948 resultados para Method of quantification


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nuclear (p,alpha) reactions destroying the so-called ""light-elements"" lithium, beryllium and boron have been largely studied in the past mainly because their role in understanding some astrophysical phenomena, i.e. mixing-phenomena occurring in young F-G stars [1]. Such mechanisms transport the surface material down to the region close to the nuclear destruction zone, where typical temperatures of the order of similar to 10(6) K are reached. The corresponding Gamow energy E(0)=1.22 (Z(x)(2)Z(X)(2)T(6)(2))(1/3) [2] is about similar to 10 keV if one considers the ""boron-case"" and replaces in the previous formula Z(x) = 1, Z(X) = 5 and T(6) = 5. Direct measurements of the two (11)B(p,alpha(0))(8)Be and (10)B(p,alpha)(7)Be reactions in correspondence of this energy region are difficult to perform mainly because the combined effects of Coulomb barrier penetrability and electron screening [3]. The indirect method of the Trojan Horse (THM) [4-6] allows one to extract the two-body reaction cross section of interest for astrophysics without the extrapolation-procedures. Due to the THM formalism, the extracted indirect data have to be normalized to the available direct ones at higher energies thus implying that the method is a complementary tool in solving some still open questions for both nuclear and astrophysical issues [7-12].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the multi-elemental determination of metals (Al, Ba, Ca, Cu, Fe, K, Mg, Mn, Sr and Zn), metalloids (B and Si), and non-metals (Cl, P and 5) in the babassu nut and mesocarp, sapucaia nut, coconut pulp, cupuassu pulp and seed, and cashew nut by axially viewed inductively coupled plasma optical emission spectrometry is presented. A diluted oxidant mixture (2 ml HNO(3) + 1 ml H(2)O(2) + 3 ml H(2)O) was used to achieve the complete decomposition of the organic matrix in a closed-vessel microwave oven. The accuracy of the entire proposed method was confirmed by standard reference material analysis (peach leaves-NIST SRM1547). The certified values showed a good agreement at a 95% confidence limit (Student`s t-test). The average RSD for repeatability of calibration solutions measurements were in the range of 1.1-6.7%. Limits of quantification (LOQ = 10 x LOD) were in the level of 0.00072-0.0532 mg/l. The macro and micronutrient ranges in the different nuts and seeds did not exceed the dietary reference intake (DRI), except for Mn in the babassu nut. (C) 2010 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article, a novel polydimethylsiloxane/activated carbon (PDMS-ACB) material is proposed as a new polymeric phase for stir bar sorptive extraction (SBSE). The PDMS-ACB stir bar, assembled using a simple Teflon (R)/glass capillary mold, demonstrated remarkable stability and resistance to organic solvents for more than 150 extractions. The SBSE bar has a diameter of 2.36 mm and a length of 2.2 cm and is prepared to contain 92 mu L of polymer coating. This new PDMS-ACB bar was evaluated for its ability to determine the quantity of pesticides in sugarcane juice samples by performing liquid desorption (LD) in 200 mu L of ethyl acetate and analyzing the solvent through gas chromatography coupled with mass spectrometry (GC-MS). A fractional factorial design was used to evaluate the main parameters involved in the extraction procedure. Then, a central composite design with a star configuration was used to optimize the significant extraction parameters. The method used demonstrated a limit of quantification (LOQ) of 0.5-40 mu g/L, depending on the analyte detected; the amount of recovery varied from 0.18 to 49.50%, and the intraday precision ranged from 0.072 to 8.40%. The method was used in the analysis of real sugarcane juice samples commercially available in local markets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R-2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL(-1), when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement-of fluoxetine in typical and trace concentration levels. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the many existing crosslinking procedures, glutaraldehyde (GA) is still the method of choice used in the manufacture of bioprosthesis. The major problems with GA are: (a) uncontrolled reactivity due to the chemical complexity or GA solutions; (b) toxicity due to the release of GA from polymeric crosslinks; and (c) tissue impermeabilization due to polymeric and heterogeneous crosslinks formation, partially responsible for the undesirable calcification of the bioprosthesis. A new method of crosslinking glutaraldehyde acetals has been developed with GA in acid ethanolic solution, and after the distribution inside de matrix, GA is released to crosslinking. Concentrations of hydrochloride acid in ethanolic solutions between 0.1 and 0.001 mol/L with GA concentration between 0.1 and 1.0% were measured in an ultraviolet spectrophotometer to verify the presence of free aldehyde groups and polymeric compounds of GA. After these measurements, the solutions were used to crosslink bovine pericardium. The spectrophotometric results showed that GA was better protected in acetal forms for acid ethanolic solution with HCl at 0.003 mol/L and GA 1.0%(v/v). The shrinkage temperature results of bovine pericardium crosslinked with acetal solutions showed values near 85 C after the exposure to triethylamine vapors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the simultaneous determination of major and minor volatiles composition in different types (dry, medium dry, sweet and medium sweet) of a young Tinta Negra Mole (TNM) monovarietal red wine from 2003 harvest has been validated. Wine samples preparation includes a dichloromethane liquid–liquid extraction followed by concentration under a nitrogen atmosphere. The extracted fraction was analysed by gas chromatography–mass spectrometry and give quantitative information for more than 86 analytes whose concentration range from few μg l−1 to 259.1 mg l−1. The method enables high recovery of volatile compounds in wine good linearity with (r2) values higher than 0.980 and good sensitivity. The limits of detection range from 0.003 to 0.534 mg l−1 and limits of quantification from 0.009 