936 resultados para Straight Tenckhoff catheter
Resumo:
BACKGROUND: Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS: In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS: The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS: Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones.
Resumo:
Käyttäjäkeskeinen ohjelmistokehityson nimensä mukaisesti käyttäjän tarpeista ja vaatimuksista lähtevä ohjelmistojen kehittämistapa. Tällä tavoin halutaan saada selville, millaisia vaikutusmahdollisuuksia hän haluaa. Työ käsittelee tähän perustuvaa toteutusta, jolla käyttäjät voivat toteuttaa eksplisiittistä personointia eli toisin sanoen voivat muokataitse omaa henkilökohtaista tietoaan. Käyttäjille tarjotaan mahdollisuus vaikuttaa tapauskohtaisesti, kuinka hän käyttää personointitietojaan. Työssä luodaan avoimen lähdekoodin väliohjelmistoalustalle (MUPE) personointitiedon kustomointityökalu ja sitä hyödyntävät havainnollistavat palvelut. Tämän pohjana on aikaisemmin suoritettu informaation keruu. Naiden toteutuksien avulla on luotu käyttötapausesimerkkejä, joista voidaan havaita erilaisten personointitietojen käytön vaikutukset käyttäjän kannalta. Työkalun ja havainnollistavien palvelujen avulla luodut esimerkit tarjoavat hyvän ja kestävän pohjan sekä kustomointityökalun että käyttötapausesimerkkien laajentamiselle. Naita esimerkkejä voidaan myös jo suoraan soveltaa todellisissa käyttäjäkeskeisissä kenttätutkimuksissa.
Resumo:
We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.
Resumo:
OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.
Resumo:
Despite the rapid change in today's business environment there are relatively few studies about corporate renewal. This study aims for its part at filling that research gap by studying the concepts of strategy, corporate renewal, innovation and corporate venturing. Its purpose is to enhance our understanding of how established companies operating in dynamic and global environment can benefit from their corporate venturing activities. The theoretical part approaches the research problem in corporate and venture levels. Firstly, it focuses on mapping the determinants of strategy and suggests using industry, location, resources, knowledge, structure and culture, market, technology and business model to assess the environment and using these determinants to optimize speed and magnitude of change.Secondly, it concludes that the choice of innovation strategy is dependent on the type and dimensions of innovation and suggests assessing market, technology, business model as well as novelty and complexity related to each of them for choosing an optimal context for developing innovations further. Thirdly, it directsattention on processes through which corporate renewal takes place. On corporate level these processes are identified as strategy formulation, strategy formation and strategy implementation. On the venture level the renewal processes are identified as learning, leveraging and nesting. The theoretical contribution of this study, the framework of strategic corporate venturing, joins corporate and venture level management issues together and concludes that strategy processes and linking processes are the mechanism through which continuous corporate renewaltakes place. The framework of strategic corporate venturing proposed by this study is a new way to illustrate the role of corporate venturing as a purposefullybuilt, different view of a company's business environment. The empirical part extended the framework by enhancing our understanding of the link between corporate renewal and corporate venturing in its real life environment in three Finnish companies: Metso, Nokia and TeliaSonera. Characterizing companies' environmentwith the determinants of strategy identified in this study provided a structured way to analyze their competitive position and renewal challenges that they arefacing. More importantly the case studies confirmed that a link between corporate renewal and corporate venturing exists and found out that the link is not as straight forward as indicated by the theory. Furthermore, the case studies enhanced the framework by indicating a sequence according to which the processes work. Firstly, the induced strategy processes strategy formulation and strategy implementation set the scene for corporate venturing context and management processes and leave strategy formation for the venture. Only after that can strategies formed by ventures come back to the corporate level - and if found viable in the corporate level be formalized through formulation and implementation. With the help of the framework of strategic corporate venturing the link between corporaterenewal and corporate venturing can be found and managed. The suggested response to the continuous need for change is continuous renewal i.e. institutionalizing corporate renewal in the strategy processes of the company. As far as benefiting from venturing is concerned the answer lies in deliberately managing venturing in a context different to the mainstream businesses and establishing efficientlinking processes to exploit the renewal potential of individual ventures.
