917 resultados para Non-surgical intervention
Resumo:
OBJECTIVE: The success of open and endovascular repair of abdominal aortic aneurysms (AAA) is hampered by postoperative dilatation of the anatomical neck of the AAA, which is used for graft attachment. The purpose of this study was to determine whether the macroscopically non-diseased infrarenal aortic neck of AAA is histologically and biochemically altered at the time of operative repair. METHODS: We harvested full-thickness aortic wall samples as longitudinal stripes spanning from AAA neck to aneurysmal sac in 22 consecutive patients undergoing open surgical AAA repair. Control tissue was obtained from five organ donors and five deceased subjects undergoing autopsy without evidence of aneurysmal disease. We assessed aortic media thickness, number of intact elastic lamellar units, media destruction, and neovascularization grade and performed immunohistochemistry for matrix metalloproteinase (MMP)-9 and phosphorylated c-Jun N-terminal kinase (p-JNK). MMP-9 and p-JNK protein expressions were quantified using Western Blots. RESULTS: The median thickness of the aortic media was 1150 mum in control tissue (range, 1000-1300), 510 mum in aortic necks (250-900), and 200 mum in aortic sacs (50-500, P from nonparametric test for trend <.001). The number of intact elastic lamellar units was 33 in controls (range, 33-55), 12 in aortic necks (0-31) and three in aortic sacs (0-10, P < .001). The expression of MMP-9 and p-JNK as assessed by Western Blots (P = .007 and .061, respectively) and zymography (P for trend <.001) were up regulated in both the AAA neck and sac compared with controls. Except for p-JNK expression, differences between tissues were similar after the adjustment for age, gender, and type of sampling. CONCLUSION: The seemingly non-diseased infrarenal AAA neck in patients with AAA undergoing surgical repair shows histological signs of destruction and upregulation of potential drug targets.
Resumo:
Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning tool reported here consists of multiple fluidic chambers providing localized curvature control along the length of the attached silicon electrode array. The chambers consist of 200μm inner diameter PET (polyethylene therephthalate) tubes with 4μm wall thickness. The chambers are molded in a tapered helical configuration to correspond to the cochlear shape upon relaxation of the actuators. This ensures that the optimal electrode placement within the cochlea is retained after the positioning tool becomes dormant (for chronic implants). Actuation is achieved by injecting fluid into the PET chambers and regulating the fluidic pressure. The chambers are arranged in a stacked, overlapping design to provide fluid connectivity with the non-implantable pressure controller and allow for local curvature control of the device. The stacked tube configuration allows for localized curvature control of various areas along the length of the electrode and additional stiffening and actuating power towards the base. Curvature is affected along the entire length of a chamber and the result is cumulative in sections of multiple chambers. The actuating chambers are bonded to the back of a silicon electrode array.
Resumo:
Phenylketonuria, an autosomal recessive Mendelian disorder, is one of the most common inborn errors of metabolism. Although currently treated by diet, many suboptimal outcomes occur for patients. Neuropathological outcomes include cognitive loss, white matter abnormalities, and hypo- or demyelination, resulting from high concentrations and/or fluctuating levels of phenylalanine. High phenylalanine can also result in competitive exclusion of other large neutral amino acids from the brain, including tyrosine and tryptophan (essential precursors of dopamine and serotonin). This competition occurs at the blood brain barrier, where the L-type amino acid transporter, LAT1, selectively facilitates entry of large neutral amino acids. The hypothesis of these studies is that certain non-physiological amino acids (NPAA; DL-norleucine (NL), 2-aminonorbornane (NB; 2-aminobicyclo-(2,1,1)-heptane-2-carboxylic acid), α-aminoisobutyrate (AIB), and α-methyl-aminoisobutyrate (MAIB)) would competitively inhibit LAT1 transport of phenylalanine (Phe) at the blood-brain barrier interface. To test this hypothesis, Pah-/- mice (n=5, mixed gender; Pah+/-(n=5) as controls) were fed either 5% NL, 0.5% NB, 5% AIB or 3% MAIB (w/w 18% protein mouse chow) for 3 weeks. Outcome measurements included food intake, body weight, brain LNAAs, and brain monoamines measured via LCMS/MS or HPLC. Brain Phe values at sacrifice were significantly reduced for NL, NB, and MAIB, verifying the hypothesis that these NPAAs could inhibit Phe trafficking into the brain. However, concomitant reductions in tyrosine and methionine occurred at the concentrations employed. Blood Phe levels were not altered indicating no effect of NPAA competitors in the gut. Brain NL and NB levels, measured with HPLC, verified both uptake and transport of NPAAs. Although believed predominantly unmetabolized, NL feeding significantly increased blood urea nitrogen. Pah-/-disturbances of monoamine metabolism were exacerbated by NPAA intervention, primarily with NB (the prototypical LAT inhibitor). To achieve the overarching goal of using NPAAs to stabilize Phe transport levels into the brain, a specific Phe-reducing combination and concentration of NPAAs must be found. Our studies represent the first in vivo use of NL, NB and MAIB in Pah-/- mice, and provide proof-of-principle for further characterization of these LAT inhibitors. Our data is the first to document an effect of MAIB, a specific system A transport inhibitor, on large neutral amino acid transport.
