993 resultados para Fabry-Perot Lasers
Resumo:
The report compares and contrasts the automated PASCO method of pavement evaluation to the manual procedures used by the Iowa Department of Transportation (DOT) to evaluate pavement condition. Iowa DOT's use of IJK and BPR roadmeters and manual crack and patch surveys are compared to PASCO's use of 35-mm photography, artificial lighting and hairline projection, tracking wheels and lasers to measure ride, cracking and patching, rut depths, and roughness. The Iowa DOT method provides a Present Serviceability Index (PSI) value and PASCO provides a Maintenance Control Index (MCI). Seven sections of Interstate Highway, county roads and city streets, and one shoulder section were tested with different speeds of data collection, surface types and textures, and stop and start conditions. High correlation of results between the two methods in the measurement of roughness (0.93 for the tracking wheel and 0.84 for the laser method) were recorded. Rut depth correlations of 0.61 and cracking of 0.32 are attributed to PASCO's more comprehensive measurement techniques. A cost analysis of the data provided by both systems indicates that PASCO is capable of providing a comparable result with improved accuracy at a cost of $125-$150 or less per two-lane mile depending on survey mileage. Improved data collection speed, accuracy, and reliability, and a visible record of pavement condition for comparable costs are available. The PASCO system's ability to provide the data required in the Highway Pavement Distress Identification Manual, the Pavement Condition Rating Guide, and the Strategic Highway Research Program Long Term Pavement Performance (LTPP) Studies, is also outlined in the report.
Resumo:
Lasers are essential tools for cell isolation and monolithic interconnection in thin-film-silicon photovoltaic technologies. Laser ablation of transparent conductive oxides (TCOs), amorphous silicon structures and back contact removal are standard processes in industry for monolithic device interconnection. However, material ablation with minimum debris and small heat affected zone is one of the main difficulty is to achieve, to reduce costs and to improve device efficiency. In this paper we present recent results in laser ablation of photovoltaic materials using excimer and UV wavelengths of diode-pumped solid-state (DPSS) laser sources. We discuss results concerning UV ablation of different TCO and thin-film silicon (a-Si:H and nc-Si:H), focussing our study on ablation threshold measurements and process-quality assessment using advanced optical microscopy techniques. In that way we show the advantages of using UV wavelengths for minimizing the characteristic material thermal affection of laser irradiation in the ns regime at higher wavelengths. Additionally we include preliminary results of selective ablation of film on film structures irradiating from the film side (direct writing configuration) including the problem of selective ablation of ZnO films on a-Si:H layers. In that way we demonstrate the potential use of UV wavelengths of fully commercial laser sources as an alternative to standard backscribing process in device fabrication.
Resumo:
Objective: To compare the results obtained after oral mucocele resection with the scalpel versus the CO2 laser, based on the complications and recurrences after surgery Patients and Methods: Of the 68 patients we studied who have mucocele, 38 were resected with a scalpel and the remaining 30 with the CO2 laser (5-7 W). Patient sex and age were documented, along with location of the lesion as well as size, symptoms, duration, etiological factors, type of treatment, complications and recurrences after surgical removal. Results: The sample comprised 40 males and 28 females, aged between 6-65 years. The histological diagnosis was extravasation mucocele in 95% of the cases. The most frequent location was the lower lip (73.5%). The mean lesion diameter was 9 mm , and in most cases no evident etiological factor was recorded. The mean duration of the lesion was 4 months. Among the cases of conventional surgical removal of mucocele, recurrence was recorded in 8.8% of the cases, and 13.2% of the patients suffered postoperative complications - the most frequent being the presence of fibrous scars. There were no complications or relapses after a minimum follow-up of 12 months in the cases subjected to CO2 laser treatment. Conclusions: Oral mucocele ablation with the CO2 laser offers more predictable results and fewer complications and recurrences than conventional resection with the scalpel
Resumo:
Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages
Resumo:
A les línies de producció de l’empresa Laboratorios Hipra, s’ha plantejat imprimir els codis de les caixes mitjançant nous làsers amb la tècnica de delineat làser, amb aquests nous models de làser es vol imprimir codis datamatrix. Per tal que això sigui possible, és molt important poder tenir un control de les impressions realitzades pel làser, ja que en cas contrari, podrien empaquetar-se caixes amb un marcatge erroni. S’ha dissenyatuna aplicació capaç de verificar i controlar les impressions realitzades pels làsers. Aquesta aplicació ha de ser capaç de verificar i controlar les caixes marcades tant amb codis de barres com amb datamatrix, a més a més de mostrar totes les dades dels marcatges per una pantalla SCADA. L’aplicació també incorpora un sistema d’expulsió de les caixes amb un marcatge d’inferior qualitat a la desitjada en cada moment
Resumo:
Objectives: To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. Study design: A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Results: Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Conclusions: Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing.
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).
