962 resultados para Intrusion errors


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The tidal influence on groundwater hydrodynamics, salt-water intrusion and submarine groundwater discharge from coastal/estuarine aquifers is poorly quantified for systems with a mildly sloping beach, in contrast to the case where a vertical beach face is assumed. We investigated the effect of beach slope for a coastal aquifer adjacent to a low-relief estuary, where industrial waste was emplaced over the aquifer. The waste was suspected to discharge leachate towards the estuary. Field observations at various locations showed that tidally induced groundwater head fluctuations were skewed temporally. Frequency analysis suggested that the fluctuation amplitudes decreased exponentially and the phase-tags increased Linearly for the primary tidal signals as they propagated inland. Salinisation zones were observed in the bottom part of the estuary and near the beach surface. Flow and transport processes in a cross-section perpendicular to the estuary were simulated using SEAWAT-2000, which is capable of depicting density-dependent flow and multi-species transport. The simulations showed that the modelled water table fluctuations were in good agreement with the monitored data. Further simulations were conducted to gain insight into the effects of beach slope. In particular the limiting case of a vertical beach face was considered. The simulations showed that density difference and tidal forcing drive a more complex hydrodynamic pattern for the mildly sloping beach than the vertical beach, as well as a profound asymmetry in tidally induced water table fluctuations and enhanced salt-water intrusion. The simulation results also indicated that contaminant transport from the aquifer to the estuary was affected by the tide, where for the mildly sloping beach, the tide tended to intensify the vertical mass exchange in the vicinity of the shorelines, (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Xanthine phosphoribosyltransferase (XPRT; EC 2.4.2.22) from Escherichia coil is a tetrameric enzyme having 152 residues per subunit. XPRT catalyzes the transfer of the phosphoribosyl group from 5-phospho-alpha-D-ribosyl l-pyrophosphate (PRib-PP) to the 6-oxopurine bases guanine, xanthine, and hypoxanthine to form GMP, XMP, and IMP, respectively. Crystals grown in the absence of substrate or product were used to determine the structure of XPRT at a resolution of 1.8 Angstrom by multiple isomorphous replacement. The core structure of XPRT includes a five-stranded parallel B-sheet surrounded by three or-helices, which is similar to that observed in other known phosphoribosyltransferase (PRTase) structures. The XPRT structure also has several interesting features. A glutamine residue in the purine binding site may be responsible for the altered 6-oxopurine base specificity seen in this enzyme compared to other 6-oxopurine PRTases. Also, we observe both a magnesium ion and a sulfate ion bound at the PRib-PP binding site of XPRT. The sulfate ion interacts with Arg-37 which has a cis-peptide conformation, and the magnesium ion interacts with Asp-89, a highly conserved acidic residue in the PRib-PP binding site motif. The XPRT structure also incorporates a feature which has not been observed in other PRTase structures. The C-terminal 12 residues of XPRT adopt an unusual extended conformation and make interactions with a neighboring subunit. The very last residue, Arg-152, could form part of the active site of a symmetry-related subunit in the XPRT tetramer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robust semi-implicit central partial difference algorithm for the numerical solution of coupled stochastic parabolic partial differential equations (PDEs) is described. This can be used for calculating correlation functions of systems of interacting stochastic fields. Such field equations can arise in the description of Hamiltonian and open systems in the physics of nonlinear processes, and may include multiplicative noise sources. The algorithm can be used for studying the properties of nonlinear quantum or classical field theories. The general approach is outlined and applied to a specific example, namely the quantum statistical fluctuations of ultra-short optical pulses in chi((2)) parametric waveguides. This example uses a non-diagonal coherent state representation, and correctly predicts the sub-shot noise level spectral fluctuations observed in homodyne detection measurements. It is expected that the methods used wilt be applicable for higher-order correlation functions and other physical problems as well. A stochastic differencing technique for reducing sampling errors is also introduced. This involves solving nonlinear stochastic parabolic PDEs in combination with a reference process, which uses the Wigner representation in the example presented here. A computer implementation on MIMD parallel architectures is discussed. (C) 1997 Academic Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Speech disorder in monolingual Cantonese- or English-speaking children has been well described in the literature. There appear to be no reports, however, that describe speech-disordered children who have been exposed to both languages. Here we report on the error patterns of two preschool speech-disordered children who were learning two languages. Both children's first language was Cantonese, but they were