927 resultados para Portal vein thrombosis
Resumo:
BACKGROUND We aimed to describe the effects of ticagrelor versus clopidogrel on stent thrombosis in the Platelet Inhibition and Patient Outcomes (PLATO) trial. METHODS AND RESULTS Of 18 624 patients hospitalized for acute coronary syndromes, 11 289 (61%) had at least 1 intracoronary stent. Ticagrelor reduced stent thrombosis compared with clopidogrel across all definitions: definite, 1.37% (n=71) versus 1.93% (n=105; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.50-0.90; P=0.0091); definite or probable, 2.21% (n=118) versus 2.87% (n=157; HR, 0.75; 95% CI, 0.59-0.95; P=0.017); and definite, probable, and possible, 2.94% (n=154) versus 3.77 (n=201; HR, 0.77; 95% CI, 0.62-0.95). The reduction in definite stent thrombosis was consistent regardless of acute coronary syndrome type, presence of diabetes mellitus, stent type (drug-eluting or bare metal stent), CYP2C19 genetic status, loading dose of aspirin, dose of clopidogrel before randomization, and use of glycoprotein IIb/IIIa inhibitors at randomization. The reduction in stent thrombosis with ticagrelor was numerically greater for late (>30 days; HR, 0.48; 95% CI, 0.24-0.96) and subacute (4 hours-30 days; HR, 0.60; 95% CI, 0.39-0.93) compared with acute (<24 hours; HR, 0.94; 95% CI, 0.43-2.05) stent thrombosis or for patients compliant to therapy (ie, taking blinded study treatment ≥80% of the time) compared with less compliant patients. Randomization to ticagrelor was a strong independent inverse predictor of definite stent thrombosis (HR, 0.65; 95% CI, 0.48-0.88). CONCLUSION Ticagrelor compared with clopidogrel reduces the incidence of stent thrombosis in patients with acute coronary syndromes, with consistent benefit across a broad range of patient, stent, and treatment characteristics.
Resumo:
BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.
Resumo:
Genetic and biochemical studies have suggested the existence of a bacteriophage-like, DNA-packaging/ejecting portal complex in herpesviruses capsids, but its arrangement remained unknown. Here, we report the first visualization of a unique vertex in the Kaposi's sarcoma-associated herpesvirus (KSHV) capsid by cryoelectron tomography, thus providing direct structural evidence for the existence of a portal complex in a gammaherpesvirus. This putative KSHV portal is an internally localized, umbilicated structure and lacks all of the external machineries characteristic of portals in DNA bacteriophages.
Resumo:
The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^
Resumo:
BACKGROUND Although well-established for suspected lower limb deep venous thrombosis, an algorithm combining a clinical decision score, d-dimer testing, and ultrasonography has not been evaluated for suspected upper extremity deep venous thrombosis (UEDVT). OBJECTIVE To assess the safety and feasibility of a new diagnostic algorithm in patients with clinically suspected UEDVT. DESIGN Diagnostic management study. (ClinicalTrials.gov: NCT01324037) SETTING: 16 hospitals in Europe and the United States. PATIENTS 406 inpatients and outpatients with suspected UEDVT. MEASUREMENTS The algorithm consisted of the sequential application of a clinical decision score, d-dimer testing, and ultrasonography. Patients were first categorized as likely or unlikely to have UEDVT; in those with an unlikely score and normal d-dimer levels, UEDVT was excluded. All other patients had (repeated) compression ultrasonography. The primary outcome was the 3-month incidence of symptomatic UEDVT and pulmonary embolism in patients with a normal diagnostic work-up. RESULTS The algorithm was feasible and completed in 390 of the 406 patients (96%). In 87 patients (21%), an unlikely score combined with normal d-dimer levels excluded UEDVT. Superficial venous thrombosis and UEDVT were diagnosed in 54 (13%) and 103 (25%) patients, respectively. All 249 patients with a normal diagnostic work-up, including those with protocol violations (n = 16), were followed for 3 months. One patient developed UEDVT during follow-up, for an overall failure rate of 0.4% (95% CI, 0.0% to 2.2%). LIMITATIONS This study was not powered to show the safety of the substrategies. d-Dimer testing was done locally. CONCLUSION The combination of a clinical decision score, d-dimer testing, and ultrasonography can safely and effectively exclude UEDVT. If confirmed by other studies, this algorithm has potential as a standard approach to suspected UEDVT. PRIMARY FUNDING SOURCE None.
