954 resultados para Electron Microscope
Resumo:
The polyethylene terephthalate (PET) is used for package drugs and cosmetics. The aim of this research was examine by scanning electron microscopy (SEM) a Staphylococcus aureus attachment and biofilm formation on a polyethylene terephthalate (PET) surface and hydrophobicity of S. aureus by adherence to hydrocarbons. A suspension of S. aureus was prepared in Mueller-Hinton broth and, coupons of polyethylene terephthalate were incubated for 30 minutes, two, 24 and 48 hours, 15 and 30 days. Afteron the coupons were removed and prepared for scanning electron microscope analysis. The attachment and biofilm formation was observed on the surfaces of PET. The SEM revealed adhesion and biofilm formation on PET surfaces. The hydrophobicity test classified S. aureus as hydrophobic.
Resumo:
It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.
Resumo:
The objective of the present research was to investigate the ultrastructural peculiarities of the aortic wall of the rat. Seven young adult rats were used, from which fragments of the infrarenal abdominal aorta were collected. After collection, the vascular segments were fixed and sent for analysis by scanning electron microscope. The elastic lamellae appear interposed with smooth muscular fibers; this pattern was verified mainly at the medial layer structure. Among the mural elements a well defined interrelationship was established through connective lamellae of the arterial wall. The collagen lamellae mainly provided anchoring among the elastic and smooth muscular constituents. The intimal layer showed special ultrastructural features, such as a non-continuous inner elastic lamina presented in certain sites of the vascular wall, followed by endothelial pores. This mural pattern of the abdominal aorta provided support to vascular functions such as shrinkage among the laminar composition of the arterial layers, also acting in mechanical properties of the vascular wall, such as viscoelasticity and contractility - essential actions to blood vessel hemodynamics.
Resumo:
The Phrynops hilarii specie of turtle has its characterization not well defined in the literature, it was proposed in this study the leukocyte characterization of the blood, stained by Leishman and analyzed under light and transmission electron microscope. It was not observe any cellular type with similar characteristics to neutrophils in mammalian group. We believed, based on the data obtained in this study that the heterophils have a morphofuncional analogy with another neutrophils belonged to mammalian group. This conclusion is being supported in many recent studies found in the literature.
Resumo:
Aim: The aim of this study was to evaluate in situ, the early bacterial colonization on feldspar-ceramics submitted to different glazing. Methods and Materials: Fourteen standardized disc specimens (diameter: 5 mm, thickness: 1.5 mm) of each of two micro-particulate feldspathic ceramics (VM7 and VM13, Vita) were produced according to manufacturers' specifications for a total of 28 specimens (24 for the analysis of biofilm and 4 for topographic analysis analyzing the ceramic surfaces). Specimens from each type of ceramic were submitted to two different glazing methods composing four groups: VM7 glazed using glazing liquid Vita Akzent® 25 (G1) and glaze firing (G2), VM13 glazed using glazing liquid (G3) and glaze firing (G4). Six individuals (n=6) wore oral appliances with four ceramic specimens, fixed on the buccal face of the appliances. After 8 hours, each sample was evaluated for the presence (1) or absence (0) of bacterial colonization under a scanning electron microscope (SEM) on five randomly selected fields. The value for each sample was cumulative of the results observed in the fields. One sample from each group was evaluated under a SEM to verify the topographic pattern. Results: There was no difference with regard to bacterial colonization between the feldspar-ceramics and between the glazing types (Kruskal-Wallis non-parametric test). Conclusion: Feldspar-ceramics submitted to firing or glaze firing with Vita Akzent® 25 present a similar condition for in situ bacterial colonization. The similar topographic pattern of the ceramic surfaces seems to have influenced the bacterial colonization.
Resumo:
The purpose of this study was to investigate if experimental alloxanic diabetes could cause qualitative changes in intestinal anastomoses of the terminal ileum and distal colon in rats, as compared to controls. 192 male Wistar rats, weighing ± 300g were split into four experimental groups of 48 animals each, after 3 months of follow-up: a control group with ileum anastomoses (G1), a control group with colon anastomoses (G2), a diabetic group with ileum anastomoses (G3) and a diabetic group with colon anastomoses (G4). Animals were evaluated and sacrificed on days 4, 14, 21 and 30 after surgery, and fragments of the small and large intestine where the anastomoses were performed were removed. Samples from 6 animals from each sacrifice moment were submitted to ultrastructural analysis of the collagen fibers using a scanning electron microscope and samples from another 6 animals were submitted to histopathology and optical microscopy studies using picrosirius red-staining. Histopathological analysis of picrosirius red-stained anastomosis slides using an optical microscope at 40x magnification showed that the distribution of collagen fibers was disarranged and also revealed a delay in scar tissue retraction. The morphometric study revealed differences in the collagen filled area for the ileum anastomoses 14 days post surgery whereas, in the case of colon anastomoses, differences were observed at days 4 and 30 post surgery, with higher values in the diabetic animals. Ultrastructure analysis of the ileum and colon anastomoses using a scanning electron microscope revealed fewer wide collagen fibers, the presence of narrower fibers and a disarranged distribution of the collagen fibers. We conclude that diabetes caused qualitative changes in scar tissue as well as in the structural arrangement of collagen fibers, what could explain the reduced wound strength in the anastomosis of diabetic animals. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart.
