975 resultados para False alarms


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: HIV surveillance requires monitoring of new HIV diagnoses and differentiation of incident and older infections. In 2008, Switzerland implemented a system for monitoring incident HIV infections based on the results of a line immunoassay (Inno-Lia) mandatorily conducted for HIV confirmation and type differentiation (HIV-1, HIV-2) of all newly diagnosed patients. Based on this system, we assessed the proportion of incident HIV infection among newly diagnosed cases in Switzerland during 2008-2013. METHODS AND RESULTS: Inno-Lia antibody reaction patterns recorded in anonymous HIV notifications to the federal health authority were classified by 10 published algorithms into incident (up to 12 months) or older infections. Utilizing these data, annual incident infection estimates were obtained in two ways, (i) based on the diagnostic performance of the algorithms and utilizing the relationship 'incident = true incident + false incident', (ii) based on the window-periods of the algorithms and utilizing the relationship 'Prevalence = Incidence x Duration'. From 2008-2013, 3'851 HIV notifications were received. Adult HIV-1 infections amounted to 3'809 cases, and 3'636 of them (95.5%) contained Inno-Lia data. Incident infection totals calculated were similar for the performance- and window-based methods, amounting on average to 1'755 (95% confidence interval, 1588-1923) and 1'790 cases (95% CI, 1679-1900), respectively. More than half of these were among men who had sex with men. Both methods showed a continuous decline of annual incident infections 2008-2013, totaling -59.5% and -50.2%, respectively. The decline of incident infections continued even in 2012, when a 15% increase in HIV notifications had been observed. This increase was entirely due to older infections. Overall declines 2008-2013 were of similar extent among the major transmission groups. CONCLUSIONS: Inno-Lia based incident HIV-1 infection surveillance proved useful and reliable. It represents a free, additional public health benefit of the use of this relatively costly test for HIV confirmation and type differentiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Maternal mortality is a major public-health problem in developing countries. Extreme differences in maternal mortality rates between developed and developing countries indicate that most of these deaths are preventable. Most information on the causes of maternal death in these areas is based on clinical records and verbal autopsies. Clinical diagnostic errors may play a significant role in this problem and might also have major implications for the evaluation of current estimations of causes of maternal death. Methods and Findings A retrospective analysis of clinico-pathologic correlation was carried out, using necropsy as the gold standard for diagnosis. All maternal autopsies (n ¼ 139) during the period from October 2002 to December 2004 at the Maputo Central Hospital, Mozambique were included and major diagnostic discrepancies were analyzed (i.e., those involving the cause of death). Major diagnostic errors were detected in 56 (40.3%) maternal deaths. A high rate of false negative diagnoses was observed for infectious diseases, which showed sensitivities under 50%: HIV/AIDS-related conditions (33.3%), pyogenic bronchopneumonia (35.3%), pyogenic meningitis (40.0%), and puerperal septicemia (50.0%). Eclampsia, was the main source of false positive diagnoses, showing a low predictive positive value (42.9%). Conclusions Clinico-pathological discrepancies may have a significant impact on maternal mortality in sub-Saharan Africa and question the validity of reports based on clinical data or verbal autopsies. Increasing clinical awareness of the impact of obstetric and nonobstetric infections with their inclusion in the differential diagnosis, together with a thorough evaluation of cases clinically thought to be eclampsia, could have a significant impact on the reduction of maternal mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli antaa kuva vastapainevoimalaitoksen automaation toiminnallisesta suunnittelusta ja soveltaa teoriaa suunnittelemalla toiminnallisuus vesihöyrypiirin tärkeimmille osuuksille. Työssä on esitelty tyypillinen EPCM-voimalaitosprojekti, joka toteutetaan ulkopuolisen avustajan kanssa tehdyllä yhteistyöllä. Projektin koostuu laitoksen suunnittelu-, rakennus-, asennus- sekä käyttöönottovaiheista. Huomioitavia asioita ovat mm. projektin budjetti sekä aikataulu. Valvonnalla on suuri merkitys projektin onnistumiseen. Lisäksi työssä esitellään vastapainevoimalaitoksen vesihöyrypiirin prosessi, pääsäädöt sekä automaatiojärjestelmä. Vesihöyrypiirillä tarkoitetaan syöttövesi-, höyry- ja kaukolämpöjärjestelmää. Pääsäädöillä pyritään saamaan tuotanto vastaamaan kulutusta. Voimalaitoksen painopiste on kaukolämmön tuottaminen. Automaatiojärjestelmän toiminnoilla tarkoitetaan järjestelmän suorittamia ohjauksia, säätöjä sekä hälytyksiä. Toiminnallisessa suunnittelussa tehdään toimilaitteille niin yksittäisohjaukset, säädöt kuin hälytysluettelot. Työssä tehty toiminnallinen suunnittelu keskittyy erityisesti toimilaitteiden säätöpiireihin. Säätöpiirit koostuvat tärkeimmistä prosessiin liittyvistä komponenteista ja säätömerkeistä. Toiminnallisen suunnittelun dokumentaatioita käytetään automaatiojärjestelmän sovellusohjelmoinnin pohjana.