981 resultados para Strength mean values


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Knowledge on the relative importance of alternative sources of human campylobacteriosis is important in order to implement effective disease prevention measures. The objective of this study was to assess the relative importance of three key exposure pathways (travelling abroad, poultry meat, pet contact) for different patient age groups in Switzerland. With a stochastic exposure model data on Campylobacter incidence for the years 2002-2007 were linked with data for the three exposure pathways and the results of a case-control study. Mean values for the population attributable fractions (PAF) over all age groups and years were 27% (95% CI 17-39) for poultry consumption, 27% (95% CI 22-32) for travelling abroad, 8% (95% CI 6-9) for pet contact and 39% (95% CI 25-50) for other risk factors. This model provided robust results when using data available for Switzerland, but the uncertainties remained high. The output of the model could be improved if more accurate input data are available to estimate the infection rate per exposure. In particular, the relatively high proportion of cases attributed to 'other risk factors' requires further attention.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In zebrafish, two isoforms of the aromatase gene exist, namely cyp19a1 and cyp19a2, expressed predominantly in the gonads and brain, respectively. In this study, we focus on characterizing the specificity of antibodies against the aromatase isoforms, and on (xeno)estrogen-induced changes of individual cyp19a2 mRNA concentrations in the brains of adult male zebrafish. Among three polyclonal antibodies studied, the one against CYP19A2 was found to be specific in Western blots and immunohistochemistry. Real-time RT-PCR analyses revealed strong interindividual variation of cyp19a2 levels in the brains of adult male zebrafish. After a three-week-exposure to (xeno)estrogens, mean values of cyp19a2 mRNA levels tended to increase, with significant induction at 200 ng 17beta-estradiol/L, but interindividual variation of cyp19a2 expression was maintained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Vitamin D is essential for calcium metabolism as well as for fracture prevention, and a recent review suggested that the optimal serum 25(OH)D lies in the region of 50-80 nmol L-1 (20-32 ng mL-1). A high prevalence of inadequacy has been reported in many studies but the prevalence of inadequacy amongst women with osteoporosis in different regions of the world has not been well characterized. SETTING AND SUBJECTS: A multinational study of 18 countries at various latitudes (range 64N-38S) was conducted in 2004 and 2005 to determine the average levels of serum 25(OH)D and the prevalence of vitamin D inadequacy. A total of 2606 postmenopausal women with osteoporosis (low bone mineral density, history of fragility fracture) seeking routine medical care were enrolled and serum 25(OH)D levels were measured at a single laboratory visit. RESULTS: Mean serum 25(OH)D level was 26.8 ng mL-1 (SE 0.3) and ranged from 7 to 243 ng mL-1. Regional mean values were highest in Latin America (29.6 ng mL-1, SE 0.6) and lowest in the Middle East (20.4 ng mL-1, SE 0.5). Overall, 64% of women had serum levels<30 ng mL-1. Serum parathyroid hormone reached a nadir at serum 25(OH)D levels>35 ng mL-1. In nonequatorial countries, women recruited during the winter months had somewhat lower serum 25(OH)D levels than those recruited during the summer months in some, but not all, countries. CONCLUSIONS: Low levels of serum 25(OH)D are common amongst women with osteoporosis. The results underscore the value of assuring vitamin D adequacy in these women.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: Sensory hypersensitivity, central hyperexcitability [lowered nociceptive flexion reflex (NFR) thresholds], and psychologic distress are features of chronic whiplash. However, relationships between these substrates are not clear. This study tested the hypothesis that psychologic distress and catastrophization are correlated with sensory hypersensitivity and NFR responses in chronic whiplash. METHODS: Pressure and thermal pain thresholds (mean values across 3 body sites), NFR threshold, and pain at threshold Visual Analog Scale were measured in 30 participants with chronic whiplash and 30 asymptomatic controls. Pain and disability levels Neck Disability Index, psychologic distress (GHQ-28), and catastrophization (PCS) were also measured in the whiplash group. RESULTS: Whiplash injured participants demonstrated lowered pain thresholds to pressure and cold (P<0.05); lowered NFR thresholds (P=0.003), and demonstrated above threshold levels of psychologic distress (GHQ-28) and levels of catastrophization comparable with other musculoskeletal conditions. There