979 resultados para Minimal lethal concentration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of sucrose concentration in the culture medium on growth and on the establishment of mycorrhizas during the acclimatization of pineapple cv. Pérola. The plantlets were micropropagated in MS culture medium with 0, 10, 20 and 30 g L-1 of sucrose and then they were acclimatized during 12 weeks under greenhouse conditions, in a sandy soil - compost mixture, uninoculated or inoculated with a Rhizophagus clarus isolate. Plantlets from the culture medium with 20 g and 30 g of sucrose L-1 showed higher shoot and root biomass than those from sugar-free medium. Mycorrhizal colonization was lower in plantlets micropropagated in sucrose-free medium, but the intensity of arbuscules did not differ among treatments. In the 12-week period of acclimatization, mycorrhizal colonization had no effect on plant biomass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Va/Ba strain, constructed by Sperlich et al. (1977), is the only balanced lethal strain in D. subobscura. It allows the production of homozygous O chromosomes and has been a useful tool not only to analyse chromosomal viabilities but also to obtain homokaryotypic lines (Mestres and Serra, 2008). Besides the morphological dominant mutations Va (Varicose) and Ba (Bare), other genetic markers have been characterized in this strain, some of them by our group and not described previously. Here we present a list of these markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinematics of the anatomical shoulder are analysed and modelled as a parallel mechanism similar to a Stewart platform. A new method is proposed to describe the shoulder kinematics with minimal coordinates and solve the indeterminacy. The minimal coordinates are defined from bony landmarks and the scapulothoracic kinematic constraints. Independent from one another, they uniquely characterise the shoulder motion. A humanoid mechanism is then proposed with identical kinematic properties. It is then shown how minimal coordinates can be obtained for this mechanism and how the coordinates simplify both the motion-planning task and trajectory-tracking control. Lastly, the coordinates are also shown to have an application in the field of biomechanics where they can be used to model the scapulohumeral rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans le néphron distal sensible à l'aldostérone, le récepteur aux minéralocorticoïdes (RM) et le récepteur aux glucocorticoids (RG) sont exprimés et peuvent être liés et activés par l'aldostérone et le Cortisol, respectivement. La réabsorption rénale de sodium est principalement contrôlée par le RM. Cependant, des modèles expérimentaux in vitro et in vivo suggèrent que le RG pourrait également jouer un rôle dans le transport rénal du sodium. Afin d'étudier l'implication du RG et/ou du RM exprimés dans les cellules épithéliales adultes dans le transport rénal du sodium, nous avons généré deux modèles de souris, dans lesquelles l'expression du RG (Nr3c1Pax8/LC1) ou du RM (Nr3c2Pax8/LC1) peut être abolie de manière inductible et cela spécifiquement dans les tubules rénaux. Les souris déficientes pour le gène du RM survivent mais développent un phénotype sévère de PHA-1, caractérisé par un retard de croissance, une augmentation des niveaux urinaires de Na+, une diminution de la concentration du Na+ dans le plasma, une hyperkaliémie et une augmentation des niveaux d'aldostérone plasmatique. Ce phénotype empire et devient létal lorsque les souris sont nourries avec une diète déficiente en sodium. Les niveaux d'expression en protéine de NCC, de la forme phosphorylée de NCC et de aENaC sont diminués, alors que l'expression en ARN messager et en protéine du RG est augmentée. Une diète riche en Na+ et pauvre en K+ ne corrige pas la concentration élevée d'aldostérone dans le plasma pour la ramener à des niveaux conformes, mais est suffisante pour corriger la perte de poids et les niveaux anormaux des électrolytes dans le plasma et l'urine. -- In the aldosterone-sensitive distal nephron, both the mineralocorticoid (MR) and the glucocorticoid (GR) receptor are expressed. They can be bound and activated by aldosterone and Cortisol, respectively. Renal Na+ reabsorption is mainly controlled by MR. However, in vitro and in vivo experimental models suggest that GR may play a role in renal Na+ transport. Therefore, to investigate the implication of MR and/or GR in adult epithelial cells in renal sodium transport, we generated inducible renal tubule- specific MR (Nr3c2Pax8/LC1) and GR (Nr3c1Pax8/LC1) knockout mice. MR-deficient mice survived but developed a severe PHA-1 phenotype with failure to thrive, higher urinary Na+, decreased plasma Na+ levels, hyperkalemia and higher levels of plasma aldosterone. This phenotype further worsened and became lethal under a sodium-deficient diet. NCC protein expression and its phosphorylated form, as well as aENaC protein level were downregulated, whereas the mRNA and protein expression of GR was increased. A diet rich in Na+and low in K+ did not normalize plasma aldosterone to control levels, but was sufficient to restore body weight, plasma and urinary electrolytes. Upon switch to a Na+-deficient diet, GR-mutant mice exhibited transient increased urinary Na+ and decreased K+ levels, with transitory higher plasma K+ concentration preceded by a significant increase in plasma aldosterone levels within the 12 hours following diet switch. We found no difference in urinary aldosterone levels, plasma Na+ concentration and plasma corticosterone levels. Moreover, NHE3, NKCC2, NCC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality.Materials and Methods:Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration.Results:As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions.Conclusion:Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper empirically analyzes changes in the supply of non-stop intercontinental flights from European airports. We take advantage of OAG data for air services from a rich sample of European airports to intercontinental destinations in the period 2004-2008. Results of the empirical analysis indicate a tendency towards a more balanced distribution of intercontinental flights across European airports. We also find that the demographic size of a region, its sector specialization, the political role of its central city and the proportion of connecting traffic explain the amount of and changes in long-haul air services supplied from European airports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of casein concentration, Ca2+ concentration, temperature and pH on the amount and size of protein aggregates (fines) in the whey produced by enzimic coagulation of nonfat milk was studied in laboratory conditions. Casein concentrations about 0.3 g/L showed a minimal amount of caseins in the