Resumo:
Notwithstanding non-robotic, thoracoscopic preparation of the internal mammary artery (IMA) is a difficult surgical task, an appropriate experimental training model is lacking. We evaluated the young domestic pig for this purpose. Four domestic female pigs (30-40 kg body weight) were used for this study. Bilateral thoracoscopic preparation of the IMA was carried out under continuous, pressure controlled CO(2) insufflation. A 30 degrees rigid thoracoscope was inserted through a 10-mm port in the 5th/6th intercostal space (ICS) dorsally to the posterior axillary line. The dissection instrument (Ultracision Harmonic Scalpel) was inserted (5-mm port) in the 7th ICS at the posterior axillary line and the endo-forceps (5-mm port) in the 5th ICS at the posterior axillary line. Thoracoscopic IMA preparation in pig resulted more difficult than in man. A total of seven IMAs were prepared in their full intrathoracic length. A change in the preparation technique (lateral detachment of the endothoracic muscle) improved the safety of the procedure, allowing all four respective IMAs to be prepared safely, while the initial technique ensued an injury for 2 out of 3 vessels. The described young domestic pig model is suitable for experimental training of bilateral thoracoscopic IMA preparation.
Resumo:
The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechanical parameters of the spinal segment. Investigation of the viscoelastic properties as well as the dynamic spinal stiffness was performed during a minimally invasive procedure (microdiscectomy) on five patients. Measurements were performed intraoperatively and the protocol consisted of a dynamic part, where spinal stiffness was computed, and a static part, where force relaxation of the segment under constant elongation was studied. The repeatability of the measurement procedure was demonstrated with five replicated tests. The spinal segment tissues were found to have viscoelastic properties. Preliminary tests confirmed a decrease in stiffness after decompression surgery. Patients with non-relaxed muscles showed higher stiffness and relaxation rate compared to patients with relaxed muscles, which can be explained by the contraction and relaxation reflex of muscles under fast and then static elongation. The results show the usefulness of the biomechanical characterization of the human lumbar spinal segment to improve the understanding of the contribution of individual anatomical structures to spinal stability.
Resumo:
Surgery and other invasive therapies are complex interventions, the assessment of which is challenged by factors that depend on operator, team, and setting, such as learning curves, quality variations, and perception of equipoise. We propose recommendations for the assessment of surgery based on a five-stage description of the surgical development process. We also encourage the widespread use of prospective databases and registries. Reports of new techniques should be registered as a professional duty, anonymously if necessary when outcomes are adverse. Case series studies should be replaced by prospective development studies for early technical modifications and by prospective research databases for later pre-trial evaluation. Protocols for these studies should be registered publicly. Statistical process control techniques can be useful in both early and late assessment. Randomised trials should be used whenever possible to investigate efficacy, but adequate pre-trial data are essential to allow power calculations, clarify the definition and indications of the intervention, and develop quality measures. Difficulties in doing randomised clinical trials should be addressed by measures to evaluate learning curves and alleviate equipoise problems. Alternative prospective designs, such as interrupted time series studies, should be used when randomised trials are not feasible. Established procedures should be monitored with prospective databases to analyse outcome variations and to identify late and rare events. Achievement of improved design, conduct, and reporting of surgical research will need concerted action by editors, funders of health care and research, regulatory bodies, and professional societies.
Resumo:
Research on surgical interventions is associated with several methodological and practical challenges of which few, if any, apply only to surgery. However, surgical evaluation is especially demanding because many of these challenges coincide. In this report, the second of three on surgical innovation and evaluation, we discuss obstacles related to the study design of randomised controlled trials and non-randomised studies assessing surgical interventions. We also describe the issues related to the nature of surgical procedures-for example, their complexity, surgeon-related factors, and the range of outcomes. Although difficult, surgical evaluation is achievable and necessary. Solutions tailored to surgical research and a framework for generating evidence on which to base surgical practice are essential.
Resumo:
PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.
