946 resultados para High-dose chemotherapy
Resumo:
This study sought to use a microdialysis technique to relate clinical and biochemical responses to the time course of melphalan concentrations in the subcutaneous interstitial space and in tumour tissue (melanoma, malignant fibrous histiocytoma, Merkel cell tumour and osteosarcoma) in patients undergoing regional chemotherapy by Isolated Limb Infusion (ILI). 19 patients undergoing ILI for treatment of various limb malignancies were monitored for intra-operative melphalan concentrations in plasma and, using microdialysis, in subcutaneous and tumour tissues. Peak and mean concentrations of melphalan were significantly higher in plasma than in subcutaneous or tumour microdialysate. There was no significant difference between drug peak and mean concentrations in interstitial and tumour tissue, indicating that there was no preferential uptake of melphalan into the tumours. The time course of melphalan in the microdialysate could be described by a pharmacokinetic model which assumed melphalan distributed from the plasma into the interstitial space. The model also accounted for the vascular dispersion of melphalan in the limb. Tumour response in the whole group to treatment was partial response: 53.8% (n = 7); complete response: 33.3% (n = 5); no responses 6.7% (n = 1). There was a significant association between tumour response and melphalan concentrations measured over time in subcutaneous microdialysate (P < 0.01). No significant relationship existed between the severity of toxic reactions in the limb or peak plasma creatine phosphokinase levels and peak melphalan microdialysate or plasma concentrations. It is concluded that microdialysis is a technique well suited for measuring concentrations of cytotoxic drug during ILI. The possibility of predicting actual concentrations of cytotoxic drug in the limb during ILI using our model opens an opportunity for improved drug dose calculation. The combination of predicting tissue concentrations and monitoring in microdialysate of subcutaneous tissue could help optimise ILI with regard to post-operative limb morbidity and tumour response. (C) 2001 Cancer Research Campaign http:,//www.bjcancer.com.
Resumo:
We present the comparative evaluation of school-based chemotherapy with praziquantel on Schistosoma haematobium reinfection patterns, 6, 12, 18 and 24 months after systematic treatment of schoolchildren in four villages of south-central Côte d'Ivoire. At baseline, very high S. haematobium infection prevalences of 88–94% were found in Taabo Village, located adjacent to a large man-made lake, and in Batera and Bodo, where small dams were constructed. In Assinzé, a village with no man-made environmental alterations, the baseline infection prevalence was significantly lower (67%). The parasitological cure rate, assessed 4 weeks after praziquantel administration in the village with the highest prevalence and intensity of infection, was high (82%), and showed a clear association with infection intensity prior to treatment. Six months after chemotherapy, significant reductions in the prevalence and intensity of infection were observed in all villages. However, infection prevalence was again high in Taabo Village (63%) and in Batera (49%). Different patterns of reinfection occurred in the four villages: rapid reinfection in Taabo Village to reach almost baseline infection prevalence 12 months post-treatment; slow but gradual increase in the prevalence and intensity of infection in Bodo; marked increase in prevalence and intensity of infection during the second year of the follow-up in Assinzé; and prevalence and intensity of infection that remained almost constant between 6 and 24 months post-treatment in Batera. Our study confirms that S. haematobium reinfection patterns largely depend on the local epidemiological setting, which is of central importance to tailoring treatment strategies that are well adapted to these different settings.
Resumo:
The effect of gamma-radiation on a perfluoroalkoxy (PFA) resin was examined using solid-state high-speed magic angle spinning (MAS) F-19 NMR spectroscopy. Samples were prepared for analysis by subjecting them to gamma-radiation in the dose range 0.5-3 MGy at either 303, 473, or 573 K. New structures identified include new saturated chain ends, short and long branches, and unsaturated groups. The formation of branched structures was found to increase with increasing irradiation temperature; however, at all temperatures the radiation chemical yield (G value) of new chain ends was greater than the G value of long branch points, suggesting that chain scission is the net process.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações
Resumo:
Mestrado em Radioterapia.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem Digital com Radiação X
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
Resumo:
Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
Immunosuppressed animals respond poorly to schistosomal chemotherapy and that a proper response can be restored by the administration of immune serum. Present study attempts to search whether immunological stimulation would increase drug effectiveness. Swiss mice infected with 50 S. mansoni cercariae were later treated with complete Freund's adjuvant. Treatment with oxaminiquine was made with 100 mg/kg.b.w., 25 mg/kg.b.w. and 50 mg/kg/b.w., the last two doses representing a fourth and a half of the recommended curative dose. Appropriate controls for the drug, the adjuvant and the infection were also studied. The serum-level of ant-S. mansoni antibodies (ELISA) and recovery of worms by perfusion of the portal vein system were the evaluated parameters. Statistical analysis of the results failed to reveal significant differences in worm recovery between adjuvant-stimulated animals treated with oxamniquine and any of the treated controls receiving the same amount of the drug. Although total lack of immunity interferes with curative treament the usual immune response seems to be sufficient to allow for curative drug action in schistosomiasis and thus apparently does not need to be artificially stimulated
Resumo:
In order to study the chemoresistance of Plasmodium falciparum to commonly used antimalarial drugs in Brazil the authors have studied ten patients with falciparum malaria, acquired in the Brazilian Amazon region. Patients were submitted to in vivo study of drug sensitivity, after chemotherapy with either 4-aminoquinolines (chloroquine or amodiaquine) or quinine. Adequate drug absorption was confirmed by standard urine excretion tests for antimalarials. Eight patients could be followed up to 28 days. Among these in vivo resistance (R I and R II responses) was seen in all patients who received 4-amino-quinolines. One patient treated with quinine exhibited a R III response. Peripheral blood samples of the same patients were submitted to in vitro microtests for sensitivity to antimalarials. Out of nine successful tests, resistance to chloroquine and amodiaquine was found in 100% and resistance to quinine in 11.11% of isolates. Probit analysis of log dose-response was used to determine effective concentrations EC50, EC90 and EC99 to the studied drugs. Good correlation between in vivo and in vitro results was seen in six patients. The results emphasize high levels of P. falciparum resistance to 4- aminoquinolines and suggest an increase in resistance to quinine in the Brazilian Amazon region, reinforcing the need for continuous monitoring of drug sensitivity to adequate chemotherapy according to the most efficacious drug regimens
Resumo:
A clinical trial pilot study, double-blinded, randomized, and controlled with a placebo to assess the effectiveness of oral doxycycline (200 mg, single dose) in preventing leptospirosis after high exposure to potentially contamined water was performed in São Paulo, SP, Brazil. Confirmed cases were defined as those with leptospira IgM antibody and symptoms; asymptomatic cases were those presenting with IgM antibodies but no symptoms; and suspected cases were individuals with symptoms but no IgM antibody. Forty subjects were given doxycycline and 42 were given placebo. In the drug-treated group there were 2 confirmed cases, 11 asymptomatic cases, and 6 suspected cases. In the placebo group there were 5 confirmed, 6 symptomatic, and 5 suspected cases. Even though we found a protective association of doxycycline for confirmed leptospirosis cases (RR = 2.3) and seroconversion only (RR = 2.0), the association was not statistically significant because of the small number of individuals enrolled in this pilot study. We observed that the 22% of the volunteers already had IgM antibodies to leptospirosis at the first sampling. Finally, the attack rate to confirmed, asymptomatic, and suspected cases of Leptospirosis was 8.5%, 22%, and 13%, respectively, in this population.