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Maternal mortality is a major public-health problem in developing countries. Extreme differences in maternal mortality rates between developed and developing countries indicate that most of these deaths are preventable. Most information on the causes of maternal death in these areas is based on clinical records and verbal autopsies. Clinical diagnostic errors may play a significant role in this problem and might also have major implications for the evaluation of current estimations of causes of maternal death. Methods and Findings A retrospective analysis of clinico-pathologic correlation was carried out, using necropsy as the gold standard for diagnosis. All maternal autopsies (n ¼ 139) during the period from October 2002 to December 2004 at the Maputo Central Hospital, Mozambique were included and major diagnostic discrepancies were analyzed (i.e., those involving the cause of death). Major diagnostic errors were detected in 56 (40.3%) maternal deaths. A high rate of false negative diagnoses was observed for infectious diseases, which showed sensitivities under 50%: HIV/AIDS-related conditions (33.3%), pyogenic bronchopneumonia (35.3%), pyogenic meningitis (40.0%), and puerperal septicemia (50.0%). Eclampsia, was the main source of false positive diagnoses, showing a low predictive positive value (42.9%). Conclusions Clinico-pathological discrepancies may have a significant impact on maternal mortality in sub-Saharan Africa and question the validity of reports based on clinical data or verbal autopsies. Increasing clinical awareness of the impact of obstetric and nonobstetric infections with their inclusion in the differential diagnosis, together with a thorough evaluation of cases clinically thought to be eclampsia, could have a significant impact on the reduction of maternal mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For decades, lung cancer has been the most common cancer in terms of both incidence and mortality. There has been very little improvement in the prognosis of lung cancer. Early treatment following early diagnosis is considered to have potential for development. The National Lung Screening Trial (NLST), a large, well-designed randomized controlled trial, evaluated low-dose computed tomography (LDCT) as a screening tool for lung cancer. Compared with chest X-ray, annual LDCT screening reduced death from lung cancer and overall mortality by 20 and 6.7 %, respectively, in high-risk people aged 55-74 years. Several smaller trials of LDCT screening are under way, but none are sufficiently powered to detect a 20 % reduction in lung cancer death. Thus, it is very unlikely that the NLST results will be replicated. In addition, the NLST raises several issues related to screening, such as the high false-positive rate, overdiagnosis and cost. Healthcare providers and systems are now left with the question of whether the available findings should be translated into practice. We present the main reasons for implementing lung cancer screening in high-risk adults and discuss the main issues related to lung cancer screening. We stress the importance of eligibility criteria, smoking cessation programs, primary care physicians, and informed-decision making should lung cancer screening be implemented. Seven years ago, we were waiting for the results of trials. Such evidence is now available. Similar to almost all other cancer screens, uncertainties exist and persist even after recent scientific efforts and data. We believe that by staying within the characteristics of the original trial and appropriately sharing the evidence as well as the uncertainties, it is reasonable to implement a LDCT lung cancer screening program for smokers and former smokers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The measurement of calcitonin in washout fluids of thyroid nodule aspirate (FNA-calcitonin) has been reported as accurate to detect medullary thyroid carcinoma (MTC). The results from these studies have been promising and the most updated version of