860 resultados para Heat Treatment - Effects


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, ceria-yttria co-stabilized zirconia (CYSZ) free-standing coatings, deposited by air plasma spraying (APS), were isothermally annealed at 1315 °C in order to explore the effect of sintering on the microstructure and the mechanical properties (i.e., hardness and Young's modulus). To this aim, coating microstructure, before and after heat treatment, was analyzed using scanning electron microscopy, and image analysis was carried out in order to estimate porosity fraction. Moreover, Vickers microindentation and depth-sensing nanoindentation tests were performed in order to study the evolution of hardness and Young's modulus as a function of annealing time. The results showed that thermal aging of CYSZ coatings leads to noticeable microstructural modifications. Indeed, the healing of finer pores, interlamellar, and intralamellar microcracks was observed. In particular, the porosity fraction decreased from ~10 to ~5% after 50 h at 1315 °C. However, the X-ray diffraction analyses revealed that high phase stability was achieved, as no phase decomposition occurred after thermal aging. In turn, both the hardness and Young's modulus increased, in particular, the increase in stiffness (with respect to "as produced" samples) was equal to ~25%, whereas the hardness increased to up to ~60%. © 2010 Springer Science+Business Media, LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The electroless nickel composite (ENC) with various silicon carbide contents was deposited onto aluminium alloy (LM24) substrate. The wear behaviour and the microhardness of the composite coating samples were investigated and compared with particles free and aluminium substrate samples using micro-scale abrasion tester and microhardness tester respectively. The wear scar marks and wear volume were analysed by optical microscope. The wear tracks were further studied using scanning electron microscopy (SEM). The embedded particles were found to get pressed into the matrix which helps resisting further wearing process for composite samples. However, random orientation of microcuts and microfallow were seen for ENC sample but more uniform wearing was observed for EN sample. The composite coating with low content of SiC was worn minimum. Early penetration into the substrate was seen for samples with higher SiC content. Microhardness was improved after heat treatment for all the samples containing various SiC content. Under dry sliding condition, inclusion of particles in the matrix did not improve the wearing resistance performance in as-deposited state. The wearing worsened as the content of the particles increased generally. However, on heat treatment, the composite coatings exhibited improved wear resistance and the best result was obtained from the one with low particle contents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Robust, bilayer heterojunction photodiodes of TiO2-WO3 were prepared successfully by a simple, low-cost powder pressing technique followed by heat-treatment. Exclusive photoirradiation of the TiO2 side of the photodiode resulted in a rapid colour change (dark blue) on the WO3 surface as a result of reduction of W6+ to W5+ (confirmed by X-ray photoelectron spectroscopy). This colour was long lived and shown to be stable in a dry environment in air for several hours. A similar photoirradiation experiment in the presence of a mask showed that charge transfer across the heterojunction occurred approximately normal to the TiO2 surface, with little smearing out of the mask image. As a result of the highly efficient vectorial charge separation, the photodiodes showed a tremendous increase in photocatalytic activity for the degradation of stearic acid, compared to wafers of the respective individual materials when tested separately.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Ivacaftor has shown a clinical benefit in patients with cystic fibrosis who have the G551D-CFTR mutation and reduced lung function. Lung clearance index (LCI) using multiple-breath washout might be an alternative to and more sensitive method than forced expiratory volume in 1 s (FEV1) to assess treatment response in the growing number of children and young adults with cystic fibrosis who have normal spirometry. The aim of the study was to assess the treatment effects of ivacaftor on LCI in patients with cystic fibrosis, a G551D-CFTR mutation, and an FEV1 >90% predicted. Methods: This phase 2, multicentre, placebo-controlled, double-blind 2×2 crossover study of ivacaftor treatment was conducted in patients with cystic fibrosis, at least one G551D-CFTR allele, and an FEV1 >90% predicted. Patients also had to have an LCI higher than 7·4 at screening, age of 6 years or older, and a weight higher than or equal to 15 kg. Eligible patients were randomly allocated to receive one of two treatment sequences (placebo first followed by ivacaftor 150 mg twice daily [sequence 1] or ivacaftor 150 mg twice daily first followed by placebo [sequence 2]) of 28 days' treatment in each period, with a 28-day washout between the two treatment periods. Randomisation (ratio 1:1) was done with block sizes of 4, and all site personnel including the investigator, the study monitor, and the Vertex study team were masked to treatment assignment. The primary outcome measure was change from baseline in LCI. The study is registered at ClinicalTrials.gov, NCT01262352. Findings: Between February and November, 2011, 21 patients were enrolled, of which 11 were assigned to the sequence 1 group, and 10 to the sequence 2 group. 