910 resultados para Semigroup of linear operators
Resumo:
Bettini et al (2006 Nat. Nanotechnol. 1 182-5) reported the first experimental realization of linear atomic chains (LACs) composed of different atoms (Au and Ag). The different contents of Au and Ag were observed in the chains from what was found in the bulk alloys, which raises the question of what the wire composition is, if it is in equilibrium with a bulk alloy. In this work we address the thermodynamic driving force for species fractionation in LACs under tension, and we present the density-functional theory results for Ag-Au chain alloys. A pronounced stabilization of the wires with an alternating Ag-Au sequence is observed, which could be behind the experimentally observed Au enrichment in LACs from alloys with high Ag content.
Resumo:
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Foram utilizados 1.015 frangos de corte machos, linhagem Ross, dos 37 aos 49 dias de idade, para avaliar os efeitos de diferentes níveis de lisina digestível nas dietas experimentais. O delineamento experimental foi inteiramente casualizado, com 5 níveis de lisina digestível (0,90; 0,95; 1,00; 1,05; 1,10%), cada um com 7 repetições e 29 aves por unidade experimental. Utilizaram-se dietas isoenergéticas com 3.250 de kcal de EM/kg e isoprotéicas, com 18% de PB, à base de milho e farelo de soja. Foram avaliados o ganho de peso, o consumo de ração, a conversão alimentar, as características de carcaça, o rendimento de cortes, a composição e a deposição de nutrientes corporais. Os níveis de lisina digestível influenciaram, entre as características de desempenho, apenas a conversão alimentar, que melhorou de forma linear de acordo com níveis de lisina da ração. Das características de carcaça e rendimento de cortes, apenas gordura abdominal aumentou de forma quadrática conforme os níveis de lisina. Os níveis de lisina digestível tiveram efeito quadrático no teor da matéria mineral da carcaça, mas não influenciaram a composição química das vísceras e do sangue. Observou-se, contudo, tendência a aumento linear na deposição de proteína da carcaça e do corpo vazio com o aumento no nível de lisina digestível. Os resultados de desempenho indicam que o nível de lisina digestível da ração de frangos de corte machos no período de 37 a 49 dias de idade deve ser igual ou superior a 1,10%.
Resumo:
The existence of a classical limit describing the interacting particles in a second-quantized theory of identical particles with bosonic symmetry is proved. This limit exists in addition to the previously established classical limit with a classical field behavior, showing that the limit h -> 0 of the theory is not unique. An analogous result is valid for a free massive scalar field: two distinct classical limits are proved to exist, describing a system of particles or a classical field. The introduction of local operators in order to represent kinematical properties of interest is shown to break the permutation symmetry under some localizability conditions, allowing the study of individual particle properties.
Resumo:
We apply techniques of zeta functions and regularized products theory to study the zeta determinant of a class of abstract operators with compact resolvent, and in particular the relation with other spectral functions.
Resumo:
We derive a new implementation of linear covariant gauges on the lattice, based on a minimizing functional that can be interpreted as the Hamiltonian of a spin-glass model in a random external magnetic field. We show that our method solves most problems encountered in earlier implementations, mostly related to the no-go condition formulated by Giusti [Nucl. Phys. B498, 331 (1997)]. We carry out tests in the SU(2) case in four space-time dimensions. We also present preliminary results for the transverse gluon propagator at different values of the gauge parameter xi.