whey, with presence of small aggregates of casein micellles. Ca2+ concentrations higher than 5 mM were neccesary to reduce the whey protein to a minimum constituted by protein particles smaller than casein micelles. The coagulation temperature, in the 35 - 45oC range, produced almost no variations in the whey proteins. The obtention of a minimum amount of whey proteins was possible only in a narrow pH range around 6.4. These results pointed to casein concentration and pH as important variables to be controlled in connection with the process yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epsilon toxin (Etx) from Clostridium perfringens is a pore-forming protein with a lethal effect on livestock, producing severe enterotoxemia characterized by general edema and neurological alterations. Site-specific mutations of the toxin are valuable tools to study the cellular and molecular mechanism of the toxin activity. In particular, mutants with paired cysteine substitutions that affect the membrane insertion domain behaved as dominant-negative inhibitors of toxin activity in MDCK cells. We produced similar mutants, together with a well-known non-toxic mutant (Etx-H106P), as green fluorescent protein (GFP) fusion proteins to perform in vivo studies in an acutely intoxicated mouse model. The mutant (GFP-Etx-I51C/A114C) had a lethal effect with generalized edema, and accumulated in the brain parenchyma due to its ability to cross the blood-brain barrier (BBB). In the renal system, this mutant had a cytotoxic effect on distal tubule epithelial cells. The other mutants studied (GFP-Etx-V56C/F118C and GFP-Etx-H106P) did not have a lethal effect or cross the BBB, and failed to induce a cytotoxic effect on renal epithelial cells. These data suggest a direct correlation between the lethal effect of the toxin, with its cytotoxic effect on the kidney distal tubule cells, and the ability to cross the BBB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viruses are among the most important pathogens present in water contaminated with feces or urine and represent a serious risk to human health. Four procedures for concentrating viruses from sewage have been compared in this work, three of which were developed in the present study. Viruses were quantified using PCR techniques. According to statistical analysis and the sensitivity to detect human adenoviruses (HAdV), JC polyomaviruses (JCPyV) and noroviruses genogroup II (NoV GGII): (i) a new procedure (elution and skimmed-milk flocculation procedure (ESMP)) based on the elution of the viruses with glycine-alkaline buffer followed by organic flocculation with skimmed-milk was found to be the most efficient method when compared to (ii) ultrafiltration and glycine-alkaline elution, (iii) a lyophilization-based method and (iv) ultracentrifugation and glycine-alkaline elution. Through the analysis of replicate sewage samples, ESMP showed reproducible results with a coefficient of variation (CV) of 16% for HAdV, 12% for JCPyV and 17% for NoV GGII. Using spiked samples, the viral recoveries were estimated at 30-95% for HAdV, 55-90% for JCPyV and 45-50% for NoV GGII. ESMP was validated in a field study using twelve 24-h composite sewage samples collected in an urban sewage treatment plant in the North of Spain that reported 100% positive samples with mean values of HAdV, JCPyV and NoV GGII similar to those observed in other studies. Although all of the methods compared in this work yield consistently high values of virus detection and recovery in urban sewage, some require expensive laboratory equipment. ESMP is an effective low-cost procedure which allows a large number of samples to be processed simultaneously and is easily standardizable for its performance in a routine laboratory working in water monitoring. Moreover, in the present study, a CV was applied and proposed as a parameter to evaluate and compare the methods for detecting viruses in sewage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viruses are among the most important pathogens present in water contaminated with feces or urine and represent a serious risk to human health. Four procedures for concentrating viruses from sewage have been compared in this work, three of which were developed in the present study. Viruses were quantified using PCR techniques. According to statistical analysis and the sensitivity to detect human adenoviruses (HAdV), JC polyomaviruses (JCPyV) and noroviruses genogroup II (NoV GGII): (i) a new procedure (elution and skimmed-milk flocculation procedure (ESMP)) based on the elution of the viruses with glycine-alkaline buffer followed by organic flocculation with skimmed-milk was found to be the most efficient method when compared to (ii) ultrafiltration and glycine-alkaline elution, (iii) a lyophilization-based method and (iv) ultracentrifugation and glycine-alkaline elution. Through the analysis of replicate sewage samples, ESMP showed reproducible results with a coefficient of variation (CV) of 16% for HAdV, 12% for JCPyV and 17% for NoV GGII. Using spiked samples, the viral recoveries were estimated at 30-95% for HAdV, 55-90% for JCPyV and 45-50% for NoV GGII. ESMP was validated in a field study using twelve 24-h composite sewage samples collected in an urban sewage treatment plant in the North of Spain that reported 100% positive samples with mean values of HAdV, JCPyV and NoV GGII similar to those observed in other studies. Although all of the methods compared in this work yield consistently high values of virus detection and recovery in urban sewage, some require expensive laboratory equipment. ESMP is an effective low-cost procedure which allows a large number of samples to be processed simultaneously and is easily standardizable for its performance in a routine laboratory working in water monitoring. Moreover, in the present study, a CV was applied and proposed as a parameter to evaluate and compare the methods for detecting viruses in sewage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our first objective is to compare the degree of concentration in manufacturing and services, with special emphasis on its evolution in these two sectors, using a sensitivity analysis for different concentration indices and different geographic units of analysis: municipalities and local labour systems of Catalonia in 1991 and 2001. Most concentration measures fail to consider the space in which a particular municipality is located. Our second objective is to overcome this problem by applying two different techniques: by using a clustering measure, and by analysing whether the location quotients computed for each municipality and sector present some kind of spatial autocorrelation process. We take special account of the differences in patterns of concentration according to the technological level of the sectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.