948 resultados para Fixed numbers
Resumo:
ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.
Resumo:
To assess the intraocular pressure (IOP)-lowering effect of travoprost 0.004%/timolol 0.5% fixed-dose combination (TRAV/TIM-FC) in patients not achieving the target IOP of ≤18 mmHg while on timolol 0.5% (TIM) monotherapy. A multicenter, prospective, open-label study (NCT01336569) was conducted in patients with open-angle glaucoma or ocular hypertension. Eligible patients were receiving TIM monotherapy with a screening/baseline IOP of 19-35 mmHg in ≥1 eye. TIM was discontinued on the baseline visit day (no washout period) and TRAV/TIM-FC was initiated and administered once daily at 8 pm for 4-6 weeks. The primary efficacy variable was mean change in IOP from TIM-treated baseline to study end, measured by Goldmann applanation tonometry. Results were analyzed by analysis of variance and paired samples t-test (5% significance). A total of 49 patients were enrolled (mean age, 63 [range, 42-82] years; 55.1% White; 73.5% women), and 45 were included in the intent-to-treat (ITT) population. Mean duration of treatment with TRAV/TIM-FC was 31 days. Mean ± standard deviation IOP reduction from baseline (TIM) to the follow-up visit (TRAV/TIM-FC) was -5.0±3.6 mmHg. IOP decreased significantly (P<0.0001) from baseline (22.1±2.6 mmHg) to study end (17.1±3.9 mmHg) in the ITT population, with a mean IOP reduction of 22.3%. Most patients (n=33/45; 73.3%) achieved IOP ≤18 mmHg. Two patients experienced a total of four adverse events (AEs), including a patient who reported one serious AE (enterorrhagia) that was considered unrelated to treatment, and a patient who reported one event each of drug-related redness, pruritus, and foreign body sensation. Most patients (n=47/49; 95.9%) reported no AEs. TRAV/TIM-FC lowered IOP in patients who were not at target IOP while receiving TIM monotherapy, with most patients achieving an IOP ≤18 mmHg with TRAV/TIM-FC. TRAV/TIM-FC was well tolerated in this population.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Biociências - FCLAS
Resumo:
The vacuum energy of QED, as a function of the coupling constant α, is shown to have an absolute minimum at the critical coupling αc=π/3. The effect of chiral symmetry breaking diminishes as the coupling is increased. We argue that these aspects of the vacuum energy shall remain unaltered beyond the ladder approximation.
Resumo:
Background: Considering the limited qualitative and quantitative bone in the posterior arch, this modality of prosthetic treatment could provide a positive emotional factor reestablished by immovability of the anterior fixed implant-supported segment. Objective: This clinical report demonstrates the possibility of achieving positive results with a removable partial denture connected to an implant-supported fixed prosthesis associated to an extra resilient attachment. Clinical significance: In cases of posterior mandibular and maxilla atrophy added to the patients desire against the bone graft, this kind of prosthetic treatment has an important place as an alternative.
Resumo:
The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.
Resumo:
Protecting a network against link failures is a major challenge faced by network operators. The protection scheme has to address two important objectives - fast recovery and minimizing the amount of backup resources needed. Every protection algorithm is a tradeoff between these two objectives. In this paper, we study the problem of segment protection. In particular, we investigate what is the optimal segment size that obtains the best tradeoff between the time taken for recovery and minimizing the bandwidth used by the backup segments. We focus on the uniform fixed-length segment protection method, where each primary path is divided into fixed-length segments, with the exception of the last segment in the path. We observe that the optimal segment size for a given network depends on several factors such as the topology and the ratio of the costs involved.
Resumo:
The kind of rental arrangements for cropland vary widely in each locality and from one geographic area to another. What is desirable for one particular landlord/tenant relationship is not acceptable for others. The purpose of this publication is to help tenants and landlords develop fair cash-rent arrangements and assist them in making sound decisions based on a fair evaluation of resources. The first section addresses whether a fixed cash-rent lease arrangement should be used. Part II discusses how to develop a fair fixed cash rental rate, while Part III provides information on setting rent for other cropland, pasture, and buildings. Part IV outlines the advantages and disadvantages of flexible cash-leasing arrangements. Part V discusses the importance of developing a written lease agreement. A sample lease form also is included.
Resumo:
To open this Third Vertebrate Pest Conference is a real privilege. It is a pleasure to welcome all of you in attendance, and I know there are others who would like to be meeting with us, but, for one reason or another cannot be. However, we can serve them by taking back the results of discussion and by making available the printed transactions of what is said here. It has been the interest and demand for the proceedings of the two previous conferen- ces which, along with personal contacts many of you have with the sponsoring committee, have gauged the need for continuing these meetings. The National Pest Control Association officers who printed the 1962 proceedings still are supplying copies of that conference. Two reprintings of the 1964 conference have been necessary and repeat orders from several universities indicate that those proceedings have become textbooks for special classes. When Dr. Howard mentioned in opening the first Conference in 1962 that publication of those papers would make a valuable handbook of animal control, he was prophetic, indeed. We are pleased that this has happened, but not surprised, since to many of us in this specialized field, the conferences have provided a unique opportunity to meet colleagues with similar interests, to exchange information on control techniques and to be informed by research workers of problem solving investigations as well as to hear of promising basic research. The development of research is a two-way street and we think these conferences also identify areas of inadequate knowledge, thereby stimulating needed research. We have represented here a number of types of specialists—animal ecologists, public health and transmissible disease experts, control methods specialists, public agency administration and enforcement staffs, agricultural extension people, manufacturing and sale industry representatives, commercial pest control operators, and others—and in addition to improving communications among these professional groups an equally important purpose of these conferences is to improve understanding between them and the general public. Within the term general public are many individuals and also organizations dedicated to appreciation and protection of certain animal forms or animal life in general. Proper concepts of vertebrate pest control do not conflict with such views. It is worth repeating for the record the definition of "vertebrate pest" which has been stated at our previous conferences. "A vertebrate pest is any native or introduced, wild or feral, non-human spe- cies of vertebrate animal that is currently troublesome locally or over a wide area to one or more persons either by being a general nuisance, a health hazard or by destroying food or natural resources. In other words, vertebrate pest status is not an inherent quality or fixed classification but is a circumstantial relationship to man's interests." I believe progress has been made in reducing the misunderstanding and emotion with which vertebrate pest control was formerly treated whenever a necessity for control was stated. If this is true, I likewise believe it is deserved, because control methods and programs have progressed. Control no longer refers only to population reductions by lethal means. We have learned something of alternate control approaches and the necessity for studying the total environment; where reduction of pest animal numbers is the required solution to a problem situation we have a wider choice of more selective, safe and efficient materials. Although increased attention has been given to control methods, research when we take a close look at the severity of animal damage to so many facets of our economy, particularly to agricultural production and public health, we realize it still is pitifully small and slow. The tremendous acceleration of the world's food and health requirements seems to demand expediting vertebrate pest control to effectively neutralize the enormous impact of animal damage to vital resources. The efforts we are making here at problem delineation, idea communication and exchange of methodology could well serve as both nucleus and rough model for a broader application elsewhere. I know we all hope this Third Conference will advance these general objectives, and I think there is no doubt of its value in increasing our own scope of information.