975 resultados para Orthopedic implants
Resumo:
The authors report the study of eight children with diskitis diagnosed through clinical, neurogical and orthopedic evaluation. The evidence of self limiting inflammation or infection of the intervertebral disk space and of soft tissue were avaliable by image studies. Findings with routine roentgenograms, computed tomography and magnetic resonance imaging are discussed.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
OBJETIVO: avaliar a participação da protrusão mandibular ortopédica e da posição condilar na prevalência de sinais e sintomas de disfunção temporomandibular (DTM). METODOLOGIA: a amostra foi composta por 60 indivíduos divididos em 3 grupos, sendo o grupo I correspondente a indivíduos não tratados; o grupo II composto por jovens em tratamento com o Bionator; e o grupo III por jovens já tratados com este aparelho. Os indivíduos da amostra responderam a um questionário relativo aos principais sintomas de DTM, permitindo a classificação dos mesmos de acordo com a presença e severidade dessas disfunções. Esses jovens também se submeteram à avaliação da movimentação mandibular, palpação dos músculos mastigatórios e inspeção de ruídos articulares. Radiografias transcranianas padronizadas das ATMs direita e esquerda foram realizadas, para obtenção do grau de concentricidade condilar. RESULTADOS: os testes ANOVA, Kruskal-Wallis e qui-quadrado foram utilizados para análise dos dados. De acordo com os resultados do questionário anamnésico, 66,67% da amostra foram classificados com ausência de DTM; 30% com DTM leve e apenas 3,33% com DTM moderada, sem diferença entre os grupos estudados (p > 0,05). Quanto à concentricidade condilar, o grupo II apresentou os valores de menor concentricidade (côndilos mais anteriorizados), com diferença estatisticamente significante em relação ao grupo I (p < 0,05). Uma associação entre a concentricidade condilar e a prevalência de DTM, no entanto, não foi encontrada. CONCLUSÃO: a protrusão ortopédica, apesar de alterar a posição dos côndilos, não aumentou a prevalência de DTM na população estudada.
Resumo:
This case report describes the orthodontic treatment of a 32-year-old woman with a Class III malocclusion, whose chief compliant was her dentofacial esthetics. The pretreatment lateral cephalometric tracings showed the presence of a Class III dentoskeletal malocclusion with components of maxillary deficiency. After discussion with the patient, the treatment option included surgically assisted rapid maxillary expansion (SARME) followed by orthopedic protraction (Sky Hook) and Class III elastics. Patient compliance was excellent and satisfactory dentofacial esthetics was achieved after treatment completion.
Resumo:
OBJETIVO: o objetivo deste estudo prospectivo de 32 adolescentes com má oclusão de Classe II, divisão 1, associada a retrognatismo mandibular, tratados com aparelho de Herbst, construído sobre bandas e coroas metálicas, foi avaliar cefalometricamente as possíveis mudanças no padrão de crescimento facial. METODOLOGIA: as telerradiografias laterais foram obtidas ao início do tratamento (T1) e imediatamente após 12 meses de tratamento com o referido aparelho ortopédico (T2). Foram utilizados o quociente de Jarabak e o VERT de Ricketts (modificado) para determinação do padrão facial em T1 e T2. RESULTADOS: utilizando o quociente de Jarabak, os resultados evidenciaram que 27 casos (84,4%) apresentaram padrões hipodivergentes em T1 e permaneceram da mesma forma em T2. Cinco casos (15,6%) apresentaram padrão neutro em T1 e não exibiram mudanças em T2. Quando avaliado o VERT de Ricketts (modificado), não ocorreram mudanças no padrão facial em 31 pacientes. Em apenas um caso ocorreu mudança do tipo facial. CONCLUSÃO: baseado nos resultados obtidos, pode-se concluir que, após 12 meses de tratamento com aparelho de Herbst, não ocorreram mudanças verticais no padrão de crescimento facial dos pacientes estudados.