to 1.170 mg l−1. The method allows satisfactory determination of more than 80 compounds in the TNM red wines. These wines are characterized by a high content of higher alcohols, ethyl esters, fatty acids and lactones. The levels of sulphur compounds in Tinta Negra Mole medium sweet wines are very low, but they have the highest concentration of carbonyl compounds. Quantitative analysis of the main odorants followed by the determination of aroma index allow us elucidate the aroma of these varieties. On the basis of their odour description and odour threshold, the most powerful odorants of Tinta Negra Mole wines were tentatively established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tomato (Lycopersicon esculentum L.) is one of the main constituents of the Mediterranean diet. Its consumption has been proposed to reduce the risk of cardiovascular diseases and certain types of cancer. It is therefore one of the most popular and extensively consumed vegetable crop worldwide. To gain insights on the potential of Lycopersicon esculentum L. as bioactive food, two analytical methodologies were developed to determine the levels of the lipophilic -tocopherol, α-tocopherol, β-carotene, lycopene; and hydrophilic antioxidants ascorbic acid. The quantification of total carotenoids (β-carotene and lycopene) was assessed through a liquid–liquid ultrasound assisted extraction (LL-USAE) in combination with ultraviolet-visible spectroscopy (UV-Vis), according to method of mean, for total carotenoids (λmáx = 450 nm. The ultra-high performance liquid chromatographic using both photodiode array and fluorescence detection (UHPLC-PDA/FLR), allows the identification and quantification of the target lipophilic and hydrophilic antioxidants. This methodology UHPLC-PDA/FLR is fast, simple and revealed a high sensitivity for the compounds under study. The limits of detection (LODs) and quantification (LOQs) obtained were much lower (about 10 times) than the reported in literature. The method LL-USAE/UV-Vis was validated and applied to different tomato foodstuffs. The results reveal a small increase of carotenoids content during maturation, reaching the maximum level when ripe. These results complement those obtained by the ORAC and TBARS assays that show an increase of antioxidant capacity during maturation. The LODs ans LOQs obtained were also about 10 times lower than reported in literature. The carotenoid content was also evaluated by LL-USAE/UV-Vis in different tomatoes varieties. Regional variety present the high carotenoid level, followed by campari and gordal, and at last grape. This methodology was also applied to different processed food samples containing tomatoes derivatives. Highest carotenoids content were obtained in concentrated tomato foodstuffs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Genes on the X chromosome are known to be responsible for more than 200 hereditary diseases. After IVF, the simple selection of embryo sex before uterine transfer can prevent the occurrence of affected offspring among couples at risk for these genetic disorders. The aim of this investigation was to develop a rapid method of preimplantation genetic diagnosis (PGD) using real-time polymerase chain reaction (PCR) for the sexing of human embryos, and to compare it to the fluorescence in-situ hybridization technique, considered to be the gold standard. After biopsies were obtained from 40 surplus non-viable embryos for transfer, a total of 98 blastomeres were analysed. It was possible to analyse 24 embryos (60%) by both techniques, generating a total of 70 blastomeres (35 per technique), white 28 blastomeres from 16 embryos (40%) were analysed only by real-time PCR. A rapid and safe method was developed in the present study for the sexual diagnosis of a single human cell (blastomere and buccal cell) using the emerging technology of real-time PCR. (C) 2009, Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the preparation of acid carboxymethylcellulose (CMCH), and the results of a study on the adsorption and preconcentration (using batch and flow-through column methods) of Cd(II), Cu(II), Cr(III), Fe(III), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities for each metallic ion were (in mmol g(-1)) Cd(II) = 0.92; Cu(II) = 1.45; Cr(III) = 1.70; Fe(III) = 1.60; Ni(II) = 1.30; and Zn(II) = 1.10. By means of the flow-through method, a recovery of ca. 100% of the metallic ions adsorbed in a column packed with 2 g of CMCH was found when 5.0 mL of 1.0 mol L-1 hydrochloric acid were used as eluent. An enrichment factor of 20 (100 mt solution containing 50 mu g L-1 of the metallic ions, concentrated to 5.0 mt) was obtained by this preconcentration procedure. The sorption-desorption procedure applied allowed the development of a preconcentration and Flame AAS quantification method of metallic ions in fuel ethanol at trace levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several factors render carotenoid determination inherently difficult. Thus, in spite of advances in analytical instrumentation, discrepancies in quantitative results on carotenoids can be encountered in the international literature. A good part of the errors comes from the pre-chromatographic steps such as sampling scheme that does not yield samples representative of the food lots under investigation; sample preparation which does not maintain representativity and guarantee homogeneity of the analytical sample; incomplete extraction; physical losses of carotenoids during the various steps, especially during partition or washing and by adsorption to glass walls of containers; isomerization and oxidation of carotenoids during analysis. on the otherhand, although currently considered the method of choice for carotenoids, high performance liquid chromatography (HPLC) is subject to various sources of errors, such as: incompatibility of the injection solvent and the mobile phase, resulting in distorted or split peaks; erroneous identification; unavailability, impurity and instability of carotenoid standards; quantification of highly overlapping peaks; low recovery from the HPLC column; errors in the preparation of standard solutions and in the calibration procedure; calculation errors. Illustrations of the possible errors in the quantification of carotenoids by HPLC are presented.