Resumo:
Preclinical disorders of glucose metabolism should be systematically included in the high-risk group for diabetes mellitus and affected individuals provided with preventive measures. Their underlying insulin resistance is determined with the help of a checklist and a method called homeostasis model assessment (HOMA). Patients with impaired fasting glucose (IFG) must change their lifestyles. If this does not lead to a response or the patient is unable to modify behavior, medication is required. In the case of manifest type 2 diabetes mellitus, a graded schedule is used for differential management, which should be based on nutritional and exercise therapy. Oral medication with metformin is probably the drug of choice in both obese and non-obese patients. It is crucial not to delay raising the level of treatment until HbA1c has fallen to within an unsatisfactory range (wait-and-see strategy). Rather, the level should be intensified when persistent exacerbation starts to become apparent (proactive therapy). In diabetes mellitus, the same guidelines for secondary prevention apply to the associated cardiovascular risk factors as with coronary heart disease. An intensified and, especially, early treatment is to be preferred over a conservative, wait-and-see approach, in this case as well.
Resumo:
We synthesized recombinant Echinococcus granulosus protoscolex recP29 antigen to be preliminarily assessed by ELISA and immunoblotting. RecP29-serology was carried out on 54 young patients with cystic echinococcosis (CE). Patients were classified into either cured (CCE) (n=40) or non-cured (NCCE) (n=14) CE patients. RecP29 ELISA showed a gradual decrease of antibody concentrations in all CCE cases that were initially (before treatment) seropositive to this antigen (25 out of 40) or that seroconverted following treatment. A complete seronegativity was reached within 3 years post-surgery in all of these cases. Conventional HCF ELISA yielded seronegativity in only 10% of initially recP29-seropositive CCE patients (P=0.086). Likewise, recP29 immunoblotting yielded seronegativity in 93% of 29 out of 40 initially recP29-immunoblot-positive CCE patients after 3 years follow-up, compared with 72% in the HCF immunoblotting (P=0.060). Eleven out of 14 NCCE patients were initially positive by recP29 ELISA, and 10 out of these maintained a marked anti-recP29 antibody reactivity until the endpoint of the follow-up period. All 14 NCCE cases were initially seropositive by recP29 immunoblotting, and 13 cases remained seropositive until the end of the study. Thus, recombinant P29 protein appears prognostically useful for monitoring those post-surgical CE cases with an initial seropositivity to this marker.
Resumo:
BACKGROUND The WHO-surgical checklist is strongly recommended as a highly effective yet economically simple intervention to improve patient safety. Its use and potentially influential factors were investigated as little data exist on the current situation in Switzerland. METHODS A cross-sectional online survey with members (N = 1378) of three Swiss professional associations of invasive health care professionals was conducted in German, French, and Italian. The survey assessed use of, knowledge of and satisfaction with the WHO-surgical checklist. T-Tests and ANOVA were conducted to test for differences between professional groups. Bivariate correlations were computed to test for associations between measures of knowledge and satisfaction. RESULTS 1090 (79.1%) reported the use of a surgical checklist. 346 (25.1%) use the WHO-checklist, 532 (38.6%) use the Swiss Patient Safety Foundation recommendations to avoid Wrong Site Surgery, and 212 (15.7%) reported the use of other checklists. Satisfaction with checklist use was generally high (doctors: 71.9% satisfied, nurses: 60.8% satisfied) and knowledge was moderate depending on the use of the WHO-checklist. No association between measures of subjective and objective knowledge was found. CONCLUSIONS Implementation of a surgical checklist remains an important task for health care institutions in Switzerland. Although checklist use is present in Switzerland on a regular basis, a substantial group of health care personnel still do not use a checklist as a routine. Influential factors and the associations among themselves need to be addressed in future studies in more detail.
Resumo:
BACKGROUND AND OBJECTIVE Epidemiologic and clinical studies have indicated that diabetes is a risk factor for periodontal disease progression and healing. The aim of the present study was to evaluate short-term healing after enamel matrix derivative (EMD) application in combined supra/infrabony periodontal defects in diabetic rats. MATERIAL AND METHODS Thirty male Wistar rats were initially divided into two groups, one with streptozotocin-induced diabetes and another one with healthy (non-diabetic) animals. Bony defects were surgically created on the mesial root of the first maxillary molars. After root surface planing and EDTA conditioning, EMD was applied to the roots at one side of the maxillae, while those on the contralateral sides were left untreated. Animals were killed 3 wk after surgery, and block sections were prepared for histologic and histomorphometric analysis. RESULTS There was statistically significant more gingival recession in diabetic animals than in non-diabetic animals. The length of the junctional epithelium was significantly shorter in the EMD-treated sites in both diabetic and normoglycemic rats. Sulcus depth and length of supracrestal soft connective tissue showed no statistically significant differences between groups. In all animals, new bone formation was observed. Although new bone occurred more frequently in healthy animals, the extent of new bone was not significantly different between groups. In none of the teeth, a layer of new cementum was detectable. EMD had no influence on bone or cementum regeneration. Adverse reactions such as excessive inflammation due to bacterial root colonization, ankylosis and bone fractures were exclusively observed in diabetic animals, irrespective of EMD treatment. CONCLUSION Within the limits of the present study, it can be concluded that periodontal healing was impaired in streptozotocin-induced diabetic rats. EMD had no beneficial effects on new bone and cementum formation during short-term healing in this defect model and could not ameliorate the adverse effects in the systemically compromised animals.
