952 resultados para Low cost alternatives


Relevância:

80.00% 80.00%

Publicador:

Resumo:

L'objectiu principal del projecte de fi de carrera

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest projecte és conseqüència d'un estudi sobre una empresa de cotxes de baix cost, que ens demana una aplicació per a gestionar les seves peticions de material de tallers remots, que, associats a l'empresa, reparen els seus vehicles. Per a això, s'ha utilitzat una aplicació B2B - entorn J2EE, i un model de treball MVC(Modelo View Controller) de contrastada fiabilitat.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The catering section, at present, offers the following: The Resource Centre accommodates classes in Healthy Eating. In the near future we hope to offer Cookery Classes in Healthy Eating, and low income meals: teaching adults and children the importance of a healthy-balanced diet which is within a low income budget; showing them how to cook these meals; supervising groups while they cook a selection of dishes which incorporate the low cost, balanced diet Initiative Type Community Food Centres Meals on Wheels Nutrition Education and Training Programmes Location Dublin 10

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to determine the in vitro activity of propolis extract against 67 yeasts isolated from onychomycosis in patients attending at the Teaching and Research Laboratory of Clinical Analysis of the State University of Maringá. The method used was an adaptation made from the protocol approved by the National Committee for Clinical Laboratory Standards. The yeasts tested were: Candida parapsilosis 35%, C. tropicalis 23%, C. albicans 13%, and other species 29%. The propolis extract showed excellent performance regarding its antifungal activity: the concentration capable of inhibiting the all of the yeasts was 5 × 10-2 mg/ml of flavonoids and 2 × 10-2 mg/ml of flavonoids stimulated their cellular death. Trichosporon sp. were the most sensitive species, showing MIC50 and MIC90 of 1.25 × 10-2 mg/ml of flavonoids, and C. tropicalis was the most resistant, with CFM50 of 5 × 10-2 mg/ml of flavonoids and MFC90 of 10 × 10-2 mg/ml. In view of the fact that propolis is a natural, low cost, non-toxic product with proven antifungal activity, it should be considered as another option in the onychomycosis treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El projecte consisteix en el disseny i implementació d'una aplicació web utilitzant la tecnologia J2EE, que es caracteritza principalment per ser multiplataforma i tenir un cost molt reduït

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An in-house, low-cost method was developed to determine the genotypic resistance of immunodeficiency virus type 1 (HIV-1) isolates. All 179 Venezuelan isolates analysed belonged to subtype B. Primary drug resistance mutations were found in 11% of 63 treatment-naïve patients. The prevalence of resistance in isolates from 116 HIV-positive patients under antiretroviral treatment was 47% to protease inhibitors, 65% to nucleoside inhibitors and 38% to non-nucleoside inhibitors, respectively. Around 50% of patients in the study harboured viruses with highly reduced susceptibility to the three classical types of drugs after only five years from their initial diagnoses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper deals with the problem of navigation for an unmanned underwater vehicle (UUV) through image mosaicking. It represents a first step towards a real-time vision-based navigation system for a small-class low-cost UUV. We propose a navigation system composed by: (i) an image mosaicking module which provides velocity estimates; and (ii) an extended Kalman filter based on the hydrodynamic equation of motion, previously identified for this particular UUV. The obtained system is able to estimate the position and velocity of the robot. Moreover, it is able to deal with visual occlusions that usually appear when the sea bottom does not have enough visual features to solve the correspondence problem in a certain area of the trajectory

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We conducted a cross-sectional, hospital-based study between January 2006-March 2008 to estimate the resistance of Mycobacterium tuberculosis to first-line drugs in patients with tuberculosis at a Brazilian hospital. We evaluated the performance of the [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide] (MTT) microplate assay compared with the Bactec-MGIT 960™ system for mycobacteria testing. The prevalence of resistance in M. tuberculosis was 6.7%. Multidrug-resistance [resistance to rifampicin (RMP) and isoniazid (INH)], INH-resistance and streptomycin (SM)-resistance accounted for 1%, 3.8% and 3.8% of all resistance, respectively, and all isolates were susceptible to ethambutol (EM). The resistance was primary in four cases and acquired in three cases and previous treatment was associated with resistance (p = 0.0129). Among the 119 M. tuberculosis isolates, complete concordance of the results for INH and EM was observed between the MTT microplate and Bactec-MGIT 960TM methods. The observed agreement for RMP was 99% (sensitivity: 90%) and 95.8% for SM (sensitivity 90.9%), lower than those for other drugs. The MTT colourimetric method is an accurate, simple and low-cost alternative in settings with limited resources.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The microplate nitrate reductase assay (MNRA) and the rezasurin microtitre assay (REMA) were used for the susceptibility testing of 73 clinical isolates and the results were compared with those that were obtained using the Bactec 460 TB and Bactec MGIT 960 systems. The REMA and the MNRA were performed in 96-well plates. For the REMA, the concentrations of isoniazid (INH) and rifampicin (RIF) ranged from 1.0-0.01 µg/mL and 2.0-0.03 µg/mL, respectively. For the MNRA, the INH concentration was between 1.0-0.03 µg/mL and the RIF concentration was between 2.0-0.06 µg/mL. For the MNRA, the sensitivity, specificity, positive predictive value, negative predictive value and INH/RIF agreement were 100/95.6, 97.6/100, 96.8/100, 100/98 and 98.6/98.6, respectively, and for the REMA, they were 100/91.3, 90.4/100, 88.5/100, 100/96.1 and 94.5/97.2, respectively. Our data suggest that these two rapid, low-cost methods may be inexpensive, alternative assays for the rapid detection of multidrug resistant tuberculosis in low-income countries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest projecte té com a objectiu la creació d'una aplicació informàtica de gestió de baix cost per a petits tallers de reparació d'automòbils per tal que puguin gestionar els seus clients i facturar les reparacions de vehicles automòbils.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A ubiquitous assessment of swimming velocity (main metric of the performance) is essential for the coach to provide a tailored feedback to the trainee. We present a probabilistic framework for the data-driven estimation of the swimming velocity at every cycle using a low-cost wearable inertial measurement unit (IMU). The statistical validation of the method on 15 swimmers shows that an average relative error of 0.1 ± 9.6% and high correlation with the tethered reference system (rX,Y=0.91 ) is achievable. Besides, a simple tool to analyze the influence of sacrum kinematics on the performance is provided.