966 resultados para Minos element
Resumo:
Advances in surgical procedure, prosthesis design, and biomaterials performance have considerably increased the longevity of total joint replacements. Preoperative planning is another step in joint replacement that may have the potential to improve clinical outcome for the individual patient, but has remained relatively consistent for a longtime. One means of advancing this aspect of joint replacement surgery may be to include predictive computer simulation into the planning process. In this article, the potential of patient-specific finite element analysis in preoperative assessment is investigated. Seventeen patient-specific finite element models of cemented Charnley reconstructions were created, of which six were early (
Resumo:
Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.
Resumo:
Trace elements have been cited as both inhibitory and causative agents of cancer but importantly exposure to them is potentially modifiable. Our study aimed to examine toenail trace element status and risk of Barrett's oesophagus (BO) and oesophageal adenocarcinoma (OAC). Toenail clippings from each hallux were obtained from 638 participants of the FINBAR (Factors Influencing the Barrett's Adenocarcinoma Relationship) study comprising 221 healthy controls, 98 reflux oesophagitis, 182 BO and 137 OAC cases. The concentrations of eight toenail trace elements were determined using instrumental neutron activation analysis. Using multivariable adjusted logistic regression analysis, odds ratios (OR) and 95% confidence intervals (CIs) were calculated within tertiles of trace element concentrations. A twofold increased risk of BO was observed, but not OAC, among individuals in the highest tertile of toenail zinc status OR 2.21 (95% CI, 1.11-4.40). A higher toenail selenium status was not associated with risk of OAC OR 0.94 (95% CI, 0.44-2.04) or BO OR 0.89 (95% CI, 0.37-2.12). A borderline significant increased risk of BO was detected with a higher toenail cobalt concentration, OR 1.97 (95% CI, 1.01-3.85). No association was found between toenail levels of chromium, cerium, mercury and OAC or BO risk. This is the first case-control study to investigate a variety of trace elements in relation to OAC and BO risk. Despite antioxidant and proapoptotic properties, no associations were found with selenium. Higher concentrations of toenail zinc and cobalt were associated with an increased BO risk, but not OAC. These findings need confirmation in prospective analysis.
Resumo:
Punching failure is the common failure mode in concrete bridge deck slabs when these structural components are subjected to local patch loads, such as tyre loads. Past research has shown that reinforced concrete slabs in girder–slab type bridges have a load-carrying capacity far greater than the ultimate static loads predicted by traditional design methods, because of the presence of compressive membrane action. However, due to the instability problems from punching failure, it is difficult to predict ultimate capacities accurately in numerical analyses. In order to overcome the instability problems, this paper establishes an efficient non-linear finite-element analysis using the commercial finite-element package Abaqus. In the non-linear finite-element analysis, stabilisation methods were adopted and failure criteria were established to predict the ultimate punching behaviour of deck slabs in composite steel–concrete bridges. The proposed non-linear finite-element analysis predictions showed a good correlation on punching capacities with experimental tests.
Resumo:
Erythrocytosis arises from a variety of pathogenic mechanisms. We sequenced a 256-bp region 3' to the erythropoietin (Epo) gene which included a 24- to 50-bp minimal hypoxia-responsive element spanning HIF-1- and HNF-4-binding sites in 12 patients with erythrocytosis and 4 normal subjects. Four polymorphisms were found, none of which affected the HIF-1-binding site, although one polymorphism was present in the HNF-4 consensus region. The data indicate that none of these polymorphisms cause erythrocytosis.