962 resultados para Mortar and concrete


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this research was to investigate the reason lumps occur in high-slump concrete and develop adequate batching procedures for a lumps-free high-slump ready-mix concrete mix used by the Florida Department of Transportation. Cement balls are round lumps of cement, sand, and coarse aggregate, typically about the size of a baseball that frequently occur in high-slump concrete. Such lumps or balls jeopardize the structural integrity of structural members. Experiments were conducted at the CSR Rinker concrete plant in Miami, Florida, based on a protocol developed by a team of Florida Department of Transportation (FDOT) concrete engineers, Rinker personnel, and Florida International University faculty. A total of seventeen truckloads were investigated in two phases, between April 2001 and March 2002. The tests consisted of gathering data by varying load size, discharge rate, headwater content, and mixing revolutions. The major finding was that a usual load size and discharge rate, an initial headwater ratio of 30%, and an initial number of revolutions of 100 at 12 revolutions per minute seem to produce a lump-free high-slump concrete. It was concluded that inadequate mixing and batching procedures caused cement lumps. Recommendations regarding specific load size, discharge rates, number of mixing revolutions, and initial water content are made. Clear guidelines for a high-slump concrete batching protocol can be developed, with further testing based on these research conclusions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A debate is currently prevalent among the structural engineers regarding the use of cracked versus un-cracked moment of inertia of the structural elements in analyzing and designing tall concrete buildings. (The basic definition of a tall building, according to the Journal of Structural Design of Tall Buildings Vol. 13. No. 5, 2004 is a structure that is equal to or greater than 160 feet in height, or 6 stories or greater.) The controversy is the result of differing interpretations of certain ACI (American Concrete Institute) code provisions. The issue is whether designers should use cracked moment of inertia in order to estimate lateral deflection and whether the computed lateral deflection should be used to carry out subsequent second-order analysis (analysis considering the effect of first order lateral deflections on bending moment and shear stresses). On one hand, bending moments and shear forces estimated based on un-cracked moment of inertia of the sections may result in conservative designs by overestimating moments and shears. On the other hand, lateral deflections may be underestimated due to the same analyses resulting in unsafe designs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main goal of research presented in this paper was the material and radiological characterization of high volume fly ash concrete (HVFAC) in terms of determination of natural radionuclide content and radon emanation and exhalation coefficients. All concrete samples were made with a fly ash content between 50% and 70% of the total amount of cementitious materials from one coal burning power plant in Serbia. Physical (fresh and hardened concrete density) and mechanical properties (compressive strength, splitting tensile strength and modulus of elasticity) of concrete were tested. The radionuclide content (226Ra, 232Th and 40K) and radon massic exhalation of HVFAC samples were determined using gamma spectrometry. Determination of massic exhalation rates of HVFAC and its components using radon accumulation chamber techniques combined with a radon monitor was performed. The results show a beneficial effect of pozzolanic activity since the increase in fly ash content resulted in an increase in compressive strength of HVFAC by approximately 20% for the same mass of cement used in the mixtures. On the basis of the obtained radionuclide content of concrete components the I -indices of different HVFAC samples were calculated and compared with measured values (0.27e0.32), which were significantly below the recommended 1.0 index value. The prediction was relatively close to the measured values as the ratio between the calculated and measured I-index ranged between 0.89 and 1.14. Collected results of mechanical and radiological properties and performed calculations clearly prove that all 10 designed concretes with a certain type of fly ash are suitable for structural and non-structural applications both from a material and radiological point of view.