910 resultados para SMOKE DETECTORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes some aspects of multichannel spectrophotometry, principles of photodiode arrays and their applications in Analytical Chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large hadron collider constructed at the European organization for nuclear research, CERN, is the world’s largest single measuring instrument ever built, and also currently the most powerful particle accelerator that exists. The large hadron collider includes six different experiment stations, one of which is called the compact muon solenoid, or the CMS. The main purpose of the CMS is to track and study residue particles from proton-proton collisions. The primary detectors utilized in the CMS are resistive plate chambers (RPCs). To obtain data from these detectors, a link system has been designed. The main idea of the link system is to receive data from the detector front-end electronics in parallel form, and to transmit it onwards in serial form, via an optical fiber. The system is mostly ready and in place. However, a problem has occurred with innermost RPC detectors, located in sector labeled RE1/1; transmission lines for parallel data suffer from signal integrity issues over long distances. As a solution to this, a new version of the link system has been devised, a one that fits in smaller space and can be located within the CMS, closer to the detectors. This RE1/1 link system has been so far completed only partially, with just the mechanical design and casing being done. In this thesis, link system electronics for RE1/1 sector has been designed, by modifying the existing link system concept to better meet the requirements of the RE1/1 sector. In addition to completion of the prototype of the RE1/1 link system electronics, some testing for the system has also been done, to ensure functionality of the design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quantitative chemical analysis of the Brazilian sugar cane spirit distilled from glass column packaged with copper, stainless steel, aluminum sponge, or porcelain balls is described. The main chemical compounds determined by gas chromatography coupled with flame ionization (FID) and flame photometric (FPD) detectors and liquid chromatography coupled with diode array detector are aldehydes, ketones, carboxylic acids, alcohols, esters and dimethylsulfite (DMS). The spirits produced either in columns filled with copper or aluminum pot still exhibits the lowest DMS contents but the higher sulfate and methanol contents, whereas spirits produced in stainless steel or porcelain showed higher DMS concentration and lower teors of sulfate ion and methanol. These observations are coherent with DMS oxidation to sulfate, with methanol as by product, in the presence of either copper or aluminum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of gamma spectrometry and gamma and X-ray tomography of nuclear fuel is to determine both radionuclide concentration and integrity and deformation of nuclear fuel. The aims of this thesis have been to find out the basics of gamma spectrometry and tomography of nuclear fuel, to find out the operational mechanisms of gamma spectrometry and tomography equipment of nuclear fuel, and to identify problems that relate to these measurement techniques. In gamma spectrometry of nuclear fuel the gamma-ray flux emitted from unstable isotopes is measured using high-resolution gamma-ray spectroscopy. The production of unstable isotopes correlates with various physical fuel parameters. In gamma emission tomography the gamma-ray spectrum of irradiated nuclear fuel is recorded for several projections. In X-ray transmission tomography of nuclear fuel a radiation source emits a beam and the intensity, attenuated by the nuclear fuel, is registered by the detectors placed opposite. When gamma emission or X-ray transmission measurements are combined with tomographic image reconstruction methods, it is possible to create sectional images of the interior of nuclear fuel. MODHERATO is a computer code that simulates the operation of radioscopic or tomographic devices and it is used to predict and optimise the performance of imaging systems. Related to the X-ray tomography, MODHERATO simulations have been performed by the author. Gamma spectrometry and gamma and X-ray tomography are promising non-destructive examination methods for understanding fuel behaviour under normal, transient and accident conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Virtual Reality environments that reproduce typical contexts associated with tobacco use may be useful for aiding smoking cessation. The main objective of this study was to assess the capacity of eight environments to produce the craving to smoke and determine the relation of craving to nicotine dependence and level of presence. The results show that all the environments were able to generate the desire to smoke; a direct relation was found between sense of presence and craving.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cue exposure treatment (CET) consists of controlled and repeated exposure to drugrelated stimuli in order to reduce cue-reactivity. Virtual reality (VR) has proved to be a promising tool for exposition. However, identifying the variables that can modulate the efficacy of this technique is essential for selecting the most appropriate exposure modality. The aim of this study was to determine the relation between several individual variables and self-reported craving in smokers exposed to VR environments. Fortysix smokers were exposed to seven complex virtual environments that reproduce typical situations in which people smoke. Self-reported craving was selected as the criterion variable and three types of variables were selected as the predictor variables: related to nicotine dependence, related to anxiety and impulsivity, and related to the sense of presence in the virtual environments. Sense of presence was the only predictor of self-reported craving in all the experimental virtual environments. Nicotine dependence variables added predictive power to the model only in the virtual breakfast at home. No relation was found between anxiety or impulsivity and self-reported craving. Virtual reality technology can be very helpful for improving CET for substance use disorders. However, the use of virtual environments would make sense only insofar as the sense of presence was high. Otherwise, the effectiveness of exposure