890 resultados para Electrical load
Resumo:
The study reported presents the findings relating to commercial growing of genetically-modified Bt cotton in South Africa by a large sample of smallholder farmers over three seasons (1998/99, 1999/2000, 2000/01) following adoption. The analysis presents constructs and compares groupwise differences for key variables in Bt v. non-Bt technology and uses regressions to further analyse the production and profit impacts of Bt adoption. Analysis of the distribution of benefits between farmers due to the technology is also presented. In parallel with these socio-economic measures, the toxic loads being presented to the environment following the introduction of Bt cotton are monitored in terms of insecticide active ingredient (ai) and the Biocide Index. The latter adjusts ai to allow for differing persistence and toxicity of insecticides. Results show substantial and significant financial benefits to smallholder cotton growers of adopting Bt cotton over three seasons in terms of increased yields, lower insecticide spray costs and higher gross margins. This includes one particularly wet, poor growing season. In addition, those with the smaller holdings appeared to benefit proportionately more from the technology (in terms of higher gross margins) than those with larger holdings. Analysis using the Gini-coefficient suggests that the Bt technology has helped to reduce inequality amongst smallholder cotton growers in Makhathini compared to what may have been the position if they had grown conventional cotton. However, while Bt growers applied lower amounts of insecticide and had lower Biocide Indices (per ha) than growers of non-Bt cotton, some of this advantage was due to a reduction in non-bollworm insecticide. Indeed, the Biocide Index for all farmers in the population actually increased with the introduction of Bt cotton. The results indicate the complexity of such studies on the socio-economic and environmental impacts of GM varieties in the developing world.
Resumo:
This paper provides an extended analysis of the child labor problem in the artisanal and small-scale mining (ASM) sector, focusing specifically on the situation in sub-Saharan Africa. In recent years, the issue of child labor in ASM has garnered significant attention from the International Labor Organization (ILO), which has been particularly active in raising public awareness of the problem; and, has proceeded to implement policies and collaborative project work aimed at Curtailing children's participation in ASM activities in a number of African countries. The analysis concludes with a critical appraisal of an ILO project recently launched in the Talensi-Nabdam District in the Upper East Region of Ghana, which sheds light on how the child labor problem is being tackled in practice in ASM communities in sub-Saharan Africa. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Varicella-zoster virus (VZV) is a member of the Herpesviridae family, primary infection with which causes varicella, more commonly known as chicken pox. Characteristic of members of the alphaherpesvirus subfamily, VZV is neurotropic and establishes latency in sensory neurons. Reactivation of VZV causes herpes zoster, also known as shingles. The most frequent complication following zoster is chronic and often debilitating pain called postherpetic neuralgia (PHN), which can last for months after the disappearance of a rash. During episodes of acute zoster, VZV viremia occurs in some, but not all, patients; however, the effect of the viral load on the disease outcome is not known. Here we describe the development of a highly specific, sensitive, and reproducible real-time PCR assay to investigate the factors that may contribute to the presence and levels of baseline viremia in patients with zoster and to determine the relationship between viremia and the development and persistence of PHN. VZV DNA was detected in the peripheral blood mononuclear cells (PBMCs) of 78% of patients with acute zoster and in 9% of healthy asymptomatic blood donors. The presence of VZV in the PBMCs of patients with acute zoster was independently associated with age and being on antivirals but not with gender, immune status, extent of rash, the age of the rash at the time of blood sampling, having a history of prodromal pain, or the extent of acute pain. Prodromal pain was significantly associated with higher baseline viral loads. Viral load levels were not associated with the development or persistence of PHN at 6, 12, or 26 weeks.
Resumo:
Coxsackievirus B3 (CVB3) infection can result in myocarditis, which in turn may lead to a protracted immune response and subsequent dilated cardiomyopathy. Human decay-accelerating factor (DAF), a binding receptor for CVB3, was synthesized as a soluble IgG1-Fc fusion protein (DAF-Fc). In vitro, DAF-Fc was able to inhibit complement activity and block infection by CVB3, although blockade of infection varied widely among strains of CVB3. To determine the effects of DAF-Fc in vivo, 40 adolescent A/J mice were infected with a myopathic strain of CVB3 and given DAF-Fc treatment 3 days before infection, during infection, or 3 days after infection; the mice were compared with virus alone and sham-infected animals. Sections of heart, spleen, kidney, pancreas, and liver were stained with hematoxylin and eosin and submitted to in situ hybridization for both positive-strand and negative-strand viral RNA to determine the extent of myocarditis and viral infection, respectively. Salient histopathologic features, including myocardial lesion area, cell death, calcification and inflammatory cell infiltration, pancreatitis, and hepatitis were scored without knowledge of the experimental groups. DAF-Fc treatment of mice either preceding or concurrent with CVB3 infection resulted in a significant decrease in myocardial lesion area and cell death and a reduction in the presence of viral RNA. All DAF-Fc treatment groups had reduced infectious CVB3 recoverable from the heart after infection. DAF-Fc may be a novel therapeutic agent for active myocarditis and acute dilated cardiomyopathy if given early in the infectious period, although more studies are needed to determine its mechanism and efficacy.
