989 resultados para Quantitative imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barnardos supports children whose well-being is under threat, by working with them, their families and communities and by campaigning for the rights of children. Barnardos was established in Ireland in 1962 and is Ireland’s leading independent Children's charity.  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and time efficient technique to illustrate specimens is described and demonstrated with Paleogene radiolarians. This method produces Scanning Electron Microscope (SEM) and composite focal depth Transmitted Light Microscope (TLM) images for single radiolarian specimens. We propose the use of this technique to clarify radiolarian taxonomy. This technique has distinct advantages over previously published time consuming techniques that can also require toxic materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In the middle of the 90's, the discovery of endogenous ligands for cannabinoid receptors opened a new era in this research field. Amides and esters of arachidonic acid have been identified as these endogenous ligands. Arachidonoylethanolamide (anandamide or AEA) and 2-Arachidonoylglycerol (2-AG) seem to be the most important of these lipid messengers. In addition, virodhamine (VA), noladin ether (2-AGE), and N-arachidonoyl dopamine (NADA) have been shown to bind to CB receptors with varying affinities. During recent years, it has become more evident that the EC system is part of fundamental regulatory mechanisms in many physiological processes such as stress and anxiety responses, depression, anorexia and bulimia, schizophrenia disorders, neuroprotection, Parkinson disease, anti-proliferative effects on cancer cells, drug addiction, and atherosclerosis. Aims: This work presents the problematic of EC analysis and the input of Information Dependant Acquisition based on hybrid triple quadrupole linear ion trap (QqQLIT) system for the profiling of these lipid mediators. Methods: The method was developed on a LC Ultimate 3000 series (Dionex, Sunnyvale, CA, USA) coupled to a QTrap 4000 system (Applied biosystems, Concord, ON, Canada). The ECs were separated on an XTerra C18 MS column (50 × 3.0 mm i.d., 3.5 μm) with a 5 min gradient elution. For confirmatory analysis, an information-dependant acquisition experiment was performed with selected reaction monitoring (SRM) as survey scan and enhanced produced ion (EPI) as dependant scan. Results: The assay was found to be linear in the concentration range of 0.1-5 ng/mL for AEA, 0.3-5 ng/mL for VA, 2-AGE, and NADA and 1-20 ng/mL for 2-AG using 0.5 mL of plasma. Repeatability and intermediate precision were found less than 15% over the tested concentration ranges. Under non-pathophysiological conditions, only AEA and 2-AG were actually detected in plasma with concentration ranges going from 104 to 537 pg/mL and from 2160 to 3990 pg/mL respectively. We have particularly focused our scopes on the evaluation of EC level changes in biological matrices through drug addiction and atherosclerosis processes. We will present preliminary data obtained during pilot study after administration of cannabis on human patients. Conclusion: ECs have been shown to play a key role in regulation of many pathophysiological processes. Medical research in these different fields continues to growth in order to understand and to highlight the predominant role of EC in the CNS and peripheral tissues signalisation. The profiling of these lipids needs to develop rapid, highly sensitive and selective analytical methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determining groundwater flow paths of infiltrated river water is necessary for studying biochemical processes in the riparian zone, but their characterization is complicated by strong temporal and spatial heterogeneity. We investigated to what extent repeat 3D surface electrical resistance tomography (ERT) can be used to monitor transport of a salt-tracer plume under close to natural gradient conditions. The aim is to estimate groundwater flow velocities and pathways at a site located within a riparian groundwater system adjacent to the perialpine Thur River in northeastern Switzerland. Our ERT time-lapse images provide constraints on the plume's shape, flow direction, and velocity. These images allow the movement of the plume to be followed for 35 m. Although the hydraulic gradient is only 1.43 parts per thousand, the ERT time-lapse images demonstrate that the plume's center of mass and its front propagate with velocities of 2x10(-4) m/s and 5x10(-4) m/s, respectively. These velocities are compatible with groundwater resistivity monitoring data in two observation wells 5 m from the injection well. Five additional sensors in the 5-30 m distance range did not detect the plume. Comparison of the ERT time-lapse images with a groundwater transport model and time-lapse inversions of synthetic ERT data indicate that the movement of the plume can be described for the first 6 h after injection by a uniform transport model. Subsurface heterogeneity causes a change of the plume's direction and velocity at later times. Our results demonstrate the effectiveness of using time-lapse 3D surface ERT to monitor flow pathways in a challenging perialpine environment over larger scales than is practically possible with crosshole 3D ERT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary goal of this study was to design a fluorescent