1000 resultados para F test
Resumo:
Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
Among studies focused on increasing soybean grain yield, the ones related to sowing process are the most significant. Considering that soybean has an epigeal emergence, it becomes difficult to hint at the length covered by hypocotyl up to soil surface, or the actual planting depth. This study aimed to find an indicator that allows the identification of an ideal soybean planting depth. For this purpose, two complementary assays has been carried out in a greenhouse. The first aimed to identify structures that could be indicators of seed planting depth, on a medium-textured soil from Campos Gerais region, in the state of Paraná, Brazil. Spring NK 8350 cultivar seeds were sown at five theoretical depths (1, 2, 3, 4 and 5 cm). As seedlings emerged, the “differentiation zone” and the “root curve” depths were measured. The second assay was the validation of the suggested indicators in assay 1 from two soils, one medium-textured and one clay-textured. For this assay, it was used BRS 232. Both the methodologies showed high correlation with the theoretical planting depth. Although their correlation coefficient values were close, the differentiation zone appeared to be the most efficient reference with less planting depth overestimation.
Resumo:
CHARGE syndrome, Sotos syndrome and 3p deletion syndrome are examples of rare inherited syndromes that have been recognized for decades but for which the molecular diagnostics only have been made possible by recent advances in genomic research. Despite these advances, development of diagnostic tests for rare syndromes has been hindered by diagnostic laboratories having limited funds for test development, and their prioritization of tests for which a (relatively) high demand can be expected. In this study, the molecular diagnostic tests for CHARGE syndrome and Sotos syndrome were developed, resulting in their successful translation into routine diagnostic testing in the laboratory of Medical Genetics (UTUlab). In the CHARGE syndrome group, mutation was identified in 40.5% of the patients and in the Sotos syndrome group, in 34%, reflecting the use of the tests in routine diagnostics in differential diagnostics. In CHARGE syndrome, the low prevalence of structural aberrations was also confirmed. In 3p deletion syndrome, it was shown that small terminal deletions are not causative for the syndrome, and that testing with arraybased analysis provides a reliable estimate of the deletion size but benign copy number variants complicate result interpretation. During the development of the tests, it was discovered that finding an optimal molecular diagnostic strategy for a given syndrome is always a compromise between the sensitivity, specificity and feasibility of applying a new method. In addition, the clinical utility of the test should be considered prior to test development: sometimes a test performing well in a laboratory has limited utility for the patient, whereas a test performing poorly in the laboratory may have a great impact on the patient and their family. At present, the development of next generation sequencing methods is changing the concept of molecular diagnostics of rare diseases from single tests towards whole-genome analysis.
Resumo:
kuv., 8 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 8 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
OBJETIVO: correlacionar as queixas de incontinência urinária de esforço e os resultados da aplicação do pad test de uma hora em mulheres na pré e pós-menopausa. MÉTODOS: estudo transversal, composto por 60 voluntárias na pós-menopausa, divididas em dois grupos: um com 34 mulheres com queixa de perda involuntária de urina aos esforços, outro com 26 mulheres sem queixas de perda de urina aos esforços. Há também a presença de um Grupo Controle composto por 15 mulheres na pré-menopausa, com ciclo menstrual normal e sem queixas urinárias. Todas as mulheres foram avaliadas quanto à clínica e laboratorialmente, e submetidas ao pad test por uma hora. A paciente foi considerada incontinente quando o peso do absorvente após o teste foi maior do que 1 g. Os resultados obtidos foram submetidos à estatística descritiva, ao teste paramétrico ANOVA, ao pós-teste de Turkey e à correlação de Pearson. RESULTADOS: todas as mulheres na pós-menopausa apresentaram incontinência urinária de esforço durante o pad test, tanto as que referiram perda urinária (4 g), como as sem perda urinária prévia (3,5 g). Nessas mulheres, observou-se uma forte correlação das perdas de urina com o tempo de menopausa (r=0,8; p<0,01) e com o índice de massa corpórea (IMC) (r=0,7; p= 0,01). As mulheres na pré-menopausa mantiveram-se continentes durante o pad test (0,4 g). CONCLUSÕES: os resultados obtidos com a aplicação do pad test de uma hora mostraram que todas as mulheres na pós-menopausa apresentavam incontinência urinária de esforço, inclusive aquelas que não apresentavam queixa de perda de urina aos esforços. Essa perda de urina correlaciona-se com o tempo de menopausa e com o IMC.