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The building sector requires the worldwide production of 4 billion tonnes of cement annually, consuming more than 40% of global energy and accounting for about 8% of the total CO2 emissions. The SUS-CON project aimed at integrating waste materials in the production cycle of concrete, for both ready-mixed and pre-cast applications, resulting in an innovative light-weight, ecocompatible and cost-effective construction material, made by all-waste materials and characterized by enhanced thermal insulation performance and low embodied energy and CO2. Alkali activated “cementless” binders, which have recently emerged as eco-friendly construction materials, were used in conjunction with lightweight recycled aggregates to produce sustainable concrete for a range of applications. This paper presents some results from the development of a concrete made with a geopolymeric binder (alkali activated fly ash) and aggregate from recycled mixed plastic. Mix optimisation was achieved through an extensive investigation on production parameters for binder and aggregate. The mix recipe was developed for achieving the required fresh and hardened properties. The optimised mix gave compressive strength of about 7 MPa, flexural strength of about 1.3 MPa and a thermal conductivity of 0.34 W/mK. Fresh and hardened properties were deemed suitable for the industrial production of precast products. Precast panels were designed and produced for the construction of demonstration buildings. Mock-ups of about 2.5 x 2.5 x 2.5 m were built at a demo park in Spain both with SUS-CON and Portland cement concrete, monitoring internal and external temperatures. Field results indicate that the SUS-CON mock-ups have better insulation. During the warmest period of the day, the measured temperature in the SUS-CON mock-ups was lower.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the important factors in the use of portland cement concrete is its durability, and most of the situations where durability is lacking have been identifi ed and strategies to manage durability have been implemented. Geopolymer concrete, made from an alkali-activated natural pozzolan (AANP), provides an important opportunity for the reduction of carbon dioxide (CO2) emissions associated with the manufacture of concrete but has a limited history of durability studies. Until its different properties are well understood there is no desire to adopt this new technology of unknown provenance by the concrete industry. This paper presents an experimental study of oxygen and chloride permeability of AANP concrete prepared by activating Taftan andesite and Shahindej dacite (Iranian natural pozzolans), with and without calcining, and the correlations between these properties and compressive strength. The results show that compared to ordinary portland cement (OPC) concrete, AANP concrete has lower oxygen permeability at later ages; but it shows moderate to high chloride ion penetrability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Internal curing is a relatively new technique being used to promote hydration of Portland cement concretes. The fundamental concept is to provide reservoirs of water within the matrix such that the water does not increase the initial water/cementitious materials ratio to the mixture, but is available to help continue hydration once the system starts to dry out. The reservoirs used in the US are typically in the form of lightweight fine aggregate (LWFA) that is saturated prior to batching. Considerable work has been conducted both in the laboratory and in the field to confirm that this approach is fundamentally sound and yet practical for construction purposes. A number of bridge decks have been successfully constructed around the US, including one in Iowa in 2013. It is reported that inclusion of about 20% to 30% LWFA will not only improve strength development and potential durability, but, more importantly, will significantly reduce shrinking, thus reducing cracking risk. The aim of this work was to investigate the feasibility of such an approach in a bridge deck.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This demonstration project consisted of three adjacent highway resurfacing projects using asphalt cement concrete removed from an Interstate highway which had become severely rutted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dans la région de Trois-Rivières (Québec, Canada), plus de 1 000 bâtiments résidentiels et commerciaux montrent de graves problèmes de détérioration du béton. Les problèmes de détérioration sont liés à l’oxydation des sulfures de fer incorporés dans le granulat utilisé pour la confection du béton. Ce projet de doctorat vise à mieux comprendre les mécanismes responsables de la détérioration de béton incorporant des granulats contenant des sulfures de fer, et ce afin de développer une méthodologie pour évaluer efficacement la réactivité potentielle de ce type de granulats. Un examen pétrographique détaillé de carottes de béton extraites de fondations résidentielles montrant différents degré d’endommagement a été réalisé. Le granulat problématique contenant des sulfures de fer a été identifié comme un gabbro à hypersthène incorporant différentes proportions (selon les différentes localisations dans les deux carrières d’origine) de pyrrhotite, pyrite, chalcopyrite et pentlandite. Les produits de réaction secondaires observés dans les échantillons dégradés comprennent des formes minérales de "rouille", gypse, ettringite et thaumasite. Ces observations ont permis de déterminer qu’en présence d’eau et d’oxygène, la pyrrhotite s’oxyde pour former des oxyhydroxides de fer et de l’acide sulfurique qui provoquent une attaque aux sulfates dans le béton. Tout d’abord, la fiabilité de l’approche chimique proposée dans la norme européenne NF EN 12 620, qui consiste à mesurer la teneur en soufre total (ST,% en masse) dans le granulat pour détecter la présence (ou non) de sulfures de fer, a été évaluée de façon critique. Environ 50% (21/43) des granulats