994 resultados para Microwave Imaging Breast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in signal analysis have engendered EEG with the status of a true brain mapping and brain imaging method capable of providing spatio-temporal information regarding brain (dys)function. Because of the increasing interest in the temporal dynamics of brain networks, and because of the straightforward compatibility of the EEG with other brain imaging techniques, EEG is increasingly used in the neuroimaging community. However, the full capability of EEG is highly underestimated. Many combined EEG-fMRI studies use the EEG only as a spike-counter or an oscilloscope. Many cognitive and clinical EEG studies use the EEG still in its traditional way and analyze grapho-elements at certain electrodes and latencies. We here show that this way of using the EEG is not only dangerous because it leads to misinterpretations, but it is also largely ignoring the spatial aspects of the signals. In fact, EEG primarily measures the electric potential field at the scalp surface in the same way as MEG measures the magnetic field. By properly sampling and correctly analyzing this electric field, EEG can provide reliable information about the neuronal activity in the brain and the temporal dynamics of this activity in the millisecond range. This review explains some of these analysis methods and illustrates their potential in clinical and experimental applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This poster highlights the fact that alcohol increases the risk of developing breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This leaflet is used to support the Northern Ireland breast screening programme and describes how women should check their breasts regularly for any changes that are new to them

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Public Health Agency is using National Breastfeeding Awareness Week (NBAW) to emphasise the message that breastfeeding is the healthiest option for both you and your baby and that by deciding to breastfeed, you will be giving your child the best possible start in life. NBAW runs from 19-25 June and highlights the fact that any period of breastfeeding, however short, will benefit your baby.Breast milk is different to formula milk as it contains antibodies that cannot be manufactured in formula. Antibodies help protect babies from infection and stimulate their immune system.Northern Ireland has the lowest breastfeeding rate in the UK, with an average of 63% of women breastfeeding their baby at birth. Janet Calvert, Regional Breastfeeding Coordinator at the PHA, said: "This is an issue that clearly needs addressed, as breastfeeding has many important health benefits for both mother and baby. These include a reduced risk of ear, chest, kidney and stomach infections and less risk of childhood diabetes and obesity."Breastfeeding can also significantly reduce the risk of hospital admission of children for gastroenteritis and chest infections. The health benefits for mothers who choose to breastfeed include a reduced risk of developing illnesses such as breast cancer, ovarian cancer and osteoporosis."There are other benefits as well as those to your health. Breastfeeding is free - you don't have to buy formula, bottles, teats, sterilising equipment etc. Breast milk is always available, with the right ingredients, at the right temperature, so it's easier to feed at night or on the go.The PHA recognises the importance of breastfeeding to health and the need to ensure that mothers get off to a good start with breastfeeding. It is vital that mothers get the right support and encouragement from their family and friends should they decide to breastfeed. Breastfeeding can be difficult at the start and mothers need reassurance while they learn."There are many local initiatives in the community to improve breastfeeding support. These include improving support in the health service and through Sure Start programmes, which work in areas of need to help ensure children get the best start in life," Janet added."Mother to mother peer support programmes are in place in many areas and are working with expectant and new mothers to help them breastfeed for longer. There are also 70 breastfeeding support groups, which provide ongoing support for breastfeeding mothers throughout Northern Ireland. "The PHA is also working to improve attitudes to breastfeeding in public through the Breastfeeding Welcome Here scheme, which began in 2005 and now has over 200 businesses and public facilities signed up to support and welcome breastfeeding families. All these initiatives, along with support from partners and family, are vital to help expectant and new mothers stay with breastfeeding."Health Minister Edwin Poots said: "There is clear evidence that breastfeeding offers health benefits for both babies and mothers. We know that breast milk gives baby the best start in life by providing all the nutrients and protection a baby needs for the first six months of life. That is why my Department is committed to promoting and supporting breastfeeding".For further information on breastfeeding visit www.breastfedbabies.org.uk

