984 resultados para PERSONNEL DOSIMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 2012 we were awarded an Erasmus Intensive Programme grant to facilitate OPTIMAX 2013, a three week duration residential summer school held within the UK during August 2013. The summer school helped to further develop student radiographer skills in optimising x-radiation dose and image quality. With a major emphasis on visual techniques to determine image quality, lesion visibility, lesion detection performance and physical measures of image quality (eg signal to noise ratio (SNR)) we conducted controlled laboratory experiments on phantoms using Computed Radiography, CT and Full Field Digital Mammography. Mathematical modelling was used for radiation dose estimation. Sixty seven people from 5 European countries participated. This included 49 PhD, MSc and BSc students. Discipline areas included radiography, physics, biomedical science and nuclear medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem Digital com Radiação X

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às tecnologias da Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intensity Modulated Radiotherapy (IMRT) is a technique introduced to shape more precisely the dose distributions to the tumour, providing a higher dose escalation in the volume to irradiate and simultaneously decreasing the dose in the organs at risk which consequently reduces the treatment toxicity. This technique is widely used in prostate and head and neck (H&N) tumours. Given the complexity and the use of high doses in this technique it’s necessary to ensure as a safe and secure administration of the treatment, through the use of quality control programmes for IMRT. The purpose of this study was to evaluate statistically the quality control measurements that are made for the IMRT plans in prostate and H&N patients, before the beginning of the treatment, analysing their variations, the percentage of rejected and repeated measurements, the average, standard deviations and the proportion relations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente a Tomografia Computorizada (TC) é o método de imagem que mais contribui para a dose coletiva resultante de exposições médicas. Este estudo pretende determinar os valores de Índice de Dose de TC (CTDI) e produto dose-comprimento (DLP) para os exames de crânio e tórax em adultos num equipamento de TC multidetetores; e efetuar uma análise objetiva e subjetiva da qualidade da imagem. Determinaram-se os valores de CTDI e DLP utilizando uma câmara de ionização e fantomas de crânio e tórax. Efetuou-se ainda uma análise objetiva e subjetiva da qualidade da imagem com o fantoma Catphan® 500 e observadores, respetivamente. Os resultados obtidos foram superiores relativamente às Guidelines europeias no protocolo de crânio (CTDIvol = 80,13 mGy e DLP = 1209,22 mGy.cm) e inferiores no protocolo de tórax (CTDIvol = 8,37 mGy e DLP = 274,71 mGy.cm). Na análise objetiva da qualidade da imagem, à exceção da resolução de baixo contraste no protocolo de crânio, todos os outros critérios analisados estavam em conformidade com a legislação. Na análise subjetiva da qualidade da imagem existiu uma diferença estatisticamente significativa entre as classificações atribuídas pelos observadores às imagens nos parâmetros avaliados (p = 0,000-0,005).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the strengths and limitations of the Family Health Strategy from the perspective of health care professionals and the community. METHODS: Between June-August 2009, in the city of Vespasiano, Minas Gerais State, Southeastern Brazil, a questionnaire was used to evaluate the Family Health Strategy (ESF) with 77 healthcare professionals and 293 caregivers of children under five. Health care professional training, community access to health care, communication with patients and delivery of health education and pediatric care were the main points of interest in the evaluation. Logistic regression analysis was used to obtain odds ratios and 95% confidence intervals as well as to assess the statistical significance of the variables studied. RESULTS: The majority of health care professionals reported their program training was insufficient in quantity, content and method of delivery. Caregivers and professionals identified similar weaknesses (services not accessible to the community, lack of healthcare professionals, poor training for professionals) and strengths (community health worker-patient communications, provision of educational information, and pediatric care). Recommendations for improvement included: more doctors and specialists, more and better training, and scheduling improvements. Caregiver satisfaction with the ESF was found to be related to perceived benefits such as community health agent household visits (OR 5.8, 95%CI 2.8;12.1), good professional-patient relationships (OR 4.8, 95%CI 2.5;9.3), and family-focused health (OR 4.1, 95%CI 1.6;10.2); and perceived problems such as lack of personnel (OR 0.3, 95%CI 0.2;0.6), difficulty with access (OR 0.2, 95%CI 0.1;0.4), and poor quality of care (OR 0.3, 95%CI 0.1;0.6). Overall, 62% of caregivers reported being generally satisfied with the ESF services. CONCLUSIONS: Identifying the limitations and strengths of the Family Health Strategy from the healthcare professional and caregiver perspective may serve to advance primary community healthcare in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this working paper is presented information on the Portuguese labour market developed with the support of the European project WORKS-“Work organisation and restructuring in the knowledge society”. Is still a on the process article and thus commentaries are welcome. The structure is based on the following topics: a) The employment policy (Time regimes - time use, flexibility, part-time work, work-life balance -, and the work contracts regimes – wages, contract types, diversity); b) Education and training (skilling outcomes, rules on retraining and further training, employability schemes, transferability of skills); c) Equal opportunities (relevance of equal opportunity regulation for restructuring outcomes, the role of gender and age regulation); d) Restructuring effects (policy on transfer of personnel, policy on redundancies, and participation or voice in restructuring).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In Angola, malaria is an endemic disease having a major impact on the economy. The WHO recommends testing for all suspected malaria cases, to avoid the presumptive treatment of this disease. In malaria endemic regions laboratory technicians must be very comfortable with microscopy, the golden standard for malaria diagnosis, to avoid the incorrect diagnosis. The improper use of medication promotes drug resistance and undesirable side effects. The present study aims to assess the impact of a three-day refresher course on the knowledge of technicians, quality of blood smears preparation and accuracy of microscopy malaria diagnosis, using qPCR as reference method. Methods: This study was implemented in laboratories from three hospitals in different provinces of Angola: Bengo, Benguela and Luanda. In each laboratory samples were collected before and after the training course (slide with thin and thick blood smears, a dried blood spot and a form). The impact of the intervention was evaluated through a written test, the quality of slide preparation and the performance of microscopy. Results: It was found a significant increase on the written test median score, from 52.5% to 65.0%. A total of 973 slides were analysed to evaluate the quality of thick and thin blood smears. Considering all laboratories there was a significant increase in quality of thick and thin blood smears. To determine the performance of microscopy using qPCR as the reference method we used 1,028 samples. Benguela presented the highest values for specificity, 92.9% and 98.8% pre and post-course, respectively and for sensitivity the best pre-course was Benguela (75.9%) and post-course Luanda (75.0%). However, no significant increase in sensitivity and specificity after the training course was registered in any laboratory analysed. Discussion: The findings of this study support the need of continuous refresher training for microscopists and other laboratory staff. The laboratories should have a quality control programme to supervise the diagnosis and also to assess the periodicity of new training. However, other variables needed to be considered to have a correct malaria diagnosis, such as adequate equipment and reagents for staining and visualization, good working conditions, motivated and qualified personnel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.