Resumo:
BACKGROUND AND AIMS Liver stiffness is increasingly used in the non-invasive evaluation of chronic liver diseases. Liver stiffness correlates with hepatic venous pressure gradient (HVPG) in patients with cirrhosis and holds prognostic value in this population. Hence, accuracy in its measurement is needed. Several factors independent of fibrosis influence liver stiffness, but there is insufficient information on whether meal ingestion modifies liver stiffness in cirrhosis. We investigated the changes in liver stiffness occurring after the ingestion of a liquid standard test meal in this population. METHODS In 19 patients with cirrhosis and esophageal varices (9 alcoholic, 9 HCV-related, 1 NASH; Child score 6.9±1.8), liver stiffness (transient elastography), portal blood flow (PBF) and hepatic artery blood flow (HABF) (Doppler-Ultrasound) were measured before and 30 minutes after receiving a standard mixed liquid meal. In 10 the HVPG changes were also measured. RESULTS Post-prandial hyperemia was accompanied by a marked increase in liver stiffness (+27±33%; p<0.0001). Changes in liver stiffness did not correlate with PBF changes, but directly correlated with HABF changes (r = 0.658; p = 0.002). After the meal, those patients showing a decrease in HABF (n = 13) had a less marked increase of liver stiffness as compared to patients in whom HABF increased (n = 6; +12±21% vs. +62±29%,p<0.0001). As expected, post-prandial hyperemia was associated with an increase in HVPG (n = 10; +26±13%, p = 0.003), but changes in liver stiffness did not correlate with HVPG changes. CONCLUSIONS Liver stiffness increases markedly after a liquid test meal in patients with cirrhosis, suggesting that its measurement should be performed in standardized fasting conditions. The hepatic artery buffer response appears an important factor modulating postprandial changes of liver stiffness. The post-prandial increase in HVPG cannot be predicted by changes in liver stiffness.
Resumo:
This manuscript deals with the adaptation of quartz-microfabrics to changing physical deformation conditions, and discusses their preservation potential during subsequent retrograde deformation. Using microstructural analysis, a sequence of recrystallization processes in quartz, ranging from Grain-Boundary Migration Recrystallization (GBM) over Subgrain-Rotation Recrystallization (SGR) to Bulging Nucleation (BLG) is detected for the Simplon fault zone (SFZ) from the low strain rim towards the internal high strain part of the large-scale shear zone. Based on: (i) the retrograde cooling path; (ii) estimates of deformation temperatures; and (iii) spatial variation of dynamic recrystallization processes and different microstructural characteristics, continuous strain localization with decreasing temperature is inferred. In contrast to the recrystallization microstructures, crystallographic preferred orientations (CPO) have a longer memory. CPO patterns indicative of prism and rhomb glide systems in mylonitic quartz veins, overprinted at low temperatures (�400 �C), suggest inheritance of a high-temperature deformation. In this way, microstructural, textural and geochemical analyses provide information for several million years of the deformation history. The reasons for such incomplete resetting of the rock texture is that strain localization is caused by change in effective viscosity contrasts related to temporal large- and small-scale temperature changes during the evolution of such a long-lived shear zone. The spatially resolved, quantitative investigation of quartz microfabrics and associated recrystallization processes therefore provide great potential for an improved understanding of the geodynamics of large-scale shear zones.
Resumo:
OBJECTIVE Everolimus drug-eluting stents (EES) are superior to early-generation drug-eluting stents (DES), releasing sirolimus (SES) or paclitaxel (PES) in preventing stent thrombosis (ST). Since an impaired LVEF seems to increase the risk of ST, we aimed to investigate the difference in outcome of patients with varying LVEF using EES versus early-generation DES. METHODS In a prospective cohort study, we compared the risk of ST in patients in three LVEF subgroups: normal (LVEF >50%), mildly impaired (LVEF >40% and ≤50%) and moderate-severely impaired (LVEF ≤40%). Within these various LVEF groups, we compared EES with SES and PES after adjustment for baseline differences. RESULTS We assessed a cohort of 5363 patients, with follow-up of up to 4 years and available LVEF. Overall definite ST occurred in 123 (2.3%) patients. ST rates were higher in the LVEF moderate-severely impaired group compared with the normal LVEF group (2.8% vs 2.1%; HR 1.82; CI 1.10 to 3.00). Especially early ST (EST) was more frequent in the moderate-severely impaired LVEF group (HR 2.20; CI 1.06 to 4.53). Overall rates of definite ST were lower in patients using EES compared with patients using SES or PES in all LVEF groups. Interaction terms were not statistically significant. ST rates were higher in the moderate-severely impaired LVEF group compared with the normal LVEF group when using SES or PES, but not significantly different when using EES. CONCLUSIONS EES was associated with a lower risk of definite ST compared with early-generation DES. This lower risk was independent of LVEF, even though ST rates were higher in patients with a moderate-severely impaired LVEF. TRIAL REGISTRATION NO MEC-2013-262.