20 of these patients received treatment and 17 completed the trial (eight in sequence 1 group and 9 in sequence 2 group). Treatment with ivacaftor led to significant improvements compared with placebo in LCI (difference between groups in the average of mean changes from baseline at days 15 and 29 was -2·16 [95% CI -2·88 to -1·44]; p<0·0001). Adverse events experienced by study participants were similar between treatment groups; at least one adverse event was reported by 15 (79%) of 19 patients who received placebo and 13 (72%) of 18 patients who received ivacaftor. No deaths occurred during study period. Interpretation: In patients with cystic fibrosis aged 6 years or older who have at least one G551D-CFTR allele, ivacaftor led to improvements in LCI. LCI might be a more sensitive alternative to FEV1 in detecting response to intervention in these patients with mild lung disease. Funding: Vertex Pharmaceuticals Incorporated. © 2013 Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroless nickel composite coatings with silicon carbide, SiC, as reinforcing particles deposited with Ni–P onto aluminium alloy, LM24, having zincating as under layer were subjected to heat treatment using air furnace. The changes at the interface were investigated using scanning electron microscope (SEM) and energy dispersive X-ray (EDX) to probe the chemistry changes upon heat treatment. Microhardness tester with various loads using both Knoop and Vickers indenters was used to study the load effect clubbed with the influence of second phase particles on the coating at the vicinity of the interface. It was observed that zinc was absent at the interface after elevated temperature heat treatment at 400–500 °C. Precipitation of copper and nickel with a distinct demarcation (copper rich belt) along the coating interface was seen with irregular thickness of the order of 1 μm. Migration of copper from the bulk aluminium alloy could have been the factor. Brittleness of the coating was confirmed on heat treatment when indented with Vickers. However, in composite coating the propagation of the microcrack was stopped by the embedded particles but the microcracks continue in the matrix when not interrupted by second phase particles (SiC).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroless Ni–P (EN) and composite Ni–P–SiC (ENC) coatings were developed on cast aluminium alloy substrate, LM24. The coating phase composition, microstructure and microhardness were investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM) and microhardness tester, respectively, on as-plated and heat-treated specimens. The original microstructure of the Ni–P matrix is not affected by the inclusion of the hard particles SiC. No formation of Ni–Si phase was observed up to 500 °C of heat treatment. The microhardness is increased on incorporation of SiC in Ni–P matrix. The hardening mechanism is the formation of intermetallic phase Ni3P on annealing at elevated temperature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surface behaviour is of paramount importance as failure and degradation tend to initiate from the surface. Electroless composite coating (NiP/SiC) was developed using SiC as reinforcing particles. As heat treatment plays a vital role in electroless nickel coating owing to the changes in microstructure, phase structure and mechanical properties, an insight at the interface changes in chemistry and micromechanical behaviour was investigated using scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) and microindentation techniques. Corrosion performance was analysed using electrochemical impedance spectroscopy (EIS). Absence of zinc and migration of copper at the interface was detected. Brittleness and microcracks was seen long the interface when indenting at load of 500 gf (Vickers). Corrosion performance is weaker than particles free coating. However, a thin blanket of NiP could enhance the resistance to corrosive medium.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroless Ni-P (EN) and composite Ni-P-SiC (ENC) coatings were developed on cast aluminium alloy, LM24. The coating phase composition, microstructure and microhardness were investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM) and microhardness tester, respectively, on as-plated and heat-treated specimens. The original microstructure of the Ni-P matrix is not affected by the inclusion of the hard particles SiC. No formation of Ni-Si phase was observed upto 500°C of heat treatment. The microhardness is increased on incorporation of SiC in Ni-P matrix. The hardening mechanism is the formation of intermetallic phase Ni3P on annealing at elevated temperature. Overall, the composite coating (ENC) was found to be superior as compared to particles free (EN) coating in both as-deposited and heat-treated conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroless nickel (EN) and electroless nickel composite (ENC) coatings were deposited on aluminium alloy substrate, LM24. The micro abrasion test was conducted to study the wear behaviour of the coatings with the effect of SiC concentration. Microhardness of the coatings was tested also. The wear scars were analysed using optical microscope and scanning electron microscope (SEM). The wear resistance was found to be improved in composite coating that has higher microhardness as compared to particles free and the bare aluminium substrate. In as-deposited condition for the composite coating, the wear volume increases on increase in SiC percentage in the coating but is found to be minimum for lower SiC percentage. The increase in hardness on heat treatment at 400°C is due to the hardening or grain coarsening with the formation Ni3P.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: "Cumulative meta-analysis" describes a statistical procedure to calculate, retrospectively, summary estimates from the results of similar trials every time the results of a further trial in the series had become available. In the early 1990 s, comparisons of cumulative meta-analyses of treatments for myocardial infarction with advice promulgated through medical textbooks showed that research had continued long after robust estimates of treatment effects had accumulated, and that medical textbooks had overlooked strong, existing evidence from trials. Cumulative meta-analyses have subsequently been used to assess what could have been known had new studies been informed by systematic reviews of relevant existing evidence and how waste might have been reduced.

