992 resultados para Molar Heat-capacity
Resumo:
This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.
Resumo:
The application of forced unsteady-state reactors in case of selective catalytic reduction of nitrogen oxides (NOx) with ammonia (NH3) is sustained by the fact that favorable temperature and composition distributions which cannot be achieved in any steady-state regime can be obtained by means of unsteady-state operations. In a normal way of operation the low exothermicity of the selective catalytic reduction (SCR) reaction (usually carried out in the range of 280-350°C) is not enough to maintain by itself the chemical reaction. A normal mode of operation usually requires supply of supplementary heat increasing in this way the overall process operation cost. Through forced unsteady-state operation, the main advantage that can be obtained when exothermic reactions take place is the possibility of trapping, beside the ammonia, the moving heat wave inside the catalytic bed. The unsteady state-operation enables the exploitation of the thermal storage capacity of the catalyticbed. The catalytic bed acts as a regenerative heat exchanger allowing auto-thermal behaviour when the adiabatic temperature rise is low. Finding the optimum reactor configuration, employing the most suitable operation model and identifying the reactor behavior are highly important steps in order to configure a proper device for industrial applications. The Reverse Flow Reactor (RFR) - a forced unsteady state reactor - corresponds to the above mentioned characteristics and may be employed as an efficient device for the treatment of dilute pollutant mixtures. As a main disadvantage, beside its advantages, the RFR presents the 'wash out' phenomena. This phenomenon represents emissions of unconverted reactants at every switch of the flow direction. As a consequence our attention was focused on finding an alternative reactor configuration for RFR which is not affected by the incontrollable emissions of unconverted reactants. In this respect the Reactor Network (RN) was investigated. Its configuration consists of several reactors connected in a closed sequence, simulating a moving bed by changing the reactants feeding position. In the RN the flow direction is maintained in the same way ensuring uniformcatalyst exploitation and in the same time the 'wash out' phenomena is annulated. The simulated moving bed (SMB) can operate in transient mode giving practically constant exit concentration and high conversion levels. The main advantage of the reactor network operation is emphasizedby the possibility to obtain auto-thermal behavior with nearly uniformcatalyst utilization. However, the reactor network presents only a small range of switching times which allow to reach and to maintain an ignited state. Even so a proper study of the complex behavior of the RN may give the necessary information to overcome all the difficulties that can appear in the RN operation. The unsteady-state reactors complexity arises from the fact that these reactor types are characterized by short contact times and complex interaction between heat and mass transportphenomena. Such complex interactions can give rise to a remarkable complex dynamic behavior characterized by a set of spatial-temporal patterns, chaotic changes in concentration and traveling waves of heat or chemical reactivity. The main efforts of the current research studies concern the improvement of contact modalities between reactants, the possibility of thermal wave storage inside the reactor and the improvement of the kinetic activity of the catalyst used. Paying attention to the above mentioned aspects is important when higher activity even at low feeding temperatures and low emissions of unconverted reactants are the main operation concerns. Also, the prediction of the reactor pseudo or steady-state performance (regarding the conversion, selectivity and thermal behavior) and the dynamicreactor response during exploitation are important aspects in finding the optimal control strategy for the forced unsteady state catalytic tubular reactors. The design of an adapted reactor requires knowledge about the influence of its operating conditions on the overall process performance and a precise evaluation of the operating parameters rage for which a sustained dynamic behavior is obtained. An apriori estimation of the system parameters result in diminution of the computational efforts. Usually the convergence of unsteady state reactor systems requires integration over hundreds of cycles depending on the initial guess of the parameter values. The investigation of various operation models and thermal transfer strategies give reliable means to obtain recuperative and regenerative devices which are capable to maintain an auto-thermal behavior in case of low exothermic reactions. In the present research work a gradual analysis of the SCR of NOx with ammonia process in forced unsteady-state reactors was realized. The investigation covers the presentationof the general problematic related to the effect of noxious emissions in the environment, the analysis of the suitable catalysts types for the process, the mathematical analysis approach for modeling and finding the system solutions and the experimental investigation of the device found to be more suitable for the present