Resumo:
OBJETIVO: este estudo teve como objetivo avaliar a influência da largura do septo inter-radicular no local de inserção de mini-implantes autoperfurantes sobre o grau de estabilidade desses dispositivos de ancoragem. MÉTODOS: a amostra consistiu de 40 mini-implantes inseridos entre as raízes do primeiro molar e segundo pré-molar superiores de 21 pacientes, com o intuito de fornecer ancoragem para retração anterior. A largura do septo no local de inserção (LSI) foi mensurada nas radiografias pós-cirúrgicas e, sob esse aspecto, os mini-implantes foram divididos em dois grupos: grupo 1 (áreas críticas, LSI<3mm) e grupo 2 (áreas não críticas, LSI>3mm). A estabilidade dos mini-implantes foi avaliada mensalmente pela quantificação do grau de mobilidade e a partir dessa variável foi calculada a proporção de sucesso. Avaliou-se também: a quantidade de placa, altura de inserção, grau de sensibilidade e período de observação. RESULTADOS: os resultados obtidos demonstraram que não houve diferença estatisticamente significativa para o grau de mobilidade e proporção de sucesso entre os mini-implantes inseridos em septos de largura mesiodistal crítica e não crítica. A proporção de sucesso total encontrada foi de 90% e nenhuma variável demonstrou estar relacionada ao insucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujos mini-implantes apresentavam mobilidade, e que a falha desses dispositivos de ancoragem ocorria logo após sua inserção. CONCLUSÃO: a largura do septo inter-radicular no local de inserção não interferiu na estabilidade dos mini-implantes autoperfurantes avaliados neste estudo.
Resumo:
OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.
Resumo:
Among the different properties that influence bone apposition around implants, the chemical or biochemical composition of implant surface may interfere on its acceptance by the surrounding bone. The aim of this study was to investigate if a biofunctionalization of implant surface influences the bone apposition in a dog model and to compare it with other surfaces, such as a microstructured created by the grit-blasting/acid-etching process. Eight young adult male mongrel dogs had the bilateral mandibular premolars extracted and each one received 6 implants after 12 weeks, totaling 48 implants in the experiment. Four groups of implants were formed with the same microrough topography with or without some kind of biofunctionalization treatment. After histomorphometric analysis, it was observed that the modified microstructured surface with a "low concentration of the bioactive peptide" provided a higher adjacent bone density (54.6%) when compared to the other groups (microstructured + HA coating = 46.0%, microstructured only = 45.3% and microstructured + "high concentration of the bioactive peptide" = 40.7%), but this difference was not statistically significant. In conclusion, biofunctionalization of the implant surface might interfere in the bone apposition around implants, especially in terms of bone density. Different concentrations of bioactive peptide lead to different results.
Resumo:
The biological fixation between the dental implant surfaces and jaw bones should be considered a prerequisite for the long-term success of implant-supported prostheses. In this context, the implant surface modifications gained an important and decisive place in implant research over the last years. As the most investigated topic in, it aided the development of enhanced dental treatment modalities and the expansion of dental implant use. Nowadays, a large number of implant types with a great variety of surface properties and other features are commercially available and have to be treated with caution. Although surface modifications have been shown to enhance osseointegration at early implantation times, for example, the clinician should look for research evidence before selecting a dental implant for a specific use. This paper reviews the literature on dental implant surfaces by assessing in vitro and in vivo studies to show the current perspective of implant development. The review comprises quantitative and qualitative results on the analysis of bone-implant interface using micro and nano implant surface topographies. Furthermore, the perspective of incorporating biomimetic molecules (e.g.: peptides and bone morphogenetic proteins) to the implant surface and their effects on bone formation and remodeling around implants are discussed.
Resumo:
The aim of this study was to investigate the histological and histomorphometrical bone response to three Biosilicates with different crystal phases comparing them to Bioglass®45S5 implants used as control. Ceramic glass Biosilicate and Bioglass®45S5 implants were bilaterally inserted in rabbit femurs and harvested after 8 and 12 weeks. Histological examination did not revealed persistent inflammation or foreign body reaction at implantation sites. Bone and a layer of soft tissue were observed in close contact with the implant surfaces in the medullary canal. The connective tissue presented few elongated cells and collagen fibers located parallel to implant surface. Cortical portion after 8 weeks was the only area that demonstrated significant difference between all tested materials, with Biosilicate 1F and Biosilicate 2F presenting higher bone formation than Bioglass®45S5 and Biosilicate® vitreo (p=0.02). All other areas and periods were statistically non-significant (p>0.05). In conclusion, all tested materials were considered biocompatible, demonstrating surface bone formation and a satisfactory behavior at biological environment.