Resumo:
Rationale, aims and objectives The study aims to investigate the effects of a patient safety advisory on patients' risk perceptions, perceived behavioural control, performance of safety behaviours and experience of adverse incidents. Method Quasi-experimental intervention study with non-equivalent group comparison was used. Patients admitted to the surgical department of a Swiss large non-university hospital were included. Patients in the intervention group received a safety advisory at their first clinical encounter. Outcomes were assessed using a questionnaire at discharge. Odds ratios for control versus intervention group were calculated. Regression analysis was used to model the effects of the intervention and safety behaviours on the experience of safety incidents. Results Two hundred eighteen patients in the control and 202 in the intervention group completed the survey (75 and 77% response rates, respectively). Patients in the intervention group were less likely to feel poorly informed about medical errors (OR = 0.55, P = 0.043). There were 73.1% in the intervention and 84.3% in the control group who underestimated the risk for infection (OR = 0.51, CI 0.31-0.84, P = 0.009). Perceived behavioural control was lower in the control group (meanCon = 3.2, meanInt = 3.5, P = 0.010). Performance of safety-related behaviours was unaffected by the intervention. Patients in the intervention group were less likely to experience any safety-related incident or unsafe situation (OR for intervention group = 0.57, CI 0.38-0.87, P = 0.009). There were no differences in concerns for errors during hospitalization. There were 96% of patients (intervention) who would recommend other patients to read the advisory. Conclusions The results suggest that the safety advisory decreases experiences of adverse events and unsafe situations. It renders awareness and perceived behavioural control without increasing concerns for safety and can thus serve as a useful instrument for communication about safety between health care workers and patients.
Resumo:
OBJECTIVES This study sought to validate the Logistic Clinical SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score in patients with non-ST-segment elevation acute coronary syndromes (ACS), in order to further legitimize its clinical application. BACKGROUND The Logistic Clinical SYNTAX score allows for an individualized prediction of 1-year mortality in patients undergoing contemporary percutaneous coronary intervention. It is composed of a "Core" Model (anatomical SYNTAX score, age, creatinine clearance, and left ventricular ejection fraction), and "Extended" Model (composed of an additional 6 clinical variables), and has previously been cross validated in 7 contemporary stent trials (>6,000 patients). METHODS One-year all-cause death was analyzed in 2,627 patients undergoing percutaneous coronary intervention from the ACUITY (Acute Catheterization and Urgent Intervention Triage Strategy) trial. Mortality predictions from the Core and Extended Models were studied with respect to discrimination, that is, separation of those with and without 1-year all-cause death (assessed by the concordance [C] statistic), and calibration, that is, agreement between observed and predicted outcomes (assessed with validation plots). Decision curve analyses, which weight the harms (false positives) against benefits (true positives) of using a risk score to make mortality predictions, were undertaken to assess clinical usefulness. RESULTS In the ACUITY trial, the median SYNTAX score was 9.0 (interquartile range 5.0 to 16.0); approximately 40% of patients had 3-vessel disease, 29% diabetes, and 85% underwent drug-eluting stent implantation. Validation plots confirmed agreement between observed and predicted mortality. The Core and Extended Models demonstrated substantial improvements in the discriminative ability for 1-year all-cause death compared with the anatomical SYNTAX score in isolation (C-statistics: SYNTAX score: 0.64, 95% confidence interval [CI]: 0.56 to 0.71; Core Model: 0.74, 95% CI: 0.66 to 0.79; Extended Model: 0.77, 95% CI: 0.70 to 0.83). Decision curve analyses confirmed the increasing ability to correctly identify patients who would die at 1 year with the Extended Model versus the Core Model versus the anatomical SYNTAX score, over a wide range of thresholds for mortality risk predictions. CONCLUSIONS Compared to the anatomical SYNTAX score alone, the Core and Extended Models of the Logistic Clinical SYNTAX score more accurately predicted individual 1-year mortality in patients presenting with non-ST-segment elevation acute coronary syndromes undergoing percutaneous coronary intervention. These findings support the clinical application of the Logistic Clinical SYNTAX score.
Resumo:
OBJECTIVES The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Inc., Santa Rosa, California) in patients with coronary artery disease and diabetes. BACKGROUND The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. METHODS We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. RESULTS The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p < 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with noninsulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). CONCLUSIONS The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with noninsulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Medtronic RESOLUTE Clinical Trial; NCT00248079; Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; The Medtronic RESOLUTE US Clinical Trial (R-US); NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [R-Int]; NCT00752128; RESOLUTE Japan-The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent [RJ]; NCT00927940).