process. In order to gain information about the forced unsteady state reactor design, operation, important system parameters and their values, mathematical description, mathematicalmethod for solving systems of partial differential equations and other specific aspects, in a fast and easy way, and a case based reasoning (CBR) approach has been used. This approach, using the experience of past similarproblems and their adapted solutions, may provide a method for gaining informations and solutions for new problems related to the forced unsteady state reactors technology. As a consequence a CBR system was implemented and a corresponding tool was developed. Further on, grooving up the hypothesis of isothermal operation, the investigation by means of numerical simulation of the feasibility of the SCR of NOx with ammonia in the RFRand in the RN with variable feeding position was realized. The hypothesis of non-isothermal operation was taken into account because in our opinion ifa commercial catalyst is considered, is not possible to modify the chemical activity and its adsorptive capacity to improve the operation butis possible to change the operation regime. In order to identify the most suitable device for the unsteady state reduction of NOx with ammonia, considering the perspective of recuperative and regenerative devices, a comparative analysis of the above mentioned two devices performance was realized. The assumption of isothermal conditions in the beginningof the forced unsteadystate investigation allowed the simplification of the analysis enabling to focus on the impact of the conditions and mode of operation on the dynamic features caused by the trapping of one reactant in the reactor, without considering the impact of thermal effect on overall reactor performance. The non-isothermal system approach has been investigated in order to point out the important influence of the thermal effect on overall reactor performance, studying the possibility of RFR and RN utilization as recuperative and regenerative devices and the possibility of achieving a sustained auto-thermal behavior in case of lowexothermic reaction of SCR of NOx with ammonia and low temperature gasfeeding. Beside the influence of the thermal effect, the influence of the principal operating parameters, as switching time, inlet flow rate and initial catalyst temperature have been stressed. This analysis is important not only because it allows a comparison between the two devices and optimisation of the operation, but also the switching time is the main operating parameter. An appropriate choice of this parameter enables the fulfilment of the process constraints. The level of the conversions achieved, the more uniform temperature profiles, the uniformity ofcatalyst exploitation and the much simpler mode of operation imposed the RN as a much more suitable device for SCR of NOx with ammonia, in usual operation and also in the perspective of control strategy implementation. Theoretical simplified models have also been proposed in order to describe the forced unsteady state reactors performance and to estimate their internal temperature and concentration profiles. The general idea was to extend the study of catalytic reactor dynamics taking into account the perspectives that haven't been analyzed yet. The experimental investigation ofRN revealed a good agreement between the data obtained by model simulation and the ones obtained experimentally.
Resumo:
Background: Understanding the relationship between gene expression changes, enzyme activity shifts, and the corresponding physiological adaptive response of organisms to environmental cues is crucial in explaining how cells cope with stress. For example, adaptation of yeast to heat shock involves a characteristic profile of changes to the expression levels of genes coding for enzymes of the glycolytic pathway and some of its branches. The experimental determination of changes in gene expression profiles provides a descriptive picture of the adaptive response to stress. However, it does not explain why a particular profile is selected for any given response. Results: We used mathematical models and analysis of in silico gene expression profiles (GEPs) to understand how changes in gene expression correlate to an efficient response of yeast cells to heat shock. An exhaustive set of GEPs, matched with the corresponding set of enzyme activities, was simulated and analyzed. The effectiveness of each profile in the response to heat shock was evaluated according to relevant physiological and functional criteria. The small subset of GEPs that lead to effective physiological responses after heat shock was identified as the result of the tuning of several evolutionary criteria. The experimentally observed transcriptional changes in response to heat shock belong to this set and can be explained by quantitative design principles at the physiological level that ultimately constrain changes in gene expression. Conclusion: Our theoretical approach suggests a method for understanding the combined effect of changes in the expression of multiple genes on the activity of metabolic pathways, and consequently on the adaptation of cellular metabolism to heat shock. This method identifies quantitative design principles that facilitate understating the response of the cell to stress.