Resumo:
Aims: The reported rate of stent thrombosis (ST) after drug-eluting stent (DES) implantation varies among registries. To investigate differences in baseline characteristics and clinical outcome in European and Japanese all-comers registries, we performed a pooled analysis of patient-level data. Methods and results: The j-Cypher registry (JC) is a multicentre observational study conducted in Japan, including 12,824 patients undergoing SES implantation. From the Bern-Rotterdam registry (BR) enrolled at two academic hospitals in Switzerland and the Netherlands, 3,823 patients with SES were included in the current analysis. Patients in BR were younger, more frequently smokers and presented more frequently with ST-elevation myocardial infarction (MI). Conversely, JC patients more frequently had diabetes and hypertension. At five years, the definite ST rate was significantly lower in JC than BR (JC 1.6% vs. BR 3.3%, p<0.001), while the unadjusted mortality tended to be lower in BR than in JC (BR 13.2% vs. JC 14.4%, log-rank p=0.052). After adjustment, the j-Cypher registry was associated with a significantly lower risk of all-cause mortality (HR 0.56, 95% CI: 0.49-0.64) as well as definite stent thrombosis (HR 0.46, 95% CI: 0.35-0.61). Conclusions: The baseline characteristics of the two large registries were different. After statistical adjustment, JC was associated with lower mortality and ST.
Resumo:
OBJECTIVES The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Minneapolis, Minnesota) and XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Abbott Park, Illinois) in the RESOLUTE (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) All-Comers trial. BACKGROUND Data on long-term outcomes of new-generation drug-eluting stents are limited, and predictors of repeat revascularization due to restenosis and/or progression of disease are largely unknown. METHODS Patients were randomly assigned to treatment with the R-ZES (n = 1,140) or the EES (n = 1,152). We assessed pre-specified safety and efficacy outcomes at 4 years including target lesion failure and stent thrombosis. Predictors of revascularization at 4 years were identified by Cox regression analysis. RESULTS At 4 years, the rates of target lesion failure (15.2% vs. 14.6%, p = 0.68), cardiac death (5.4% vs. 4.7%, p = 0.44), and target vessel myocardial infarction (5.3% vs. 5.4%, p = 1.00), clinically-indicated target lesion revascularization (TLR) (7.0% vs. 6.5%, p = 0.62), and definite/probable stent thrombosis (2.3% vs. 1.6%, p = 0.23) were similar with the R-ZES and EES. Independent predictors of TLR were age, insulin-treated diabetes, SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score, treatment of saphenous vein grafts, ostial lesions, and in-stent restenosis. Independent predictors of any revascularization were age, diabetes, previous percutaneous coronary intervention, absence of ST-segment elevation myocardial infarction, smaller reference vessel diameter, SYNTAX score, and treatment of left anterior descending, right coronary artery, saphenous vein grafts, ostial lesions, or in-stent restenosis. CONCLUSIONS R-ZES and EES demonstrated similar safety and efficacy throughout 4 years. TLR represented less than one-half of all repeat revascularization procedures. Patient- and lesion-related factors predicting the risk of TLR and any revascularization showed considerable overlap. (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention [RESOLUTE-AC]; NCT00617084).
Resumo:
AIM The optimal duration of dual antiplatelet therapy (DAPT) following the use of new generation drug-eluting stents is unknown. METHODS AND RESULTS The association between DAPT interruption and the rates of stent thrombosis (ST) and cardiac death/target-vessel myocardial infarction (CD/TVMI) in patients receiving a Resolute zotarolimus-eluting stent (R-ZES) was analysed in 4896 patients from the pooled RESOLUTE clinical programme. Daily acetylsalicylate (ASA) and a thienopyridine for 6-12 months were prescribed. A DAPT interruption was defined as any interruption of ASA and/or a thienopyridine of >1 day; long interruptions were >14 days. Three groups were analysed: no interruption, interruption during the first month, and >1-12 months. There were 1069 (21.83%) patients with a DAPT interruption and 3827 patients with no interruption. Among the 166 patients in the 1-month interruption group, 6 definite/probable ST events occurred (3.61%; all long DAPT interruptions), and among the 903 patients in the >1-12 months (60% occurred between 6 and 12 months) interruption group, 1 ST event occurred (0.11%; 2-day DAPT interruption). Among patients with no DAPT interruption, 32 ST events occurred (0.84%). Rates of CD/TVMI were 6.84% in the 1-month long interruption group, 1.41% in the >1-12 months long interruption group, and 4.08% in patients on continuous DAPT. CONCLUSION In a pooled population of patients receiving an R-ZES, DAPT interruptions within 1 month are associated with a high risk of adverse outcomes. Dual antiplatelet therapy interruptions between 1 and 12 months were associated with low rates of ST and adverse cardiac outcomes. Randomized clinical trials are needed to determine whether early temporary or permanent interruption of DAPT is truly safe. CLINICAL TRIALSGOV IDENTIFIERS NCT00617084; NCT00726453; NCT00752128; NCT00927940.