959 resultados para Laboratory techniques and procedures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The clinical use of platelet-rich plasma (PRP) is based on the increase in the concentration of growth factors and in the secretion of proteins which are able to maximize the healing process at the cellular level. Since PRP is an autologous biologic material, it involves a minimum risk of immune reactions and transmission of infectious and contagious diseases, and it has been widely used for the recovery of musculoskeletal lesions. Despite the great potential for applicability, the implementation of the therapeutic employment of PRP as a clinical alternative has become difficult, due to the lack of studies related to the standardization of the techniques and/or insufficient description of the adopted procedures. Therefore, it is required establish standard criteria to be followed for obtaining a PRP of high quality, as well as a larger number of studies which should establish the proper concentration of platelets for the different clinical conditions. In this context, the purpose of this review is to discuss some methodological aspects used for achieving the PRP, as well as to discuss the bioactive properties of PRP, and to point out its therapeutic use in different fields of regenerative medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of his study was to review the current scientific literature in order to discuss the surgical, prosthetics and psychological/psychosocial aspects during the treatment planning of edentulous patients, when a total fixed prosthesis or overdenture is indicated. To identify studies to take part in this review, a search was conducted for the following databases: PubMed, Dentistry and Oral Sciences Source, Journals@Ovid, SpringerLink, Wiley Online Library, Nature (NPG), Oxford Journals. It was used as descriptors: total fixed prostheses and overdentures. Inclusion criteria were: clinical articles, clinical case reports, case series, literature reviews and systematic reviews that addressed the study and comparison of total fixed prostheses and overdentures for a surgical- prosthetic planning. Exclusion criteria were: laboratory and in vitro studies and those whose first language was not English or Portuguese. Of a total of 454 articles, after an analysis according to inclusion and exclusion criteria, 76 articles were selected. During an implantsupported prosthesis rehabilitation with dental in edentulous patients, the use of alternative procedures appear to be effective when compared to more invasive surgical techniques, and thus, the amount of dental implants possible to install associated with prosthetic issues such as lip support, smile line, quantity and quality of mucosa, phonetics, etc., will allow an appropriate treatment planning to each clinical case

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concept of Education for Sustainable Development, ESD, has been introduced in a period where chemistry education is undergoing a major change, both in emphasis and methods of teaching. Studying an everyday problem, with an important socio-economic impact in the laboratory is a part of this approach. Presently, the students in many countries go to school in vehicles that run, at least partially, on biofuels; it is high time to let them test these fuels. The use of renewable fuels is not new: since 1931 the gasoline sold in Brazil contains 20 to 25 vol-% of bioethanol; this composition is being continually monitored. With ESD in mind, we have employed a constructivist approach in an undergraduate course, where UV-vis spectroscopy has been employed for the determination of the composition of two fuel blends, namely, bioethanol/water, and bioethanol/gasoline. The activities started by giving a three-part quiz. The first and second ones introduced the students to historical and practical aspects of the theme (biofuels). In the third part, we asked them to develop a UV-vis experiment for the determination of the composition of fuel blends. They have tested two approaches: (i) use of a solvatochromic dye, followed by determination of fuel composition from plots of the empirical fuel polarity versus its composition; (ii) use of an ethanol-soluble dye, followed by determination of the blend composition from a Beer's law plot; the former proved to be much more convenient. Their evaluation of the experiment was highly positive, because of the relevance of the problem; the (constructivist) approach employed, and the bright colors that the solvatochromic dye acquire in these fuel blends. Thus ESD can be fruitfully employed in order to motivate the students; make the laboratory "fun", and teach them theory (solvation). The experiments reported here can also be given to undergraduate students whose major is not chemistry (engineering, pharmacy, biology, etc.). They are low-cost and safe to be introduced at high-school level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

