993 resultados para Power Doppler ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparison between three switching techniques that can be used in three-phase four-wire Shunt Active Power Filters (SAPFs). The implemented switching techniques are: Periodic-Sampling (PS), Triangular Carrier Pulse-Width Modulation (TC-PWM) and Space Vector PWM (SVPWM). The comparison between them is made in terms of the compensated currents THD%, implementation complexity, necessary CPU time and SAPF efficiency. To perform this comparison are presented and analyzed several experimental results, obtained with a 20 kVA Shunt Active Power Filter prototype, specially developed for this purpose. The control system of the developed SAPF is based in the p-q Theory with a grid synchronization algorithm p-PLL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Methods: Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of −6.00, −3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. Results: In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p < 0.05 in all cases), did not change with the +3.00 soft lens power (p = 1.0); and steepened with the +6.00 soft lens power (p = 0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p > 0.05). RGP’s BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p < 0.001), but no significant differences were found among negative- or positive-powers separately (both p > 0.05). Estimated RGP’s final power increased significantly with positive in comparison with negative lens powers (all p < 0.001), but no significant differences were found among negative or positive lens powers separately (both p > 0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p > 0.05). Conclusion: The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many funding agencies have Open Access mandates in place, but how often are scientific publications as outputs linked to funding details? The benefits of linking funding information to publications as part of the deposit workflow can assist in adhering to Open Access mandates. This paper examines how OpenAIRE – Open Access Infrastructure for Research in Europe – can ease monitoring Open Access and reporting processes for funders, and presents some results and opportunities. It also outlines how it relies on cleaned and curated repository content, a vital cog in the ever turning wheel of the global scholarly landscape, and the benefits it brings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this work was to study the central and peripheral thickness of several contact lenses (CL) with different powers and analyze how thickness variation affects CL oxygen transmissibility. METHODS: Four daily disposable and five monthly or biweekly CL were studied. The powers of each CL were: the maximum negative power of each brand; -6.00 D; -3.00 D; zero power (-0.25 D or -0.50 D), +3.00 D and +6.00 D. Central and peripheral thicknesses were measured with an electronic thickness gauge. Each lens was measured five times (central and 3mm paracentral) and the mean value was considered. Using the values of oxygen permeability given by the manufacturers and the measured thicknesses, the variation of oxygen transmissibility with lens power was determined. RESULTS: For monthly or biweekly lenses, central thickness changed between 0.061 ± 0.002 mm and 0.243 ± 0.002 mm, and peripheral thickness varied between 0.084 ± 0.002 mm and 0.231 ± 0.015 mm. Daily disposable lenses showed central values ranging between 0.056 ± 0.0016 mm and 0.205 ± 0.002 mm and peripheral values between 0.108 ± 0.05 and 0.232 ± 0.011 mm. Oxygen transmissibility (in units) of monthly or biweekly CL ranged between 39.4 ± 0.3 and 246.0 ± 14.4 and for daily disposable lenses the values range between 9.5 ± 0.5 and 178.1 ± 5.1. CONCLUSIONS: The central and peripheral thicknesses change significantly when considering the CL power and this has a significant impact on the oxygen transmissibility. Eyecare practitioners must have this fact in account when high power plus or minus lenses are fitted or when continuous wear is considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctoral Programme in Telecommunication - MAP-tele