Resumo:
La presencia de materiales fenicios en el curso del río Ebro se ha relacionado con su interés hacia los recursos mineros de nordeste peninsular en general y del área Molar-Bellmunt-Falset en particular, pero hasta la fecha esta propuesta no había sido adecuadamente contratada. En este artículo presentamos las primeras evidencias de actividad metalúrgica procedente del poblado de Calvari del Molar (Priorat, Tarragona) (campañas 2002-2003), que consisten en una tobera de tipología desconocida hasta la fecha en Cataluña, un molino empleado para triturar el mineral y una punta de flecha orientalizante que puede interpretarse como una imitación local de modelos foráneos. Damos a conocer también el estudio arqueometalúrgico de otros cuatro bronces procedentes de las excavaciones de S. Vilaseca (1930). La publicación de los resultados arqueológicos y arqueométricos nos sirve para presentar las perspectivas de futuro de nuestra investigación acerca del poblado, de su área minero-metalúrgica y de su relación con los intereses comerciales fenicios. Se presta especial atención a la plata, obtenida a partir de minerales de este metal, plata nativa y galena argentífera, como un subproducto de la explotación de plomo.
Resumo:
We have analyzed the heat stress response in the yeast Saccharomyces cerevisiae by determining mRNA levels and transcription rates for the whole transcriptome after a shift from 25uC to 37uC. Using an established mathematical algorithm, theoretical mRNA decay rates have also been calculated from the experimental data. We have verified the mathematical predictions for selected genes by determining their mRNA decay rates at different times during heat stress response using the regulatable tetO promoter. This study indicates that the yeast response to heat shock is not only due to changes in transcription rates, but also to changes in the mRNA stabilities. mRNA stability is affected in 62% of the yeast genes and it is particularly important in shaping the mRNA profile of the genes belonging to the environmental stress response. In most cases, changes in transcription rates and mRNA stabilities are homodirectional for both parameters, although some interesting cases of antagonist behavior are found. The statistical analysis of gene targets and sequence motifs within the clusters of genes with similar behaviors shows that both transcriptional and post-transcriptional regulons apparently contribute to the general heat stress response by means of transcriptional factors and RNA binding proteins.
Resumo:
The complexing capacity of synthetic (0.011 M tartrate in 13.5% ethanol) and real wine (Raimat Abadia) in titrations with added total Zn concentrations up to 0.03 M has been determined following the free Zn concentrations with AGNES (absence of gradients and Nernstian equilibrium stripping) technique. A correction to find the preconcentration factor or gain (Y1) really applied at each one of the ionic strengths reached due to Zn additions along the titration has been applied. The standard implementation of AGNES to real wine led to the observation of two anomalous behaviors: (a) an increasingly negative current in the deposition stage (labeled as “HER” effect) and (b) a minimum in the currents of the stripping stage plot (labeled as the “dip” effect). A practical strategy to apply AGNES avoiding the dip effect has been developed to quantify properly free Zn concentrations. The van den Berg–Ružic–Lee linearization method (assuming the existence of just 1:1 complexes) has been adapted to consider the dilution effect and the ionic strength changes. Aggregated stability constants and total ligand concentrations have been calculated from synthetic and wine titration data. The found complexing capacity in the studied wine (cT,L = 0.0179 ± 0.0007 M) indicates the contribution of ligands other than tartrate (which is confirmed to be the main one).
Resumo:
Training and competition in major track-and-field events, and for many team or racquet sports, often require the completion of maximal sprints in hot (>30 °C) ambient conditions. Enhanced short-term (<30 s) power output or single-sprint performance, resulting from transient heat exposure (muscle temperature rise), can be attributed to improved muscle contractility. Under heat stress, elevations in skin/core temperatures are associated with increased cardiovascular and metabolic loads in addition to decreasing voluntary muscle activation; there is also compelling evidence to suggest that large performance decrements occur when repeated-sprint exercise (consisting of brief recovery periods between sprints, usually <60 s) is performed in hot compared with cool conditions. Conversely, poorer intermittent-sprint performance (recovery periods long enough to allow near complete recovery, usually 60-300 s) in hotter conditions is solely observed when exercise induces marked hyperthermia (core temperature >39 °C). Here we also discuss strategies (heat acclimatization, precooling, hydration strategies) employed by "sprint" athletes to mitigate the negative influence of higher environmental temperatures.