were no group differences for heat pain thresholds or pain at NFR threshold. In the whiplash group, PCS scores correlated moderately with cold pain threshold (r=0.51, P=0.01). In contrast, there were no significant correlations between GHQ-28 scores and pain threshold measures or between psychologic factors and NFR responses in whiplash participants. There were no significant correlations between psychologic factors and pain thresholds or NFR responses in controls. DISCUSSION: We have demonstrated that psychologic factors have some association with sensory hypersensitivity (cold pain threshold measures) in chronic whiplash but do not seem to influence spinal cord excitability. This suggests that psychologic disorders are important, but not the only, determinants of central hypersensitivity in whiplash patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rationale: To provide a better understanding of cognitive functioning, motor outcome, behavior and quality of life after childhood stroke and to study the relationship between variables expected to influence rehabilitation and outcome (age at stroke, time elapsed since stroke, lateralization, location and size of lesion). Methods: Children who suffered from stroke between birth and their eighteenth year of life underwent an assessment consisting of cognitive tests (WISC-III, WAIS-R, K-ABC, TAP, Rey-Figure, German Version of the CVLT) and questionnaires (Conner's Scales, KIDSCREEN). Results: Twenty-one patients after stroke in childhood (15 males, mean 11;11 years, SD 4;3, range 6;10-21;2) participated in the study. Mean Intelligence Quotients (IQ) were situated within the normal range (mean Full Scale IQ 96.5, range IQ 79-129). However, significantly more patients showed deficits in various cognitive domains than expected from a healthy population (Performance IQ p = .000; Digit Span p = .000, Arithmetic's p = .007, Divided Attention p = .028, Alertness p = .002). Verbal IQ was significantly better than Performance IQ in 13 of 17 patients, independent of the hemispheric side of lesion. Symptoms of ADHD occurred more often in the patients' sample than in a healthy population (learning difficulties/inattention p = .000; impulsivity/hyperactivity p = .006; psychosomatics p = .006). Certain aspects of quality of life were reduced (autonomy p = .003; parents' relation p = .003; social acceptance p = .037). Three patients had a right-sided hemiparesis, mean values of motor functions of the other patients were slightly impaired (sequential finger movements p = .000, hand alternation p = .001, foot tapping p = .043). In patients without hemiparesis, there was no relation between the lateralization of lesion and motor outcome. Lesion that occurred in the midst of childhood (5-10 years) led to better cognitive outcome than lesion in the very early (0-5 years) or late childhood (10-18 years). Other variables such as presence of seizure, elapsed time since stroke and size of lesion had a small to no impact on prognosis. Conclusion: Moderate cognitive and motor deficits, behavioral problems, and impairment in some aspects of quality of life frequently remain after stroke in childhood. Visuospatial functions are more often reduced than verbal functions, independent of the hemispheric side of lesion. This indicates a functional superiority of verbal skills compared to visuospatial skills in the process of recovery after brain injury. Compared to the cognitive outcome following stroke in adults, cognitive sequelae after childhood stroke do indicate neither the lateralization nor the location of the lesion focus. Age at stroke seems to be the only determining factor influencing cognitive outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Ultra-high-field whole-body systems (7.0 T) have a high potential for future human in vivo magnetic resonance imaging (MRI). In musculoskeletal MRI, biochemical imaging of articular cartilage may benefit, in particular. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping have shown potential at 3.0 T. Although dGEMRIC, allows the determination of the glycosaminoglycan content of articular cartilage, T2 mapping is a promising tool for the evaluation of water and collagen content. In addition, the evaluation of zonal variation, based on tissue anisotropy, provides an indicator of the nature of cartilage ie, hyaline or hyaline-like articular cartilage.Thus, the aim of our study was to show the feasibility of in vivo dGEMRIC, and T2 and T2* relaxation measurements, at 7.0 T MRI; and to evaluate the potential of T2 and T2* measurements in an initial patient study after matrix-associated autologous chondrocyte transplantation (MACT) in the knee. MATERIALS AND METHODS: MRI was performed on a whole-body 7.0 T MR scanner using a dedicated circular polarization knee coil. The protocol consisted of an inversion recovery