also exposed to English through the media and child care. Their disorders were of unknown aetiology. The following questions were asked of the data: (a) Do bilingual children, suspected of having speech problems, make errors in Cantonese and English that reflect delay or disorder when compared with normative data on monolingual speech development in each language? (b) How does the children's speech differ from other bilingual children from the same language learning background? (c) Are the children's speech difficulties apparent in both languages? (d) Is the pattern of errors the same in both languages or do language-specific processes operate? The results bear on theories of acquisition, disorder and bilingualism; they also have clinical implications for speech-language pathologists whose caseloads include bilingual preschool children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose two quantum error-correction schemes which increase the maximum storage time for qubits in a system of cold-trapped ions, using a minimal number of ancillary qubits. Both schemes consider only the errors introduced by the decoherence due to spontaneous emission from the upper levels of the ions. Continuous monitoring of the ion fluorescence is used in conjunction with selective coherent feedback to eliminate these errors immediately following spontaneous emission events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Age-related changes and the effects of dementia of the Alzheimer type (DAT) were investigated during a visual orienting attention task in which attention was pre-cued to one or other hemifields. Central cues were either valid, neutral, invalid or NoGo (inhibitory). The response time cost-benefit analysis showed a decreased benefit after valid cueing in the old compared with the young group with no change in the cost of invalid cueing. The older group were also slower over all cue types. These results suggest there is an age-related reduced ability to covertly orient attention in a visual hemifield before target onset. In contrast, the DAT group showed an increased response time benefit and showed a trend for a decreased cost in response time compared with controls. This was due to slowest response times after neutral cues. They also made significantly more response errors particularly following neutral cueing, and were less able to inhibit responses on NoGo trials than controls. The increased benefit and reduced cost found in the DAT group was interpreted as an impairment in dividing attention between left and right target locations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mitochondrial DNA (mtDNA) population data for forensic purposes are still scarce for some populations, which may limit the evaluation of forensic evidence especially when the rarity of a haplotype needs to be determined in a database search. In order to improve the collection of mtDNA lineages from the Iberian and South American subcontinents, we here report the results of a collaborative study involving nine laboratories from the Spanish and Portuguese Speaking Working Group of the International Society for Forensic Genetics (GHEP-ISFG) and EMPOP. The individual laboratories contributed population data that were generated throughout the past 10 years, but in the majority of cases have not been made available to the scientific community. A total of 1019 haplotypes from Iberia (Basque Country, 2 general Spanish populations, 2 North and 1 Central Portugal populations), and Latin America (3 populations from Sao Paulo) were collected, reviewed and harmonized according to defined EMPOP criteria. The majority of data ambiguities that were found during the reviewing process (41 in total) were transcription errors confirming that the documentation process is still the most error-prone stage in reporting mtDNA population data, especially when performed manually. This GHEP-EMPOP collaboration has significantly improved the quality of the individual mtDNA datasets and adds mtDNA population data as valuable resource to the EMPOP database (www.empop.org). (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Acrylic cement has been used for years on orthopaedic surgeries, especially on knee arthroplasties, deserving special attention when added to antibiotics (for treatment of deep bone infections) or stains (to facilitate its removal). The present study was conducted in order to evaluate potential mechanical differences between the orthopaedic cement itself and when this is added to antibiotic and/or stains. Methods: Surgical bone cement Simplex@P Stryker, vancomycin and methylene blue were used, and the mixtures were submitted to physical and mechanical tests according the ABNT NBR ISO 5833 rule. The parameters studied here were: time for mass formation, intrusion capability, resistance to compression, resistance to flexion and maximum temperature reached by the mixtures. Results: The evaluated mixtures were approved as to mass formation, maximum temperature, intrusion capability and resistance to compression. Only the one containing pure cement was approved on the flexion essay. Conclusion: The addition of vancomycin and/or methylene blue to Surgical Simplex@P Stryker bone cement reduces its resistance to flexion, being unacceptable by the ABNT NBR ISO 5833 rule.