Resumo:
The indwelling urethral catheter has an important role for patients with urinary retention, bladder obstruction, neurological damage and other diseases. Urine contains minerals which precipitate in alkaline pH, crystallize and block the urological catheter. The crystallization of the ionic components of urine occurs in the presence of urease, an enzyme produced by Proteus mirabilis. This bacterium adheres to inanimate surfaces and forms biofilms. The aim of this study was to investigate the formation of crystalline biofilm on the luminal surface of siliconized latex catheters by means of scanning electron microscope, after channeling artificial urine infected with Proteus mirabilis. The experiment was performed in vitro using a dynamic flow system. The artificial urine compounds were salts of calcium, magnesium, phosphates, urea and egg albumin, and it was infected with Proteus mirabilis ATCC 25933. The urine flow was stopped after crystallization of the ionic components. Crystallization was observed after alkalinization of urine. Scanning electron microscopy showed the presence of crystals and morphologies typical of bacilli embedded in an amorphous mass on the internal lumen of the catheter. The present study showed that catheter encrustation may limit the use of long-term indwelling catheter. © SBEB - Sociedade Brasileira de Engenharia Biomédica.
Resumo:
This study evaluated, by scanning electron microscope (SEM) and EDS, the effect of different strategies for silica coating (sandblasters, time and distance) of a glass-infiltrated ceramic (In-Ceram Alumina). Forty-one ceramic blocks were produced. For comparison of the three air-abrasion devices, 15 ceramic samples were divided in three groups (N.=5): Bioart, Microetcher and Ronvig (air-abrasion parameters: 20 s at a distance of 10 mm). For evaluation of the time and distance factors, ceramic samples (N.=5) were allocated in groups considering three applied times (5 s, 13 s and 20 s) and two distances (10 mm and 20 mm), using the Ronvig device. In a control sample, no surface treatment was performed. After that, the micro-morphologic analyzes of the ceramic surfaces were made using SEM. EDS analyzes were carried out to detect the % of silica on representative ceramic surface. ANOVA and Tukey tests were used to analyze the results. One-way ANOVA showed the silica deposition was different for different devices (P=0.0054). The Ronvig device promoted the highest silica coating compared to the other devices (Tukey test). Two-way ANOVA showed the distance and time factors did not affect significantly the silica deposition (application time and distance showed no statistical difference). The Ronvig device provided the most effective silica deposition on glass-infiltrated alumina ceramic surface and the studied time and distance for air-abrasion did not affect the silica coating.
Resumo:
This work presents the structural characterization of Ti-10Si-5B and Ti-20Si-10B (at-%) alloys produced by high-pressure assisted sintering. Sintering was performed in air at 1100 and 1200°C for 60 s using pressure levels of 5 GPa. Structural evaluation of sintered samples was conducted by means of scanning electron microscopy and energy dispersive spectrometry. Samples were successfully consolidated after sintering, which presented theoretical density values higher than 99%. The microstructures of the sintered Ti-10Si-5B and Ti-20Si-10B alloys revealed the presence of the TiSS, TiB, TiB2, Ti5Si3, Ti5Si4, TiSi, and TiSi2.phases. A small amount of Ti6Si2B was formed after high-pressure assisted sintering of the Ti-20Si-10B alloy (5GPa, 1100°C for 60 s) indicating that equilibrium structures were not achieved during short sintering times. No oxygen and carbon contamination was detected in structures of Ti-Si-B alloys after high-pressure sintering at 1100 and 1200°C without controlled atmosphere. © (2012) Trans Tech Publications, Switzerland.