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighted spin-echo imaging of the spine has been successfully implemented for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Nevertheless, this technique still suffers from insufficient image quality in numerous patients due to motion artifacts. The aim of this study was to investigate the impact of variable respiratory motion artifact suppression techniques on image quality in diffusion-weighted spin-echo imaging of the spine. In addition to phase-encoding reordering, a newly implemented right hemi-diaphragmaitc navigator for respiratory gating was used. Subjective and objective image quality parameters were compared. Respiratory motion artifact suppression has a major impact on image quality in diffusion-weighted imaging of the spine. Phase-encoding reordering does not enhance image quality while right hemi-diaphragmatic respiratory navigator gating significantly improves image quality at the cost of data acquisition time. Navigator gating should be used if standard spin-echo diffusion-weighted imaging demonstrates insufficient image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomarker analysis is playing an essential role in cancer diagnosis, prognosis, and prediction. Quantitative assessment of immunohistochemical biomarker expression on tumor tissues is of clinical relevance when deciding targeted treatments for cancer patients. Here, we report a microfluidic tissue processor that permits accurate quantification of the expression of biomarkers on tissue sections, enabled by the ultra-rapid and uniform fluidic exchange of the device. An important clinical biomarker for invasive breast cancer is human epidermal growth factor receptor 2 [(HER2), also known as neu], a transmembrane tyrosine kinase that connotes adverse prognostic information for the patients concerned and serves as a target for personalized treatment using the humanized antibody trastuzumab. Unfortunately, when using state-of-the-art methods, the intensity of an immunohistochemical signal is not proportional to the extent of biomarker expression, causing ambiguous outcomes. Using our device, we performed tests on 76 invasive breast carcinoma cases expressing various levels of HER2. We eliminated more than 90% of the ambiguous results (n = 27), correctly assigning cases to the amplification status as assessed by in situ hybridization controls, whereas the concordance for HER2-negative (n = 31) and -positive (n = 18) cases was 100%. Our results demonstrate the clinical potential of microfluidics for accurate biomarker expression analysis. We anticipate our technique will be a diagnostic tool that will provide better and more reliable data, onto which future treatment regimes can be based.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The EORTC 22922/10925 trial investigated the potential survival benefit and toxicity of elective irradiation of the internal mammary and medial supraclavicular (IM-MS) nodes Accrual completed in January 2004 and first results are expected in 2012. We present the toxicity reported until year 3 after treatment. PATIENTS AND METHODS: At each visit, toxicity was reported but severity was not graded routinely. Toxicity rates and performance status (PS) changes at three years were compared by chi(2) tests and logistic regression models in all the 3,866 of 4,004 patients eligible to the trial who received the allocated treatment. RESULTS: Only lung (fibrosis; dyspnoea; pneumonitis; any lung toxicities) (4.3% vs. 1.3%; p < 0.0001) but not cardiac toxicity (0.3% vs. 0.4%; p = 0.55) significantly increased with IM-MS treatment. No significant worsening of the PS was observed (p = 0.79), suggesting that treatment-related toxicity does not impair patient's daily activities. CONCLUSIONS: IM-MS irradiation seems well tolerated and does not significantly impair WHO PS at three years. A follow-up period of at least 10 years is needed to determine whether cardiac toxicity is increased after radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The Fragile X - associated Tremor Ataxia Syndrome (FXTAS) is a recently described, and under-diagnosed, late onset (≈ 60y) neurodegenerative disorder affecting male carriers of a premutation in the Fragile X Mental Retardation 1 (FMR1) gene. The premutation is an CGG (Cytosine-Guanine-Guanine) expansion (55 to 200 CGG