might be affected. © 2012 by the Massachusetts Institute of Technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a review of some published proposals for the analysis of sodium alendronate. The drug is an aminobisphosphonate compound used to inhibit the osteoclastic resorption of bone, and different methods were developed for its quantitative determination. These methodologies employed reversed-phase or ion-exchange HPLC analysis, both associated with different detectors: UV and fluorescence detection after derivatization of the drug, conductivity and refractive index detectors, as well as the indirect UV detection. Titrimetry and spectrophotometry (with previous complexation of the drug), which are simpler procedures, were also described, but they showed poor specificity when compared to liquid chromatography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La presente solicitud de patente tiene por objeto un dispositivo y método para medir magnitudes eléctricas de sensores analógicos, que 10 incorpora notables innovaciones y ventajas.La presente invención se refiere, en general, a los sistemas de medida de sensores analógicos, incluidos aquellos que generan directamente una corriente o una tensión eléctrica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El treball presentat ve motivat per la necessitat d’instal•lació d’un pàrquing públic i privat de nova construcció a nivell d’il•luminació i ventilació. Per poder satisfer les necessitats del nostre client d’estalvi energètic i confort en l’edifici es decideix d’implementar una instal•lació immòtica que és l’aplicació de tècniques de gestió i control automatitzat a un edifici terciari amb bus de comunicació KNX/EIB. Per a la il•luminació s’han utilitzat fluorescents amb balasts DALI, que permeten la seva regulació i control, per així poder adequar en tot moment l’encesa i intensitat de llum d’aquests. En quant a la ventilació s’han utilitzat variadors de freqüència per també poder optimitzar el funcionament dels ventiladors podent posar-los en marxa quan realment sigui necessari i a la potència que calgui. Per enllaçar tots els elements de la instal•lació, detectors i actuadors, sorgeig la necessitat d’implementar xarxes de comunicació com el KNX/EIB, DALI, Modbus i Ethernet. Per gestionar variables, comunicacions i controlar elements, s´hi han implementen dos autòmats programables a més d’un PC integrat per la visualització i el control del pàrquing. S’ha aconseguit de realitzar un pàrquing totalment automàtic on no és necessaria l’actuació dels operaris i amb les principals càrregues elèctriques totalment regulables en potència. S’ha comprovat que la instal•lació funciona per sota de la potència nominal de les càrregues amb l’estalvi energètic que això suposa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The RPC Detector Control System (RCS) is the main subject of this PhD work. The project, involving the Lappeenranta University of Technology, the Warsaw University and INFN of Naples, is aimed to integrate the different subsystems for the RPC detector and its trigger chain in order to develop a common framework to control and monitoring the different parts. In this project, I have been strongly involved during the last three years on the hardware and software development, construction and commissioning as main responsible and coordinator. The CMS Resistive Plate Chambers (RPC) system consists of 912 double-gap chambers at its start-up in middle of 2008. A continuous control and monitoring of the detector, the trigger and all the ancillary sub-systems (high voltages, low voltages, environmental, gas, and cooling), is required to achieve the operational stability and reliability of a so large and complex detector and trigger system. Role of the RPC Detector Control System is to monitor the detector conditions and performance, control and monitor all subsystems related to RPC and their electronics and store all the information in a dedicated database, called Condition DB. Therefore the RPC DCS system has to assure the safe and correct operation of the sub-detectors during all CMS life time (more than 10 year), detect abnormal and harmful situations and take protective and automatic actions to minimize consequential damages. The analysis of the requirements and project challenges, the architecture design and its development as well as the calibration and commissioning phases represent themain tasks of the work developed for this PhD thesis. Different technologies, middleware and solutions has been studied and adopted in the design and development of the different components and a big challenging consisted in the integration of these different parts each other and in the general CMS control system and data acquisition framework. Therefore, the RCS installation and commissioning phase as well as its performance and the first results, obtained during the last three years CMS cosmic runs, will be

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The workshop "React... explode!" is a project of science that shows the most attractive side of chemistry to pre-university students. It consists of carrying out recreational chemical experiments. Most students have more interest in the amazing and spectacular experiments which involve changes of colour, light, noise, smoke... The names of the experiments are very attractive: "The toilet’s monster", "The pharaoh’s snake", "The world of cold", "The termite reaction" ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avalanche photodiodes operated in the Geiger mode present very high intrinsic gain and fast time response, which make the sensor an ideal option for those applications in which detectors with high sensitivity and velocity are required. Moreover, they are compatible with conventional CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. Despite these excellent qualities, the photodiode suffers from high intrinsic noise, which degrades the performance of the detector and increases the memory area to store the total amount of information generated. In this work, a new front-end circuit that allows low reverse bias overvoltage sensor operation to reduce the noise in Geiger mode avalanche photodiode pixel detectors is presented. The proposed front-end circuit also enables to operate the sensor in the gated acquisition mode to further reduce the noise. Experimental characterization of the fabricated pixel with the conventional HV-AMS 0.35µm technology is also presented in this article.