METHODS AND FINDINGS: We used a systematic approach to identify and summarise the findings of cumulative meta-analyses of studies of the effects of clinical interventions, published from 1992 to 2012. Searches were done of PubMed, MEDLINE, EMBASE, the Cochrane Methodology Register and Science Citation Index. A total of 50 eligible reports were identified, including more than 1,500 cumulative meta-analyses. A variety of themes are illustrated with specific examples. The studies showed that initially positive results became null or negative in meta-analyses as more trials were done; that early null or negative results were over-turned; that stable results (beneficial, harmful and neutral) would have been seen had a meta-analysis been done before the new trial; and that additional trials had been much too small to resolve the remaining uncertainties.

CONCLUSIONS: This large, unique collection of cumulative meta-analyses highlights how a review of the existing evidence might have helped researchers, practitioners, patients and funders make more informed decisions and choices about new trials over decades of research. This would have led to earlier uptake of effective interventions in practice, less exposure of trial participants to less effective treatments, and reduced waste resulting from unjustified research.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste trabalho foram produzidos nanocompósitos de AlSiC misturando alumínio puro com nano partículas de SiC com diâmetro de 45 – 55 nm, usando, de forma sequencial, a técnica da metalurgia do pó e a compactação por “ Spark Plasma Sintering”. O compósito obtido apresentava grãos com 100 nm de diâmetro, encontrandose as partículas de SiC localizadas, principalmente, nas fronteiras de grão. O nanocompósito sob a forma de provetes cilíndricos foi submetido a testes de compressão uniaxial e a testes de nanoindentação para analisar a influência das nanopartículas de SiC, da fração volúmica de ácido esteárico e do tempo de moagem, nas propriedades mecânicas do material. Para efeitos de comparação, utilizouse o comportamento mecânico do Al puro processado em condições similares e da liga de alumínio AA1050O. A tensão limite de elasticidade do nanocompósito com 1% Vol./Vol. de SiC é dez vezes superior à do AA1050. O refinamento de grão à escala nano constitui o principal mecanismo de aumento de resistência mecânica. Na realidade, o Al nanocristalino sem reforço de partículas de SiC, apresenta uma tensão limite de elasticidade sete vezes superior à da liga AA1050O. A adição de 0,5 % Vol./Vol. e de 1 % Vol./Vol. de SiC conduzem, respetivamente, ao aumento da tensão limite de elasticidade em 47 % e 50%. O aumento do tempo de moagem e a adição de ácido esteárico ao pó durante a moagem conduzem apenas a um pequeno aumento da tensão de escoamento. A dureza do material medida através de testes de nanoindentação confirmaram os dados anteriores. A estabilidade das microestruturas do alumínio puro e do nanocompósito AlSiC, foi testada através de recozimento de restauração realizado às temperaturas de 150 °C e 250 °C durante 2 horas. Aparentemente, o tratamento térmico não influenciou as propriedades mecânicas dos materiais, excepto do nanocompósito com 1 % Vol./Vol. de SiC restaurado à temperatura de 250 °C, para o qual se observou uma redução da tensão limite de elasticidade na ordem dos 13 %. No alumínio nanocristalino, a tensão de escoamento é controlada pelo efeito de HallPetch. As partículas de SiC, são segregadas pelas fronteiras do grão e não contribuem para o aumento de resistência mecânica segundo o mecanismo de Orowan. Alternativamente, as nanopartículas de SiC constituem um reforço das fronteiras do grão, impedindo o seu escorregamento e estabilizando a nanoestrutura. Deste modo, as propriedades mecânicas do alumínio nanocristalino e do nanocompósito de AlSiC poderão estar relacionadas com a facilidade ou dificuldade do escorregamento das fronteiras