936 resultados para Implant Placement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AimTo evaluate the influence (i) of various implant platform configurations and (ii) of implant surface characteristics on peri-implant tissue dimensions in a dog model.Material and methodsMandibular premolars and first molars were extracted bilaterally in six Labrador dogs. After 3 months of healing, two implants, one with a turned and a second with a moderately rough surface, were installed on each side of the mandible in the premolar region. on the right side of the mandible, implants with a tapered and enlarged platform were used, while standard cylindrical implants were installed in the left side of the mandible. Abutments with the diameter of the cylindrical implants were used resulting in a mismatch of 0.25 mm at the tapered implant sites. The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.ResultsAll implants were completely osseointegrated. A minimal buccal bone resorption was observed for both implant configurations and surface topographies. Considering the animals as the statistical unit, no significant differences were found at the buccal aspect in relation to bone levels and soft tissue dimensions. The surface topographies did not influence the outcomes either.ConclusionsThe present study failed to show differences in peri-implant tissue dimensions when a mismatch of 0.25 mm from a tapered platform to an abutment was applied. The surface topographies influence a neither marginal bone resorption or peri-implant soft tissue dimension.To cite this article:Baffone GM, Botticelli D, Pantani F, Cardoso LC, Schweikert MT, Lang NP. Influence of various implant platform configurations on peri-implant tissue dimensions: an experimental study in dog.Clin. Oral Impl. Res. 22, 2011; 438-444.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a chemical medium for preservation of tissues, glycerin has shown good results because it maintains the cellular integrity despite the tissue dehydration it causes. Taking advantage of the osteoinducing properties of the osseous matrix and glycerin as a proper medium for tissue preservation, osseous matrix was implanted in rat tibias. Twenty-four rats were used, each receiving two surgical wounds. In one of the wounds an osseous matrix preserved in 98% glycerin was implanted and the other received a matrix without preservatives. Six animals were sacrificed on days 10, 20, 30 and 60 post-implant. After routine histological processing, the specimens were stained in hematoxylin-eosin and Masson's trichrome. The results showed that the matrixes preserved in glycerin presented faster resorption with replacement by newly formed tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent unilateral evisceration with placement of 2ml GP (GP group - 16 animals) or 2ml 0.9% sodium chloride solution (Control group - 12 animals). Animal behavior, postoperative tissue response and socket conditions were evaluated. The animals were sacrificed at 7, 15, 30 and 60 days after the surgery and the bulbs were enucleated; volume maintenance and histopathological evaluation were done in the enucleated bulbs. The results were submitted to statistical analysis. RESULTS: All animals showed normal behavior. The orbital volume maintenance was better in the GP group. Histopathology in the GP animals showed mild tissue inflammation throughout the evaluation period and a thin pseudocapsule formation surrounding the orbital implant material. CONCLUSION: The clinical findings, good orbital volume maintenance and mild inflammatory tissue response make GP a good choice to replace the lack of volume in anophthalmic socket reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This pilot study evaluated, by culture testing, the effectiveness of lethal photosensitization for the microbiological treatment of peri-implantitis in dogs. Experimental peri-implantitis was induced by ligature placement for 2 months. Following ligature removal, plaque control was instituted by scrubbing with 0.12% chlorhexidine daily for 12 months. Subsequently, mucoperiosteal flaps were elevated for scaling the implant surface. Microbial samples were obtained with paper points before and after treatment of implant surfaces by means of 100 microg/ml toluidine blue O (TBO,) and were exposed, for 80 s, to light with a wavelength of 685 nm from a 50 mW GaAlAs diode laser. The mean initial and final bacterial counts were 7.22 +/- 0.20 and 6.84 +/- 0.44 CFU/ml, respectively for TVC (P < 0.0001); 6.19 +/- 0.45 and 3.14 +/- 3.29 CFU/ml for P. intermedia/nigrescens (P = 0.001); 5.98 +/- 0.38 and 1.69 +/- 2.90 CFU/ml for Fusobacterium spp. (P = 0.001); and 6.07 +/- 0.22 to 1.69 +/- 2.94 CFU/ml for beta-hemolytic Streptococcus (P = 0.0039). It may be concluded that lethal photosensitization resulted in a reduction of the bacterial count. Complete elimination of bacteria was achieved in some samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The processing of titanium porous coatings using powder metallurgy technique to achieve a porous structure that allows osseointegration with bone tissue was discussed. The porous microstructure exhibited micropores and interconnected macropores with size ranges that allowed bone ingrowth. The macropores in the coatings were originated from the binder evaporation while the micropore was related with the porous titanium powder and the low compaction pressure used. The in vivo evaluation indicated that osseointegration had occurred between the bone and porous