South American subterranean rodents (Ctenomys aff. knighti), commonly known as tuco-tucos, display nocturnal, wheel-running behavior under light-dark (LD) conditions, and free-running periods >24 h in constant darkness (DD). However, several reports in the field suggested that a substantial amount of activity occurs during daylight hours, leading us to question whether circadian entrainment in the laboratory accurately reflects behavior in natural conditions. We compared circadian patterns of locomotor activity in DD of animals previously entrained to full laboratory LD cycles (LD12:12) with those of animals that were trapped directly from the field. In both cases, activity onsets in DD immediately reflected the previous dark onset or sundown. Furthermore, freerunning periods upon release into DD were close to 24 h indicating aftereffects of prior entrainment, similarly in both conditions. No difference was detected in the phase of activity measured with and without access to a running wheel. However, when individuals were observed continuously during daylight hours in a semi-natural enclosure, they emerged above-ground on a daily basis. These day-time activities consisted of foraging and burrow maintenance, suggesting that the designation of this species as nocturnal might be inaccurate in the field. Our study of a solitary subterranean species suggests that the circadian clock is entrained similarly under field and laboratory conditions and that day-time activity expressed only in the field is required for foraging and may not be time-dictated by the circadian pacemaker.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adequate polymerization plays an important role on the longevity of the composite resin restorations. Objectives: The aim of this study was to evaluate the effect of light-curing units, curing mode techniques and storage media on sorption, solubility and biaxial flexural strength (BFS) of a composite resin. Material and Methods: Two hundred and forty specimens were made of one composite resin (Esthet-X) in a stainless steel mold (2 mm x 8 mm 0), and divided into 24 groups (n=10) established according to the 4 study factors: light-curing units: quartz tungsten halogen (QTH) lamp and light-emitting diodes (LED); energy densities: 16 J/cm(2) and 20 J/cm(2); curing modes: conventional (CM) and pulse-delay (PD); and permeants: deionized water and 75% ethanol for 28 days. Sorption and solubility tests were performed according to ISO 4049:2000 specifications. All specimens were then tested for BFS according to ASTM F394-78 specification. Data were analyzed by three-way ANOVA followed by Tukey, Kruskal-Wallis and Mann-Whitney tests (alpha=0.05). Results: In general, no significant differences were found regarding sorption, solubility or BFS means for the light-curing units and curing modes (p>0.05). Only LED unit using 16 J/cm(2) and PD using 10 s produced higher sorption and solubility values than QTH. Otherwise, using CM (16 J/cm(2)), LED produced lower values of BFS than QTH (p<0.05). 75% ethanol permeant produced higher values of sorption and solubility and lower values of BFS than water (p<0.05). Conclusion: Ethanol storage media produced more damage on composite resin than water. In general the LED and QTH curing units using 16 and 20 J/cm(2) by CM and PD curing modes produced no influence on the sorption, solubility or BFS of the tested resin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the integration of information between Digital Library of Historical Cartography and Bibliographical Database (DEDALUS), both of the University of São Paulo (USP), to guarantee open, public access by Internet to the maps in the collection and make them available to users everywhere. This digital library was designed by Historical Cartography Studies Laboratory team (LECH/USP), and provides maps images on the Web, of high resolution, as well as such information on these maps as technical-scientific data (projection, scale, coordinates), printing techniques and material support that have made their circulation and cultural consumption possible. The Digital Library of Historical Cartography is accessible not only to the historical cartography researchers, but also to students and the general public. Beyond being a source of information about maps, the Digital Library of Historical Cartography seeks to be interactive, exchanging information and seeking dialogue with different branches of knowledge

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Design parameters, process flows, electro-thermal-fluidic simulations and experimental characterizations of Micro-Electro-Mechanical-Systems (MEMS) suited for gas-chromatographic (GC) applications are presented and thoroughly described in this thesis, whose topic belongs to the research activities the Institute for Microelectronics and Microsystems (IMM)-Bologna is involved since several years, i.e. the development of micro-systems for chemical analysis, based on silicon micro-machining techniques and able to perform analysis of complex gaseous mixtures, especially in the field of environmental monitoring. In this regard, attention has been focused on the development of micro-fabricated devices to be employed in a portable mini-GC system for the analysis of aromatic Volatile Organic Compounds (VOC) like Benzene, Toluene, Ethyl-benzene and Xylene (BTEX), i.e. chemical compounds which