942 resultados para Ultra wideband
Resumo:
A novel hybrid three-phase rectifier is proposed. It is capable to achieve high input power factor (PF) and low total harmonic input currents distortion (THDI). The proposed hybrid high power rectifier is composed by a standard three-phase six-pulse diode rectifier (Graetz bridge) with a parallel connection of single-phase Sepic rectifiers in each three-phase rectifier leg. Such topology results in a structure capable of programming the input current waveform and providing conditions for obtaining high input power factor and low harmonic current distortion. In order to validate the proposed hybrid rectifier, this work describes its principles, with detailed operation, simulation, experimental results, and discussions on power rating of the required Sepic converters as related to the desired total harmonic current distortion. It is demonstrated that only a fraction of the output power is processed through the Sepic converters, making the proposed solution economically viable for very high power installations, with fast investment payback. Moreover, retrofitting to existing installations is also feasible since the parallel path can be easily controlled by integration with the existing dc-link. A prototype has been implemented in the laboratory and it was fully demonstrated to both operate with excellent performance and be feasibly implemented in higher power applications.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effects of ultrasound on the wound healing process after teeth extractions were studied histologically. The right upper incisor was extracted in 56 rats. They were divided into 2 groups, one control (I) and one experimental (II). Group II received ultrasound stimulation that was applied with the frequency of repetition of 1,000 Hz and pulse length of 2,000 us continuously, during five minutes daily since the extraction day until 24 hours before the death. The rats were sacrificed at 3, 6, 9, 12, 15, 18, and 21 postoperative days. The results showed a precocious granulation tissue formation, faster remodeling of osseous ridges, and consequently acceleration of the alveolar wound healing process.
Resumo:
This paper deals with the ultrastructural study of mature vampire bat Sertoli cells and their relationships with the different stages of testicular germ cells. In vampire bat seminiferous epithelium there are different types of junctional specializations among Sertoli cells and among Sertoli cells and different germ cells, with special emphasis to tight junctions and to junctions like as desmosomes. Ectoplasmic junctions through the Sertoli cells, including the smooth ER, are observed. These cellular interactions and their cytophysiological roles are discussed. Also are related some ultrastructural peculiarities of the Sertoli cell nucleus, nucleolus, cytoplasmic organelles and lipidic inclusions.
Resumo:
Ultra-fine NaNbO3 powder was prepared by the use of polymeric precursors. X-ray diffraction (XRD) results showed that this niobate nucleates from the amorphous precursor, with no intermediate phases, at low temperature (500°C). Studies by XRD and nitrogen adsorption/desorption showed that powders with high crystallinity ( ≈ 100%) and high surface areas (>20 m2/g) are obtained after calcination at 700°C for 5 h. Compacts of calcined powders showed high sinterability reaching 98% of theoretical density when sintered at 1190°C for 3 h.
Resumo:
A linearly-tunable ULV transconductor featuring excellent stability of the processed signal common-mode voltage upon tuning, critical for very-low voltage applications, is presented. Its employment to the synthesis of CMOS gm-C high-frequency and voiceband filters is discussed. SPICE data describe the filter characteristics. For a 1.3 V-supply, their nominal passband frequencies are 1.0 MHz and 3.78 KHz, respectively, with tuning rates of 12.52 KHz/mV and 0.16 KHz/m V, input-referred noise spectral density of 1.3 μV/Hz1/2 and 5.0μV/Hz1/2 and standby consumption of 0.87 mW and 11.8 μW. Large-signal distortion given by THD = 1% corresponds to a differential output-swing of 360 mVpp and 480 mVpp, respectively. Common-mode voltage deviation is less than 4 mV over tuning interval.
Resumo:
BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.
Resumo:
This study aimed to relate embryonic/fetal vesicle diameter (EVD) and crown-rump length (CRL) to gestational age in ewes from the 15 th to the 45 th day of pregnancy. Nineteen adult Bergamácia ewes with synchronized estrus were mated by the same male. Ultrasonographic evaluations were performed every 24 hours from the 15 th to the 30 th day after mating and every five days from the 30 th to the 45 th day using 5.0 and 7.5MHZ linear transducers. Average daily growth of EVD and CRL were 1.40mm and 1.33mm, respectively. The inverse calibration obtained for EVD was: Days = -11 + 50(0.1 + 0.04log EVD) 1/2 with R 2 = 0.85, and for CRL was: Days = 13.63 + 12.5(- 0.71 + 0.16CRL) 1/2 with R 2 = 0.93. Both EVD and CRL obtained by ultrasonography are useful measurements that allow the prediction of gestational age in Bergamácia ewes.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A novel hybrid high power rectifier capable to achieve unity power factor is proposed in this paper. Single-phase SEPIC rectifiers are associated in parallel with each leg of three-phase 6-pulse diode rectifier resulting in a programmable input current waveform structure. In this paper it is described the principles of operation of the proposed converter with detailed simulation and experimental results. For a total harmonic distortion of the input line current (THDI) less than 2% the rated power of the SEPIC rectifiers is 33%. Therefore, power rating of the SEPIC parallel converters is a fraction of the output power, on the range of 20% to 33% of the nominal output power, making the proposed solution economically viable for high power installations, with fast pay back of the investment. Moreover, retrofits to existing installations are also possible with this proposed topology, since the parallel path can be easily controlled by integration with the already existing de-link. Experimental results are presented for a 3 kW implemented prototype, in order to verify the developed analysis.
Resumo:
The objective of this work was to study the macroscopic, ultrasonographic and histopathologic aspects from the newly formed cicatricial tissue at the site of the partial resection of the long digital extensor tendon in 10 equines at the moment of functional restoration of the limb with the animal in walk locomotion. The macroscopic exam was performed every 48 hours, the planimetric mensuration every 10 days, the ultrasonographic exam every 15 days and the histopathologyc exam at the end of the study. The wounds showed granulation tissue in retraction, without total lesion epithelization, and the aspects ultrasonographics revealed wound healing with newly formed tissues with variable density and high neovascularization without tendon structural reorganization. The histopathology showed newly formed vascularized tissue, with leukocytic infiltrate and collagenous deposition without full epithelization. The cicatrization tissue formed in the resection region of the tendon, immature and without the structural organization of the normal tendon, showed to be able to functional restoration of the operated limb.