs 39.3 ± 8.1 vs 39.5 ± 7.4 vs 39.7 ± 6.9 mm Hg, P = 0.9). A positive, significant, similar correlation occurred between PWV and age in patients with Chagas' disease (r = 0.42, P = 0.002), in controls (r = 0.48, P = 0.006), and also between PWV and systolic blood pressure in both groups (patients with Chagas' disease, r = 0.38, P = 0.005; healthy subjects, r = 0.36, P = 0.043). Conclusion Carotid femoral pulse-wave velocity is not modified in patients with Chagas' disease, suggesting that elastic properties of large arteries are not affected in this disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study compared different ultrasonic vibration modes for intraradicular cast post removal. The crowns of 24 maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the canals were treated endodontically. The post holes were prepared and root canal impressions were taken with self-cured resin acrylic. After casting, the posts were cemented with zinc phosphate cement. The samples were randomly distributed into 3 groups (n=8): G1: no ultrasonic vibration (control); G2: tip of the ultrasonic device positioned perpendicularly to core surface and close to the incisal edge; and G3: tip of the ultrasonic device positioned perpendicularly to core surface at cervical region, close to the line of cementation. An Enac OE-5 ultrasound unit with an ST-09 tip was used. All samples were submitted to the tensile test using an universal testing machine at a crosshead speed of 1 mm/min. Data were subjected to one-way ANOVA and Tukey's post-hoc tests (α=0.05). Mean values of the load to dislodge the posts (MPa) were: G1 = 4.6 (± 1.4) A; G2 = 2.8 (± 0.9) B, and G3= 0.9 (± 0.3) C. Therefore, the ultrasonic vibration applied with the tip of device close to the core's cervical area showed higher ability to reduce the retention of cast post to root canal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, structural composites manufactured by carbon fiber/epoxy laminates have been employed in large scale in aircraft industries. These structures require high strength under severe temperature changes of -56° until 80 °C. Regarding this scenario, the aim of this research was to reproduce thermal stress in the laminate plate developed by temperature changes and tracking possible cumulative damages on the laminate using ultrasonic C-scan inspection. The evaluation was based on attenuation signals and the C-scan map of the composite plate. The carbon fiber/epoxy plain weave laminate underwent temperatures of -60° to 80 °C, kept during 10 minutes and repeated for 1000, 2000, 3000 and 4000 times. After 1000 cycles, the specimens were inspected by C-scanning. A few changes in the laminate were observed using the inspection methodology only in specimens cycled 3000 times, or so. According to the found results, the used temperature range did not present enough conditions to cumulative damage in this type of laminate, which is in agreement with the macro - and micromechanical theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We deal with homogeneous isotropic turbulence and use the two-point velocity correlation tensor field (parametrized by the time variable t) of the velocity fluctuations to equip an affine space K3 of the correlation vectors by a family of metrics. It was shown in Grebenev and Oberlack (J Nonlinear Math Phys 18:109–120, 2011) that a special form of this tensor field generates the so-called semi-reducible pseudo-Riemannian metrics ds2(t) in K3. This construction presents the template for embedding the couple (K3, ds2(t)) into the Euclidean space R3 with the standard metric. This allows to introduce into the consideration the function of length between the fluid particles, and the accompanying important problem to address is to find out which transformations leave the statistic of length to be invariant that presents a basic interest of the paper. Also we classify the geometry of the particles configuration at least locally for a positive Gaussian curvature of this configuration and comment the case of a negative Gaussian curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]A comprehensive description of ocean molecular flow and deformation is provided with the help of hydrodynamic and ultrasonic principles. Hydrodynamic computation of true or natural viscosities shows that ocean shear viscosity (?G), compression viscosity (?K), and extensional viscosity (?E) are interrelated. There are no experimental methods available for the in situ measurement of these viscosities. Sound absorption coefficients (? obs) allow to know the ultrasonic shear (?UG), compression (?UK), and longitudinal (?L) viscosities, which decrease with increasing frequency and increase with increasing temperature, the flow activation energies having nearly equivalent values; pressure (depth) increase/decrease them at low/high frequencies. The viscosities ?* UG, ?* UK, ?* L are approached at about 1000 KHz. They decrease with temperature and pressure, and increase with salinity. The ?*UG becomes equal to the true shear viscosity ? G at the viscosity ratio ? = ?UK / ?UG = 0.