de grão, embora não seja apresentada prova explícita deste mecanismo à temperatura ambiente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le forgeage de préformes fabriquées par métallurgie des poudres nous permet d’atteindre une densification voisine de la densité théorique ce qui a comme incidence directe une amélioration substantielle des propriétés mécaniques finales des pièces, notamment la résistance en fatigue. La démarche préconisée pour améliorer cette performance critique de pièces forgées par métallurgie des poudres consiste à optimiser leurs caractéristiques métallurgiques et leur densité concomitante. À ce propos, une nouvelle formulation d’acier MP a été développée et caractérisée. La stratégie de développement portait sur l’utilisation d’éléments de microalliage préalliés, comme le vanadium et le niobium. Pour ce faire, on a optimisé le paramètre de mise en œuvre primordial, qui est la température de forgeage, afin d’obtenir une fine taille de grains à la fin du cycle du traitement réalisé accompagnée d’une densité élevée des pièces forgées. Une série de traitements d’austénisation sur une gamme étendue de température variant entre 900 °C à 1250 °C a été effectuée ce qui nous a permis par la suite de connaître, pour chaque mélange, l’évolution de la taille des grains en fonction de la température d’austénisation. La nouvelle formulation de composition chimique a démontré un impact marqué quant au contrôle de la taille de grains en fonction de la température d’austénitisation. Une étude comparative nous a permis d’identifier la température de forgeage la plus appropriée pour ce type de pièces et de dégager la méthodologie à suivre en fonction des propriétés mécaniques et microstructurales.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose The purpose of the present study was to develop and describe a simple method to evaluate the rate of ion reabsorption of eccrine sweat glands in human using the measurement of galvanic skin conductance (GSC) and local sweating rate (SR). This purpose was investigated by comparing the SR threshold for increasing GSC with following two criteria of sweat ion reabsorption in earlier studies such as 1) the SR threshold for increasing sweat ion was at approximately 0.2 to 0.5 mg/cm2/min and 2) exercise-heat acclimation improved the sweat ion reabsorption ability and would increase the criteria 1. Methods Seven healthy non-heat-acclimated male subjects received passive heat treatment both before and after 7 days of cycling in hot conditions (50% maximum oxygen uptake, 60 min/day, ambient temperature 32°C, and 50% relative humidity). Results Subjects became partially heat-acclimated, as evidenced by the decreased end-exercise heart rate (p<0.01), rate of perceived exhaustion (p<0.01), and oesophageal temperature (p=0.07), without alterations in whole-body sweat loss, from the first to the last day of training. As hypothesised, we confirmed that the SR threshold for increasing GSC was near the predicted SR during passive heating before exercise heat acclimation, and increased significantly after training (0.19 ± 0.09 to 0.32 ± 0.10 mg/cm2/min, p<0.05). Conclusions The reproducibility of sweat ion reabsorption by the eccrine glands in the present study suggests that the relationship between GSC and SR can serve as a new index for assessing the maximum rate of sweat ion reabsorption of eccrine sweat glands in humans.