sequence for dGEMRIC, a multiecho spin-echo sequence for standard T2 mapping, a gradient-echo sequence for T2* mapping and a morphologic PD SPACE sequence. Twelve healthy volunteers (mean age, 26.7 +/- 3.4 years) and 4 patients (mean age, 38.0 +/- 14.0 years) were enrolled 29.5 +/- 15.1 months after MACT. For dGEMRIC, 5 healthy volunteers (mean age, 32.4 +/- 11.2 years) were included. T1 maps were calculated using a nonlinear, 2-parameter, least squares fit analysis. Using a region-of-interest analysis, mean cartilage relaxation rate was determined as T1 (0) for precontrast measurements and T1 (Gd) for postcontrast gadopentate dimeglumine [Gd-DTPA(2-)] measurements. T2 and T2* maps were obtained using a pixelwise, monoexponential, non-negative least squares fit analysis; region-of-interest analysis was carried out for deep and superficial cartilage aspects. Statistical evaluation was performed by analyses of variance. RESULTS: Mean T1 (dGEMRIC) values for healthy volunteers showed slightly different results for femoral [T1 (0): 1259 +/- 277 ms; T1 (Gd): 683 +/- 141 ms] compared with tibial cartilage [T1 (0): 1093 +/- 281 ms; T1 (Gd): 769 +/- 150 ms]. Global mean T2 relaxation for healthy volunteers showed comparable results for femoral (T2: 56.3 +/- 15.2 ms; T2*: 19.7 +/- 6.4 ms) and patellar (T2: 54.6 +/- 13.0 ms; T2*: 19.6 +/- 5.2 ms) cartilage, but lower values for tibial cartilage (T2: 43.6 +/- 8.5 ms; T2*: 16.6 +/- 5.6 ms). All healthy cartilage sites showed a significant increase from deep to superficial cartilage (P < 0.001). Within healthy cartilage sites in MACT patients, adequate values could be found for T2 (56.6 +/- 13.2 ms) and T2* (18.6 +/- 5.3 ms), which also showed a significant stratification. Within cartilage repair tissue, global mean values showed no difference, with 55.9 +/- 4.9 ms for T2 and 16.2 +/- 6.3 ms for T2*. However, zonal assessment showed only a slight and not significant increase from deep to superficial cartilage (T2: P = 0.174; T2*: P = 0.150). CONCLUSION: In vivo T1 dGEMRIC assessment in healthy cartilage, and T2 and T2* mapping in healthy and reparative articular cartilage, seems to be possible at 7.0 T MRI. For T2 and T2*, zonal variation of articular cartilage could also be evaluated at 7.0 T. This zonal assessment of deep and superficial cartilage aspects shows promising results for the differentiation of healthy and affected articular cartilage. In future studies, optimized protocol selection, and sophisticated coil technology, together with increased signal at ultra-high-field MRI, may lead to advanced biochemical cartilage imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose was to evaluate the relative glycosaminoglycan (GAG) content of repair tissue in patients after microfracturing (MFX) and matrix-associated autologous chondrocyte transplantation (MACT) of the knee joint with a dGEMRIC technique based on a newly developed short 3D-GRE sequence with two flip angle excitation pulses. Twenty patients treated with MFX or MACT (ten in each group) were enrolled. For comparability, patients from each group were matched by age (MFX: 37.1 +/- 16.3 years; MACT: 37.4 +/- 8.2 years) and postoperative interval (MFX: 33.0 +/- 17.3 months; MACT: 32.0 +/- 17.2 months). The Delta relaxation rate (DeltaR1) for repair tissue and normal hyaline cartilage and the relative DeltaR1 were calculated, and mean values were compared between both groups using an analysis of variance. The mean DeltaR1 for MFX was 1.07 +/- 0.34 versus 0.32 +/- 0.20 at the intact control site, and for MACT, 1.90 +/- 0.49 compared to 0.87 +/- 0.44, which resulted in a relative DeltaR1 of 3.39 for MFX and 2.18 for MACT. The difference between the cartilage repair groups was statistically significant. The new dGEMRIC technique based on dual flip angle excitation pulses showed higher GAG content in patients after MACT compared to MFX at the same postoperative interval and allowed reducing the data acquisition time to 4 min.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The impact of a filtering half-face respirator and a half-face supplied air respirator use on blood lactate production was assessed during maximal exertion to determine if anaerobic strain increased compared to no respirator use. Twenty-eight participants performed a 30 second cycling Wingate anaerobic test (WAnT) wearing a half-face respirator. Blood lactate production was measured to evaluate if there was an increase in anaerobic strain from wearing a tight fitting half-face respirator compared to wearing no respirator. A supplied air respirator WAnT was then performed using 18 participants from the first experiment to evaluate if supplied air decreased anaerobic strain. Data from both experiments were compared to evaluate differences in the physiological effects due to respirator use during maximal exertion. A