Resumo:
It has recently been reported that machined and microrough (micro) Brazilian titanium (Ti) implants have good production standards. The aim of this study was to evaluate in vivo bone formation around 2 different implant surfaces placed in dog's mandible. Thirty-two screw-typed Ti implants were used in this study. Mandibular premolars were extracted in 8 dogs and, after 12 weeks, 2 machined (Neodent Titamax, Brazil) and 2 micro implants (Neodent Titamax Porous, Brazil) were placed in each animal. Biopsies were taken at 3 and 8 weeks post-implantation and stained with Stevenel's blue and Alizarin red for histomorphometric measurements of bone-to-implant contact (BIC), bone area between threads (BABT) and bone area within the mirror area (BAMA). Data were analyzed statistically by two-way ANOVA (α=0.05). While at 3 weeks micro implants exhibited significantly more BIC than machined ones (55 ± 12.5% and 35.6 ± 15%, p<0.05), no significant difference in such parameter was detected at 8 weeks (51.2 ± 21% and 48.6 ± 18.1%, p>0.05). There were no significant differences in BABT and BAMA between the implants. Micro surfaces promoted higher contact osteogenesis. These data indicate that this commercial micro Ti implant surface enhances contact osteogenesis at an early post-implantation period when compared to the machined one.
Rehabilitation of severely resorbed edentulous mandible using the modified visor osteotomy technique
Resumo:
The prosthetic rehabilitation of an atrophic mandible is usually unsatisfactory due to the lack of support tissues, mainly bone and keratinized mucosa for treatment with osseointegrated implants or even conventional prosthesis. The prosthetic instability leads to social and functional limitations and chronic physical trauma decreasing the patient's quality of life. A 53-year-old female patient sought care at our surgical service complaining of impairment of her masticatory function associated with the instability of the lower total prosthetic denture. The clinical and complementary exams revealed edentulism in both arches, while the mandibular arch presented severe reabsorption resulting in denture instability and chronic trauma to the oral mucosa. The proposed treatment plan consisted in the mandibular rehabilitation with osseointegrated implants and fixed Brånemark's protocol prosthesis after mandibular reconstruction applying the modified visor osteotomy technique. The proposed technique offered predictable results for reconstruction of the severely resorbed edentulous mandible and posterior rehabilitation with osseointegrated implants.
Resumo:
This study evaluated the response of the subcutaneous connective tissue of BALB/c mice to root filling materials indicated for primary teeth: zinc oxide/eugenol cement (ZOE), Calen paste thickened with zinc oxide (Calen/ZO) and Sealapex sealer. The mice (n=102) received polyethylene tube implants with the materials, thereby forming 11 groups, as follows: I, II, III: Calen/ZO for 7, 21 and 63 days, respectively; IV, V, VI: Sealapex for 7, 21 and 63 days, respectively; VII, VIII, IX: ZOE for 7, 21 and 63 days, respectively; X and XI: empty tube for 7 and 21 days, respectively. The biopsied tissues were submitted to histological analysis (descriptive analysis and semi-quantitative analysis using a scoring system for collagen fiber formation, tissue thickness and inflammatory infiltrate). A quantitative analysis was performed by measuring the area and thickness of the granulomatous reactionary tissue (GRT). Data were analyzed by Kruskal-Wallis, ANOVA and Tukey's post-hoc tests (?=0.05). There was no significant difference (p>0.05) among the materials with respect to collagen fiber formation or GRT thickness. However, Calen/ZO produced the least severe inflammatory infiltrate (p<0.05). The area of the GRT was significantly smaller (p<0.05) for Calen/ZO and Sealapex. In conclusion, Calen/ZO presented the best tissue reaction, followed by Sealapex and ZOE.