985 resultados para Electrical signal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potential impacts of electrical capacity market design on capacity mobility and end use customer pricing are analyzed. Market rules and historical evolution are summarized to provide a background for the analysis. The summarized rules are then examined for impacts on capacity mobility. A summary of the aspects of successful capacity markets is provided. Two United States market regions are chosen for analysis based upon their market history and proximity to each other. The MISO region is chosen due to recent developments in capacity market mechanisms. The PJM region neighbors the MISO region and is similar in size and makeup. The PJM region has had a capacity market mechanism for over a decade and allows for a controlled comparison of the MISO region’s developments. Capacity rules are found to have an impact on the mobility of capacity between regions. Regulatory restrictions and financial penalties for the movement of capacity between regions are found which effectively hinder such mobility. Capacity market evolution timelines are formed from the historical evolution previously summarized and compared to historical pricing to inspect for a correlation. No direct and immediate impact on end use customer pricing was found due to capacity market design. The components of end use customer pricing are briefly examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to modulate the secretion of insulin and glucagon in Beagle dogs by stimulation of nerves innervating the intact and partly dysfunctional pancreas. Three 33-electrode spiral cuffs were implanted on the vagus, splanchnic and pancreatic nerves in each of two animals. Partial dysfunction of the pancreas was induced with alloxan. The nerves were stimulated using rectangular, charge-balanced, biphasic, and constant current pulses (200 µs, 1 mA, 20 Hz, with a 100-µs delay between biphasic phases). Blood samples from the femoral artery were drawn before the experiment, at the beginning of stimulation, after 5 min of stimulation, and 5 min after the end of stimulation. Radioimmunoassay data showed that in the intact pancreas stimulation of the vagal nerve increased insulin (+99.2 µU/ml) and glucagon (+18.7 pg/ml) secretion and decreased C-peptide secretion (-0.15 ng/ml). Splanchnic nerve stimulation increased insulin (+1.7 µU/ml), C-peptide (+0.01 ng/ml), and glucagon (+50 pg/ml) secretion, whereas pancreatic nerve stimulation did not cause a marked change in any of the three hormones. In the partly dysfunctional pancreas, vagus nerve stimulation increased insulin (+15.5 µU/ml), glucagon (+11 pg/ml), and C-peptide (+0.03 ng/ml) secretion. Splanchnic nerve stimulation reduced insulin secretion (-2.5 µU/ml) and increased glucagon (+58.7 pg/ml) and C-peptide (+0.39 ng/ml) secretion, and pancreatic nerve stimulation increased insulin (+0.2 µU/ml), glucagon (+5.2 pg/ml), and C-peptide (+0.08 ng/ml) secretion. It was concluded that vagal nerve stimulation can significantly increase insulin secretion for a prolonged period of time in intact and in partly dysfunctional pancreas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energian kulutuksen vähentäminen ja sen tutkiminen on kasvavan kiinnostuksen kohteena. Syntyneen lämmön mittaaminen on yksi tapa mitata energian siirtymistä. Lämpötilan mittaaminen on yleistä, vaikka usein on merkittävämpää selvittää missä ja miten lämpöenergia on siirtynyt. Tästä syystä tarvitaan lämpövuoantureita, jotka reagoivat suoraan lämpövuohon eli lämpöenergian siirtymiseen. Tässä tutkimuksessa suunnitellaan ja toteutetaan lämpövuoanturin mittauselektroniikka vaativaan käyttöympäristöön. Työssä käytettävän gradienttilämpövuoanturin tuottama jännitesignaali on mikrovolttiluokkaa ja ympäristön aiheuttama kohina voi olla huomattavasti suurempi. Tämän takia anturin tuottamaa signaalia on vahvistettava, jotta sitä voidaan mitata luotettavasti. Tutkimuksessa keskitytään vahvistimen suunnitteluun, mutta suunnittelussa on otettava huomioon koko järjestelmä. Anturin sähköiset ominaisuudet ja ympäristö asettavat rajoitteita vahvistimelle. Tavoitteena on selvittää miten voidaan mitata mikrovolttien jännitesignaalia mahdollisimman suurella taajuuskaistalla vaativassa käyttöympäristössä. Työn tuloksena syntyi mittalaite, jota voidaan käyttää vaativassa ympäristössä lämpövuon mittaamiseen. Suunnitteluparametrien mukainen vahvistus ja päästökaista sekä offset-jännitteen ryömintä saavutettiin suunnitellulla mittalaitteella, mutta