Resumo:
Electricity is a strategic service in modern societies. Thus, it is extremely important for governments to be able to guarantee an affordable and reliable supply, which depends to a great extent on an adequate expansion of the generation and transmission capacities. Cross- border integration of electricity markets creates new challenges for the regulators, since the evolution of the market is now influenced by the characteristics and policies of neighbouring countries. There is still no agreement on why and how regions should integrate their electricity markets. The aim of this thesis is to improve the understanding of integrated electricity markets and how their behaviour depends on the prevailing characteristics of the national markets and the policies implemented in each country. We developed a simulation model to analyse under what circumstances integration is desirable. This model is used to study three cases of interconnection between two countries. Several policies regarding interconnection expansion and operation, combined with different generation capacity adequacy mechanisms, are evaluated. The thesis is composed of three papers. The first paper presents a detailed description of the model and an analysis of the case of Colombia and Ecuador. It shows that market coupling can bring important benefits, but the relative size of the countries can lead to import dependency issues in the smaller country. The second paper compares the case of Colombia and Ecuador with the case of Great Britain and France. These countries are significantly different in terms of electricity sources, hydro- storage capacity, complementarity and demand growth. We show that complementarity is essential in order to obtain benefits from integration, while higher demand growth and hydro- storage capacity can lead to counterintuitive outcomes, thus complicating policy design. In the third paper, an extended version of the model presented in the first paper is used to analyse the case of Finland and its interconnection with Russia. Different trading arrangements are considered. We conclude that unless interconnection capacity is expanded, the current trading arrangement, where a single trader owns the transmission rights and limits the flow during peak hours, is beneficial for Finland. In case of interconnection expansion, market coupling would be preferable. We also show that the costs of maintaining a strategic reserve in Finland are justified in order to limit import dependency, while still reaping the benefits of interconnection. In general, we conclude that electricity market integration can bring benefits if the right policies are implemented. However, a large interconnection capacity is only desirable if the countries exhibit significant complementarity and trust each other. The outcomes of policies aimed at guaranteeing security of supply at a national level can be quite counterintuitive due to the interactions between neighbouring countries and their effects on interconnection and generation investments. Thus, it is important for regulators to understand these interactions and coordinate their decisions in order to take advantage of the interconnection without putting security of supply at risk. But it must be taken into account that even when integration brings benefits to the region, some market participants lose and might try to hinder the integration process. -- Dans les sociétés modernes, l'électricité est un service stratégique. Il est donc extrêmement important pour les gouvernements de pouvoir garantir la sécurité d'approvisionnement à des prix abordables. Ceci dépend en grande mesure d'une expansion adéquate des capacités de génération et de transmission. L'intégration des marchés électriques pose des nouveaux défis pour les régulateurs, puisque l'évolution du marché est maintenant influencée par les caractéristiques et les politiques des pays voisins. Il n'est pas encore claire pourquoi ni comment les marches électriques devraient s'intégrer. L'objectif de cette thèse est d'améliorer la compréhension des marchés intégrés d'électricité et de leur comportement en fonction des caractéristiques et politiques de chaque pays. Un modèle de simulation est proposé pour étudier les conditions dans lesquelles l'intégration est désirable. Ce modèle est utilisé pour étudier trois cas d'interconnexion entre deux pays. Plusieurs politiques concernant l'expansion et l'opération de l'interconnexion, combinées avec différents mécanismes de rémunération de la capacité, sont évalués. Cette thèse est compose de trois articles. Le premier présente une description détaillée du modèle et une analyse du cas de la Colombie et de l'Equateur. Il montre que le couplage de marchés peut amener des bénéfices importants ; cependant, la différence de taille entre pays peut créer des soucis de dépendance aux importations pour le pays le plus petit. Le second papier compare le cas de la Colombie et l'Equateur avec le cas de la Grande Bretagne et de la France. Ces pays sont très différents en termes de ressources, taille des réservoirs d'accumulation pour l'hydro, complémentarité et croissance de la demande. Nos résultats montrent que la complémentarité joue un rôle essentiel dans l'obtention des bénéfices potentiels de l'intégration, alors qu'un taux élevé de croissance de la demande, ainsi qu'une grande capacité de stockage, mènent à des résultats contre-intuitifs, ce qui complique les décisions des régulateurs. Dans le troisième article, une extension du modèle présenté dans le premier article est utilisée pour analyser le cas de la Finlande et de la Russie. Différentes règles pour les échanges internationaux d'électricité sont considérées. Nos résultats indiquent qu'à un faible niveau d'interconnexion, la situation actuelle, où un marchand unique possède les droits de transmission et limite le flux pendant les heures de pointe, est bénéfique pour la Finlande. Cependant, en cas d'expansion de la capacité d'interconnexion, «market coupling» est préférable. préférable. Dans tous les cas, la Finlande a intérêt à garder une réserve stratégique, car même si cette politique entraine des coûts, elle lui permet de profiter des avantages de l'intégration tout en limitant ca dépendance envers les importations. En général, nous concluons que si les politiques adéquates sont implémentées, l'intégration des marchés électriques peut amener des bénéfices. Cependant, une grande capacité d'interconnexion n'est désirable que si les pays ont une complémentarité importante et il existe une confiance mutuelle. Les résultats des politiques qui cherchent à préserver la sécurité d'approvisionnement au niveau national peuvent être très contre-intuitifs, étant données les interactions entre les pays voisins et leurs effets sur les investissements en génération et en interconnexion. Il est donc très important pour les régulateurs de comprendre ces interactions et de coordonner décisions à fin de pouvoir profiter de l'interconnexion sans mettre en danger la sécurité d'approvisionnement. Mais il faut être conscients que même quand l'intégration amène de bénéfices pour la région, certains participants au marché sont perdants et pourraient essayer de bloquer le processus d'intégration.