repeats) in the proximal region of the FMR1 gene. Patients with FXTAS primarily present with cerebellar ataxia and intention tremor. Neuroradiological features of FXTAS include prominent white matter disease in the periventricular, subcortical, middle cerebellar peduncles and deep white matter of the cerebellum on T2-weighted or FLAIR MR imaging (Jacquemmont 2007, Loesch 2007, Brunberg 2002, Cohen 2006). We hypothesize that a significant white matter alteration is present in younger individuals many years prior to clinical symptoms and/or the presence of visible lesions on conventional MR sequences and might be detectable by magnetization transfer (MT) imaging. Methods: Eleven asymptomatic premutation carriers (mean age = 55 years) and seven intra-familial controls participated to the study. A standardized neurological examination was performed on all participants and a neuropsychological evaluation was carried out before MR scanning performed on a 3T Siemens Trio. The protocol included a sagittal T1-weighted 3D gradient-echo sequence (MPRAGE, 160 slices, 1 mm^3 isotropic voxels) and a gradient-echo MTI (FA 30, TE 15, matrix size 256*256, pixel size 1*1 mm, 36 slices (thickness 2mm), MT pulse duration 7.68 ms, FA 500, frequency offset 1.5 kHz). MTI was performed by acquiring consecutively two set of images; first with and then without the MT saturation pulse. MT images were coregistered to the T1 acquisition. The MTR for every intracranial voxel was calculated as follows: MTR = (M0 - MS)/M0*100%, creating a MTR map for each subject. As first analysis, the whole white matter (WM) was used to mask the MTR image in order to create an histogram of the MTR distribution in the whole tissue class over the two groups examined. Then, for each subject, we performed a segmentation and parcellation of the brain by means of Freesurfer software, starting from the high resolution T1-weighted anatomical acquisition. Cortical parcellations was used to assign a label to the underlying white matter by the construction of a Voronoi diagram in the WM voxels of the MR volume based on distance to the nearest cortical parcellation label. This procedure allowed us to subdivide the cerebral WM in 78 ROIs according to the cortical parcellation (see example in Fig 1). The cerebellum, by the same procedure, was subdivided in 5 ROIs (2 per each hemisphere and one corresponding to the brainstem). For each subject, we calculated the mean value of MTR within each ROI and averaged over controls and patients. Significant differences between the two groups were tested using a two sample T-test (p<0.01). Results: Neurological examination showed that no patient met the clinical criteria of Fragile X Tremor and Ataxia Syndrome yet. Nonetheless, premutation carriers showed some subtle neurological signs of the disorder. In fact, premutation carriers showed a significant increase of tremor (CRST, T-test p=0.007) and increase of ataxia (ICARS, p=0.004) when compared to controls. The neuropsychological evaluation was normal in both groups. To obtain general characterizations of myelination for each subject and premutation carriers, we first computed the distribution of MTR values across the total white matter volume and averaged for each group. We tested the equality of the two distributions with the non parametric Kolmogorov-Smirnov test and we rejected the null-hypothesis at a p=0.03 (fig. 2). As expected, when comparing the asymptomatic permutation carriers with control subjects, the peak value and peak position of the MTR values within the whole WM were decreased and the width of the distribution curve was increased (p<0.01). These three changes point to an alteration of the global myelin status of the premutation carriers. Subsequently, to analyze the regional myelination and white matter integrity of the same group, we performed a ROI analysis of MTR data. The ROI-based analysis showed a decrease of mean MTR value in premutation carriers compared to controls in bilateral orbito-frontal and inferior frontal WM, entorhinal and cingulum regions and cerebellum (Fig 3). The detection of these differences in these regions failed with other conventional MR techniques. Conclusions: These preliminary data confirm that in premutation carriers, there are indeed alterations in "normal appearing white matter" (NAWM) and these alterations are visible with the MT technique. These results indicate that MT imaging may be a relevant approach to detect both global and local alterations within NAWM in "asymptomatic" carriers of premutations in the Fragile X Mental Retardation 1 (FMR1) gene. The sensitivity of MT in the detection of these alterations might point towards a specific physiopathological mechanism linked to an underlying myelin disorder. ROI-based analyses