offsetjännite ja kohina olivat hieman suunniteltua suuremmat. Mittalaitteella ja lämpövuoanturilla havaittiin selvästi lämpövuon muutoksia keinotekoisilla herätteillä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesial temporal lobe epilepsy (MTLE) is associated with hippocampal atrophy and hippocampal signal abnormalities. In our series of familial MTLE (FMTLE), we found a high proportion of hippocampal abnormalities. To quantify signal abnormalities in patients with FMTLE we studied 152 individuals (46 of them asymptomatic) with FMTLE. We used NIH-Image® for volumetry and signal quantification in coronal T1 inversion recovery and T2 for all cross-sections of the hippocampus. Values diverging by 2 or more SD from the control mean were considered abnormal. T2 hippocampal signal abnormalities were found in 52% of all individuals: 54% of affected subjects and 48% of asymptomatic subjects. T1 hippocampal signal changes were found in 34% of all individuals: 42.5% of affected subjects and 15% of asymptomatic subjects. Analysis of the hippocampal head (first three slices) revealed T2 abnormalities in 73% of all individuals (74% of affected subjects and 72% of asymptomatic subjects) and T1 abnormalities in 59% (67% of affected subjects and 41% of asymptomatic subjects). Affected individuals had smaller volumes than controls (P < 0.0001). There was no difference in hippocampal volumes between asymptomatic subjects and controls, although 39% of asymptomatic patients had hippocampal atrophy. Patients with an abnormal hippocampal signal (133 individuals) had smaller ipsilateral volume, but no linear correlation could be determined. Hippocampal signal abnormalities in FMTLE were more frequently found in the hippocampal head in both affected and asymptomatic family members, including those with normal volumes. These results indicate that subtle abnormalities leading to an abnormal hippocampal signal in FMTLE are not necessarily related to seizures and may be determined by genetic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To inhibit an ongoing flow of thoughts or actions has been largely considered to be a crucial executive function, and the stop-signal paradigm makes inhibitory control measurable. Stop-signal tasks usually combine two concurrent tasks, i.e., manual responses to a primary task (go-task) are occasionally countermanded by a stimulus which signals participants to inhibit their response in that trial (stop-task). Participants are always instructed not to wait for the stop-signal, since waiting strategies cause the response times to be unstable, invalidating the data. The aim of the present study was to experimentally control the strategies of waiting deliberately for the stop-signal in a stop-task by means of an algorithm that measured the variation in the reaction times to go-stimuli on-line, and displayed a warning legend urging participants to be faster when their reaction times were more than two standard deviations of the mean. Thirty-four university students performed a stop-task with go- and stop-stimuli, both of which were delivered in the visual modality and were lateralized within the visual field. The participants were divided into two groups (group A, without the algorithm, vs group B, with the algorithm). Group B exhibited lower variability of reaction times to go-stimuli, whereas no significant between-group differences were found in any of the measures of inhibitory control, showing that the algorithm succeeded in controlling the deliberate waiting strategies. Differences between deliberate and unintentional waiting strategies, and anxiety as a probable factor responsible for individual differences in deliberate waiting behavior, are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have shown that saccadic eye responses but not manual responses were sensitive to the kind of warning signal used, with visual onsets producing longer saccadic latencies compared to visual offsets. The aim of the present study was to determine the effects of distinct warning signals on manual latencies and to test the premise that the onset interference, in fact, does not occur for manual responses. A second objective was to determine if the magnitude of the warning effects could be modulated by contextual procedures. Three experimental conditions based on the kind of warning signal used (visual onset, visual offset and auditory warning) were run in two different contexts (blocked and non-blocked). Eighteen participants were asked to respond to the imperative stimulus that would occur some milliseconds (0, 250, 500 or 750 ms) after the warning signal. The experiment consisted in three experimental sessions of 240 trials, where all the variables were counterbalanced. The data showed that visual onsets produced longer manual latencies than visual offsets in the non-blocked context (275 vs 261 ms; P < 0.001). This interference was obtained, however, only for short intervals between the warning and the stimulus, and was abolished when the blocked context was used (256 vs 255 ms; P = 0.789). These results are discussed in terms of bottom-up and top-down interactions, mainly those related to the role of attentional processing in canceling out competitive interactions and suppressive influences of a distractor on the relevant stimulus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

T84 is an established cell line expressing an enterocyte phenotype whose permeability properties have been widely explored. Osmotic permeability (P OSM), hydraulic permeability (P HYDR) and transport-associated net water fluxes (J W-transp), as well as short-circuit current (I SC), transepithelial resistance (R T), and potential difference (deltaV T) were measured in T84 monolayers with the following results: P OSM 1.3 ± 0.1 cm.s-1 x 10-3; P HYDR 0.27 ± 0.02 cm.s-1; R T 2426 ± 109 omega.cm², and deltaV T 1.31 ± 0.38 mV. The effect of 50 µM 5,6-dichloro-1-ethyl-1,3-dihydro-2H-benzimidazol-2-one (DCEBIO), a "net Cl- secretory agent", on T84 cells was also studied. We confirm the reported important increase in I SC induced by DCEBIO which was associated here with a modest secretory deltaJ W-transp. The present results were compared with those reported using the same experimental approach applied to established cell lines originating from intestinal and renal epithelial cells (Caco-2, LLC-PK1 and RCCD-1). No clear association between P HYDR and R T could be demonstrated and high P HYDR values were observed in an electrically tight epithelium, supporting the view that a "water leaky" barrier is not necessarily an "electrically leaky" one. Furthermore, the modest secretory deltaJ W-transp was not consistent with previous results obtained with RCCD-1 cells stimulated with vasopressin (absorptive fluxes) or with T84 cells secreting water under the action of Escherichia coli heat stable enterotoxin. We conclude that, while the presence of aquaporins is necessary to dissipate an external osmotic gradient, coupling between water and ion transport cannot be explained by a simple and common underlying mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Permanent magnet materials are nowadays widely used in the electrical machine manufacturing industry. Eddy current loss models of permanent magnets used in electrical machines are frequently discussed in research papers. In magnetic steel materials we have, in addition to eddy current losses, hysteresis losses when AC or a rotating flux travels through the material. Should a similar phenomenon also be taken into account in calculating the losses of permanent magnets? Actually, every now and then authors seem to assume that some significant hysteresis losses are present in rotating machine PMs. This paper studies the mechanisms of possible hysteresis losses in PMs and their role in PMs when used in rotating electrical machines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical machines have significant improvement potential. Nevertheless, the field is characterized by incremental innovations. Admittedly, steady improvement has been achieved, but no breakthrough development. Radical development in the field would require the introduction of new elements, such that may change the whole electrical machine industry system. Recent technological advancements in nanomaterials have opened up new horizons for the macroscopic application of carbon nanotube (CNT) fibres. With values of 100 MS/m measured on individual CNTs, CNT fibre materials hold promise for conductivities far beyond those of metals. Highly conductive, lightweight and strong CNT yarn is finally within reach; it could replace copper as a potentially better winding material. Although not yet providing low resistivity, the newest CNT yarn offers attractive perspectives for accelerated efficiency improvement of electrical machines. In this article, the potential for using new CNT materials to replace copper in machine windings is introduced. It does so, firstly, by describing the environment for a change that could revolutionize the industry and, secondly, by presenting the breakthrough results of a prototype construction. In the test motor, which is to our knowledge the first in its kind, the presently most electrically conductive carbon nanotube yarn replaces usual copper in the windings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis and its consequent fractures are a great social and medical problem mainly occurring in post-menopausal women. Effective forms of prevention and treatment of osteoporosis associated with lower costs and the least side effects are needed. Electrical fields are able to stimulate osteogenesis in fractures, but little is known about their action on osteoporotic tissue. The aim of the present study was to determine by bone densitometry the effects of electrical stimulation on ovariectomized female Wistar rats. Thirty rats (220 ± 10 g) were divided into three groups: sham surgery (SHAM), bilateral ovariectomy (OVX) and bilateral ovariectomy + electrical stimulation (OVX + ES). The OVX + ES group was submitted to a 20-min session of a low-intensity pulsed electrical field (1.5 MHz, 30 mW/cm²) starting on the 7th day after surgery, five times a week (total = 55 sessions). Global, spine and limb bone mineral density were measured by dual-energy X-ray absorptiometry (DXA Hologic 4500A) before surgery and at the end of protocol (84 days after surgery). Electrical stimulation improved (P < 0.05) global (0.1522 ± 0.002), spine (0.1502 ± 0.003), and limb (0.1294 ± 0.003 g/cm²) bone mineral density compared to OVX group (0.1447 ± 0.001, 0.1393 ± 0.002, and 0.1212 ± 0.001, respectively). The OVX + ES group also showed significantly higher global bone mineral content (9.547 ± 0.114 g) when compared to both SHAM (8.693 ± 0.165 g) and OVX (8.522 ± 0.207 g) groups (P < 0.05). We have demonstrated that electrical fields stimulate osteogenesis in ovariectomized female rats. Their efficacy in osteoporosis remains to be demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces an important source of torque ripple in PMSMs with tooth-coil windings (TC-PMSMs). It is theoretically proven that saturation and cross-saturation phenomena caused by the non-synchronous harmonics of the stator current linkage cause a synchronous inductance variation with a particular periodicity. This, in turn, determines the magnitude of the torque ripple and can also deteriorate the performance of signal-injection-based rotor position estimation algorithms. An improved dq- inductance model is proposed. It can be used in torque ripple reduction control schemes and can enhance the self-sensing capabilities of TC-PMSMs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to assess the effect of transcutaneous electrical diaphragmatic stimulation (TEDS) on different types of diaphragm muscle fibers. Male Wistar rats (8-12 weeks old) were divided into 2 experimental groups (N = 8 in each group): 1) control, 2) animals submitted to TEDS [frequency = 50 Hz; T ON/T OFF (contraction/relaxation time) = 2/2 s; pulse duration = 0.4 ms, intensity = 5 mA with a 1 mA increase every 3 min for 20 min] for 7 days. After completing this treatment period, the I, IIA, IIB, and IID diaphragm muscle fibers were identified using the mATPase technique. Statistical analysis consisted of the normality, homoscedasticity and t-tests (P < 0.05). There was a 19.6% (P < 0.05) reduction in the number of type I fibers and a 49.7% increase (P < 0.05) in type IID fibers in the TEDS group compared with the control group. An important result of the present study was that electrical stimulation with surface electrodes was efficient in altering the distribution of fibers in diaphragm muscle. This therapeutic resource could be used in the treatment of respiratory muscle alterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical stimulation of baroreceptor afferents was used in the 1960's in several species, including human beings, for the treatment of refractory hypertension. This approach bypasses the site of baroreceptor mechanosensory transduction. Chronic electrical stimulation of arterial baroreceptors, particularly of the carotid sinus nerve (Hering's nerve), was proposed as an ultimate effort to treat refractory hypertension and angina pectoris due to the limited nature of pharmacological therapy available at that time. Nevertheless, this approach was abandoned in the early 1970's due to technical limitations of implantable devices and to the development of better-tolerated antihypertensive medications. More recently, our laboratory developed the technique of electrical stimulation of the aortic depressor nerve in conscious rats, enabling access to hemodynamic responses without the undesirable effect of anesthesia. In addition, electrical stimulation of the aortic depressor nerve allows assessment of the hemodynamic responses and the sympathovagal balance of the heart in hypertensive rats, which exhibit a well-known decrease in baroreflex sensitivity, usually attributed to baroreceptor ending dysfunction. Recently, there has been renewed interest in using electrical stimulation of the carotid sinus, but not the carotid sinus nerve, to lower blood pressure in conscious hypertensive dogs as well as in hypertensive patients. Notably, previous undesirable technical outcomes associated with electrical stimulation of the carotid sinus nerve observed in the 1960's and 1970's have been overcome. Furthermore, promising data have been recently reported from clinical trials that evaluated the efficacy of carotid sinus stimulation in hypertensive patients with drug resistant hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The matrix metalloprotease-1 (MMP-1)/protease-activated receptor-1 (PAR-1) signal transduction axis plays an important role in tumorigenesis. To explore the expression and prognostic value of MMP-1 and PAR-1 in esophageal squamous cell carcinoma (ESCC), we evaluated the expression of two proteins in resected specimens from 85 patients with ESCC by immunohistochemistry. Sixty-two (72.9%) and 58 (68.2%) tumors were MMP-1- and PAR-1-positive, respectively, while no significant staining was observed in normal esophageal squamous epithelium. MMP-1 and PAR-1 overexpression was significantly associated with tumor node metastasis (TNM) stage and regional lymph node involvement. Patients with MMP-1- and PAR-1-positive tumors, respectively, had poorer disease-free survival (DFS) than those with negative ESCC (P = 0.002 and 0.003, respectively). Univariate analysis showed a significant relationship between TNM stage [hazard ratio (HR) = 2.836, 95% confidence interval (CI) = 1.866-4.308], regional lymph node involvement (HR = 2.955, 95%CI = 1.713-5.068), MMP-1 expression (HR = 2.669, 95%CI = 1.229-6.127), and PAR-1 expression (HR = 1.762, 95%CI = 1.156-2.883) and DFS. Multivariate analysis including the above four parameters identified TNM stage (HR = 2.035, 95%CI = 1.167-3.681), MMP-1 expression (HR = 2.109, 95%CI = 1.293-3.279), and PAR-1 expression (HR = 1.967, 95%CI = 1.256-2.881) as independent and significant prognostic factors for DFS. Our data suggest for the first time that MMP-1 and PAR-1 were both overexpressed in ESCC and are novel predictors of poor patient prognosis after curative resection. The MMP-1/PAR-1 signal transduction axis might be a new therapeutic target for future therapies tailored against ESCC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SEARCH-RIO study prospectively investigated electrocardiogram (ECG)-derived variables in chronic Chagas disease (CCD) as predictors of cardiac death and new onset ventricular tachycardia (VT). Cardiac arrhythmia is a major cause of death in CCD, and electrical markers may play a significant role in risk stratification. One hundred clinically stable outpatients with CCD were enrolled in this study. They initially underwent a 12-lead resting ECG, signal-averaged ECG, and 24-h ambulatory ECG. Abnormal Q-waves, filtered QRS duration, intraventricular electrical transients (IVET), 24-h standard deviation of normal RR intervals (SDNN), and VT were assessed. Echocardiograms assessed left ventricular ejection fraction. Predictors of cardiac death and new onset VT were identified in a Cox proportional hazard model. During a mean follow-up of 95.3 months, 36 patients had adverse events: 22 new onset VT (mean±SD, 18.4±4‰/year) and 20 deaths (26.4±1.8‰/year). In multivariate analysis, only Q-wave (hazard ratio, HR=6.7; P<0.001), VT (HR=5.3; P<0.001), SDNN<100 ms (HR=4.0; P=0.006), and IVET+ (HR=3.0; P=0.04) were independent predictors of the composite endpoint of cardiac death and new onset VT. A prognostic score was developed by weighting points proportional to beta coefficients and summing-up: Q-wave=2; VT=2; SDNN<100 ms=1; IVET+=1. Receiver operating characteristic curve analysis optimized the cutoff value at >1. In 10,000 bootstraps, the C-statistic of this novel score was non-inferior to a previously validated (Rassi) score (0.89±0.03 and 0.80±0.05, respectively; test for non-inferiority: P<0.001). In CCD, surface ECG-derived variables are predictors of cardiac death and new onset VT.