Resumo:
Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.
Resumo:
The effect of the heat flux on the rate of chemical reaction in dilute gases is shown to be important for reactions characterized by high activation energies and in the presence of very large temperature gradients. This effect, obtained from the second-order terms in the distribution function (similar to those obtained in the Burnett approximation to the solution of the Boltzmann equation), is derived on the basis of information theory. It is shown that the analytical results describing the effect are simpler if the kinetic definition for the nonequilibrium temperature is introduced than if the thermodynamic definition is introduced. The numerical results are nearly the same for both definitions
Resumo:
Selostus: Paljasjyväisen kauran kuoriutuvuus ja säilyvyys
Resumo:
Työn tavoitteena oli selvittää UPM-Kymmenen Rauman voimalaitokselle soveltuvan kaukolämpöakun prosessikytkentä, optimaalinen koko ja investoinnin kannattavuus. Lisäksi ratkaistiin funktio, jolla voidaan määrittää optimaalinen kaukolämpöakun koko kaukolämpöverkon koon perusteella. Teoriaosassa käsiteltiin investointien ja lämmön varastoinnin perusteita käyttämällä hyväksi kirjallisuutta. Soveltavassa osassa tietoa kerättiin kirjallisuuden lisäksi asiantuntijoiden haastatteluilla. Teorian ja kannattavuuslaskelmien perusteella toteutettavaksi ratkaisuksi valittiin suorakytkentäinen paineistettu kaukolämpöakku. Valitun akun purkaus- ja latustehoiksi saatiin 40 MW, akun tilavuudeksi 1 700 m³, korkeudeksi 33 m ja halkaisijaksi 8 m. Investonnin sisäinen korko on 16,6 prosenttia. Kannattavuuslaskelmien ja herkkyystarkastelun perusteella investointi on kannattava. Kaukolämpöverkkoon rakennattavan akun optimaalinen koko voidaan määrittää funktiolla: y = -0,0102x² +9,6605x +68,395 , jossa y on akun tilavuus ja x verkon kaukolämpöenergian vuosittainen kulutus.
Resumo:
The objective of the present study was to characterize the chemistry and the antioxidant capacity in 8 species of native fruits from Amazonia. All the fruits were collected at full physiological and commercial maturity from properties located at: Boa Vista / RR, São Luiz do Anauá / RR, Manaus / AM, and Belém / PA. At the end of the experiment, the functional pattern for the camu-camu fruits showed that the total phenolic and ascorbic acid content and antioxidant assays were superior compared to the other samples. Despite the functional losses detected for the freeze-dried samples of the camu-camu fruit, all the other freeze-dried samples kept under -20ºC showed appropriate stability for long-term storage. In addition, it was also observed that fruit peel showed higher antioxidant activity than pulp or samples containing peel and pulp tissues in the same extract. When the ratio between the ORAC and total phenolic assays were observed, the uxi fruit demonstrated the highest antioxidant power compared to the other fruits studied, despite its relatively low levels of phenolic compound content and ORAC values. This means that there is a relevant contribution of these phenolic compounds to the antioxidant activity of uxi fruit.