860 resultados para Renewable electric energy sources


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the planning of secondary distribution circuits is approached as a mixed integer nonlinear programming problem (MINLP). In order to solve this problem, a dedicated evolutionary algorithm (EA) is proposed. This algorithm uses a codification scheme, genetic operators, and control parameters, projected and managed to consider the specific characteristics of the secondary network planning. The codification scheme maps the possible solutions that satisfy the requirements in order to obtain an effective and low-cost projected system-the conductors' adequate dimensioning, load balancing among phases, and the transformer placed at the center of the secondary system loads. An effective algorithm for three-phase power flow is used as an auxiliary methodology of the EA for the calculation of the fitness function proposed for solutions of each topology. Results for two secondary distribution circuits are presented, whereas one presents radial topology and the other a weakly meshed topology. © 2005 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper addresses the issue of apportioning of the cost of transmission losses to generators and demands in a multimarket framework. Line flows are unbundled using equivalent bilateral exchanges on a DC-network model and allocated to generators and demands. Losses are then calculated based on unbundled flows and straightforwardly apportioned to generators and demands. The proposed technique is particularly useful in a multimarket framework, where all markets have a common grid operator with complete knowledge of all network data, as is the case of the Brazilian electric-energy system. The methodology proposed is illustrated using the IEEE Reliability Test System and compared numerically with an alternative technique. Appropriate conclusions are drawn. © The Institution of Engineering and Technology 2006.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the analysis that have been carried out in the alarm system of the DCRanger EMS. The intention of this study is to present the problem of alarm processing in electric energy control centers, its various aspects and operational difficulties due to operator needs. Some tests are produced in order to identify the desirable features an alarm system should possess in order to be of effective help in the operative duty. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a method for solving the short term transmission network expansion planning problem is presented. This is a very complex mixed integer nonlinear programming problem that presents a combinatorial explosion in the search space. In order to And a solution of excellent quality for this problem, a constructive heuristic algorithm is presented in this paper. In each step of the algorithm, a sensitivity index is used to add a circuit (transmission line or transformer) or a capacitor bank (fixed or variable) to the system. This sensitivity index is obtained solving the problem considering the numbers of circuits and capacitors banks to be added (relaxed problem), as continuous variables. The relaxed problem is a large and complex nonlinear programming and was solved through a higher order interior point method. The paper shows results of several tests that were performed using three well-known electric energy systems in order to show the possibility and the advantages of using the AC model. ©2007 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to analyze the consumption, electric energy cost, and economic results of irrigated citrus (Citrus sinensis). The treatments consisted of a dripping irrigation system with one and two lateral distribution lines, a micro sprinkler irrigation system and a treatment without irrigation. For each irrigation system, three water depths were used: 100%, 75% and 50% of Etc (citrus evapotranspiration). The electric energy cost for two tariff groups, Group A and Group B, was studied. For Group A, the expenses with energy were determined for the Conventional Binomial Structure tariff, the Hour-seasonal tariff (green and blue) and the special tariff for nocturnal irrigation. The kWh cost for the tariff systems were obtained from the website of CPFL (São Paulo State Power and Light Company, Brazil). The best relation between the electric energy consumption (kWh.ha -1) and productivity (t.ha -1) occurred in the treatment irrigated with 50% of the Etc. The irrigated treatments increased productivity. The biggest productivity was observed in the irrigation treatments with 50% of the Etc when compared to the ones with 100% of the Etc. The blue and green Hour-seasonal tariff system of Group A (nocturnal irrigation) was the best option. A biggest economic turnover occurred in the treatments irrigated with 50% of the Etc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical energy from photovoltaic panels (PV) has became an increasing viable alternative because of the great concern for environmental preservation and the possibility of the reduction of the conventional fuels, and this natural energy source is free, abundant and clean. In addition, Brazil is a privileged country because of the high levels of irradiation throughout its territory all over the year. Thus the exploitation of the energy from PV is one of the best alternatives to overcome the supply electrical energy issues. However, nowadays the energy conversion efficiency is low and the initial costs are high for these energy systems. Therefore, in order to increase the efficiency of these systems the extraction of the maximum power point (MPP) from PV is extremely necessary, and it is done using the maximum power point tracking (MPPT) techniques. The MPP of the PV varies non linearly with the environmental conditions and several MPPT techniques are available in literature, and this paper presents a careful comparison among the most usual techniques, doing meaningful comparisons with respect to the amount of energy extracted, PV voltage ripple, dynamic response and use of sensors, considering that the models are implemented via MatLab/Simulink®. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aims to present proposals for improvement of key standards and resolutions concerned about the methodology for calculating the indicator of total harmonic voltage distortion, and should contribute to the process of examining the compatibility of potentially disturbing loads in electric power quality in distribution systems. These proposals were drawn from the analysis of results from measurement campaigns conducted in a case study including analysis of the connection of a new induction furnace in a foundry served by a distributor of São Paulo state. A general historical situating the quality of electric energy in the electricity sector is presented, and methodological guidelines and procedures used in experimental trials are shown. The analysis and discussion of results are prepared to answer the main questions that arise during the implementation of standards, resolutions and procedures. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Brazilian National Electricity Conservation Program - PROCEL - runs regular surveys in the electric-energy-consumption market. These studies are used as valuable data to better plan the actions of this program. These data also evaluate the program's performance by identifying the level of penetration of the most efficient electric equipment within the residential sector. PROCEL's main lines of action is to promote and make available the most efficient technologies. Based on the results from the latest survey, it is estimated that 24% of the electric-energy consumption of the residential sector is used by electric shower devices, which instantaneously heat the water that flows through them, normally using an electric resistance of 5 kW. These are an important factor in a country where electric-heating devices are present in about 73% of Brazilian households. Keeping that in mind, the purpose of this work is to present the main results of the Brazilian Solar-Water-Heating-Systems Evaluation, finished in 2010, where 535 installations were visited and more than 50 researchers from different universities participated in the project. Moreover, seven Brazilian cities were selected to be studied. The information was collected from field research and statistically treated. The collected information focused on the adequacy of the project to the household, installation, operation and life cycle of the systems, as well as the users' satisfaction level. Technical questionnaires were developed to summarize all the required information, such as a Web site designed to organize and manage the data collected and a Matlab application that performed the dimensioning and F-chart systems evaluation. Quality indicators were created through a full system monitoring, with thermographic analysis and evaluation of shading influence at the system's efficiency, using the Ecotect software.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concept of entransy was recently proposed in terms of the analogy to the electric energy stored in a capacitor. The entransy of a system describes its heat transfer ability, as the exergy of a system quantifies its work production potential. Hence, the concept of entransy can be useful in problems where the heat transfer is the main objective, as for example, in systems collecting solar energy. This concept is quite recent and there are only a few works related to this topic. It is expected, however, that this approach will soon be used more often in the analysis of problems in thermodynamics and heat transfer. The objective of this work is to present a review of the concept of entransy in a systematic way, beginning with its definition, balance equations and a few examples of simple applications. It is hoped that this concept of entransy becomes a useful tool in the analysis and design of more efficient thermal systems. © 2012 Praise Worthy Prize S.r.l.- All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the performance and carcass traits of steers fed corn or citrus pulp associated with sunflower meal or urea. Diets were composed of two energy sources (corn grain and citrus pulp) associated with two protein sources (soybean meal and urea), resulting in four treatments in forage:concentrate ratio of 40:60. It were used 24 steers, 1/2 Angus × 1/2 Nellore (18 months old and 329 kg BW) distributed in a completely randomized design which were finished in feedlot for 80 days. It were evaluated the intake, average daily gain and carcass traits of the animals. Intake of dry matter (DMI), crude protein (CPI) and neutral detergent fiber (NDFI) were affected (p<0.05) by diets. The diet with citrus pulp and urea (PU) showed the lowest (p<0.05) DMI (8.30 kg), CPI (1.03 kg) and NDFI (3.31 kg). The average daily weight gain (ADG) followed the behavior of DMI, NDFI and CPI and the lowest value (p<0.05) was observed for animals fed diet PU. Regarding carcass traits, diets containing corn associated with urea (MU) or sunflower meal (MFG) and citrus pulp associated with sunflower meal (PFG), provided the highest (p<0.05) carcass cold weights (238.37, 247.26 and 237.14 kg, respectively). However, the lowest cold carcass dressing percentage (p<0.05) was obtained in diet MU (50.57%). The association of citrus pulp with urea should not be performed when citrus pulp partially or totally replace corn as energy source in diets, because possibly this association promote an energy deficit resulting in lower performance and worse carcass traits of animals finished in feedlot.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an efficiency investigation of an isolated high step-up ratio dc-dc converter aimed to be used for energy processing from low-voltage high-current energy sources, like batteries, photovoltaic modules or fuel-cells. The considered converter consists of an interleaved active clamp flyback topology combined with a voltage multiplier at the transformer secondary side capable of two different operating modes, i.e. resonant and non-resonant according to the design of the output capacitors. The main goal of this paper is to compare these two operating modes from the component losses point of view with the aim of maximize the overall converter efficiency. The approach is based on losses prediction using steady-state theoretical models (designed in Mathcad environment), taking into account both conduction and switching losses. The models are compared with steady-state simulations and experimental results considering different operating modes to validate the approach. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nest digging spends a lot of energy existing a question about how much energy is required to dig the tunnel and initial chamber. It was hypothesized that the lipid content is used during nest digging. This hypothesis was tested by comparing the consequences of increasing digging effort in queens that were experimentally stimulated to excavate a complete founding nest either once, twice or three times consecutively, compared to control queens that didn't dig. Weight and lipid content of queens were quantified. Results showed that, in contrast with the initial expectations, weight and lipid content were not affected by the increased digging effort in the experimentally-induced successive excavations. It was conclude that the excavation by the queens did not affect the percentages of lipids and consequently the energy content, in their bodies. Probably, energy resources for the excavation wasn't originated from lipid reserves, but from other energy sources, perhaps carbohydrates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)