E-selectin-targeted iodine-containing liposome for specific E-selectin imaging with the use of micro-CT. The secondary goal was to correlate the results of micro-CT imaging with other imaging techniques with cellular resolution, i.e., confocal and intravital microscopy. E-selectin-targeted liposomes were tested on endothelial cells in culture and in vivo in HT-29 tumor-bearing mice (n = 12). The liposomes contained iodine (as micro-CT contrast medium) and fluorophore (as optical contrast medium) for confocal and intravital microscopy. Optical imaging methods were used to confirm at the cellular level, the observations made with micro-CT. An ischemia-reperfusion model was used to trigger neovessel formation for intravital imaging. The E-selectin-targeted liposomes were avidly taken up by activated endothelial cells, whereas nontargeted liposomes were not. Direct binding of the E-selectin-targeted liposomes was proved by intravital microscopy, where bright spots clearly appeared on the activated vessels. Micro-CT imaging also demonstrated accumulation of the targeted lipsomes into subcutaneous tumor by an increase of 32 +/- 8 HU. Hence, internalization by activated endothelial cells was rapid and mediated by E-selectin. We conclude that micro-CT associated with specific molecular contrast agent is able to detect specific molecular markers on activated vessel walls in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The yield as well as phenotypic and functional parameters of canine peripheral blood monocyte-derived macrophages were analyzed. The cells that remained adherent to Teflon after 10 days of culture had high phagocytic activity when inoculated with Leishmania chagasi. Flow cytometric analysis demonstrated that more than 80% of cultured cells were positive for the monocyte/macrophage marker CD14.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a global approach combining fluorescence recovery after photobleaching (FRAP), fluorescence correlation spectroscopy (FCS), and fluorescence resonance energy transfer (FRET), we address the behavior in living cells of the peroxisome proliferator-activated receptors (PPARs), a family of nuclear receptors involved in lipid and glucose metabolism, inflammation control, and wound healing. We first demonstrate that unlike several other nuclear receptors, PPARs do not form speckles upon ligand activation. The subnuclear structures that may be observed under some experimental conditions result from overexpression of the protein and our immunolabeling experiments suggest that these structures are subjected to degradation by the proteasome. Interestingly and in contrast to a general assumption, PPARs readily heterodimerize with retinoid X receptor (RXR) in the absence of ligand in living cells. PPAR diffusion coefficients indicate that all the receptors are engaged in complexes of very high molecular masses and/or interact with relatively immobile nuclear components. PPARs are not immobilized by ligand binding. However, they exhibit a ligand-induced reduction of mobility, probably due to enhanced interactions with cofactors and/or chromatin. Our study draws attention to the limitations and pitfalls of fluorescent chimera imaging and demonstrates the usefulness of the combination of FCS, FRAP, and FRET to assess the behavior of nuclear receptors and their mode of action in living cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromagnetic fields arising from magnetic resonance imaging (MRI) can cause various clinically relevant functional disturbances in patients with cardiac pacemakers. Consequently, an implanted pacemaker is generally considered a contraindication for an MRI scan. With approximately 60 million MRI scans performed worldwide per year, MRI may be indicated for an estimated majority of pacemaker patients during the lifetime of their pacemakers. The availability of MR conditional pacemakers with CE labelling is of particular advantage since they allow the safe use of pacemakers in MRI. In this article the current state of knowledge on pacemakers and MR imaging is discussed. We present the results of a survey conducted among Swiss radiologists to assess current practice in patients with pacemakers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rupture of a congenital aneurysm of the sinus of Valsalva is a rare congenital cardiac malformation. This case report describes a congenital aneurysm of the sinus of Valsalva which ruptured into the right ventricle in a 3-year-old girl. The exact route of the fistula through the cardiac walls and the localization of the rupture into the right ventricle was not completely defined by two-dimensional and color Doppler echocardiography and could be determined only by magnetic resonance imaging (MRI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcinosis is a typical feature of systemic sclerosis (SSc) and can be found in many different tissues including the superficial soft tissues, periarticular structures, muscles, and tendons. It can also provoke erosive changes on bones. Investigation is conducted most often with plain radiographs. However, when a more detailed assessment is necessary, multidetector computed tomography (MDCT) is helpful owing to its multiplanar reformat (MPR) ability. The purpose of this review is to provide an overview of the various appearances of calcinosis in SSc patients as visualized at MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In primary