885 resultados para Pregnant women


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives To estimate, by neonatal screening, the birth prevalence of congenital toxoplasmosis among live-born infants in Sergipe state, Brazil, and to investigate the clinical features of affected infants. Methods Dried blood spot specimens obtained from 15 204 neonates were assayed for the presence of anti-T. gondii IgM antibodies. Duplicate retesting was done in infants with positive and borderline results. Confirmatory testing in peripheral blood samples consisted of testing for anti-T. gondii IgG and IgM in infants and mothers. Those with possible congenital toxoplasmosis were evaluated and followed up to a median age of 20 months. Congenital infection was confirmed in the presence of persisting anti-T. gondii IgG antibodies beyond 12 months of age. All infants with confirmed infection were treated with pyrimethamine, sulfadiazine and folinic acid for 1 year. Results Fifty-three infants had detectable IgM in dried blood spot specimens. Confirmatory testing was reactive in 39/50, of which, 38 completed follow-up. Six of 15 204 newborns were diagnosed with congenital toxoplasmosis, resulting in an estimated birth prevalence of four per 10 000 [CI 95% 1.48.0]. Four infants (67%) showed signs of congenital toxoplasmosis in their first year of life; three (75%) had retinochoroidal scars, and one had cerebral calcifications. Two infants remained asymptomatic until 20 months of age. Conclusions The birth prevalence of congenital toxoplasmosis is high in the Brazilian state of Sergipe, with most of the infants showing ocular lesions. Preventive measures are strongly warranted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We evaluated the diagnostic quality of first-trimester ultrasound images transmitted in realtime using low-cost telecommunications. A prospective sample of fetal ultrasound images from 11 weeks to 13 weeks and six days of pregnancy was obtained from pregnant women over 18 years old. The examinations were transmitted in realtime to three independent examiners who carried out a qualitative assessment based on parameters established by the Fetal Medicine Foundation. All fetal structures could be viewed and the quality of images received by the examiners was considered normal. There were significant differences for crown-rump length and nuchal translucency in the transmitted images but the loss in definition was acceptable. Thus the quality of images transmitted via the Internet through the use of low-cost software appeared suitable for screening for chromosomal abnormalities in the first trimester of pregnancy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the FHR parameters in term pregnancies complicated by asthma. Study design: prospective cross-sectional study performed between July 2008 and November 2009. Twenty-one singleton pregnancy between 36 and 40 weeks gestation with diagnosis of maternal asthma and no current use of oral corticosteroids were compared with 30 pregnancies without morbidities at the same gestational age. The computerized cardiotocography (System 8002, Sonicaid) was performed and 30 min analysis was studied. Statistical analysis included Student's t-test or Mann-Whitney U test for comparisons between groups. Categorical data were compared using the chi(2)-test or Fisher's exact test. Results: There were no significant differences in FHR parameters analyzed by computerized cardiotocography: basal FHR (p = 0.80), number of accelerations >10 bpm (p = 0.08) or >15 bpm (p = 0.20), duration of high episodes (p = 0.70), duration of low episodes (p = 0.46) and STV (p = 0.66). Asthmatic mothers presented mean number of fetal movement per hour significantly lower than control group (34.6 +/- 28.2 vs. 60.6 +/- 43.1, p = 0.02). Conclusion: Computerized cardiotocography demonstrates no association between the abnormal parameters of FHR and maternal asthma in term pregnancies. Maternal asthma was associated with less fetal movements per hour, suggesting further studies on the counting of fetal movements in pregnant women with asthma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Southern Brazil is considered an area of low Hepatitis B endemicity, but some areas of higher endemicity have been described in the Southwest of Parana and Santa Catarina states. The aim of this study was to evaluate viral genotypes circulating throughout Parana state. PCR amplification and partial sequencing of the S gene was carried out in 228 samples from HBsAg positive candidate blood donors. Samples have been collected in seven different counties (Cascavel, Curitiba, Foz do Iguacu, Francisco Beltrao, Matinga Londrina and Paranagua). The most common HBV genotype in Parana state was D (82.9%; 189/228), followed by A (14.1%; 32/228). Genotypes F (1.3%; 3/228), C (1.3%; 3/228) and H (0.4%; 1/228) were also found. Distribution of genotypes was different in the studied counties, but genotype D was the most frequent in all of them. In Francisco Beltrao, all studied samples belonged to genotype D. The high prevalence of HBV genotype Din South of Brazil is explained by the intense migration of settlers from Europeans countries. Subgenotypes A1 and A2 were identified circulating in all cities where HBV/A was found. As observed in other areas of Brazil, HBV/A1 is more frequent than the HBV/A2 in Parana state and its presence was significantly larger in black and mulatto individuals. Genotype C was found only in individuals with Asian ancestry from Londrina and Maringa. Most HBV/F sequences identified in this study were classified as subgenotype F2a that was previously described in Brazil. The sole case of subgenotype F4 was from Foz do Iguacu city, near to Northern Argentina, where F4 is highly prevalent. The single genotype H sample was from Curitiba. This is the first case of this genotype described in Brazil. Further studies should be carried out to determine if more genotype H samples can be found in other populations from Brazil. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Although iron deficiency is considered to be the main cause of anemia in children worldwide, other contributors to childhood anemia remain little studied in developing countries. We estimated the relative contributions of different factors to anemia in a population-based, cross-sectional survey. Methodology: We obtained venous blood samples from 1111 children aged 6 months to 10 years living in the frontier town of Acrelandia, northwest Brazil, to estimate the prevalence of anemia and iron deficiency by measuring hemoglobin, erythrocyte indices, ferritin, soluble transferrin receptor, and C-reactive protein concentrations. Children were simultaneously screened for vitamin A, vitamin B-12, and folate deficiencies; intestinal parasite infections; glucose-6-phosphate dehydrogenase deficiency; and sickle cell trait carriage. Multiple Poisson regression and adjusted prevalence ratios (aPR) were used to describe associations between anemia and the independent variables. Principal Findings: The prevalence of anemia, iron deficiency, and iron-deficiency anemia were 13.6%, 45.4%, and 10.3%, respectively. Children whose families were in the highest income quartile, compared with the lowest, had a lower risk of anemia (aPR, 0.60; 95% CI, 0.37-0.98). Child age (<24 months, 2.90; 2.01-4.20) and maternal parity (>2 pregnancies, 2.01; 1.40-2.87) were positively associated with anemia. Other associated correlates were iron deficiency (2.1; 1.4-3.0), vitamin B-12 (1.4; 1.0-2.2), and folate (2.0; 1.3-3.1) deficiencies, and C-reactive protein concentrations (>5 mg/L, 1.5; 1.1-2.2). Conclusions: Addressing morbidities and multiple nutritional deficiencies in children and mothers and improving the purchasing power of poorer families are potentially important interventions to reduce the burden of anemia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.