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho foi realizado na Scania CV AB e teve como principal objectivo estabelecer uma diretriz sobre a possível utilização de aços vazados. Existe uma grande necessidade na realização deste trabalho, de forma a apoiar os engenheiros de projecto no seu processo de selecção dos materiais mais adequados, para produzir componentes mais leves e de elevado desempenho. Esta diretriz apresenta informação relacionada com propriedades mecânicas, processos de fundição, vazabilidade, tipologia de defeitos, tratamentos térmicos, soldabilidade e tratamentos superficiais dos aços vazados. Este trabalho foi limitado, na seleção de materiais para componentes do camião, a aços vazados que poderiam ser aplicados em dois componentes específicos: um componente estrutural da carroçaria sujeito a esforços de fadiga e a um colector de gases de combustão, sujeito a fluência, oxidação, fadiga por corrosão, fadiga-térmica e fadiga-mecânica. Foi realizado um benchmark focado nestes dois componentes de forma a saber que materiais são utilizados de momento por outras empresas concorrentes. Foi realizada ainda uma análise sobre possíveis materiais que possam ser aplicados em cada componente referido. Foi conduzida uma caracterização no estado bruto de fundição de um aço inoxidável vazado usado para produzir um protótipo do colector de gases. Esta caracterização consistiu numa análise microestrutural e medição de macro e microdurezas. Além da caracterização inicial, foram aplicados um conjunto de tratamentos térmicos, de forma a estudar a possibilidade de eliminar os carbonetos presentes inicialmente nas fronteiras de grão. As principais conclusões deste trabalho são que o aço vazado apresenta potencial para ser uma escolha válida em diversas aplicações, devido a um leque alargado de propriedades apresentadas tipicamente por este material. Relativamente a aplicações estruturais, o aço vazado é vantajoso comparativamente ao ferro fundido, quando são requeridos, por exemplo, soldabilidade e elevada resistência, combinada com elevada tenacidade à fractura. Para componentes sujeitos a elevadas temperaturas de serviço, o aço inoxidável vazado é vantajoso quando usado a temperaturas superiores a 750°C, apesar do seu elevado custo. O tratamento térmico composto por um recozimento de solubilização seguido de envelhecimento, elimina quase na totalidade os carbonetos presentes nas fronteiras de grão e verifica-se um aumento de dureza através de uma precipitação de carbonetos finamente dispersos na matriz, que poderão também aumentar a resistência à fluência.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Teräksenvalmistajilta edellytetään jatkuvasti panostusta laadun ja laadunvarmistuksen kehittämiseen. Teräksen laatu ja puhtaus korostuvat varsinkin silloin, kun terästä käytetään vaativiin käyttökohteisiin, kuten autoteollisuuden tarpeisiin. Ultraäänitarkastusmenetelmää käytetään laadun-varmistuksessa teräksen sisävikojen etsimiseen. Ultraäänitarkastuksessa lähetetään suuritaajuuksista ääntä kappaleeseen. Ääni etenee materiaalissa ja heijastuu erilaisista epäjatkuvuuskohdista. Luotaimeen palaavaa ääntä analysoimalla saadaan tietoa teräksestä ja sen sisävioista. Ultraäänitarkastuksen ongelmana on vian tyypin määrittäminen hankaluus sekä herkkyys tutkittavan materiaalin aineominaisuuksille. Työn tavoitteena oli immersioultraäänitarkastuksen kehittäminen sovellettuna teräksenvalmistajan tarpeisiin. Materiaalin aineominaisuuksista tutkittiin seostuksen vaikutusta. Teräslajit tarkastettiin valssitilaisena, karkaistuna ja normalisoituna. Lisäksi tutkittiin kappaleen pinnankarheuden ja -muodon vaikutusta tarkastukseen. Vikatyyppien tunnistamisen mahdollisuuksia ultra-äänitarkastuksessa selvitettiin käyttäen FFT- taajuusanalyysiä. Erilailla lämpökäsitellyillä teräslajeilla näytti eniten tuloksiin vaikuttavan terästen raekoko. Valssitilaisilla teräksillä raekoko on suuri, jolloin ultraääni vaimenee voimakkaasti teräksessä. Huomattavaa kuitenkin oli, että mikäli lämpö-käsittelyillä ei teräksen raekokoa saada juuri pienennettyä, ei myöskään vaimeneminen vähene. Tämän vuoksi lämpökäsittely ei välttämättä ole aina tarpeellinen valmisteltaessa ultraääninäytteitä. Fourier’n taajuusanalyysissä huomattiin olevan eroavaisuuksia verrattaessa huokosista ja sulkeumista palaavien kaikujen taajuusspektrejä. Näiden tulosten perusteella näyttäisi olevan mahdollista käyttää FFT- menetelmää ultraääni-tarkastuksessa vikojen luokitteluun.