Resumo:
Commercial dodecylbenzene cable fluid was aged at temperatures of 105 and 135 degrees C in dry oxygen-free nitrogen. In addition, selected samples were aged at 135 degrees C under sealed conditions where air was excluded from the headspace above the oil. A variety of analytical techniques, such as ultra-violet visible and infra-red spectroscopy, acid number and water content measurements, were then used to characterize the aged oils. In addition, their electrical properties were assessed by dielectric spectroscopy. Compared with ageing in air, the ageing rate was reduced significantly and, as expected, no major oxidation peaks were detected in the infrared spectrometer. Significantly, very little absorbance at 680 nm ("red absorbers") was detected in samples aged with copper and, consequentially, no large increases in dielectric loss were recorded within the ageing times considered here. This study compliments previous investigations on cable fluid and 1-phenyldodecane aged in air and show that the same ageing indicators are valid in oils aged under conditions which more closely resemble those found in high voltage plant.
Resumo:
A commercial dodecylbenzene (DDB) cable oil was aged at temperatures between 90 and 135 degrees C in air and was analyzed using various analytical techniques including optical and infra-red spectroscopy and dielectric analysis. On ageing, the oil darkened, significant oxidation features were found by infra-red spectroscopy and the acid number, water content and dielectric loss all increased. Ageing in the presence of paper or aluminum did not affect the ageing process, whereas ageing was significantly modified by the presence of copper. An absorption at 680 nm ("red absorbers") was detected by ultra-violet/visible spectroscopy followed by the production of an opaque precipitate. A reaction between copper and the acid generated on ageing is thought to produce copper carboxylates, and X-ray fluorescence confirmed that copper was indeed present in both the aged oil and the precipitate. Significantly, once red absorbers were detected, the dielectric loss increased to catastrophically high values and, therefore, the appearance of these compounds may serve as a useful diagnostic indicator. The development of acidity on ageing appears to be key in initiating the destructive copper conversion reaction and hence the control of oil acidity may be key to prolonging the life of DDB cable oils.
Resumo:
The linear isomer of dodecylbenzene (DDB), 1-phenyldodecane, was aged at temperatures of 105 and 135 degrees C in air and the resultant products were analyzed using a range of analytical techniques. On ageing, the 1-phenyldodecane darkened, the acid number, dielectric loss and water content increased and significant oxidation peaks were detected in the infrared spectrum. When aged in the presence of copper, a characteristic peak at 680 nm was also detected by UV/visible spectroscopy but, compared with previous studies of a cable-grade DDB, the strength of this peak was much increased and no appreciable precipitate formation occurred. At the same time, very high values of dielectric loss were recorded. On ageing in the absence of copper, an unusually strong infrared carbonyl band was seen, which correlates well with the detection of dodecanophenone by gas chromatography / mass spectrometry and nuclear magnetic resonance spectroscopy. It was therefore concluded that the ageing process proceeds via the initial production of aromatic ketones, which may then be further oxidized to carboxylic acids. In the presence of copper, these oxidation products are present in lower quantities, most of these oxidation products being combined with the copper present in the oil to give copper carboxylates. The behavior is described in terms of a complex autoxidation mechanism, in which copper acts as both an oxidizing and a reducing agent, depending on its oxidation state and, in particular, promotes elimination via the oxidation of intermediate alkyl radical species to carbocations.
Resumo:
An indoor rowing machine has been modified for functional electrical stimulation (FES) assisted rowing exercise in paraplegia. To perform the rowing manoeuvre successfully, however, the voluntarily controlled upper body movements must be co-ordinated with the movements of the electrically stimulated paralysed legs. To achieve such co-ordination, an automatic FES controller was developed that employs two levels of hierarchy. At the upper level, a finite state controller identifies the state or phase of the rowing cycle and activates the appropriate lower-level controller, in which electrical stimulation to the paralysed leg muscles is applied with reference to switching curves representing the desired seat velocity as a function of the seat position. In a pilot study, the hierarchical control of FES rowing was shown to be intuitive, reliable and easy to use. Compared with open-loop control of stimulation, all three variants of the closed-loop switching curve controllers used less muscle stimulation per rowing cycle (73% of the open-loop control on average). Further, the closed-loop controller that used switching curves derived from normal rowing kinematics used the lowest muscle stimulation (65% of the open-loop control) and was the most convenient to use for the client.