show that the frontal, parahippocampal and cerebellar regions are already significantly affected before the onset of symptoms. A larger sample will allow us to determine the minimum CGG expansion and age associated with these subclinical white matter alterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and time efficient technique to illustrate specimens is described and demonstrated with Paleogene radiolarians. This method produces Scanning Electron Microscope (SEM) and composite focal depth Transmitted Light Microscope (TLM) images for single radiolarian specimens. We propose the use of this technique to clarify radiolarian taxonomy. This technique has distinct advantages over previously published time consuming techniques that can also require toxic materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expression of a hybrid gene formed by the promoter region of the Xenopus laevis vitellogenin gene B1 and the CAT coding region is regulated by estrogen when the gene is transfected into hormone-responsive MCF-7 cells. Furthermore, the 5' flanking region of the gene B1 alone can confer inducibility to heterologous promoters, although to a varying extent depending on the promoter used. Deletion mapping of he vitellogenin hormone-responsive sequences revealed that a 13 bp element 5'-AGTCACTGTGACC-3' at position -334 is essential for estrogen inducibility. We have shown previously that this 13 bp element is present upstream of several liver-specific estrogen-inducible genes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determining groundwater flow paths of infiltrated river water is necessary for studying biochemical processes in the riparian zone, but their characterization is complicated by strong temporal and spatial heterogeneity. We investigated to what extent repeat 3D surface electrical resistance tomography (ERT) can be used to monitor transport of a salt-tracer plume under close to natural gradient conditions. The aim is to estimate groundwater flow velocities and pathways at a site located within a riparian groundwater system adjacent to the perialpine Thur River in northeastern Switzerland. Our ERT time-lapse images provide constraints on the plume's shape, flow direction, and velocity. These images allow the movement of the plume to be followed for 35 m. Although the hydraulic gradient is only 1.43 parts per thousand, the ERT time-lapse images demonstrate that the plume's center of mass and its front propagate with velocities of 2x10(-4) m/s and 5x10(-4) m/s, respectively. These velocities are compatible with groundwater resistivity monitoring data in two observation wells 5 m from the injection well. Five additional sensors in the 5-30 m distance range did not detect the plume. Comparison of the ERT time-lapse images with a groundwater transport model and time-lapse inversions of synthetic ERT data indicate that the movement of the plume can be described for the first 6 h after injection by a uniform transport model. Subsurface heterogeneity causes a change of the plume's direction and velocity at later times. Our results demonstrate the effectiveness of using time-lapse 3D surface ERT to monitor flow pathways in a challenging perialpine environment over larger scales than is practically possible with crosshole 3D ERT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary goal of this study was to design a fluorescent E-selectin-targeted iodine-containing liposome for specific E-selectin imaging with the use of micro-CT. The secondary goal was to correlate the results of micro-CT imaging with other imaging techniques with cellular resolution, i.e., confocal and intravital microscopy. E-selectin-targeted liposomes were tested on endothelial cells in culture and in vivo in HT-29 tumor-bearing mice (n = 12). The liposomes contained iodine (as micro-CT contrast medium) and fluorophore (as optical contrast medium) for confocal and intravital microscopy. Optical imaging methods were used to confirm at the cellular level, the observations made with micro-CT. An ischemia-reperfusion model was used to trigger neovessel formation for intravital imaging. The E-selectin-targeted liposomes were avidly taken up by activated endothelial cells, whereas nontargeted liposomes were not. Direct binding of the E-selectin-targeted liposomes was proved by intravital microscopy, where bright spots clearly appeared on the activated vessels. Micro-CT imaging also demonstrated accumulation of the targeted lipsomes into subcutaneous tumor by an increase of 32 +/- 8 HU. Hence, internalization by activated endothelial cells was rapid and mediated by E-selectin. We conclude that micro-CT associated with specific molecular contrast agent is able to detect specific molecular markers on activated vessel walls in vivo.