Resumo:
O "California Mastitis Test" (CMT) estima o conteúdo de células somáticas no leite e é interpretado subjetivamente, estabelecendo-se escores que, na maioria dos casos, variam de 1 a 5. O escore 1 indica uma reação completamente negativa e os de 2-5 indicam graus crescentes de resposta inflamatória do úbere, sendo normalmente considerados como indicativos de mastite subclínica. Dependendo da interpretação dos escores, o CMT pode produzir resultados falso-positivos ou falso-negativos. Esse trabalho teve o objetivo de avaliar a sensibilidade e a especificidade do CMT em relação à contagem de células somáticas (CCS). Foram utilizadas 3.012 amostras de leite provenientes de 760 vacas Holandesas ou mestiças Holandês-Zebu, pertencentes a 15 rebanhos. Todas as amostras foram submetidas ao CMT e processadas para CCS em equipamento Fossomatic 90. Os valores médios de CCS (x 1.000 células/ml) obtidos para os escores de CMT foram 1 (79,9), 2 (333,5), 3 (670,3), 4 (1.354,0) e 5 (4.455,6). Três opções de interpretação (doente/não-doente) para o CMT foram testadas, em relação aos valores de CCS, iniciando com 100.000 células/ml: (a) 1 versus 2, 3, 4, e 5; (b) 1 e 2 versus 3, 4 e 5; (c) 1, 2, 3 versus 4 e 5. As sensibilidades do CMT em identificar corretamente quartos mamários acima de 200.000 células/ml foram 79%, 61% e 34%, para as opções a, b e c, respectivamente. Para identificar corretamente contagens acima de 500.000 células/ml, as sensibilidades do CMT, para as opções a, b e c, foram, respectivamente: 93%, 82% e 54%. A sensibilidade do CMT em identificar quartos mamários com mastite subclínica foi adequada (acima de 80%) quando a interpretação do teste foi mais rigorosa (opções a e b). A interpretação da reação 3 como negativa (opção c) só alcançou sensibilidade de 80% para contagens entre 1.200.000 e 1.400.000 células/ml. As especificidades do CMT, para CCS de 200.000 e 500.000 foram, respectivamente, 90% e 80% (opção a), 97% e 90% (opção b) e 99% e 97% (opção c).
Resumo:
A rapid conglutination test (RCT) with performance comparable to the indirect fluorescent antibody technique (IFAT) was developed to detect antibodies against Babesia bigemina (B. bigemina-RCT). The B. bigemina-RCT is a sensitive, specific, economical, and rapidly performed serological test suitable for field application or minimally equipped laboratories. This test had a sensitivity of 90.9%, and specificity of 97.6%, compared to IFAT, which showed for the same parameters respectively, 98.3% and 99.7%. The early detection of anti- B. bigemina immunoglobulins by RCT in experimental infections was nearly parallel to that of IFAT. Cross reactions were observed with sera from calves experimentally infected with Babesia bovis (1.8%) and with Anaplasma marginale (1.2%). RCT antigen prepared with non parasitized erythrocytes (negative antigen) showed 1.5%, 3.5% and 2.2% of positive reactions with sera from animals experimentally infected with B. bigemina, B. bovis and A. marginale. However, none of the sera from animals of endemic areas for babesia infection resulted in positive reactions with the negative antigen. Considering these results and shelf life over six months, the B. bigemina-RCT could be used for epidemiological surveys and evaluation of control measures against this species of Babesia.