material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to histomorphometrically evaluate the bone-to-implant contact and bone area around a titanium implant retrieved from a human lower jaw. A screw-shaped titanium implant (sandblasted and acid-etched surface) was removed from a 68-year-old male after having been in function for 40 months because of a fracture of the abutment screw. Following the implant removal, an undecalcified section was obtained. The histomorphometric analysis showed a rate of 75.40% of bone-to-implant contact and 89.30% of bone area filling within the limits of the implant threads. The surrounding bone healed in a well-organized pattern and could not be differentiated from the anginal alveolus. The histologic evidence showed a high degree of osseointegration in a threaded, sandblasted, and acid-etched implant retrieved from a human lower jaw after functional loading for 40 months. Copyright © 2005 by Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of teeth-implant, mucosa-supported removable dentures for rehabilitation of partially edentulous patients involves highly complex biomechanical aspects. This type of prosthesis associates 3 kinds of support that react differently to the functional and parafunctional forces developed in the oral cavity. Although the construction of removable partial dentures may seem paradoxical when osseointegrated implants are placed, in some cases, this option is an excellent alternative to solve difficulties related to the anatomic, biologic, psychomotor, and financial conditions of the patient. This article reports on a case in which a teeth-implant, mucosa-supported removable partial denture was the option of choice for a patient with financial and anatomic limitations, having a large structural loss of the residual alveolar ridge caused by trauma by a gunshot injury at the mandible. The 5-year follow-up did not reveal any type of biomechanical or functional problem. Copyright © 2006 by Lippincott Williams and Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capacitor placement problem for radial distribution networks aims to determine capacitor types, sizes, locations and control scheme. This is a combinatorial problem that can be formulated as a mixed integer nonlinear program. The paper presents an algorithm inspired in artificial immune systems and developed for this specific problem. A good performance was obtained through experimental tests applied to known systems. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an expert and interactive system for developing protection system for overhead and radial distribution feeders is proposed. In this system the protective devices can be allocated through heuristic and an optimized way. In the latter one, the placement problem is modeled as a mixed integer non-linear programming, which is solved by genetic algorithm (GA). Using information stored in a database as well as a knowledge base, the computational system is able to obtain excellent conditions of selectivity and coordination for improving the feeder reliability indices. Tests for assessment of the algorithm efficiency were carried out using a real-life 660-nodes feeder. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important stage in the solution of active vibration control in flexible structures is the optimal placement of sensors and actuators. In many works, the positioning of these devices in systems governed for parameter distributed is, mainly, based, in controllability approach or criteria of performance. The positions that enhance such parameters are considered optimal. These techniques do not take in account the space variation of disturbances. An way to enhance the robustness of the control design would be to locate the actuators considering the space distribution of the worst case of disturbances. This paper is addressed to include in the formulation of problem of optimal location of sensors and piezoelectric actuators the effect of external disturbances. The paper concludes with a numerical simulation in a truss structure considering that the disturbance is applied in a known point a priori. As objective function the C norm system is used. The LQR (Linear Quadratic Regulator) controller was used to quantify performance of different sensors/actuators configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation of the patients toothless totals presents large difficulties, because diverse factors act limiting the treatment with complete dentures conventional, as severe reabsorption of the alveolar process, generating for the phonetic patient difficulties and of mastication, annoyance, retention lack and stability of the prosthesis. With the emergence of you implant them osseointegratin idealized by Prof o Branemark, these aspects were improved by means of the possibility of new treatment options, as the overdentures tissue-implant-supported. However, the protocol of Branemark demanded a period of scaring from three to six months, owing the patients to await this time for the placement of the final prosthesis. This way, the surgical technique of immediate load was proposed to abbreviate this period, improving the transition phase, at the same time that it reduces the problems psychological associates. This way, the objective of the present study is to carry out a literature revision about the works that used overdentures comparing immediate and late load, the best alternative and factors wrapped in the success of the procedure discussing. © 2008 1995, Editorial Ciencias médicas.