prevention of cardiovascular disease (CVD), it is accepted that the intensity of risk factor treatment should be guided by the magnitude of absolute risk. Risk factors tools like Framingham risk score (FHS) or noninvasive atherosclerosis imaging tests are available to detect high risk subjects. However, these methods are imperfect and may misclassify a large number of individuals. The purpose of this prospective study was to evaluate whether the prediction of future cardiovascular events (CVE) can be improved when subclinical imaging atherosclerosis (SCATS) is combined with the FRS in asymptomatic subjects. Methods: Overall, 1038 asymptomatic subjects (413 women, 625 men, mean age 49.1±12.8 years) were assessed for their cardiovascular risk using the FRS. B-mode ultrasonography on carotid and femoral arteries was performed by two investigators to detect atherosclerotic plaques (focal thickening of intima-media > 1.2 mm) and to measure carotid intima-media thickness (C-IMT). The severity of SCATS was expressed by an ATS-burden Score (ABS) reflecting the number of the arterial sites with >1 plaques (range 0-4). CVE were defined as fatal or non fatal acute coronary syndrome, stroke, or angioplasty for peripheral artery disease. Results: during a mean follow-up of 4.9±3.1 years, 61 CVE were recorded. Event rates the rate of CVE increased significantly from 2.7% to 39.1% according to the ABS (p<0.001) and from 4% to 24.6% according to the quartiles of C-IMT. Similarly, FRS predicted CVE (p<0.001). When computing the angiographic markers of SCATS in addition of FRS, we observed an improvement of net reclassification rate of 16.6% (p< 0.04) for ABS as compared to 5.5% (p = 0.26) for C-IMT. Conclusion: these results indicate that the detection of subjects requiring more attention to prevent CVE can be significantly improved when using both FRS and SCATS imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purposes of this study were to (1) develop a high-resolution 3-T magnetic resonance angiography (MRA) technique with an in-plane resolution approximate to that of multidetector coronary computed tomography (MDCT) and a voxel size of 0.35 × 0.35 × 1.5 mm³ and to (2) investigate the image quality of this technique in healthy participants and preliminarily in patients with known coronary artery disease (CAD). MATERIALS AND METHODS: A 3-T coronary MRA technique optimized for an image acquisition voxel as small as 0.35 × 0.35 × 1.5 mm³ (high-resolution coronary MRA [HRC]) was implemented and the coronary arteries of 22 participants were imaged. These included 11 healthy participants (average age, 28.5 years; 5 men) and 11 participants with CAD (average age, 52.9 years; 5 women) as identified on MDCT. In addition, the 11 healthy participants were imaged using a method with a more common spatial resolution of 0.7 × 1 × 3 mm³ (regular-resolution coronary MRA [RRC]). Qualitative and quantitative comparisons were made between the 2 MRA techniques. RESULTS: Normal vessels and CAD lesions were successfully depicted at 350 × 350 μm² in-plane resolution with adequate signal-to-noise ratio (SNR) and contrast-to-noise ratio. The CAD findings were consistent among MDCT and HRC. The HRC showed a 47% improvement in sharpness despite a reduction in SNR (by 72%) and in contrast-to-noise ratio (by 86%) compared with the regular-resolution coronary MRA. CONCLUSION: This study, as a first step toward substantial improvement in the resolution of coronary MRA, demonstrates the feasibility of obtaining at 3 T a spatial resolution that approximates that of MDCT. The acquisition in-plane pixel dimensions are as small as 350 × 350 μm² with a 1.5-mm slice thickness. Although SNR is lower, the images have improved sharpness, resulting in image quality that allows qualitative identification of disease sites on MRA consistent with MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boundaries for delta, representing a "quantitatively significant" or "substantively impressive" distinction, have not been established, analogous to the boundary of alpha, usually set at 0.05, for the stochastic or probabilistic component of "statistical significance". To determine what boundaries are being used for the "quantitative" decisions, we reviewed pertinent articles in three general medical journals. For each contrast of two means, contrast of two rates, or correlation coefficient, we noted the investigators' decisions about stochastic significance, stated in P values or confidence intervals, and about quantitative significance, indicated by interpretive comments. The boundaries between impressive and unimpressive distinctions were best formed by a ratio of greater than or equal to 1.2 for the smaller to the larger mean in 546 comparisons, by a standardized increment of greater than or equal to 0.28 and odds ratio of greater than or equal to 2.2 in 392 comparisons of two rates; and by an r value of greater than or equal to 0.32 in 154 correlation coefficients. Additional boundaries were also identified for "substantially" and "highly" significant quantitative distinctions. Although the proposed boundaries should be kept flexible, indexes and boundaries for decisions about "quantitative significance" are particularly useful when a value of delta must be chosen for calculating sample size before the research is done, and when the "statistical significance" of completed research is appraised for its quantitative as well as stochastic components.