survey was administered following the second WAnT experiment to measure the participants' perception of acceptability and impact of supplied air respirator use in workplace. The blood lactate levels measured directly after the WAnT yielded lower overall mean values during the half-mask respirator trial (12.1 mmollL) and supplied air respirator trial (12.2 mmollL) than the no respirator trial (13.1 mmoI/L). However, differences in blood lactate levels were not statistically significant (p =0.597). Participants reported an average acceptability of 92.3% to wearing the supplied air respirator while performing light work. However, the average acceptability decreased as the exertion increased to moderate (78.8%) and heavy (46.6%) workloads. The supplied air respirator used provided no significant reduction in anaerobic strain within this study group compared to either the filtering half-face respirator or the no respirator condition. However, there were differences in physiological effects of respirators on each gender identified in this study. Further assessment of the anaerobic impact of respirators on each gender should be conducted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Little is known about the population's exposure to radio frequency electromagnetic fields (RF-EMF) in industrialized countries. OBJECTIVES: To examine levels of exposure and the importance of different RF-EMF sources and settings in a sample of volunteers living in a Swiss city. METHODS: RF-EMF exposure of 166 volunteers from Basel, Switzerland, was measured with personal exposure meters (exposimeters). Participants carried an exposimeter for 1 week (two separate weeks in 32 participants) and completed an activity diary. Mean values were calculated using the robust regression on order statistics (ROS) method. RESULTS: Mean weekly exposure to all RF-EMF sources was 0.13 mW/m(2) (0.22 V/m) (range of individual means 0.014-0.881 mW/m(2)). Exposure was mainly due to mobile phone base stations (32.0%), mobile phone handsets (29.1%) and digital enhanced cordless telecommunications (DECT) phones (22.7%). Persons owning a DECT phone (total mean 0.15 mW/m(2)) or mobile phone (0.14 mW/m(2)) were exposed more than those not owning a DECT or mobile phone (0.10 mW/m(2)). Mean values were highest in trains (1.16 mW/m(2)), airports (0.74 mW/m(2)) and tramways or buses (0.36 mW/m(2)), and higher during daytime (0.16 mW/m(2)) than nighttime (0.08 mW/m(2)). The Spearman correlation coefficient between mean exposure in the first and second week was 0.61. CONCLUSIONS: Exposure to RF-EMF varied considerably between persons and locations but was fairly consistent within persons. Mobile phone handsets, mobile phone base stations and cordless phones were important sources of exposure in urban Switzerland.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To study the three-dimensional (3D) T1 patterns in different types of femoroacetabular impingement (FAI) by utilizing delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) and subsequent 3D T1 mapping. We used standard grading of OA by Tonnis grade on standard radiographs and morphological grading of cartilage in MRI for comparative analysis. METHODS: dGEMRIC was obtained from ten asymptomatic young-adult volunteers and 26 symptomatic FAI patients. MRI included the routine hip protocol and a dual-flip angle (FA) 3D gradient echo (GRE) sequence utilizing inline T1 measurement. Cartilage was morphologically classified from the radial images based on the extent of degeneration as: no degeneration, degeneration zone measuring <0.75 cm from the rim, >0.75 cm, or total loss. T1 findings were evaluated and correlated. RESULTS: All FAI types revealed remarkably lower T1 mean values in comparison to asymptomatic volunteers in all regions of interest. Distribution of the T1 dGEMRIC values was in accordance with the specific FAI damage pattern. In cam-types (n=6) there was a significant drop (P<0.05) of T1 in the anterior to superior location. In pincer-types (n=7), there was a generalized circumferential decrease noted. High inter-observer (intra-observer) reliability was noted for T1 assessment using intra-class correlation (ICC):intra-class coefficient=0.89 (0.95). CONCLUSIONS: We conclude that a pattern of zonal T1 variation does seem to exist that is unique for different sub-groups of FAI. The FA GRE approach to perform 3D T1 mapping has a promising role for further studies of standard MRI and dGEMRIC in the hip joint.