Resumo:
Small centrifugal compressors are more and more widely used in many industrialsystems because of their higher efficiency and better off-design performance comparing to piston and scroll compressors as while as higher work coefficient perstage than in axial compressors. Higher efficiency is always the aim of the designer of compressors. In the present work, the influence of four partsof a small centrifugal compressor that compresses heavy molecular weight real gas has been investigated in order to achieve higher efficiency. Two parts concern the impeller: tip clearance and the circumferential position of the splitter blade. The other two parts concern the diffuser: the pinch shape and vane shape. Computational fluid dynamics is applied in this study. The Reynolds averaged Navier-Stokes flow solver Finflo is used. The quasi-steady approach is utilized. Chien's k-e turbulence model is used to model the turbulence. A new practical real gas model is presented in this study. The real gas model is easily generated, accuracy controllable and fairly fast. The numerical results and measurements show good agreement. The influence of tip clearance on the performance of a small compressor is obvious. The pressure ratio and efficiency are decreased as the size of tip clearance is increased, while the total enthalpy rise keeps almost constant. The decrement of the pressure ratio and efficiency is larger at higher mass flow rates and smaller at lower mass flow rates. The flow angles at the inlet and outlet of the impeller are increased as the size of tip clearance is increased. The results of the detailed flow field show that leakingflow is the main reason for the performance drop. The secondary flow region becomes larger as the size of tip clearance is increased and the area of the main flow is compressed. The flow uniformity is then decreased. A detailed study shows that the leaking flow rate is higher near the exit of the impeller than that near the inlet of the impeller. Based on this phenomenon, a new partiallyshrouded impeller is used. The impeller is shrouded near the exit of the impeller. The results show that the flow field near the exit of the impeller is greatly changed by the partially shrouded impeller, and better performance is achievedthan with the unshrouded impeller. The loading distribution on the impeller blade and the flow fields in the impeller is changed by moving the splitter of the impeller in circumferential direction. Moving the splitter slightly to the suction side of the long blade can improve the performance of the compressor. The total enthalpy rise is reduced if only the leading edge of the splitter ismoved to the suction side of the long blade. The performance of the compressor is decreased if the blade is bended from the radius direction at the leading edge of the splitter. The total pressure rise and the enthalpy rise of thecompressor are increased if pinch is used at the diffuser inlet. Among the fivedifferent pinch shape configurations, at design and lower mass flow rates the efficiency of a straight line pinch is the highest, while at higher mass flow rate, the efficiency of a concave pinch is the highest. The sharp corner of the pinch is the main reason for the decrease of efficiency and should be avoided. The variation of the flow angles entering the diffuser in spanwise direction is decreased if pinch is applied. A three-dimensional low solidity twisted vaned diffuser is designed to match the flow angles entering the diffuser. The numerical results show that the pressure recovery in the twisted diffuser is higher than in a conventional low solidity vaned diffuser, which also leads to higher efficiency of the twisted diffuser. Investigation of the detailed flow fields shows that the separation at lower mass flow rate in the twisted diffuser is later than in the conventional low solidity vaned diffuser, which leads to a possible wider flow range of the twisted diffuser.
Resumo:
This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.
Resumo:
En Riegel v. Medtronic Inc. (552 U.S.__2008; February 20, 2008), el Sr. Riegel tuvo que ser sometido a un by-pass como consecuencia de la rotura del catéter, fabricado por Medtronic, con el que su médico le practicaba una angioplastia. A pesar de que el catéter había obtenido la autorización de comercialización de la FDA y cumplía los requisitos de seguridad previstos por el sistema regulatorio federal, el Sr. Riegel y su mujer interpusieron una acción de daños contra Medtronic –y no contra el médico- conforme a las reglas de responsabilidad civil objetiva y por negligencia del Common Law neoyorquino. Sin embargo, el Tribunal Supremo federal de los EE.UU., en ponencia del Magistrado Antonin Gregory Scalia, votó, por mayoría de ocho magistrados, rechazar el recurso de la Sra. Riegel y confirmar la sentencia de segunda instancia, desestimatoria de la demanda, porque consideró que la regla de primacía del derecho regulatorio federal sobre seguridad de productos sanitarios [Medical Device Amendments de 1976, 21 U.S.C. Artículo 360k(a)] excluye la aplicabilidad no sólo del derecho regulatorio estatal sobre seguridad de productos sanitarios, sino también del Common Law sobre responsabilidad civil del fabricante.
