997 resultados para Tomografia computadorizada multislice


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the influence of metallic dental artifacts on the accuracy of simulated mandibular lesion detection by using multislice technology. MATERIAL AND METHODS: Fifteen macerated mandibles were used. Perforations were done simulating bone lesions and the mandibles were subjected to axial 16 rows multislice CT images using 0.5 mm of slice thickness with 0.3 mm interval of reconstruction. Metallic dental restorations were done and the mandibles were subjected again to CT in the same protocol. The images were analyzed to detect simulated lesions in the mandibles, verifying the loci number and if there was any cortical perforation exposing medullar bone. The analysis was performed by two independent examiners using e-film software. RESULTS: The samples without artifacts presented better results compared to the gold standard (dried mandible with perforations). In the samples without artifacts, all cortical perforation were identified and 46 loci were detected (of 51) in loci number analysis. Among the samples with artifacts, 12 lesions out of 14 were recognized regarding medullar invasion, and 40 out of 51 concerning loci number. The sensitivity in samples without artifacts was 90% and 100% regarding loci number and medullar invasion, respectively. In samples with artifacts, these values dropped to 78% and 86%, respectively. The presence of metallic restorations affected the sensitivity values of the method, but the difference was not significant (p>0.05). CONCLUSIONS: Although there were differences in the results of samples with and without artifacts, the presence of metallic restoration did not lead to misinterpretation of the final diagnosis. However, the validity of multislice CT imaging in this study was established for detection of simulated mandibular bone lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional radiography has shown limitation in acquiring image of the ATM region, thus, computed tomography (CT) scanning has been the best option to the present date for diagnosis, surgical planning and treatment of bone lesions, owing to its specific properties. OBJECTIVE: The aim of the study was to evaluate images of simulated bone lesions at the head of the mandible by multislice CT. MATERIAL AND METHODS: Spherical lesions were made with dental spherical drills (sizes 1, 3, and 6) and were evaluated by using multislice CT (64 rows), by two observers in two different occasions, deploying two protocols: axial, coronal, and sagittal images, and parasagittal images for pole visualization (anterior, lateral, posterior, medial and superior). Acquired images were then compared with those lesions in the dry mandible (gold standard) to evaluate the specificity and sensibility of both protocols. Statistical methods included: Kappa statistics, validity test and chi-square test. Results demonstrated the advantage of associating axial, coronal, and sagittal slices with parasagittal slices for lesion detection at the head of the mandible. RESULTS: There was no statistically significant difference between the types of protocols regarding a particular localization of lesions at the poles. CONCLUSIONS: Protocols for the assessment of the head of the mandible were established to improve the visualization of alterations of each of the poles of the mandible's head. The anterior and posterior poles were better visualized in lateral-medial planes while lateral, medial and superior poles were better visualized in the anterior-posterior plane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Identificar os principais sintomas e sinais ao exame vestibular computadorizado em pacientes na menopausa. Método: Foram examinadas 24 pacientes com idades entre 46 a 66 anos. Analisaram-se os dados relativos à sintomatologia e achados ao exame vestibular computadorizado com vectonistagmografia realizado no ambulatório de otoneurologia da Irmandade Santa Casa de Misericórdia de São Paulo, em 2004 e 2005. Resultados: Entre as pacientes, 54,1 por cento faziam reposição hormonal. Em relação aos sintomas relatados, observamos cefaléia (58,4 por cento), hipersensibilidade a sons intensos (58,4 por cento), tontura (54,2 por cento), zumbido (50 por cento), hipoacusia (50 por cento), ansiedade (50 por cento), distúrbio neurovegetativo (41,7 por cento), vertigem (37,5 por cento) e depressão (37,5 por cento). Ao exame vestibular encontramos alterações do nistagmo de posicionamento (12,5 por cento), e prova calórica (54,2 por cento). Na conclusão do exame tivemos prevalência de síndrome vestibular periférica irritativa (54,2 por cento). Conclusão: Por meio dos resultados desta pesquisa concluiu-se que pacientes no período da menopausa apresentam elevada prevalência de sintoma otoneurológicos e alterações à vectonistagmografia computadorizada, com predomínio de síndrome vestibular periférica do tipo irritativo

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voz traqueoesofágica (VTE) com prótese fonatória (PF) é método eficaz e reproduzível na reabilitação vocal após laringectomia total (LT), impedida pelo espasmo do segmento faringoesofágico (SFE). A manometria computadorizada (MC) é novo método objetivo e direto de avaliação do SFE. OBJETIVO: Análise objetiva do espasmo do SFE, com MC, antes e após aplicação de toxina botulínica (TB). DESENHO DO ESTUDO: Prospectivo clínico. MATERIAL E MÉTODOS: Análise de oito pacientes consecutivos submetidos à LT com VTE e PF, sem emissão vocal, com espasmo do SFE à videofluoroscopia, considerado padrão ouro para detecção de espasmo. Todos trataram o espasmo com injeção de 100 unidades de TB no SFE. Avaliação constituiu-se de videofluoroscopia e MC do SFE, antes e após aplicação de TB. RESULTADOS: Houve diminuição na pressão do SFE à MC, após injeção de TB em todos. A média de pressão do SFE à MC, nos oito pacientes, antes da aplicação de TB foi de 25.36 mmHg e após foi de 14.31 mmHg (p=0,004). Houve emissão vocal sem esforço e melhora do espasmo do SFE à videofluoroscopia após o uso da TB. CONCLUSÃO: Foi observada diminuição na pressão do SFE após injeção da TB à MC em todos os pacientes, com melhora do espasmo à videofluoroscopia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado de Radiações aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações