990 resultados para Eye, Artificial
Resumo:
An experimental artificial reefwas constructed in Strangford Lough, Northern Ireland as part of trials to regenerate damaged biogenic reefs formed by the horse mussel Modiolus modiolus. Experimental reef plots were constructed using Pecten maximus shell as cultch. Clumps of live adult M. modiolus were translocated from nearby natural reefs into cultchwith a high profile (elevated cultch), cultch with a lowprofile (flattened cultch), as well as directly into the seafloor. The aim of the study was to test the hypothesis that translocated mussel clumps would increase habitat complexity thus accelerating community succession and enhancing natural recruitment of M. modiolus spat. These effects were predicted to be greater on elevated cultch due to greater protection from
predators and increased accessibility to food resources. Within the artificial reef array the translocated clumps had a significant positive effect on recruitment compared to cultch without mussels with average densities of spat settled on the translocated M. modiolus clumps ranging from 100 to 200 individuals m-2 compared to 4 to 52 spat m-2 on cultch without mussels. Recruitment of M. modiolus spat was also significantly higher on translocated horse mussels when compared to natural reefs where densities of 8–36 spat m-2 were recorded.
Reef elevation appeared to provide some degree of protection from predators but differences in translocated M. modiolus survival on the different elevation treatments were not significant. In total, 223 taxa were recorded 12 months after reef construction. The presence of translocated clumps ofM. modiolus was the main driver of the increases in faunal diversity and species abundance. Application of objective criteria to assess the performance of artificial reefs suggested that translocation of M. modiolus clumps alone achieved most of the restoration objectives. Consequently this pilot study demonstrates a straightforward and realistic intervention technique that could be used to kick start the regeneration and expansion of impacted mussel and similar biogenic reefs elsewhere.
Resumo:
To determine the incidence of giant retinal tear (GRT) in the United Kingdom and to provide epidemiologic data, clinical characteristics, treatment methods, and short-term outcomes in affected and fellow eyes. METHODS. Patients with a newly developed GRT (90° or greater in circumferential extent associated with posterior vitreous detachment) were identified prospectively over a 13-month period (January 2007-January 2008, inclusive) by active surveillance through the British Ophthalmic Surveillance Unit. Questionnaire-based data were obtained from reporting ophthalmologists at baseline and 12 months. RESULTS. Sixty patients (62 eyes) developed a new GRT, giving a U.K. annual incidence of 0.094 (95% CI 0.072-0.120) cases or 0.091 (95% CI 0.069-0.117) patients per 100,000. The GRTs were mostly idiopathic (54.8%), affected middle-aged (mean, 42.2 years), white British (93.3%) males (71.7%), with presenting vision worse than 20/40 in 59.7%, foveal detachment in 45.2%, and proliferative vitreoretinopathy of grade C (PVR-C) or worse in 11.3%. Treatment in most was managed by pars plana vitrectomy (93.5%) with laser retinopexy (52.5%) and silicone oil endotamponade (75.8%). Prophylactic 360° laser or cryotherapy was applied to 39.0% of the fellow eyes. At mean follow-up of 11.3 months, eventual retinal reattachment was attained in 94.7%, although only 42.1% achieved vision of =20/40. Neither GRT nor RD developed in any of the 19 nontraumatic, noniatrogenic, prophylactically treated fellow eyes. CONCLUSIONS. This study is the first population-based prospective effort to evaluate the epidemiology of GRT. Although onlya minority presented with PVR-C and high retinal reattachment rates were achieved, fewer than half had vision sufficient for driving in the GRT eye.
Resumo:
Background: A giant retinal tear is a full-thickness retinal break that extends circumferentially around the retina for 90 degrees ormore in the presence of a posteriorly detached vitreous. It causes significant visual morbidity from retinal detachment and proliferative vitreoretinopathy. The fellow eye of patients who have had a spontaneous giant retinal tear has an increased risk of developing a giant retinal tear, a retinal detachment or both. Interventions such as 360-degree encircling scleral buckling, 360-degree cryotherapy and 360-degree laser photocoagulation have been advocated by some ophthalmologists as prophylaxis for the fellow eye against the development of a giant retinal tear and/or a retinal detachment, or to prevent its extension. Objectives: To evaluate the effectiveness of prophylactic 360-degree interventions in the fellow eye of patients with unilateral giant retinal tear to prevent the occurrence of a giant retinal tear and/or a retinal detachment. Search strategy: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2008, Issue 4), MEDLINE (January 1950 to December 2008), EMBASE (January 1980 to December 2008) and Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2008). In addition, we searched the proceedings of the Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO) up to 2008 for information about other relevant studies. There were no language or date restrictions in the search for trials. The electronic databases were last searched on 15 December 2008. Selection criteria: Prospective randomised controlled trials (RCTs) comparing one prophylactic treatment for fellow eyes of patients with giant retinal tear against observation (no treatment) or another form of prophylactic treatment. In the absence of RCTs, we planned to discuss case-control studies that met the inclusion criteria but we would not conduct a meta-analysis using these studies. Data collection and analysis: We did not find any studies that met the inclusion criteria for the review and therefore no assessment of methodological quality or meta-analysis could be performed. Main results: No studies met the inclusion criteria for this review. Authors' conclusions: No strong evidence in the literature was found to support or refute prophylactic 360-degree treatments to prevent a giant retinal tear or a retinal detachment in the fellow eye of patients with unilateral giant retinal tears. Copyright © 2009 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
Resumo:
Aim: To undertake a systematic review of the literature on the effect of environmental tobacco smoke (ETS) and eye disease. Methods: Medline (1950-January Week 2 2007), EMBASE (1980 to 2007 Week 07), SCOPUS and Science Direct were searched on ETS exposure and eye disease using various combinations of the following terms: passive smoking, environmental tobacco smoke, sidestream smoke, involuntary smoking, secondhand smoke; with eye, conjunctiva, sclera, episclera, cornea, lens, iris, retina, choroid, uvea, optic nerve, uveitis, iritis, blindness, visual loss, cataract, thyroid eye disease, conjunctivitis, age-related macular degeneration, dry eye, tears. The above terms were also used to search abstracts published on The Association for Research in Vision and Ophthalmology Annual Meeting abstracts, from 1995 to 2006, and the grey literature, including PhD and MSc theses/dissertations. A search was further conducted specifically on eye diseases where active smoking has been proposed to be a risk factor, including age-related macular degeneration, Graves ophthalmology, glaucoma, uveitis, refractive errors, strabismus, tobacco-alcohol amblyopia, non-arteritic ischaemic optic neuropathy, Leber optic neuropathy and diabetic retinopathy. Given the scarce number of studies found through the above search, all articles found on ETS and eye disease were included in this review. Results: Seven studies evaluated the possible relationship between ETS and an eye disease. These studies referred to refractive errors in children (n = 2), cataract (n = 1), age-related macular degeneration (n = 3) and Grave ophthalmopathy (n = 1). The data available were insufficient to establish conclusive relationships between ETS and these eye diseases. Conclusion: Very scarce data exist in the literature on the effect of ETS on diseases of the eye. It seems appropriate that ETS should be included in future studies addressing the effect of smoking on eye disease.
Resumo:
Endogenous electric fields (EF) have long been known to influence cell behaviour during development, neural cell tropism, wound healing and cell behaviour generally. The effect is based on short circuiting of electrical potential differences across cell and tissue boundaries generated by ionic segregation. Recent in vitro and in vivo studies have shown that EF regulate not only cell movement but orientation of cells during mitosis, an effect which may underlie shaping of tissues and organs. The molecular basis of this effect is founded on receptor-mediated cell signalling events and alterations in cytoskeletal function as revealed in studies of gene deficient cells. Remarkably, not all cells respond directionally to EF in the same way and this has consequences, for instance, for lens development and vascular remodelling. The physical basis of EF effect may be related to changes induced in 'bound water' at the cell surface, whose organisation in association with trans-membrane proteins (e.g. receptors) is disrupted when EF are generated. Copyright © 2007 S. Karger AG.
Resumo:
BACKGROUND: A giant retinal tear is a full-thickness retinal break that extends circumferentially around the retina for 90 degrees or more in the presence of a posteriorly detached vitreous. It causes significant visual morbidity from retinal detachment and proliferative vitreoretinopathy. The fellow eye of patients who have had a spontaneous giant retinal tear has an increased risk of developing a giant retinal tear, a retinal detachment or both. Interventions such as 360-degree encircling scleral buckling, 360-degree cryotherapy and 360-degree laser photocoagulation have been advocated by some ophthalmologists as prophylaxis for the fellow eye against the development of a giant retinal tear and/or a retinal detachment, or to prevent its extension. OBJECTIVES: To evaluate the effectiveness of prophylactic 360-degree interventions in the fellow eye of patients with unilateral giant retinal tear to prevent the occurrence of a giant retinal tear and/or a retinal detachment. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2008, Issue 4), MEDLINE (January 1950 to December 2008), EMBASE (January 1980 to December 2008) and Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2008). In addition, we searched the proceedings of the Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO) up to 2008 for information about other relevant studies. There were no language or date restrictions in the search for trials. The electronic databases were last searched on 15 December 2008. SELECTION CRITERIA: Prospective randomised controlled trials (RCTs) comparing one prophylactic treatment for fellow eyes of patients with giant retinal tear against observation (no treatment) or another form of prophylactic treatment. In the absence of RCTs, we planned to discuss case-control studies that met the inclusion criteria but we would not conduct a meta-analysis using these studies. DATA COLLECTION AND ANALYSIS: We did not find any studies that met the inclusion criteria for the review and therefore no assessment of methodological quality or meta-analysis could be performed. MAIN RESULTS: No studies met the inclusion criteria for this review. AUTHORS' CONCLUSIONS: No strong evidence in the literature was found to support or refute prophylactic 360-degree treatments to prevent a giant retinal tear or a retinal detachment in the fellow eye of patients with unilateral giant retinal tears.
Resumo:
A giant retinal tear is a full-thickness retinal break that extends circumferentially around the retina for 90 degrees or more in the presence of a posteriorly detached vitreous. It causes significant visual morbidity from retinal detachment and proliferative vitreoretinopathy. The fellow eye of patients who have had a spontaneous giant retinal tear has an increased risk of developing a giant retinal tear, a retinal detachment or both. Interventions such as 360-degree encircling scleral buckling, 360-degree cryotherapy and 360-degree laser photocoagulation have been advocated by some ophthalmologists as prophylaxis for the fellow eye against the development of a giant retinal tear and/or a retinal detachment, or to prevent its extension. To evaluate the effectiveness of prophylactic 360-degree interventions in the fellow eye of patients with unilateral giant retinal tear to prevent the occurrence of a giant retinal tear, a retinal detachment or both. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 11), MEDLINE (January 1950 to December 2011), EMBASE (January 1980 to December 2011), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2011), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 6 December 2011. In addition, we searched the proceedings of the Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO) up to 2008 for information about other relevant studies. Prospective randomised controlled trials (RCTs) comparing one prophylactic treatment for fellow eyes of patients with giant retinal tear against observation (no treatment) or another form of prophylactic treatment. In the absence of RCTs, we planned to discuss case-control studies that met the inclusion criteria but we would not conduct a meta-analysis using these studies. We did not find any studies that met the inclusion criteria for the review and therefore no assessment of methodological quality or meta-analysis could be performed. No studies met the inclusion criteria for this review. No strong evidence in the literature was found to support or refute prophylactic 360-degree treatments to prevent a giant retinal tear or a retinal detachment in the fellow eye of patients with unilateral giant retinal tears.
Resumo:
Frustration – the inability to simultaneously satisfy all interactions – occurs in a wide range of systems including neural networks, water ice and magnetic systems. An example of the latter is the so called spin-ice in pyrochlore materials [1] which have attracted a lot of interest not least due to the emergence of magnetic monopole defects when the ‘ice rules’ governing the local ordering breaks down [2]. However it is not possible to directly measure the frustrated property – the direction of the magnetic moments – in such spin ice systems with current experimental techniques. This problem can be solved by instead studying artificial spin-ice systems where the molecular magnetic moments are replaced by nanoscale ferromagnetic islands [3-8]. Two different arrangements of the ferromagnetic islands have been shown to exhibit spin ice behaviour: a square lattice maintaining four moments at each vertex [3,8] and the Kagome lattice which has only three moments per vertex but equivalent interactions between them [4-7]. Magnetic monopole defects have been observed in both types of lattices [7-8]. One of the challenges when studying these artificial spin-ice systems is that it is difficult to arrive at the fully demagnetised ground-state [6-8].
Here we present a study of the switching behaviour of building blocks of the Kagome lattice influenced by the termination of the lattice. Ferromagnetic islands of nominal size 1000 nm by 100 nm were fabricated in five island blocks using electron-beam lithography and lift-off techniques of evaporated 18 nm Permalloy (Ni80Fe20) films. Each block consists of a central island with four arms terminated by a different number and placement of ‘injection pads’, see Figure 1. The islands are single domain and magnetised along their long axis. The structures were grown on a 50 nm thick electron transparent silicon nitride membrane to allow TEM observation, which was back-coated with a 5 nm film of Au to prevent charge build-up during the TEM experiments.
To study the switching behaviour the sample was subjected to a magnetic field strong enough to magnetise all the blocks in one direction, see Figure 1. Each block obeys the Kagome lattice ‘ice-rules’ of “2-in, 1-out” or “1-in, 2-out” in this fully magnetised state. Fresnel mode Lorentz TEM images of the sample were then recorded as a magnetic field of increasing magnitude was applied in the opposite direction. While the Fresnel mode is normally used to image magnetic domain structures [9] for these types of samples it is possible to deduce the direction of the magnetisation from the Lorentz contrast [5]. All images were recorded at the same over-focus judged to give good Lorentz contrast.
The magnetisation was found to switch at different magnitudes of the applied field for nominally identical blocks. However, trends could still be identified: all the blocks with any injection pads, regardless of placement and number, switched the direction of the magnetisation of their central island at significantly smaller magnitudes of the applied magnetic field than the blocks without injection pads. It can therefore be concluded that the addition of an injection pad lowers the energy barrier to switching the connected island, acting as a nucleation site for monopole defects. In these five island blocks the defects immediately propagate through to the other side, but in a larger lattice the monopoles could potentially become trapped at a vertex and observed [10].
References
[1] M J Harris et al, Phys Rev Lett 79 (1997) p.2554.
[2] C Castelnovo, R Moessner and S L Sondhi, Nature 451 (2008) p. 42.
[3] R F Wang et al, Nature 439 (2006) 303.
[4] M Tanaka et al, Phys Rev B 73 (2006) 052411.
[5] Y Qi, T Brintlinger and J Cumings, Phys Rev B 77 (2008) 094418.
[6] E Mengotti et al, Phys Rev B 78 (2008) 144402.
[7] S Ladak et al, Nature Phys 6 (2010) 359.
[8] C Phatak et al, Phys Rev B 83 (2011) 174431.
[9] J N Chapman, J Phys D 17 (1984) 623.
[10] The authors gratefully acknowledge funding from the EPSRC under grant number EP/D063329/1.
Resumo:
The traditional training of surgeons focused exclusively on developing knowledge, clinical expertise, and technical (surgical) skills. However, analyses of the reasons for adverse events in surgery have revealed that many underlying causes originate from behavioural or non-technical aspects of performance (eg, poor communication among members of the surgical team) rather than from a lack of surgical (ie, technical) skills. Therefore, technical skills appear to be necessary but not sufficient to ensure patient safety. Paying attention to non-technical skills, such as team working, leadership, situation awareness, decision making, and communication, will increase the likelihood of maintaining high levels of error-free performance. Identification and training of non-technical skills has been developed for high-risk careers, such as civil aviation and nuclear power. Only recently, training in non-technical skills has been adopted by the surgical world and anaesthetists. Non-technical skills need to be tailored to the environment where they are used, and eye surgery has some substantial differences compared with other surgical areas, for example, high volume of surgery, use of local anaesthetics, and very sophisticated equipment. This review highlights the need for identification of the non-technical skills relevant to eye surgeons and promotion of their use in the training of eye surgeons.
Resumo:
Intertwining planar spirals arranged in doubly periodic arrays enables a substantially subwavelength response of the unit cell smaller than 1/40 of wavelength with large fractional bandwidths. These properties are important for application at low frequencies, conformal curved surfaces, or with compact radiators. It is shown that interleaving counter-wound spiral arms extended into adjacent unit cells dramatically increase the array equivalent capacitance while reducing the inductance. A coplanar waveguide (CPW) model has been developed to analytically estimate the equivalent capacitance and inductance of intertwined spiral array elements in terms of their geometrical parameters. The proposed CPW model is shown to provide an accurate prediction of the fundamental resonance frequency and can be instrumental in the design of the arrays for a specified frequency response. © 2012 IEEE.