919 resultados para Mandibular advancement device
Resumo:
Objective: The objective of the study was to analyze 2-flap designs for surgical extraction of third molar, evaluating the periodontal status of the second lower molar.Study Design: Forty-five lower third molars were extracted from 24 patients. In 23 teeth, a vertical incision to the mandibular ramus was used (technique A), whereas 22 teeth were submitted to classic L-shaped flap (technique B) with controls at 60 and 90 days postoperatively.Results: Pearson correlation coefficient analysis showed a significant correlation only between immediate preoperative probing depth variables from techniques A and B in the studied surfaces. Statistical significances in the preoperative (vestibular) and postoperative day 60 (distovestibular and vestibular) were noted. In contrast, Student t-test showed no statistical difference in probing depths between preoperative and postoperative values, as well as no statistically significant difference regarding the type of incision alone.Conclusions: Technique A allowed a less traumatic surgery, guaranteeing a more comfortable postoperative period.
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.
Resumo:
The purpose of this study was to quantify cephalometric and three-dimensional alterations of the posterior airway space of patients who underwent maxillomandibular advancement surgery. 20 patients treated by maxillomandibular advancement were selected. The minimal postoperative period was 6 months. The treated patients underwent cone-beam computed tomography at 3 distinct time intervals, preoperative (T1), immediate postoperative period up to 15 days after surgery (T2), and late postoperative period at least 6 months after surgery. The results showed that the maxillomandibular advancement promoted an increase in the posterior airway space in each patient in all the analyses performed, with a statistically significant difference between T2 and T1, and between T3 and T1, p < 0.05. There was a statistical difference between T2 and T3 in the analysis of area and volume, which means that the airway space became narrower after 6 months compared with the immediate postoperative period. The maxillomandibular advancement procedure allowed great linear area and volume increase in posterior airway space in the immediate and late postoperative periods, but there was partial loss of the increased space after 6 months. The linear analysis of airway space has limited results when compared with analysis of area and volume.
Resumo:
The present study aimed at reporting a clinical and surgical case of bilateral coronoidectomy, using an intraoral approach. The patient is a 26-year-old man, who sought attendance complaining of a gradual reduction of his oral opening in the past 3 years; however, he had an aggravation in the last 2 months. After clinical examination and imaging evaluation, the diagnosis of coronoid process hyperplasia was confirmed, and the surgical treatment was proposed. Under general anesthesia, with nasotracheal intubation guided by a nasofiberendoscope, using an intraoral approach, the bilateral coronoidectomy was performed. In the immediate postoperative period, an increase of the buccal opening measured 29 mm, representing an enhancement of 11 mm, and in the 30th postoperative day, it measured 31.12 mm. During the clinical follow-up period, a reestablishment of the mandibular movements was observed. Therefore, coronoidectomy by an intraoral approach and the physiotherapy performed in the postoperative period were efficient procedures.
Resumo:
This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.
Resumo:
The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.
Resumo:
The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.
Resumo:
Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)
Resumo:
Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.
Resumo:
The results show that, in both groups, the mandibular premolars and molars had enhanced angulation in the mesial direction, when compared with a control group of 42 Caucasians ranging in age from 12 to 17 years with a 'normal' occlusion (P < 0.05), while the mesiodistal axial angulation of the mandibular canines was similar to the control group (P < 0.05). The two groups, when compared, exhibited similar angular values for the canines, premolars and mandibular molars (P < 0.05), indicating no influence of the third molars.
Resumo:
Neste artigo é descrito o caso clínico de um paciente adulto, sem crescimento, com má oclusão de Classe II, divisão 2, tratado com um splint maxilar modificado. Foi exercida força extra-bucal com direção de tração parietal com força de 400 gramas, com uso diário de 14 horas durante 1 ano. Com este aparelho removível corrigiu-se completamente a relação de Classe II dos molares e pré-molares, levando estes dentes à oclusão normal, não havendo extrusão dentária, mantendo constante o plano mandibular. Após a correção dos dentes posteriores com o splint maxilar modificado, utilizou-se aparelhagem fixa convencional para corrigir as inclinações dos dentes anteriores e finalizar o caso.
Resumo:
OBJETIVO: relatar o tratamento de uma paciente com apinhamento severo decorrente de uma atresia maxilomandibular, tratada por meio da Distração Osteogênica da Sínfise Mandibular (DOSM). RESULTADOS: neste caso, observamos bom engrenamento dentário, diminuição do corredor bucal escuro, correção do apinhamento, boa forma de arcos e boa estética facial, num período de tempo bastante satisfatório, sem trazer dano ao tecido periodontal adjacente. CONCLUSÃO: pacientes com arcos atrésicos e apinhamento dentário podem ser beneficiados com a DOSM que, quando bem indicada, surge como uma nova forma de tratamento para casos limítrofes de apinhamento dentário, nos quais as alternativas convencionais oferecem limitações, tais como o achatamento do perfil facial, o aumento do corredor bucal e a instabilidade.