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Biochemical analysis of fluid is the primary laboratory approach hi pleural effusion diagnosis. Standardization of the steps between collection and laboratorial analyses are fundamental to maintain the quality of the results. We evaluated the influence of temperature and storage time on sample stability. Methods: Pleural fluid from 30 patients was submitted to analyses of proteins, albumin, lactic dehydrogenase (LDH), cholesterol, triglycerides, and glucose. Aliquots were stored at 21 degrees, 4 degrees, and-20 degrees C, and concentrations were determined after 1, 2, 3, 4, 7, and 14 days. LDH isoenzymes were quantified in 7 random samples. Results: Due to the instability of isoenzymes 4 and 5, a decrease in LDH was observed in the first 24 h in samples maintained at -20 degrees C and after 2 days when maintained at 4 degrees C. Aside from glucose, all parameters were stable for up to at least day 4 when stored at room temperature or 4 degrees C. Conclusions: Temperature and storage time are potential preanalytical errors in pleural fluid analyses, mainly if we consider the instability of glucose and LDH. The ideal procedure is to execute all the tests immediately after collection. However, most of the tests can be done in refrigerated sample;, excepting LDH analysis. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Neuropsychological deficits are often described in patients with bipolar disorder (BID). Some symptoms and/or associated characteristics of BD can be more closely associated to those cognitive impairments. We aimed to explore cognitive neuropsychological characteristics of type I bipolar patients (BPI) in terms Of lifetime Suicide attempt history. Method: We studied 39 BPI Outpatients compared with 53 healthy controls (HC) matched by age, educational and intellectual level. All Subjects were submitted to a neuropsychological assessment of executive functions, decision-making and declarative episodic memory. Results: When comparing BD1 patients, regardless of suicide attempt history or HC, we observed that bipolar patients performed worse than controls oil measures of memory, attention, executive functions and decision-making, Patients with a history of suicide attempt performed worse than non-attempters on measures of decision-making and there were a significant negative correlation between the number of suicide attempts and decision-making results (block 3 and net score). We also found significant Positive correlation between the number Of Suicide attempts and amount Of errors in Stroop Color Word Test (part 3). Limitations: The sample Studied call be considered small and a potentially confounding variable - medication status - were not controlled. Conclusion: Our results show the presence of neuropsychological deficits in memory, executive functions, attention and decision-making in BPI patients. Suicide attempts BPI scored worse than non-suicide attempt Bill oil measures of decision-making. More suicide attempts were associated with a worse decision-making process. Future research should explore the relationship between the association between this specific cognitive deficits in BPIs, serotonergic function and suicide behavior in bipolar patients as well other diagnostic groups. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autopsy is a valuable tool in evaluating diagnostic accuracy. Solid malignancies may have a protracted presentation, and diagnosis frequently requires imaging and deep-sited biopsies; clinical and postmortem diagnosis discrepancies may occur in a high rate in these diseases. Here, we analyzed the occurrence of clinico-pathological discrepancies in the diagnoses of solid malignancies in a Brazilian academic hospital. We reviewed charts and autopsy reports of the patients that died from 2001 to 2003 with at least one solid neoplasm. Patients were classified in concordant and discordant cases regarding cancer diagnosis. Discordant cases were categorized in undiagnosed cases (no suspicion of cancer) and in misdiagnosed cases (clinical suspicion of cancer but incompletely diagnosed). Among the 264 patients with a single non-incidental solid neoplasm, the clinico-pathological discrepancy rate was 37.1%. Liver (22.5%), lung (19.4%), and pancreatic cancer (15.3%) were the most frequent malignancies in the discordant group. Misdiagnosis category comprised 68% of the discordant cases, i.e., there was no correct knowledge about the tumor primary site and/or the histological type during life. Our data show that a high rate of discrepancies occurs in solid malignancies. Autopsies may provide the basis for a better understanding of diagnostic deficiencies in different circumstances. (C) 2008 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mexiletine (MEX), hydroxymethylmexiletine (HMM) and P-hydroxy-mexiletine (PHM) were analyzed in rat plasma by LC-MS/MS. The plasma samples were prepared by liquid-liquid extraction using methyl-tert-butyl ether as extracting solvent. MEX, HMM, and PHM enantiomers were resolved on a Chiralpak (R) AD column. Validation of the method showed a relative standard deviation (precision) and relative errors (accuracy) of less than 15% for all analytes studied. Quantification limits were 0.5 ng ml(-1) for the MEX and 0.2 ng ml(-1) for the HMM and PHM enantiomers. The validated method was successfully applied to quantify the enantiomers of MEX and its metabolites in plasma samples of rats (n = 6) treated with a single oral dose of racemic MEX. Chirality 21:648-656, 2009. (C) 2008 Wiley-Liss, Inc.