ATA guidelines quoted for the first time that "FNA findings that are inconclusive or suggestive of MTC should have calcitonin measured in the FNA washout fluid." Here we aimed to systematically review published data on this topic to provide more robust estimates. RESEARCH DESIGN AND METHODS: A comprehensive computer literature search of the medical databases was conducted by searching for the terms "calcitonin" AND "washout." The search was updated until April 2015. RESULTS: Twelve relevant studies, published between 2007 and 2014, were found. Overall, 413 thyroid nodules or neck lymph nodes underwent FNA-calcitonin, 95 were MTC lesions and 93 (97.9%) of these were correctly detected by this measurement regardless of their cytologic report. CONCLUSIONS: The present study shows that the above ATA recommendation is well supported. Almost all MTC lesions are correctly detected by FNA-calcitonin and this technique should be used to avoid false negative or inconclusive results from cytology. The routine determination of serum calcitonin in patients undergoing FNA should improve the selection of patients at risk for MTC, guiding the use of FNA-calcitonin in the same FNA sample and providing useful information to the cytopathologist for the morphological assessment and the application of tailored ancillary tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diagnosis of pleural plaques (PPs) is commonly straightforward, especially when a typical appearance is observed in a context of previous asbestos exposure. Nevertheless, numerous causes of focal pleural thickening may be seen in routine practice. They may be related to normal structures, functional pleural thickening, previous tuberculosis, pleural metastasis, silicosis or other rarer conditions. An application of a rigorous technical approach as well as a familiarity with loco-regional anatomy and the knowledge of typical aspects of PP are required. Indeed, false-positive or false-negative results may engender psychological and medico-legal consequences or can delay diagnosis of malignant pleural involvement. Correct recognition of PPs is crucial, as they may also be an independent risk factor for mortality from lung cancer in asbestos-exposed workers particularly in either smokers or former/ex-smokers. Finally, the presence of PP(s) may help in considering asbestosis as a cause of interstitial lung disease predominating in the subpleural area of the lower lobes. The aim of this pictorial essay is to provide a brief reminder of the normal anatomy of the pleura and its surroundings as well as the various aspects of PPs. Afterwards, the common pitfalls encountered in PP diagnosis will be emphasized and practical clues to differentiate actual plaque and pseudoplaque will be concisely described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The main utility of 18-fluorodeoxyglucose positron emission tomography (FDG-PET) lies in the staging of lung cancer. However, it can also be used to differentiate indeterminate pulmonary lesions, but its impact on the resection of benign lesions at surgery is unknown. The aim of this study was to compare the prevalence of benign lesions at thoracotomy carried out for suspected lung cancer, before and after the introduction of PET scanning in a large thoracic surgical centre. MATERIALS AND METHODS: We reviewed our prospectively recorded surgical database for all consecutive patients undergoing thoracotomy for suspected or proven lung cancer and compared the prevalence of benign lesions in 2 consecutive 2-year groups, before (group I) and after (group II) the introduction of FDG-PET scan respectively. RESULTS: Surgical resection was performed on 1233 patients during the study period. The prevalence of benign lesions at surgery in groups I and II was similar (44/626 and 41/607, both 7%), and also in group II between those who underwent FDG-PET scan and the remainder (21/301 and 20/306 respectively, both 7%). In group II, of the 21 patients with benign lesions, who underwent FDG-PET, 19 had a false positive scan (mean standardised uptake value 5.3 [range 2.6-12.7]). Of these, 13 and 4 patients respectively had non-diagnostic bronchoscopy and percutaneous transthoracic lung biopsy pre thoracotomy. There was no difference in the proportion of different benign lesions resected between group I and those with FDG-PET in group II. CONCLUSION: The introduction of FDG-PET scanning has not altered the proportion of patients undergoing thoracotomy for ultimately benign lesions, mainly due to the avidity for the isotope of some non-malignant lesions. Such false positive results need to be considered when patients with unconfirmed lung cancer are contemplated for surgical