998 resultados para Radiology technicians


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Labour Relations Commission (Ref. CC97/566) in May 1997, recommended the establishment of an Expert Group for medical laboratory technicians/technologists as part of a set of proposals to settle their pay claims under the PCW. Download the Report here

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). METHODS: In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. RESULTS: Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. CONCLUSION: Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liam Downey Letter to HSE I refer to your letter dated 27th November 2007 requesting the Board to undertake an immediate review of the management of all events following the decision to suspend breast radiology service at the Midland Regional Hospital, Portlaoise.The HSE Board met on 27th November, 2007 to consider this request. It decided to establish a Board Committee to finalise the terms of reference for the review and to engage an external independent person to conduct it. Click here to download PDF 44kb

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Management, Governance and Communications issues arising from the Review of Breast Radiology Services at Midland Regional Hospital Portlaoise Download document here  

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On November 7th 2007 the Secretary General of the Department of Health and Children, Michael Scanlon, on behalf of his Minister, wrote to Professor Brendan Drumm, CEO requesting an urgent Report on the circumstances which led to the decisions by the HSE to:1) Suspend the breast radiology service2) Place the consultant radiologist on administrative leave and3) Initiate a clinical review of breast cancer services in the period November 2003 to August 2007 at the Midland Regional Hospital, Portlaoise. Download document here

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the extent of quality of life (QoL) associated adverse events (AEs) following PRECISION TACE with DC Bead compared with conventional transarterial chemoembolisation (cTACE). Methods and Materials: 201 intermediate HCC patients were treated with DC Bead (PRECISION TACE) or conventional TACE (cTACE) with doxorubicin in the PRECISION V clinical study. 93 patients were treated with DC Bead and 108 Patients with cTACE every 2 months and followed up for 6 months. AEs were classified according to the South West Oncology Group criteria. QoL associated AEs were defined as alopecia, constipation, nausea, vomiting, pyrexia, chills, asthenia, fatigue, and headache. Results: The biggest difference in QoL associated AEs was for alopecia: 2 patients (2.2%) for DC-Bead versus 21 patients (19.4%) for cTACE. For other clinical symptoms, constipation (n=10; 10.8% vs. n=13; 12%), vomiting (n=10; 10.8% vs. n=14; 13.0%), pyrexia (n=16; 17.2% vs. n=26; 24.1%), chills (n=1; 1.1% vs. n=5; 4.6%), and headache (n=2; 2.2% vs. n=8; 7.4%) showed lower incidence in the DC Bead group versus cTACE. Nausea, n= 15; 13.9% (n=15; 16.1%) and fatigue, n=6; 5.6% (n=13; 14.0%) were lower for cTACE. Total dose of doxorubicin was on average 35% higher in the DC Bead group. Conclusion: Although patients in the DC Bead group received a higher doxorubicin dose, less QoL associated AEs were reported for this group. Alopecia, the most obvious outward sign of toxicity, was only reported in a tenth of DC Bead patients. Thus, PRECISION TACE with DC Bead improves quality of life associated adverse events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To load embolization particles (DC-Beads, Biocompatibles, UK) with an anti-angiogenic agent (sunitinib) and to characterize the in vitro properties of the Beads-drug association.Materials: DC Beads of 100-300µm were loaded using a specially designed 10mg/ml sunitinib solution. Loading profile was studied by spectrophotometry of the supernatant solution at 430nm at different time points. Release experiment was performed using the USP method 4 (flow-through cell). Spectrophotometric determination at 430nm was used to measure drug concentration in the eluting solution.Results: We were able to load >98% of the drug in the DC-Beads in 2 hours. The maximum concentration was 20mg sunitinib/ml DC Beads. Loaded Beads gradually released 59% of the loaded drug in the eluting solution, by an ionic exchange mechanism,over 6 hours.Conclusions: DC Beads could be loaded with the multi tyrosine kinase inhibitor sunitinib using a specially designed solution. High drug payload can be achieved. The loaded DC Beads released the drug in an ionic eluting solution with an interesting release profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On savait déjà que la détresse psychique touchait souvent les professionnels des interventions d'urgence préhospitalières. Voici qu'une étude chez des ambulanciers suisses, qui, à l'instar des pompiers français, prennent en charge les patients avant leur admission à l'hôpital, montre que le surinvestissement dans le travail et la perception d'un travail faiblement valorisé sont des facteurs nettement associés à des troubles de la santé mentale. [Auteurs]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diffusion-weighted spin-echo imaging of the spine has been successfully implemented for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Nevertheless, this technique still suffers from insufficient image quality in numerous patients due to motion artifacts. The aim of this study was to investigate the impact of variable respiratory motion artifact suppression techniques on image quality in diffusion-weighted spin-echo imaging of the spine. In addition to phase-encoding reordering, a newly implemented right hemi-diaphragmaitc navigator for respiratory gating was used. Subjective and objective image quality parameters were compared. Respiratory motion artifact suppression has a major impact on image quality in diffusion-weighted imaging of the spine. Phase-encoding reordering does not enhance image quality while right hemi-diaphragmatic respiratory navigator gating significantly improves image quality at the cost of data acquisition time. Navigator gating should be used if standard spin-echo diffusion-weighted imaging demonstrates insufficient image quality.