995 resultados para Implantation ionique


Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the biggest concerns in the Tissue Engineering field is the correct vascularization of engineered constructs. Strategies involving the use of endothelial cells are promising but adequate cell sourcing and neo-vessels stability are enduring challenges. In this work, we propose the hypoxic pre-conditioning of the stromal vascular fraction (SVF) of human adipose tissue to obtain highly angiogenic cell sheets (CS). For that, SVF was isolated after enzymatic dissociation of adipose tissue and cultured until CS formation in normoxic (pO2=21%) and hypoxic (pO2=5%) conditions for 5 and 8 days, in basal medium. Immunocytochemistry against CD31 and CD146 revealed the presence of highly branched capillary-like structures, which were far more complex for hypoxia. ELISA quantification showed increased VEGF and TIMP-1 secretion in hypoxia for 8 days of culture. In a Matrigel assay, the formation of capillary-like structures by endothelial cells was more prominent when cultured in conditioned medium recovered from the cultures in hypoxia. The same conditioned medium increased the migration of adipose stromal cells in a scratch assay, when compared with the medium from normoxia. Histological analysis after implantation of 8 days normoxic- and hypoxic-conditioned SVF CS in a hindlimb ischemia murine model showed improved formation of neo-blood vessels. Furthermore, Laser Doppler results demonstrated that the blood perfusion of the injured limb after 30 days was enhanced for the hypoxic CS group. Overall, these results suggest that SVF CS created under hypoxia can be used as functional vascularization units for tissue engineering and regenerative medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last few years, many reports have been describing promising biocompatible and biodegradable materials that can mimic in a certain extent the multidimensional hierarchical structure of bone, while are also capable of releasing bioactive agents or drugs in a controlled manner. Despite these great advances, new developments in the design and fabrication technologies are required to address the need to engineer suitable biomimetic materials in order tune cells functions, i.e. enhance cell-biomaterial interactions, and promote cell adhesion, proliferation, and differentiation ability. Scaffolds, hydrogels, fibres and composite materials are the most commonly used as biomimetics for bone tissue engineering. Dynamic systems such as bioreactors have also been attracting great deal of attention as it allows developing a wide range of novel in vitro strategies for the homogeneous coating of scaffolds and prosthesis with ceramics, and production of biomimetic constructs, prior its implantation in the body. Herein, it is overviewed the biomimetic strategies for bone tissue engineering, recent developments and future trends. Conventional and more recent processing methodologies are also described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hind-limb ischemia has been used in type 1 diabetic mice to evaluate treatments for peripheral arterial disease or mechanisms of vascular impairment in diabetes [1]. Vascular deficiency is not only a pathophysiological condition, but also an obvious circumstance in tissue regeneration and in tissue engineering and regenerative medicine (TERM) strategies. We performed a pilot experiment of hind-limb ischemia in streptozotocin(STZ)-induced type 1 diabetic mice to hypothesise whether diabetes influences neovascularization induced by biomaterials. The dependent variables included blood flow and markers of arteriogenesis and angiogenesis. Type 1 diabetes was induced in 8-week-old C57BL/6 mice by an i.p. injection of STZ (50 mg/kg daily for 5 days). Hind-limb ischemia was created under deep anaesthesia and the left femoral artery and vein were isolated, ligated, and excised. The contralateral hind limb served as an internal control within each mouse. Non-diabetic ischaemic mice were used as experiment controls. At the hind-limb ischemia surgical procedure, different types of biomaterials were placed in the blood vessels gap. Blood flow was estimated by Laser Doppler perfusion imager, right after surgery and then weekly. After 28 days of implantation, surrounding muscle was excised and evaluated by histological analysis for arteriogenesis and angiogenesis. The results showed that implanted biomaterials were promote faster restoration of blood flow in the ischemic limbs and improved neovascularization in the diabetic mice. Therefore, we herein demonstrate that the combined model of hind-limb ischemia in type 1 diabetes mice is suitable to evaluate the neovascularization potential of biomaterials and eventually tissue engineering constructs.  