can significantly affect environment and human health because of their demonstrated carcinogenicity (benzene) or toxicity (toluene, xylene) even at parts per billion (ppb) concentrations. The most significant results achieved through the laboratory functional characterization of the mini-GC system have been reported, together with in-field analysis results carried out in a station of the Bologna air monitoring network and compared with those provided by a commercial GC system. The development of more advanced prototypes of micro-fabricated devices specifically suited for FAST-GC have been also presented (silicon capillary columns, Ultra-Low-Power (ULP) Metal OXide (MOX) sensor, Thermal Conductivity Detector (TCD)), together with the technological processes for their fabrication. The experimentally demonstrated very high sensitivity of ULP-MOX sensors to VOCs, coupled with the extremely low power consumption, makes the developed ULP-MOX sensor the most performing metal oxide sensor reported up to now in literature, while preliminary test results proved that the developed silicon capillary columns are capable of performances comparable to those of the best fused silica capillary columns. Finally, the development and the validation of a coupled electro-thermal Finite Element Model suited for both steady-state and transient analysis of the micro-devices has been described, and subsequently implemented with a fluidic part to investigate devices behaviour in presence of a gas flowing with certain volumetric flow rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oceans are key sources and sinks in the global budgets of significant atmospheric trace gases, termed Volatile Organic Compounds (VOCs). Despite their low concentrations, these species have an important role in the atmosphere, influencing ozone photochemistry and aerosol physics. Surprisingly, little work has been done on assessing their emissions or transport mechanisms and rates between ocean and atmosphere, all of which are important when modelling the atmosphere accurately.rnA new Needle Trap Device (NTD) - GC-MS method was developed for the effective sampling and analysis of VOCs in seawater. Good repeatability (RSDs <16 %), linearity (R2 = 0.96 - 0.99) and limits of detection in the range of pM were obtained for DMS, isoprene, benzene, toluene, p-xylene, (+)-α-pinene and (-)-α-pinene. Laboratory evaluation and subsequent field application indicated that the proposed method can be used successfully in place of the more usually applied extraction techniques (P&T, SPME) to extend the suite of species typically measured in the ocean and improve detection limits. rnDuring a mesocosm CO2 enrichment study, DMS, isoprene and α-pinene were identified and quantified in seawater samples, using the above mentioned method. Based on correlations with available biological datasets, the effects of ocean acidification as well as possible ocean biological sources were investigated for all examined compounds. Future ocean's acidity was shown to decrease oceanic DMS production, possibly impact isoprene emissions but not affect the production of α-pinene. rnIn a separate activity, ocean - atmosphere interactions were simulated in a large scale wind-wave canal facility, in order to investigate the gas exchange process and its controlling mechanisms. Air-water exchange rates of 14 chemical species (of which 11 VOCs) spanning a wide range of solubility (dimensionless solubility, α = 0:4 to 5470) and diffusivity (Schmidt number in water, Scw = 594 to 1194) were obtained under various turbulent (wind speed at ten meters height, u10 = 0:8 to 15ms-1) and surfactant modulated (two different sized Triton X-100 layers) surface conditions. Reliable and reproducible total gas transfer velocities were obtained and the derived values and trends were comparable to previous investigations. Through this study, a much better and more comprehensive understanding of the gas exchange process was accomplished. The role of friction velocity, uw* and mean square slope, σs2 in defining phenomena such as waves and wave breaking, near surface turbulence, bubbles and surface films was recognized as very significant. uw* was determined as the ideal turbulent parameter while σs2 described best the related surface conditions. A combination of both uw* and σs2 variables, was found to reproduce faithfully the air-water gas exchange process. rnA Total Transfer Velocity (TTV) model provided by a compilation of 14 tracers and a combination of both uw* and σs2 parameters, is proposed for the first time. Through the proposed TTV parameterization, a new physical perspective is presented which provides an accurate TTV for any tracer within the examined solubility range. rnThe development of such a comprehensive air-sea gas exchange parameterization represents a highly useful tool for regional and global models, providing accurate total transfer velocity estimations for any tracer and any sea-surface status, simplifying the calculation process and eliminating inevitable calculation uncertainty connected with the selection or combination of different parameterizations.rnrn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.