testés, représentant une variété de types de roches/lithologies, a montré une ST > 0,10%, montrant qu’une proportion importante de types de roches ne contient pas une quantité notable de sulfure, qui, pour la plupart d’entre eux, sont susceptibles d’être inoffensifs dans le béton. Ces types de roches/granulats nécessiteraient toutefois d’autres tests pour identifier la présence potentielle de pyrrhotite compte tenu de la limite de ST de 0,10 % proposée dans les normes européennes. Basé sur une revue exhaustive de la littérature et de nombreuses analyses de laboratoire, un test accéléré d’expansion sur barres de mortier divisé en deux phases a ensuite été développé pour reproduire, en laboratoire, les mécanismes de détérioration observés à Trois-Rivières. Le test consiste en un conditionnement de 90 jours à 80°C/80% RH, avec 2 cycles de mouillage de trois heures chacun, par semaine, dans une solution d’hypochlorite de sodium (eau de javel) à 6% (Phase I), suivi d’une période pouvant atteindre 90 jours de conditionnement à 4°C/100 % HR (Phase II). Les granulats ayant un potentiel d’oxydation ont présenté une expansion de 0,10 % au cours de la Phase I, tandis que la formation potentielle de thaumasite est détectée par le regain rapide de l’expansion suivi par la destruction des échantillons durant la Phase II. Un test de consommation d’oxygène a également été modifié à partir d’un test de Drainage Minier Acide, afin d’évaluer quantitativement le potentiel d’oxydation des sulfures de fer incorporés dans les granulats à béton. Cette technique mesure le taux de consommation d’oxygène dans la partie supérieure d’un cylindre fermé contenant une couche de matériau compacté afin de déterminer son potentiel d’oxydation. Des paramètres optimisés pour évaluer le potentiel d’oxydation des granulats comprennent une taille de particule inférieure à 150 μm, saturation à 40 %, un rapport de 10 cm d’épaisseur de granulat par 10 cm de dégagement et trois heures d’essai à 22ᵒC. Les résultats obtenus montrent que le test est capable de discriminer les granulats contenant des sulfures de fer des granulats de contrôle (sans sulfures de fer) avec un seuil limite fixé à 5% d’oxygène consommé. Finalement, un protocole d’évaluation capable d’estimer les effets néfastes potentiels des granulats à béton incorporant des sulfures de fer a été proposé. Le protocole est divisé en 3 grandes phases: (1) mesure de la teneur en soufre total, (2) évaluation de la consommation d’oxygène, et (3) un test accéléré d’expansion sur barres de mortier. Des limites provisoires sont proposées pour chaque phase du protocole, qui doivent être encore validées par la mise à l’essai d’un plus large éventail de granulats.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this project was to evaluate the location and quantities of debonding in selected portland cement concrete (PCC) overlays. The project entailed an infrared thermographic survey and a ground penetrating radar survey of the PCC overlays to locate areas of debonding between the overlays and the original pavement. An infrared scanner is capable of locating these areas because of the temperature differential which is established between bonded and debonded areas under certain environmental conditions. A conventional video inspection of the top surface of the pavement was also completed in conjunction with the infrared thermographic survey to record the visual condition of the pavement surface. The ground penetrating radar system is capable of locating areas of debonding by detecting return wave forms generated by changes in the dielectric properties at the PCC overlay original pavement interface. This report consists of two parts; a text and a set of plan sheets. The text summarizes the procedures, analyses and conclusions of the investigation. The plan sheets locate specific areas of debonding, as identified through field observations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Presented in this report is an investigation of the use of "sand-lightweight" concrete in prestressed concrete structures. The sand-lightweight concrete consists of 100% sand substitution for fines, along with Idealite coarse and medium lightweight aggregate and Type I Portland Cement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In February of 1968 a cooperative research project by the Iowa State Highway Commission (Project No. HR-136) and the University of Iowa, Iowa City, Iowa was initiated in order to determine experimentally the creep and shrinkage characteristics of lightweight-aggregate concrete used in the State of Iowa. This report is concerned with Phase 1 of the Project as described in the Prospectus for the project submitted in November of 1967: "The State Highway Commission is planning to conduct pilot studies in prestressed-lightweight structures fabricated with materials that are proposed for use in bridge structures in the near future. Thus, Phase will have as its immediate objective, investigating the materials to be used in the above mentioned pilot studies.” (1) The work described in this report was also carried out in conjunction with a second cooperative project: "Time-Dependent Camber and Deflection of Non-Composite and Composite Lightweight-Prestressed Concrete Beams" (Project No. HR-137).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-08