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays cities are facing several environmental problems due to the population migration to urban areas, which is causing urban sprawl. This way, it is very important to define solutions to improve Land Use Efficiency (LUE). This article proposes the use of community buildings features as a solution to increase land use efficiency. Community buildings consider the design of shared building spaces to reduce the floor area of buildings. This work tests the performance of some case-study buildings regarding LUE to analyse its possible pros and cons. A quantifiable method is used to assess buildingsâ LUE, which considers the number of occupants, the gross floor area, the functional area, the implantation area and the allotment area. Buildings with higher values for this index have reduced environmental impacts because they use less construction materials, produce less construction and demolition wastes and require less energy for building operation. The results showed that the use of community building features can increase Land Use Efficiency of buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Biomédica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Tissue engineering: part A", vol. 21, suppl. 1 (2015)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Personalized tissue engineering and regenerative medicine (TERM) therapies propose patient-oriented effective solutions, considering individual needs. Cell-based therapies, for example, may benefit from cell sources that enable easier autologous set-ups or from recent developments on IPS cells technologies towards effective personalized therapeutics. Furthermore, the customization of scaffold materials to perfectly fit a patientâ s tissue defect through rapid prototyping technologies, also known as 3D printing, is now a reality. Nevertheless, the timing to expand cells or to obtain functional in vitrotissue substitutes prior to implantation prevents advancements towards routine use upon patient´s needs. Thus, personalized therapies also anticipate the importance of creating off-the-shelf solutions to enable immediately available tissue engineered products. This paper reviews the main recent developments and future challenges to enable personalized TERM approaches and to bring these technologies closer to clinical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To report the authors' experience with the anomalous origin of the left coronary artery (AOLCA) from the pulmonary trunk, emphasizing preoperative data, surgical aspects and midterm results of the follow-up. METHODS: Retrospective analysis of 11 patients operated upon at the Royal Brompton Hospital from October, 84 to April, 97. RESULTS: Nine infants had heart failure (HF) and two other children presented with dyspnea and chest pain. All had ECG changes. The echocardiogram identified the anomalous origin of the coronary artery in 7 (64%) patients and hemodynamic studies were performed in 7 patients. All infants were operated upon between the 2nd and 10th month of life. Six patients were treated with aortic reimplantation of the left coronary artery, whereas five were operated upon according to the Takeuchi technique. All patients are alive, with clear improvement of the ECG changes and ventricular function, as evaluated by echocardiography. Two patients operated upon according to the Takeuchi technique required additional surgery due to severe supravalvular pulmonary stenosis. CONCLUSION: AOLCA is a rare disease. Most patients show early signs of severe HF associated with ECG findings. Surgical therapy must be instituted early in the disease, preferentially through aortic implantation of the anomalous coronary artery, with a high possibility of success. Shortly after surgery, clinical and ECG improvement, as well as normalization of left ventricular function, should be expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 ± 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22mmHg). An AV delay >100ms produced a significantly lower decrease in VER depolarization duration (VER DD) when compared to an AV delay <=100ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r=0.69; p<0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - This study compared the early and late results of the use of one single stent with those of the use of multiple stents in patients with lesions longer than 20mm. METHODS - Prospective assessment of patients electively treated with stents, with optimal stent deployment and followed-up for more than 3 months. From February '94 to January '98, 215 patients with lesions >20mm were treated. These patients were divided into 2 groups as follows: Group A - 105 patients (49%) with one stent implanted; Group B - 110 patients (51%) with multiple stents implanted. RESULTS - The mean length of the lesions was 26mm in group A (21-48mm) versus 29mm in group B (21-52mm) (p=0.01). Major complications occurred in one patient (0.9%) in group A (subacute thrombosis, myocardial infarctionand death) and in 2 patients (1.8%) in group B (one emergency surgery and one myocardial infarction) (p=NS). The results of the late follow-up period (>6 months) were similar for both groups (group A = 82% vs group B = 76%; p=NS), and we observed an event-free survical in 89% of the patients in group A and in 91% of the patients in group B (p=NS). Angina (group A = 11% vs group B = 7%) and lesion revascularization (group A = 5% vs group B = 6%; p=NS) also occurred in a similar percentage. No infarction or death was observed in the late follow-up period; restenosis was identified in 33% and 29% of the patients in groups A and B, respectively (p=NS). CONCLUSION - The results obtained using one stent and using multiple stents were similar; the greater cost-effectiveness of one stent implantation, however, seems to make this strategy the first choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.