resection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractObjective:To compare the accuracy of computer-aided ultrasound (US) and magnetic resonance imaging (MRI) by means of hepatorenal gradient analysis in the evaluation of nonalcoholic fatty liver disease (NAFLD) in adolescents.Materials and Methods:This prospective, cross-sectional study evaluated 50 adolescents (aged 11–17 years), including 24 obese and 26 eutrophic individuals. All adolescents underwent computer-aided US, MRI, laboratory tests, and anthropometric evaluation. Sensitivity, specificity, positive and negative predictive values and accuracy were evaluated for both imaging methods, with subsequent generation of the receiver operating characteristic (ROC) curve and calculation of the area under the ROC curve to determine the most appropriate cutoff point for the hepatorenal gradient in order to predict the degree of steatosis, utilizing MRI results as the gold-standard.Results:The obese group included 29.2% girls and 70.8% boys, and the eutrophic group, 69.2% girls and 30.8% boys. The prevalence of NAFLD corresponded to 19.2% for the eutrophic group and 83% for the obese group. The ROC curve generated for the hepatorenal gradient with a cutoff point of 13 presented 100% sensitivity and 100% specificity. As the same cutoff point was considered for the eutrophic group, false-positive results were observed in 9.5% of cases (90.5% specificity) and false-negative results in 0% (100% sensitivity).Conclusion:Computer-aided US with hepatorenal gradient calculation is a simple and noninvasive technique for semiquantitative evaluation of hepatic echogenicity and could be useful in the follow-up of adolescents with NAFLD, population screening for this disease as well as for clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractMagnetic resonance imaging has revolutionized the diagnosis of shoulder lesions, in many cases becoming the method of choice. However, anatomical variations, artifacts and the particularity of the method may be a source of pitfalls, especially for less experienced radiologists. In order to avoid false-positive and false-negative results, the authors carried out a compilation of imaging findings that may simulate injury. It is the authors’ intention to provide a useful, consistent and comprehensive reference for both beginner residents and skilled radiologists who work with musculoskeletal magnetic resonance imaging, allowing for them to develop more precise reports and helping them to avoid making mistakes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Screening mammography is the only imaging modality with proved decrease in breast cancer mortality. Ultrasound has been proposed as additional tool for screening. Controversies remain about the real value of sonography in this setting. In Caucasian women with dense breast, sonography improves significantly breast cancer detection, but also increases the false positive cases, biopsies and costs. A careful selection of women who may benefit from additional screening with sonography is mandatory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify reliable predictors of outcome in comatose patients after cardiac arrest using a single routine EEG and standardized interpretation according to the terminology proposed by the American Clinical Neurophysiology Society. METHODS: In this cohort study, 4 EEG specialists, blinded to outcome, evaluated prospectively recorded EEGs in the Target Temperature Management trial (TTM trial) that randomized patients to 33°C vs 36°C. Routine EEG was performed in patients still comatose after rewarming. EEGs were classified into highly malignant (suppression, suppression with periodic discharges, burst-suppression), malignant (periodic or rhythmic patterns, pathological or nonreactive background), and benign EEG (absence of malignant features). Poor outcome was defined as best Cerebral Performance Category score 3-5 until 180 days. RESULTS: Eight TTM sites randomized 202 patients. EEGs were recorded in 103 patients at a median 77 hours after cardiac arrest; 37% had a highly malignant EEG and all had a poor outcome (specificity 100%, sensitivity 50%). Any malignant EEG feature had a low specificity to predict poor prognosis (48%) but if 2 malignant EEG features were present specificity increased to 96% (p < 0.001). Specificity and sensitivity were not significantly affected by targeted temperature or sedation. A benign EEG was found in 1% of the patients with a poor outcome. CONCLUSIONS: Highly malignant EEG after rewarming reliably predicted poor outcome in half of patients without false predictions. An isolated finding of a single malignant feature did not predict poor outcome whereas a benign EEG was highly predictive of a good outcome.