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: This study examined the course of low-back pain over 52 weeks following current pain at baseline. Initial beliefs about the inevitability of the pain's negative consequences and fear avoidance beliefs were examined as potential risk factors for persistent low-back pain. METHODS: On a weekly basis over a period of one year, 264 participants reported both the intensity and frequency of their low-back pain and the degree to which it impaired their work performance. In a multilevel regression analysis, predictor variables included initial low-back pain intensity, age, gender, body mass index, anxiety/depression, participation in sport, heavy workload, time (1-52 weeks), and scores on the "back beliefs" and "fear-avoidance beliefs" questionnaires. RESULTS: The group mean values for both the intensity and frequency of weekly low-back pain, and the impairment of work performance due to such pain showed a recovery within the first 12 weeks. In a multilevel regression of 9497 weekly measurements, greater weekly low-back pain and impairment were predicted by higher levels of work-related fear avoidance beliefs. A significant interaction between time and the scores on both the work-related fear-avoidance and back beliefs questionnaires indicated faster recovery and pain relief over time in those who reported less fear-avoidance and fewer negative beliefs. CONCLUSIONS: Negative beliefs about the inevitability of adverse consequences of low-back pain and work-related, fear-avoidance beliefs are independent risk factors for poor recovery from low-back pain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: To validate the concept of early implant placement for use in the esthetically sensitive anterior maxilla, clinical trials should ideally include objective esthetic criteria when assessing outcome parameters. METHODS: In this cross-sectional, retrospective 2- to 4-year study involving 45 patients treated with maxillary anterior single-tooth implants according to the concept of early implant placement, a novel comprehensive index, comprising pink esthetic score and white esthetic score (PES/WES; the highest possible combined score is 20), was applied for the objective esthetic outcome assessment of anterior single-tooth implants. RESULTS: All 45 anterior maxillary single-tooth implants fulfilled strict success criteria for dental implants with regard to osseointegration, including the absence of peri-implant radiolucency, implant mobility, suppuration, and pain. The mean total PES/WES was 14.7 +/- 1.18 (range: 11 to 18). The mean total PES of 7.8 +/- 0.88 (range: 6 to 9) documents favorable overall peri-implant soft tissue conditions. The two PES variables facial mucosa curvature (1.9 +/- 0.29) and facial mucosa level (1.8 +/- 0.42) had the highest mean values, whereas the combination variable root convexity/soft tissue color and texture (1.2 +/- 0.53) proved to be the most difficult to fully satisfy. Mean scores were 1.6 +/- 0.5 for the mesial papilla and 1.3 +/- 0.5 for the distal papilla. A mean value of 6.9 +/- 1.47 (range: 4 to 10) was calculated for WES. CONCLUSIONS: This study demonstrated that anterior maxillary single-tooth replacement, according to the concept of early implant placement, is a successful and predictable treatment modality, in general, and from an esthetic point of view, in particular. The suitability of the PES/WES index for the objective outcome assessment of the esthetic dimension of anterior single-tooth implants was confirmed. However, prospective clinical trials are needed to further validate and refine this index.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Quantitative reverse transcriptase real-time PCR (QRT-PCR) is a robust method to quantitate RNA abundance. The procedure is highly sensitive and reproducible as long as the initial RNA is intact. However, breaks in the RNA due to chemical or enzymatic cleavage may reduce the number of RNA molecules that contain intact amplicons. As a consequence, the number of molecules available for amplification decreases. We determined the relation between RNA fragmentation and threshold values (Ct values) in subsequent QRT-PCR for four genes in an experimental model of intact and partially hydrolyzed RNA derived from a cell line and we describe the relation between RNA integrity, amplicon size and Ct values in this biologically homogenous system. We demonstrate that degradation-related shifts of Ct values can be compensated by calculating delta Ct values between test genes and the mean values of several control genes. These delta Ct values are less sensitive to fragmentation of the RNA and are unaffected by varying amounts of input RNA. The feasibility of the procedure was demonstrated by comparing Ct values from a larger panel of genes in intact and in partially degraded RNA. We compared Ct values from intact RNA derived from well-preserved tumor material and from fragmented RNA derived from formalin-fixed, paraffin-embedded (FFPE) samples of the same tumors. We demonstrate that the relative abundance of gene expression can be based on FFPE material even when the amount of RNA in the sample and the extent of fragmentation are not known.