Resumo:
This paper presents a controller design method for fuzzy dynamic systems based on piecewise Lyapunov functions with constraints on the closed-loop pole location. The main idea is to use switched controllers to locate the poles of the system to obtain a satisfactory transient response. It is shown that the global fuzzy system satisfies the requirements for the design and that the control law can be obtained by solving a set of linear matrix inequalities, which can be efficiently solved with commercially available softwares. An example is given to illustrate the application of the proposed method. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
This work presents an automated system for the measurement of form errors of mechanical components using an industrial robot. A three-probe error separation technique was employed to allow decoupling between the measured form error and errors introduced by the robotic system. A mathematical model of the measuring system was developed to provide inspection results by means of the solution of a system of linear equations. A new self-calibration procedure, which employs redundant data from several runs, minimizes the influence of probes zero-adjustment on the final result. Experimental tests applied to the measurement of straightness errors of mechanical components were accomplished and demonstrated the effectiveness of the employed methodology. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The macrocyclic compounds (6-(4',6'-diamino-1',3',5'-triazinyl)-1,4,6,8,11-pentaazacyclotetradecane)copper(II) triperchlorate dihydrate, [Cu(HL2)](ClO4)(3). 2H(2)O, (6-(6'-amino-4'-oxo-1'H-1',3',5'-triazinyl)-1,4,6,8,11-pentaazacyclotetradecane)copper(II) diperchlorate hydrate, [CuL3](ClO4)(2). H2O, and [(6-(4',6'-dioxo-1'H-1',3',5'-triazinyl) 1,4,6,8,11-pentaazacyclotetradecane)copper(II)] diperchlorate, [CuL4](ClO4)(2), have been synthesized. The macrocycles synthesized contain respectively pendant melamine, ammeline,and ammelide rings. The X-ray cyrstallographic analyses of [Cu(HL2)](ClO4)(3). 2H(2)O, triclinic, space group P (1) over bar, a = 9.489(10) Angstrom, b = 12.340(2) Angstrom, c = 24.496(4) Angstrom, alpha = 87.74(10)degrees beta = 85.51(10)degrees gamma = 70.95(10)degrees and Z = 4, and {[CuL3](ClO4)(2). H2O}2, monoclinic, space group C2/c, a = 18.624(8) Angstrom, b = 17.160(2) Angstrom, c = 15.998(6) Angstrom, beta = 117.82(2)degrees, and Z = 4, are reported. The structure of [Cu(HL2)](ClO4)(3). 2H(2)O shows the formation of linear tapes, formed by a combination of hydrogen bonds and pi-pi stacking interactions. The structure of [CuL3](ClO4)(2). H2O displays formation of dimers, formed by a coordinate bond from the oxygen in one molecule to the copper atom of another. The tautomeric forms of the ammeline and ammelide moieties have been determined. The potential of these compounds as subunits for cocrystallization has been investigated.
Resumo:
Expokit provides a set of routines aimed at computing matrix exponentials. More precisely, it computes either a small matrix exponential in full, the action of a large sparse matrix exponential on an operand vector, or the solution of a system of linear ODEs with constant inhomogeneity. The backbone of the sparse routines consists of matrix-free Krylov subspace projection methods (Arnoldi and Lanczos processes), and that is why the toolkit is capable of coping with sparse matrices of large dimension. The software handles real and complex matrices and provides specific routines for symmetric and Hermitian matrices. The computation of matrix exponentials is a numerical issue of critical importance in the area of Markov chains and furthermore, the computed solution is subject to probabilistic constraints. In addition to addressing general matrix exponentials, a distinct attention is assigned to the computation of transient states of Markov chains.
Resumo:
A synthetic Synechocystis sp. PCC6803 DnaB split mini-intein gene was constructed for the in vivo cyclization of recombinant proteins expressed in Escherichia coli. The system was used to cyclize the NH2-terminal domain of E. coli DnaB, the structure of which had been determined previously by NMR spectroscopy. Cyclization was found to proceed efficiently, with little accumulation of precursor, and the product was purified in high yield. The solution structure of cyclic DnaB-N is not significantly different from that of linear DnaB-N and it unfolds reversibly at temperatures similar to14 degreesC higher. Improved hydrogen bonding was observed in the first and last helices, and the length of the last helix was increased, while the 9-amino acid linker used to join the NH2 and COOH termini was found to be highly mobile. The measured thermodynamic stabilization of the structure (DeltaDeltaG approximate to 2 kcal/mol) agrees well with the value estimated from the reduced conformational entropy in the unfolded form. Simple polymer theory can be used to predict likely free energy changes resulting from protein cyclization and how the stabilization depends on the size of the protein and the length of the linker used to connect the termini.
Resumo:
Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.
Resumo:
The metallic voice is usually confused with ring or nasality by singers and nontrained listeners. who are not used to perceptual vocal analysis. They believe a metallic voice results from a rise in fundamental frequency. A diagnostic error in this aspect may lead to lowering pitch, an incorrect procedure that Could Cause vocal overload and fatigue. The purpose of this article is to Study the quality of metallic voice considering the correlation between information of the physiological and acoustic plans, based on a perceptive consensual assumption. Fiberscopic video pharyngolaryngoscopy was performed on 21 professional singers while speaking vowel [e]-in normal and metallic modes to observe muscular movements and structural changes of the velopharynx, pharynx, and larynx. Vocal samples captured simultaneously to the fiberscopic examination were acoustically analyzed. Frequency and amplitude of the first four formants (F(1), F(2), F(3), and F(4)) were extracted by means of linear predictor coefficients (LPC) Spectrum and were statistically analyzed. Vocal tract adjustments such as velar lowering, pharyngeal wall narrowing, laryngeal rise, aryepiglottic, and lateral laryngeal constrictions were frequently found: there were no significant changes in frequency and amplitude of F(1) in the metallic voiced there were significant increases in amplitudes of F(2), F(3), and F(4) and in frequency for F, metallic Voice perceived as louder was correlated to an increase ill amplitude of F(3) and F(4). Physiological adjustments of velopharynx, pharynx, and larynx are combined in characterizing the metallic voice and can be acoustically related to changes in formant pattern.