Resumo:
INTRODUÇÃO: o problema transversal em Ortodontia pode ser de origem dentária, esquelética ou uma combinação de ambas e pode ser tratado de várias maneiras de acordo com o tipo de tecido envolvido e o arco dentário acometido. em se tratando de um problema esquelético e maxilar, o ortodontista poderá lançar mão da disjunção ortopédica, dependendo da idade óssea, obtendo uma correção da atresia, um alinhamento dentário espontâneo resultante do aumento no perímetro do arco e um sorriso mais amplo, beneficiando esteticamente o paciente. Porém, este tratamento de disjunção mandibular se torna inviável, já que este osso tem sua sutura fusionada precocemente. A expansão neste caso é alveolar e sua estabilidade é questionada. OBJETIVO: relatar um caso clínico, apresentando uma nova alternativa de tratamento para o apinhamento inferior: a Distração Osteogênica da Sínfise Mandibular (DOSM). Neste procedimento, é feita uma osteotomia sagital na sínfise, criando-se uma sutura artificial para que uma separação óssea seja conseguida, utilizando uma mecânica com aparelho disjuntor de Hyrax modificado. RESULTADOS: os resultados do tratamento apresentado mostram uma melhora na forma do arco, diminuição do corredor bucal, correção do apinhamento dentário e também uma estabilidade do tratamento, sem dano aos tecidos adjacentes. Neste caso clínico, a DOSM se mostrou uma excelente opção de tratamento.
Resumo:
Purpose: the purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the mandibles of Cebus apella monkeys and filled with autogenous bone, PerioGlas, FillerBone, or Bone Source. Materials and Methods: Surgical cavities 5 mm in diameter were prepared through both mandibular cortices in the mandibular angle region. The cavities were randomly filled, and the animals were divided into groups according to the material employed: Group 1 cavities were filled with autogenous corticocancellous bone; group 2 cavities were filled with calcium phosphate cement (BoneSource); and group 3 and group 4 cavities were filled with bioactive glass (FillerBone and PerioGlas, respectively). After 180 days the animals were sacrificed, and specimens were prepared following routine laboratory procedures for hematoxylin/eosin staining and histologic evaluation. Results: the histologic analysis showed that autogenous bone allowed total repair of the bone defects; bioactive glasses (FillerBone and PerioGlas) allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; and the cavities filled with calcium phosphate cement (BoneSource) were generally filled by connective fibrous tissue, and the material was almost totally resorbed. Discussion: the autogenous bone, FillerBone, and PerioGlas provided results similar to those in the current literature, showing that autogenous bone is the best Choice for filling critical-size defects. Synthetic implanted materials demonstrated biocompatibility, but the bioglasses demonstrated osteoconductive activity that did not occur with calcium phosphate (BoneSource). Conclusion: According to the methodology used in this study, it can be concluded that the utilization of autogenous bone and bioactive glasses permitted the repair of surgically created critical-size defects by newly formed bone; the synthetic implanted materials demonstrated biocompatibility, and the bioactive glasses demonstrated osteoconductive activity. The PerioGlas was mostly resorbed and replaced by bone and the remaining granules were in close contact with bone; the FillerBone showed many granules in contact with the newly formed bone; BoneSource did not permit repair of the critical-size defects, and the defects were generally filled by connective fibrous tissue.
Resumo:
Objective. Pixel intensity values (PI) and fractal dimensions (FD) were compared in selected mandibular regions on digital panoramic images of normal, osteopenic, and osteoporotic perimenopausal and postmenopausal women to evaluate their relative efficacies in detecting osteoporotic-associated bone density changes.Study design. Standardized mandibular angle, body, and canine/premolar (C/PM) regions on 54 charge-coupied device (CCD) digital panoramic images of normal and potentially osteoporotic postmenopausal women were analyzed for PI and FD. Lumbar spine and femoral neck dual-energy x-ray absorptiometry QXA) on each patient served as the reference standard examination. Pearson correlation coefficients and analysis of variance (ANOVA) were performed.Results. There was significant correlation among PI measurements (P < 0.01), and no significant correlation between FD. C/PM had significantly lower PI than control C/PM (P = 0.049).Conclusions. Osteoporotic changes in mandibular C/PM cancellous bone were detected in our study population on CCD digital panoramic images by using a robust image analysis paradigm. Future automated application of such image analysis could enable widespread, cost effective screening for osteoporosis in dental settings.