902 resultados para System for energy certification of buildings
Resumo:
A regional hydrogeochemical model was developed to evaluate the geochemical evolution of different groundwaters in an alluvial aquifer system in the Interior of Oman. In combination with environmental isotopes the model is able to extract qualitative and quantitative information about recharge, groundwater flow paths and hydraulic connections between different aquifers. The main source of water to the alluvial aquifer along the flow paths ofWadi Abyadh andWadi M’uaydin in the piedmont is groundwater from the high-altitude areas of the Jabal Akhdar and local infiltration along the wadi channels. In contrast, the piedmont alluvial aquifer alongWadi Halfayn is primarily replenished by lateral recharge from the ophiolite foothills to the east besides smaller contributions from the Jabal Akhdar and local infiltration. Further down gradient in the Southern Alluvial Plain aquifer a significant source of recharge is direct infiltration of rain and surface runoff, originating from a moisture source that approaches Oman from the south. The model shows that the main geochemical evolution of the alluvial groundwaters occurs along the flow path from the piedmont to the Southern Alluvial Plain, where dedolomitization is responsible for the observed changes in the chemical and carbon isotope composition in these waters.
Resumo:
OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).
Resumo:
Luminescence and energy transfer in [Zn1-xRux(bpy)3][NaAl1-yCry(ox)3] (x ≈ 0.01, y = 0.006 − 0.22; bpy = 2,2‘-bipyridine, ox = C2O42-) and [Zn1-x-yRuxOsy(bpy)3][NaAl(ox)3] (x ≈ 0.01, y = 0.012) are presented and discussed. Surprisingly, the luminescence of the isolated luminophores [Ru(bpy)3]2+ and [Os(bpy)3]2+ in [Zn(bpy)3][NaAl(ox)3] is hardly quenched at room temperature. Steady-state luminescence spectra and decay curves show that energy transfer occurs between [Ru(bpy)3]2+ and [Cr(ox)3]3- and between [Ru(bpy)3]2+ and [Os(bpy)3]2+ in [Zn1-xRux(bpy)3][NaAl1-yCry(ox)3] and [Zn1-x-yRuxOsy(bpy)3] [NaAl(ox)3], respectively. For a quantitative investigation of the energy transfer, a shell type model is developed, using a Monte Carlo procedure and the structural parameters of the systems. A good description of the experimental data is obtained assuming electric dipole−electric dipole interaction between donors and acceptors, with a critical distance Rc for [Ru(bpy)3]2+ to [Cr(ox)3]3- energy transfer of 15 Å and for [Ru(bpy)3]2+ to [Os(bpy)3]2+ energy transfer of 33 Å. These values are in good agreement with those derived using the Förster−Dexter theory.
Resumo:
A number of liquid argon time projection chambers (LAr TPCs) are being built or are proposed for neutrino experiments on long- and short baseline beams. For these detectors, a distortion in the drift field due to geometrical or physics reasons can affect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity, this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration, multiple coulomb scattering and momentum uncertainties allow only a limited resolution. A UV laser instead can create straight ionization tracks in liquid argon, and allows one to map the drift field along different paths in the TPC inner volume. Here we present a UV laser feed-through design with a steerable UV mirror immersed in liquid argon that can point the laser beam at many locations through the TPC. The straight ionization paths are sensitive to drift field distortions, a fit of these distortion to the linear optical path allows to extract the drift field, by using these laser tracks along the whole TPC volume one can obtain a 3D drift field map. The UV laser feed-through assembly is a prototype of the system that will be used for the MicroBooNE experiment at the Fermi National Accelerator Laboratory (FNAL).
Resumo:
Cardiac allograft vasculopathy (CAV) is a form of accelerated atherosclerosis, which represents the leading cause of late morbidity and mortality after heart transplantation. The recent bioresorbable vascular scaffold (BVS) technology represents a potential novel therapeutic tool, in the context of CAV, by allowing transient scaffolding and concomitant vessel healing. Eligible subjects will be treated by using the Absorb Everolimus-Eluting BVS (Abbott Vascular, Santa Clara, CA, USA), and evaluated at pre-determined time points, up to 3 years since the index procedure. Both clinical and imaging data will be collected in dedicated case report forms (CRF). All imaging data will be analyzed in an independent core laboratory. The primary aim of the study is to evaluate the angiographic performance at 1 year of second-generation Absorb BVS, in heart transplant recipients affected by CAV.