Resumo:
Objectives. Theoretic modeling and experimental studies suggest that functional electrical stimulation (FES) can improve trunk balance in spinal cord injured subjects. This can have a positive impact on daily life, increasing the volume of bimanual workspace, improving sitting posture, and wheelchair propulsion. A closed loop controller for the stimulation is desirable, as it can potentially decrease muscle fatigue and offer better rejection to disturbances. This paper proposes a biomechanical model of the human trunk, and a procedure for its identification, to be used for the future development of FES controllers. The advantage over previous models resides in the simplicity of the solution proposed, which makes it possible to identify the model just before a stimulation session ( taking into account the variability of the muscle response to the FES). Materials and Methods. The structure of the model is based on previous research on FES and muscle physiology. Some details could not be inferred from previous studies, and were determined from experimental data. Experiments with a paraplegic volunteer were conducted in order to measure the moments exerted by the trunk-passive tissues and artificially stimulated muscles. Data for model identification and validation also were collected. Results. Using the proposed structure and identification procedure, the model could adequately reproduce the moments exerted during the experiments. The study reveals that the stimulated trunk extensors can exert maximal moment when the trunk is in the upright position. In contrast, previous studies show that able-bodied subjects can exert maximal trunk extension when flexed forward. Conclusions. The proposed model and identification procedure are a successful first step toward the development of a model-based controller for trunk FES. The model also gives information on the trunk in unique conditions, normally not observable in able-bodied subjects (ie, subject only to extensor muscles contraction).
Resumo:
Mitochondrial DNA (mtDNA) mutations are an important cause of genetic disease and have been proposed to play a role in the ageing process. Quantification of total mtDNA mutation load in ageing tissues is difficult as mutational events are rare in a background of wild-type molecules, and detection of individual mutated molecules is beyond the sensitivity of most sequencing based techniques. The methods currently most commonly used to document the incidence of mtDNA point mutations in ageing include post-PCR cloning, single-molecule PCR and the random mutation capture assay. The mtDNA mutation load obtained by these different techniques varies by orders of magnitude, but direct comparison of the three techniques on the same ageing human tissue has not been performed. We assess the procedures and practicalities involved in each of these three assays and discuss the results obtained by investigation of mutation loads in colonic mucosal biopsies from ten human subjects.
Resumo:
Evidence is emerging for physical links among clouds, global temperatures, the global atmospheric electrical circuit and cosmic ray ionisation. The global circuit extends throughout the atmosphere from the planetary surface to the lower layers of the ionosphere. Cosmic rays are the principal source of atmospheric ions away from the continental boundary layer: the ions formed permit a vertical conduction current to flow in the fair weather part of the global circuit. Through the (inverse) solar modulation of cosmic rays, the resulting columnar ionisation changes may allow the global circuit to convey a solar influence to meteorological phenomena of the lower atmosphere. Electrical effects on non-thunderstorm clouds have been proposed to occur via the ion-assisted formation of ultra-fine aerosol, which can grow to sizes able to act as cloud condensation nuclei, or through the increased ice nucleation capability of charged aerosols. Even small atmospheric electrical modulations on the aerosol size distribution can affect cloud properties and modify the radiative balance of the atmosphere, through changes communicated globally by the atmospheric electrical circuit. Despite a long history of work in related areas of geophysics, the direct and inverse relationships between the global circuit and global climate remain largely quantitatively unexplored. From reviewing atmospheric electrical measurements made over two centuries and possible paleoclimate proxies, global atmospheric electrical circuit variability should be expected on many timescales
Resumo:
The atmospheric electrical Potential Gradient (PG) arises from global thunderstorm activity, but surface measurements of the atmospheric Potential Gradient (PG) are influenced by global thunderstorms and local aerosol concentration changes. The local aerosol change can be monitored independently, and in some cases the concentration changes are closely related to PG changes. For these circumstances, a general theory to remove the local aerosol influence on PG measurements has been developed. Continuous measurements of PG and aerosol mass concentration were made during 24–31 Dec, 2005 within an urban environment at Reading, UK. The average diurnal variation of PG showed a double diurnal cycle, with maxima in the early morning and evening hours. The aerosol concentration has similar double maxima. Removing the aerosol using from the PG and aerosol correlation returns a single diurnal cycle, suggestive of the more global PG diurnal cycle.
Resumo:
Insulating oils are a major component of high voltage plant, including transformers, switchgear and cables. Consequentially, in terms of plant failure, changes in the electrical characteristics of the oil during ageing are of crucial importance. To address this issue, commercial insulating oil was subjected to controlled ageing under laboratory conditions. The electrical properties of the aged oils were then characterized using dielectric spectroscopy. The data suggest that a degree of electrical conductivity occurs in the aged oils, which reduces the insulating properties of the oil as ageing proceeds. The role of atmosphere and additives on the electrical properties of the oils were also explored. Results are compared with model samples, which contain known amounts of materials that may occur as by-products of the ageing process.
Resumo:
IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) – not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.