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work explores the best conditions for the enzymatic synthesis of poly (ethylene glutarate) for the first time. The start-up materials are the liquids; diethyl glutarate and ethylene glycol diacetate, without the need of addition of extra solvent. The reactions are catalyzed by lipase B from Candida antarctica immobilized on glycidyl methacrylate-ter-divinylbenzene-ter-ethylene glycol dimethacrylate at 40 °C during 18 h in water bath with mechanical stirring or 1 h in ultrasonic bath followed by 6 h in vacuum in both the cases for evaporation of ethyl acetate. The application of ultrasound significantly intensified the polyesterification reaction with reduction of the processing time from 24 to 7 h. The same degree of polymerization was obtained for the same enzyme loading in less time of reaction when using the ultrasound treatment. The degree of polymerization for long-term polyesterification was improved approximately 8-fold due to the presence of sonication during the reaction. The highest degree of polymerization achieved was 31, with a monomer conversion of 96.77%. The ultrasound treatment demonstrated to be an effective green approach to intensify the polyesterification reaction with enhanced initial kinetics and high degree of polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a estrutura e função do ventrículo esquerdo (VE) e a rigidez arterial em portadores de diabetes mellitus tipo II. MÉTODOS: Foram estudados 13 doentes diabéticos de ambos os sexos (55±8 anos) sem outras doenças. A estrutura e função do VE foram avaliadas por meio de ecodopplercardiografia associada à monitorização não invasiva da pressão arterial (PA). Os resultados foram comparados aos obtidos em grupo de indivíduos normais de mesma idade (n=12). RESULTADOS: Não houve diferenças entre os grupos quanto a PA diastólica, dimensões das câmaras esquerdas e índices de função sistólica e diastólica. Os pacientes diabéticos apresentaram índice de massa do VE (101±10 vs 80±14g/m²; p<0,001) e índice de rigidez arterial sistêmica (0,86±0,26 vs 0,69±0,19mmHg/mL; p<0,05) significantemente maiores que os controles. CONCLUSÃO: O diabetes mellitus está associado a aumento da rigidez arterial sistêmica e esse fator poderia contribuir para seus efeitos adversos sobre o VE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar pelo Doppler-ecocardiograma alterações cardíacas, estrutural e/ou funcionais, que podem surgir nos jovens normotensos com história familiar de hipertensão arterial sistêmica (HAS). MÉTODOS: Estudo prospectivo realizado com 62 jovens normotensos entre 15 e 30 anos, sendo 32 filhos de hipertensos (grupo 1) e 30 filhos de normotensos (grupo 2) comparáveis quanto à pressão arterial, superfície corporal, freqüência cardíaca, idade e sexo. Após exame clínico, todos realizaram Doppler-ecocardiograma para avaliar as estruturas cardíacas e a função ventricular esquerda (sistólico e diastólica). RESULTADOS: A fração de encurtamento sistólico do ventrículo esquerdo (VE) foi significativamente maior no grupo 1 - valor médio de 38,03±4,95% - do que no grupo 2 - 34,7±4,48 % (p<0,01). O tempo de desaceleração mitral (TD) variou de 85 a 160ms - médio de 116,47±16,99ms - no grupo 1 e de 100 a 220ms - médio de 126,73±26,66ms - no grupo 2 (p<0,05). Houve correlação entre o índice de massa do VE e o diâmetro do átrio esquerdo (AE) no grupo 1 (r= 0,514, p<0,01). CONCLUSÃO: Os filhos de hipertensos, quando comparados com filhos de normotensos, exibem exacerbação da função sistólica do VE, semelhante ao que ocorre na fase inicial da HAS ou na HAS "borderline", mesmo que não haja hipertrofia do VE ou aumento dos níveis pressóricos. O TD mitral (mais curto no grupo 1) foi o único parâmetro de função diastólica do VE que diferiu nos 2 grupos analisados. A correlação entre o índice de massa do VE e o diâmetro do AE nos filhos de hipertensos sugere que o AE se modifica de acordo com as alterações funcionais e hemodinâmicas do VE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Public participation in environmental governance is typically associated with citizen access to power despite many closures and limitations having been identified in participatory processes. This article proposes an analytical framework to analyse discursive practices involved in public consultation processes. Critical Discourse Analysis is used to examine and appraise citizens’ access, standing and influence. We apply that framework to a ‘notice and comment’ process on a hydroelectric power plan in Portugal and show that it was discursively managed to justify the decision of constructing 10 large dams and to reject critical or alternative views. Citizens’ access, standing and influence were constrained through diverse discursive practices which (re)produced very unequal power relationsbetween policy proponents and participating individuals. More generally, the article illustrates the potential of Critical Discourse Analysis to assess voice(s) in policy processes. Focusing on argumentative, interactional and rhetorical levels, and how they are interwoven in public consultation discourses, the proposed framework is conceivably applicable in other studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA). METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV) mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume) and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS). The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi) were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.