Resumo:
Clinical observations made by practitioners and reported using web- and mobile-based technologies may benefit disease surveillance by improving the timeliness of outbreak detection. Equinella is a voluntary electronic reporting and information system established for the early detection of infectious equine diseases in Switzerland. Sentinel veterinary practitioners have been able to report cases of non-notifiable diseases and clinical symptoms to an internet-based platform since November 2013. Telephone interviews were carried out during the first year to understand the motivating and constraining factors affecting voluntary reporting and the use of mobile devices in a sentinel network. We found that non-monetary incentives attract sentinel practitioners; however, insufficient understanding of the reporting system and of its relevance, as well as concerns over the electronic dissemination of health data were identified as potential challenges to sustainable reporting. Many practitioners are not yet aware of the advantages of mobile-based surveillance and may require some time to become accustomed to novel reporting methods. Finally, our study highlights the need for continued information feedback loops within voluntary sentinel networks.
Resumo:
Background: Diabetes mellitus is spreading throughout the world and diabetic individuals have been shown to often assess their food intake inaccurately; therefore, it is a matter of urgency to develop automated diet assessment tools. The recent availability of mobile phones with enhanced capabilities, together with the advances in computer vision, have permitted the development of image analysis apps for the automated assessment of meals. GoCARB is a mobile phone-based system designed to support individuals with type 1 diabetes during daily carbohydrate estimation. In a typical scenario, the user places a reference card next to the dish and acquires two images using a mobile phone. A series of computer vision modules detect the plate and automatically segment and recognize the different food items, while their 3D shape is reconstructed. Finally, the carbohydrate content is calculated by combining the volume of each food item with the nutritional information provided by the USDA Nutrient Database for Standard Reference. Objective: The main objective of this study is to assess the accuracy of the GoCARB prototype when used by individuals with type 1 diabetes and to compare it to their own performance in carbohydrate counting. In addition, the user experience and usability of the system is evaluated by questionnaires. Methods: The study was conducted at the Bern University Hospital, “Inselspital” (Bern, Switzerland) and involved 19 adult volunteers with type 1 diabetes, each participating once. Each study day, a total of six meals of broad diversity were taken from the hospital’s restaurant and presented to the participants. The food items were weighed on a standard balance and the true amount of carbohydrate was calculated from the USDA nutrient database. Participants were asked to count the carbohydrate content of each meal independently and then by using GoCARB. At the end of each session, a questionnaire was completed to assess the user’s experience with GoCARB. Results: The mean absolute error was 27.89 (SD 38.20) grams of carbohydrate for the estimation of participants, whereas the corresponding value for the GoCARB system was 12.28 (SD 9.56) grams of carbohydrate, which was a significantly better performance ( P=.001). In 75.4% (86/114) of the meals, the GoCARB automatic segmentation was successful and 85.1% (291/342) of individual food items were successfully recognized. Most participants found GoCARB easy to use. Conclusions: This study indicates that the system is able to estimate, on average, the carbohydrate content of meals with higher accuracy than individuals with type 1 diabetes can. The participants thought the app was useful and easy to use. GoCARB seems to be a well-accepted supportive mHealth tool for the assessment of served-on-a-plate meals.
Resumo:
The purpose of this research and development project was to develop a method, a design, and a prototype for gathering, managing, and presenting data about occupational injuries.^ State-of-the-art systems analysis and design methodologies were applied to the long standing problem in the field of occupational safety and health of processing workplace injuries data into information for safety and health program management as well as preliminary research about accident etiologies. The top-down planning and bottom-up implementation approach was utilized to design an occupational injury management information system. A description of a managerial control system and a comprehensive system to integrate safety and health program management was provided.^ The project showed that current management information systems (MIS) theory and methods could be applied successfully to the problems of employee injury surveillance and control program performance evaluation. The model developed in the first section was applied at The University of Texas Health Science Center at Houston (UTHSCH).^ The system in current use at the UTHSCH was described and evaluated, and a prototype was developed for the UTHSCH. The prototype incorporated procedures for collecting, storing, and retrieving records of injuries and the procedures necessary to prepare reports, analyses, and graphics for management in the Health Science Center. Examples of reports, analyses, and graphics presenting UTHSCH and computer generated data were included.^ It was concluded that a pilot test of this MIS should be implemented and evaluated at the UTHSCH and other settings. Further research and development efforts for the total safety and health management information systems, control systems, component systems, and variable selection should be pursued. Finally, integration of the safety and health program MIS into the comprehensive or executive MIS was recommended. ^
Resumo:
This paper examines whether or not the export insurance subsidy provided by the British government has promoted Britain.s export supply. Unlike previous studies on the effectiveness of export subsidy in export supply, the current study examines the stationarity nature of the concerned variables. The unit root tests show that all concerned variables are integrated of order one. According to Johansen cointegration test, the concerned variables are not cointegrated. The empirical evidences using the first differenced data show that the export subsidy in terms of provision of export insurances by the government is not statistically significant in increasing export supply.