997 resultados para Tire Thermal Aspects.
Resumo:
Thermal analysis, powder diffraction, and Raman scattering as a function of the temperature were carried out on K2BeF4. Moreover, the crystal structure was determined at 293 K from powder diffraction. The compound shows a transition from Pna21 to Pnam space group at 921 K with a transition enthalpy of 5 kJ/mol. The transition is assumed to be first order because the compound shows metastability. Structurally and spectroscopically the transition is similar to those observed in (NH4)2SO4, which suggests that the low-temperature phase is ferroelectric. In order to confirm it, the spontaneous polarization has been computed using an ionic model.
Resumo:
This paper presents a thermal modeling for power management of a new three-dimensional (3-D) thinned dies stacking process. Besides the high concentration of power dissipating sources, which is the direct consequence of the very interesting integration efficiency increase, this new ultra-compact packaging technology can suffer of the poor thermal conductivity (about 700 times smaller than silicon one) of the benzocyclobutene (BCB) used as both adhesive and planarization layers in each level of the stack. Thermal simulation was conducted using three-dimensional (3-D) FEM tool to analyze the specific behaviors in such stacked structure and to optimize the design rules. This study first describes the heat transfer limitation through the vertical path by examining particularly the case of the high dissipating sources under small area. First results of characterization in transient regime by means of dedicated test device mounted in single level structure are presented. For the design optimization, the thermal draining capabilities of a copper grid or full copper plate embedded in the intermediate layer of stacked structure are evaluated as a function of the technological parameters and the physical properties. It is shown an interest for the transverse heat extraction under the buffer devices dissipating most the power and generally localized in the peripheral zone, and for the temperature uniformization, by heat spreading mechanism, in the localized regions where the attachment of the thin die is altered. Finally, all conclusions of this analysis are used for the quantitative projections of the thermal performance of a first demonstrator based on a three-levels stacking structure for space application.
Resumo:
Whereas numerical modeling using finite-element methods (FEM) can provide transient temperature distribution in the component with enough accuracy, it is of the most importance the development of compact dynamic thermal models that can be used for electrothermal simulation. While in most cases single power sources are considered, here we focus on the simultaneous presence of multiple sources. The thermal model will be in the form of a thermal impedance matrix containing the thermal impedance transfer functions between two arbitrary ports. Eachindividual transfer function element ( ) is obtained from the analysis of the thermal temperature transient at node ¿ ¿ after a power step at node ¿ .¿ Different options for multiexponential transient analysis are detailed and compared. Among the options explored, small thermal models can be obtained by constrained nonlinear least squares (NLSQ) methods if the order is selected properly using validation signals. The methods are applied to the extraction of dynamic compact thermal models for a new ultrathin chip stack technology (UTCS).
Resumo:
The clinical and radiological data of 52 patients with subarachnoid haemorrhage (SAH) and a negative panangiography were analysed with an average follow-up period of 3.8 years. Of these 52 patients, only one (1.9%) was subsequently found to have an aneurysm. Second angiography proved to be inconclusive in all 24 cases where it was performed. Of the 51 'true' non-aneurysmal SAH, 80% were in a good clinical grade on admission and 12% developed cerebral ischaemia. The mortality rate following SAH was 4%. There was one rebleeding. At follow-up examination, 87% of the patients had made a good recovery and 6% were left disabled due to SAH. Four patients with an aneurysmal pattern of SAH required a permanent shunt. All of the 22 patients with a perimesencephalic SAH were in a good neurological condition upon admission; one of them developed an angiography-induced transient cerebral ischaemia and another one suffered from a fatal rebleeding. None of the 21 survivors was disabled at follow-up examination. The clinical course of patients with SAH of unknown cause, especially those with a perimesencephalic pattern of haemorrhage, is good. Repeated angiography in this latter group is not useful. In the aneurysmal pattern SAH group, repeat angiography is advised only if there is strong computed tomographic (CT) scan suspicion of an aneurysm.
Resumo:
We predict the existence of an anomalous crossover between thermal and shot noise in macroscopic diffusive conductors. We first show that, besides thermal noise, these systems may also exhibit shot noise due to fluctuations of the total number of carriers in the system. Then we show that at increasing currents the crossover between the two noise behaviors is anomalous, in the sense that the low-frequency current spectral density displays a region with a superlinear dependence on the current up to a cubic law. The anomaly is due to the nontrivial coupling in the presence of the long-range Coulomb interaction among the three time scales relevant to the phenomenon, namely, diffusion, transit, and dielectric relaxation time.
Resumo:
Within a drift-diffusion model we investigate the role of the self-consistent electric field in determining the impedance field of a macroscopic Ohmic (linear) resistor made by a compensated semi-insulating semiconductor at arbitrary values of the applied voltage. The presence of long-range Coulomb correlations is found to be responsible for a reshaping of the spatial profile of the impedance field. This reshaping gives a null contribution to the macroscopic impedance but modifies essentially the transition from thermal to shot noise of a macroscopic linear resistor. Theoretical calculations explain a set of noise experiments carried out in semi-insulating CdZnTe detectors.
Resumo:
The study of the thermal behavior of complex packages as multichip modules (MCM¿s) is usually carried out by measuring the so-called thermal impedance response, that is: the transient temperature after a power step. From the analysis of this signal, the thermal frequency response can be estimated, and consequently, compact thermal models may be extracted. We present a method to obtain an estimate of the time constant distribution underlying the observed transient. The method is based on an iterative deconvolution that produces an approximation to the time constant spectrum while preserving a convenient convolution form. This method is applied to the obtained thermal response of a microstructure as analyzed by finite element method as well as to the measured thermal response of a transistor array integrated circuit (IC) in a SMD package.
Resumo:
Progress in the understanding of the hepatitis C virus life cycle allowed the development of new, very promising antiviral therapies. Although these new drugs have a favourable profile in terms of efficacy, tolerance and interaction potential, their prescription in the setting of comedication and impaired renal or hepatic function remains a challenge. Here, we provide a summary of pharmacological considerations, focusing on sofosbuvir, simeprevir and daclatasvir. A better understanding of their metabolic pathways and transporters may help the prescriber to identify and manage drug interactions especially in patients under immunosuppressive or anti-HIV therapy. Recommendations for the prescription of these drugs in specific situations are also discussed.
Resumo:
The removal of the litter layer in Portuguese pine forests would reduce fire hazard, but on the other hand this practice would influence the thermal regime of the soil, hence affecting soil biological activity, litter decomposition and nutrient dynamics. Temperature profiles of a sandy soil (Haplic Podzol) under a pine forest were measured with thermocouples at depths to 16 cm, with and without litter layer. The litter layer acted as a thermal insulator, reducing the amplitude of the periodic temperature variation in the mineral soil underneath and increasing damping depths, particularly at low soil water contents. At the mineral soil surface the reduction of amplitudes was about 2.5 ºC in the annual cycle and 5 to 6.7 ºC in the daily cycle, depending on the soil water content. When soil was both cold and wet, mean daily soil temperatures were higher (about 1 - 1.5 ºC) under the litter layer. Improved soil thermal conditions under the litter layer recommend its retention as a forest management practice to follow in general.
Resumo:
Two trends which presently exist in relation to the concept of Paleontology are analyzed, pointing out some of the aspects which negative influence. Various reflections are made based on examples of some of the principal points of paleontological method, such as the influence of a punctual sampling, the meaning of size-frequency distribution and subjectivity in the identification of fossils. Topics which have a marked repercussion in diverse aspects of Paleontology are discussed.