Resumo:
The aim of this study was to evaluate the hardness, roughness and mass loss of an acrylic denture base resin after in vitro exposure to four disinfectant solutions. Forty specimens (Clássico, Brazil) were prepared and randomly assigned to 4 groups n = 10) according to the disinfectant solution: G1: control, stored in distilled water at 37 degrees C; G2: 1% sodium hypochlorite; G3: 2% glutaraldehyde; G4: 4% chlorhexidine. G2 to G4 were immersed for 60 minutes in the disinfectant solution. Measurements were carried out both before and after immersion in the solution. The surface was analyzed with a surface roughness tester (Surfcorder SE 1700 KOZAKALAB), a microdurometer FM-700 (Future Tech) and a scanning electron microscope (DSM 962-ZEISS). Loss of mass was determined with a digital weighing scale. After disinfection procedures, values were analyzed statistically. The acrylic denture base resin may be vulnerable to surface changes after in vitro immersion in the disinfectant solutions studied.
Resumo:
In this work, a silica surface chemically modified with [3-(2,2′-dipyridylamine)propyl] groups, named [3-(2,2′- dipyridylamine)propyl]silica (Si-Pr-DPA) was prepared, characterized, and evaluated for its heavy metal adsorption characteristics from aqueous solution. To our knowledge, we are the first authors who have reported the present modification. The material was characterized using infrared spectroscopy, SEM, and NMR 29Si and 13C solid state. Batch and column experiments were conducted to investigate for heavy metal removal from dilute aqueous solution by sorption onto Si-Pr-DPA. From a number of studies the affinity of various metal ions for the Si-Pr-DPA sorbent was determined to follow the order Fe(III) > Cr(III) >> Cu(II) > Cd(II) > Pb(II) > Ni(II). Two standard reference materials were used for checking the accuracy and precision of the method. The proposed method was successfully applied to the analysis of environmental samples. This ligand material has great advantage for adsorption of transition-metal ions from aqueous medium due to its high degree of organofunctionalization associated with the large adsorption capacity, reutilization possibility, and rapidity in reaching the equilibrium. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
A silica surface chemically modified with [3-(2,2'-dipyridylamine) propyl] groups was prepared, characterized, and evaluated for its metal ion preconcentration in fuel ethanol. To our knowledge, we are the first authors who have reported the present modification on silica gel surface. The material was characterized using infrared spectra, scanning electronic microscopy, and 13C and 29Si solid-state NMR spectra. Batch and column experiments were conducted to investigate for metal ion removal from fuel ethanol. The results showed that the Langmuir model describes the sorption equilibrium data of the metal ions in a satisfactory way. From the Langmuir isotherms, the following maximum adsorption capacities (in mmolg -1) were determined: 1.81 for Fe(III), 1.75 for Cr(III), 1.30 for Cu(II), 1.25 for Co(II), 1.15 for Pb(II), 0.95 for Ni(II), and 0.87 for Zn(II). Thermodynamic functions, the change of free energy (ΔG), enthalpy (ΔH), and entropy (ΔS) showed that the adsorption of metal ions onto Si-Pr-DPA was feasible, spontaneous, and endothermic. The sorption-desorption of the metal ions made possible the development of a preconcentration and quantification method of metal ions in fuel ethanol. © 2012 Elsevier Inc.
Resumo:
The purpose of this work was to evaluate the Ti-35Nb-7Zr experimental alloy after surface treatment and soaking in solution body fluid (SBF) to form bonelike apatite. The Ti-35Nb-7Zr alloy was produced from commercially pure materials (Ti, Nb and Zr) by an arc melting furnace. All ingots were submitted to sequences of heat treatment (1100 °C/2 h and water quenching), cold working by swaging procedures and heat treatment (1100 °C/2 h and water quenching). Discs with 13 mm diameter and 3 mm in thickness were cut. The samples were immersed in NaOH aqueous solution with 5 M at 60 °C for 72 h, washed with distilled water and dried at 40 °C for 24 h. After the alkaline treatment, samples were heat treated in both conditions: at 450 and 600 °C for 1 h in an electrical furnace in air. Then, they were soaking in SBF for 24 h to form an apatite layer on the surface. The surfaces were investigated by using scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), infrared spectroscopy (FTIR) and contact angle measurements. The results indicate that calcium phosphate could form on surface of Ti-35Nb-7Zr experimental alloy. © Springer-Verlag Berlin Heidelberg 2013.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The occurrence of a high incidence of sperm tail defects in a male domestic cat resembling the known 'Dag-like' defect is reported. Sperm analyses were performed in ejaculated samples collected by an artificial vagina and in testicular and epididymal sperm cells after castration. The following alterations were observed using transmission electron microscope: heavily coiled sperm tails containing several axonemal units enclosed in the same common cell membrane; aberrations in the axonemal main structure; and swollen and unevenly distributed mitochondria in the midpiece. Abnormal modifications in the mitochondrial sheath were also found in sperm cells retrieved from testes and epididymides. Considering these findings, we can conclude that this is the Dag-like defect, described previously in other domestic species and a testicular origin may be involved. © ISFM and AAFP 2012.