Resumo:
This work describes the analysis of different walking paths registered using a Light Detection And Ranging (LIDAR) laser range sensor in order to measure oscillating trajectories during unsupervised walking. The estimate of the gait and trajectory parameters were obtained with a terrestrial LIDAR placed 100 mm above the ground with the scanning plane parallel to the floor to measure the trajectory of the legs without attaching any markers or modifying the floor. Three different large walking experiments were performed to test the proposed measurement system with straight and oscillating trajectories. The main advantages of the proposed system are the possibility to measure several steps and obtain average gait parameters and the minimum infrastructure required. This measurement system enables the development of new ambulatory applications based on the analysis of the gait and the trajectory during a walk.
Resumo:
The EAUN Guidelines Working Group for indwelling catheters have prepared this guideline document to help nurses assess the evidence-based management of catheter care and to incorporate the guidelines’ recommendations into their clinical practice. These guidelines are not meant to be proscriptive, nor will adherence to these guidelines guarantee a successful outcome in all cases. Ultimately, decisions regarding care must be made on a case-by-case basis by healthcare professionals after consultation with their patients using their clinical judgement, knowledge and expertise.
Resumo:
Severe acute refractory respiratory failure is considered a life-threatening situation, with a high mortality of 40 to 60%. When conservative oxygenation methods fail, a lifesaving measure is the introduction of extracorporeal membrane oxygenation (ECMO). Venovenous ECMO (VV-ECMO) is a preferred modality of support for patients with refractory acute respiratory failure. Specifically, bicaval VV-ECMO is a well-recognized and validated therapy, where single or double periphery venous access is used for the insertion of two differently sized cannulas in order to achieve adequate blood oxygenation. Compared to venoarterial ECMO, in VV-ECMO, the rate of complications, such as thrombosis, bleeding, infection and ischemic events, is lower. On the other hand, the size and insertion location is an obstacle to patient mobilization. This is a considerable problem for patients where the time interval for lung recovery and the bridge to the transplantation is prolonged. To address this issue, a dual-lumen, single venovenous cannula was introduced. Here, by insertion of one single catheter in one target vessel, in a majority of cases in the right internal jugular vein, satisfactory oxygenation of the patient is achieved. In this form, the instituted VV-ECMO enables patient mobility, better physical rehabilitation and facilitates pulmonary extubation and toilet. However, relatively early, after the first short-term reports were published, a relatively high complication rate became evident. In the recent literature, the complication rate using actual commercially available double-lumen venovenous cannula ranges between 5 and 30%. These cases were mostly conjoined to the implantation phase or the early postoperative phase and vary between right heart perforation to migration of the cannula. This review focuses on complications allied to commercially available dual-lumen, single, venovenous cannula implantation, pointing out the critical segments of the implantation process and analyzing the structure of the device.
