904 resultados para TOTAL HIP
Resumo:
The neutron-rich nucleus Li-11 is separated by the radioactive ion beam line RIBLL at HIRFL from the breakup of 50MeV/u C-13 on Be target. The total reaction cross sections for Li-11 at energies range from 25 to 45MeV/u on Si target have been measured by using the transmission method. The experimental data at high and low energies can be fitted well by Glauber model using two Gauss density distribution. The matter radius of Li-11 was also deduced.
Resumo:
The mirror nuclei N-12 and B-12 are separated by the Radioactive Ion Beam Line in Lanzhou (RIBLL) at HIRFL from the breakup of 78.6 MeV/u N-14 on a Be target. The total reaction cross-sections of N-12 at 34.9 MeV/u and B-12 at 54.4 MeV/u on a Si target have been measured by using the transmission method. Assuming N-12 consists of a C-11 core plus one halo proton, the excitation function of N-12 and B-12 on a Si target and a C target were calculated with the Glauber model. It can fit the experimental data very well. The characteristic halo structure for N-12 was found with a large diffusion of the protons density distribution.
Resumo:
In the present paper is reported the method for the isolation and extraction of total flavonoids of Epimedium Koreanum Nakai by means of supercritical fluid extraction (SFE). By examining pressure, temperature. amounts of modifier and extraction time, the optimized condition of SFE is confirmed as 30 MPa and 60 degreesC. with 70% ethanol as the modifier. The samples were statically extracted for 30 min, followed by dynamic extraction for 120 min at a flow rate of 6 mL/min. The quantitative analysis of total flavonoids was performed by UV-Vis spectrophotometry. Compared with the conventional method, the SFE method is more efficient. more rapid and more friendly environmentally.
Resumo:
We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.
Resumo:
Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL), The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6) mu g ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6) mu g ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4) mu g ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved in underground water during water treatment. (C) 1997 Elsevier Science B.V.