Resumo:
BACKGROUND AND OBJECTIVE: Experimental assessment of anticancer effect, normal tissue damage, and toxicity of intrathoracic mTHPC-mediated photodynamic therapy (PDT) combined to surgery in malignant pleural mesothelioma (MPM) bearing rats. STUDY DESIGN/MATERIALS AND METHODS: Six days after implantation of syngenic malignant mesothelioma cells in the left chest cavity of Fischer rats (n = 21) and 4 days after sensitization (0.1 mg/kg mTHPC), a left-sided pneumonectomy was performed, followed by intraoperative light delivery (652 nm, fluence 20 J/cm(2)), either by spherical illumination of the chest cavity (fluence rate 15 mW/cm(2)) or by focal illumination of a tumor area (fluence rate 150 mW/cm(2)). Controls comprised tumor-bearing untreated animals, tumor-bearing animals undergoing pneumonectomy, and tumor-bearing animals undergoing pneumonectomy and light delivery without sensitization or sensitization without light delivery. No thoracocentesis was performed during follow-up. RESULTS: An invasively growing sarcomatous type of mesothelioma was found in all animals at day 10, without tumor necrosis in control animals. PDT resulted in 0.5-1 mm deep inhomogeneous tumor necrosis after spherical, and in a 1-2 mm deep tumor necrosis after focal illumination. No injury to mediastinal organs was observed, neither after PDT with spherical nor with focal light delivery except focal interstitial lung fibrosis at the mediastinal area of the opposite lung. All animals with pneumonectomy followed by spherical PDT of the entire tumor-bearing chest cavity died within 72 hours whereas all other animals survived. All animals that died presented massive pleural effusion. CONCLUSIONS: PDT following pneumonectomy in mesothelioma bearing rats was technically feasible and allowed to study its effect on tumor and normal tissues. PDT-related tumor necrosis was observed after spherical and focal light delivery, however, pneumonectomy followed by PDT with spherical light delivery to the tumor-bearing chest cavity resulted in fatal complications.
Resumo:
Ten Pneumocystis jirovecii pneumonia (PCP) cases were diagnosed in renal transplant recipients (RTRs) during a 3-year period. Nosocomial transmission from HIV-positive patients with PCP was suspected because these patients shared the same hospital building, were not isolated, and were receiving suboptimal anti-PCP prophylaxis or none. P. jirovecii organisms were typed with the multitarget polymerase chain reaction-single-strand conformation polymorphism method. Among the 45 patients with PCP hospitalized during the 3-year period, 8 RTRs and 6 HIV-infected patients may have encountered at least 1 patient with active PCP within the 3 months before the diagnosis of their own PCP episode. In six instances (five RTRs, one HIV-infected patient), the patients harbored the same P. jirovecii molecular type as that found in the encountered PCP patients. The data suggest that part of the PCP cases observed in this building, particularly those observed in RTRs, were related to nosocomial interhuman transmission.
Resumo:
Colorectal cancer frequently disseminates through the portal vein into the liver. In this study, outbred Swiss nude mice were adapted to facilitate the induction of liver metastases by a pre-grafting treatment with 6 Gy total body irradiation and i.v. injection of anti-asialo GM1 antibody. One day later, cultured LS 174T human colon cancer cells were injected into the surgically exposed spleen, which was resected 3 min later. In 48 of 65 mice, a few to several hundred liver metastases were macroscopically observed at dissection 3 to 4 weeks after transplantation. Ten of 10 mice, followed-up for survival, died with multiple large confluent liver metastases. By reducing the radiation dose to 4 or 0 Gy, or omitting the anti-asialo GM1 antibody injection, only 60%, 37% or 50% of mice, respectively, had visible metastases 3 weeks after transplantation. Carcinoembryonic antigen (CEA) measured in tumour extracts was in the mean 25.6 micrograms/g in liver metastases compared with 9.2 micrograms/g in s.c. tumours. Uptake of radiolabelled anti-CEA monoclonal antibody (MAb) in the metastases 12, 24 and 48 hr after injection gave a mean value of 39% of the injected dose per gram of tissue (ID/g). In comparison, MAb uptake in s.c. and intrasplenic tumours or lung metastases gave a mean percentage ID/g of 20, 18 and 15, respectively. Laser-induced fluorescence after injection of indocyanin-MAb conjugate allowed direct visual detection of small liver metastases, including some that were not visible under normal light. Preliminary results showed that mice, pre-treated with 4 Gy irradiation and the anti-asialo GM1 injection, were tolerant to radioimmunotherapy with a total dose of 500 muCi 131I labeled anti-CEA intact MAbs given in 3 injections.
Resumo:
This case study deals with a rock face monitoring in urban areas using a Terrestrial Laser Scanner. The pilot study area is an almost vertical, fifty meter high cliff, on top of which the village of Castellfollit de la Roca is located. Rockfall activity is currently causing a retreat of the rock face, which may endanger the houses located at its edge. TLS datasets consist of high density 3-D point clouds acquired from five stations, nine times in a time span of 22 months (from March 2006 to January 2008). The change detection, i.e. rockfalls, was performed through a sequential comparison of datasets. Two types of mass movement were detected in the monitoring period: (a) detachment of single basaltic columns, with magnitudes below 1.5 m3 and (b) detachment of groups of columns, with magnitudes of 1.5 to 150 m3. Furthermore, the historical record revealed (c) the occurrence of slab failures with magnitudes higher than 150 m3. Displacements of a likely slab failure were measured, suggesting an apparent stationary stage. Even failures are clearly episodic, our results, together with the study of the historical record, enabled us to estimate a mean detachment of material from 46 to 91.5 m3 year¿1. The application of TLS considerably improved our understanding of rockfall phenomena in the study area.