Resumo:
PURPOSE: (1) To assess the outcomes of minimally invasive simple prostatectomy (MISP) for the treatment of symptomatic benign prostatic hyperplasia in men with large prostates and (2) to compare them with open simple prostatectomy (OSP). METHODS: A systematic review of outcomes of MISP for benign prostatic hyperplasia with meta-analysis was conducted. The article selection process was conducted according to the PRISMA guidelines. RESULTS: Twenty-seven observational studies with 764 patients were analyzed. The mean prostate volume was 113.5 ml (95 % CI 106-121). The mean increase in Qmax was 14.3 ml/s (95 % CI 13.1-15.6), and the mean improvement in IPSS was 17.2 (95 % CI 15.2-19.2). Mean duration of operation was 141 min (95 % CI 124-159), and the mean intraoperative blood loss was 284 ml (95 % CI 243-325). One hundred and four patients (13.6 %) developed a surgical complication. In comparative studies, length of hospital stay (WMD -1.6 days, p = 0.02), length of catheter use (WMD -1.3 days, p = 0.04) and estimated blood loss (WMD -187 ml, p = 0.015) were significantly lower in the MISP group, while the duration of operation was longer than in OSP (WMD 37.8 min, p < 0.0001). There were no differences in improvements in Qmax, IPSS and perioperative complications between both procedures. The small study sizes, publication bias, lack of systematic complication reporting and short follow-up are limitations. CONCLUSIONS: MISP seems an effective and safe treatment option. It provides similar improvements in Qmax and IPSS as OSP. Despite taking longer, it results in less blood loss and shorter hospital stay. Prospective randomized studies comparing OSP, MISP and laser enucleation are needed to define the standard surgical treatment for large prostates.
Resumo:
Aquest article presenta i estudia un conjunt de cobles de la tradició oral recollides a la Conca de Barberà i al Priorat. Les cançons, creades en el marc de la Restauració, denuncien un conjunt de greuges lligats al caciquisme i al desenvolupament de l’Estat i de les relacions capitalistes que aquest fomenta. Les cobles presenten dos grans registres expressius, que obeeixen a diferents perspectives dels greuges que denuncien. D’una banda tenim unes cobles caracteritzades per una sàtira violenta, dreturera, una sintaxi cantelluda, antítesis primàries, i un recurs viu a les deformacions de l’adversari. En aquests casos, les lletres obeeixen a factors percebuts en la immediatesa de la comunitat, d’acord amb una perspectiva tradicional. D’altra banda, tenim cobles que es caracteritzen per un relaxament còmic i jocós de la sàtira, per una major narrativitat o arromançament, i també per una catarsi benèfica. En aquests casos, les cançons responen a un nou ordre de factors —polítics/política de partit, representants de l’Estat, noves modes estètiques, etc.— que en la societat rural, especialment entre aquells sectors poc introduïts a la modernitat, són percebuts amb una amplitud panoràmica, d’acord amb una ingenuïtat perceptiva, amb un distanciament naïf cap a la realitat. Es tracta d’un ordre de percepcions que informen els trets expressius que hem apuntat quant a aquestes cobles. Unes manifestacions ben il·lustratives d’aquestes darreres composicions són unes contrautopies que recullen, amb voluntat de totalitat, el conjunt d’abusos que pateix la societat pagesa, general o local.
Resumo:
The aim of this study was to examine the effects of oxidising BIMODES microbiological control program on three paper machine process. The chemicals used in BIMODES program are sodium hypochlorite (NaOCl) and bromo-chloro-di-methyl-hydantoin (BCDMH). The literary part of this study discusses the microbiological problems in paper making industry, describes functional mechanisms of oxidants and also introduces the BIMODES- program. In the experimental part the aim was to examine the effects of BIMODES in three different paper machines. The purpose was to find out the effects and changes in wet end chemistry, bacterial counts, in the other additives and also in the sheet defects and holes. The study also examines what are the most important measurements to control BIMODES dosing. In addition the optimal dosing level for each machine was tried to find out. It was found that there is a clear correlation between the total chlorine level and bacterial counts. Changes in the BIMODES dosing level can be measured by redox potential, but the correlation is very poor. BIMODES program doesn’t have straight influence to pH values, but if dosage level is too low the bacterial activity can affect degreasing in the pH value. In this study couldn’t find any consequential effects for the other additives by using BIMODES. In addition the optimal dosing levels were found and by following correct halogen levels it is possible to decrease bacterial levels for very low level.
Resumo:
PURPOSE: Implanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques. METHODS AND MATERIALS: Through a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new "mechanical adhesiolysis" maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication. RESULTS: Eighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted. CONCLUSION: These IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.