977 resultados para Dna Variation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The quantitation of serum HBeAg is not commonly used to monitor viral response to therapy in chronic hepatitis B. METHODS: In this study, 21 patients receiving varying therapies were followed and their viral response monitored by concomitant viral load and HBeAg quantitation in order to study the meaning and the kinetics of both parameters. RESULTS: It was possible to distinguish between three different patterns of viral response. The first was characterized by a simultaneous decrease in serum HBV DNA and HBeAg. The second pattern was characterized by a decrease in serum HBeAg but persistent detection of HBV DNA. The third pattern was characterized by undetectable HBV DNA with persistent HBeAg positivity, which points to a non-response (Pattern III-B) except when HBeAg levels showed a slow but steady drop, characterizing a "slow responder" patient (Pattern III-A). CONCLUSIONS: The first pattern is compatible with a viral response. A long-term HBeAg seropositivity with a slow and persistent decrease (Pattern III-A) is also compatible with a viral response and calls for a prolongation of anti-viral treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. Besides genotype, quantitative analysis of HBV infection is extensively used for monitoring disease progression and treatment. Affordable viral load monitoring is desirable in resource-limited settings and it has been already shown to be useful in developing countries for other viruses such as Hepatitis C virus (HCV) and HIV. In this paper, we describe the validation of a real-time PCR assay for HBV DNA quantification with TaqMan chemistry and MGB probes. Primers and probes were designed using an alignment of sequences from all HBV genotypes in order to equally amplify all of them. The assay is internally controlled and was standardized with an international HBV panel. Its efficacy was evaluated comparing the results with two other methods: Versant HBV DNA Assay 3.0 (bDNA, Siemens, NY, USA) and another real-time PCR from a reference laboratory. Intra-assay and inter-assay reproducibilities were determined and the mean of CV values obtained were 0.12 and 0.09, respectively. The assay was validated with a broad dynamic range and is efficient for amplifying all HBV genotypes, providing a good option to quantify HBV DNA as a routine procedure, with a cheap and reliable protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-H. pylori helicobacters (NHPH) have been demonstrated as gastric spiral-shaped bacteria in specimens obtained from dogs; however, their roles in the pathogenesis of upper gastrointestinal disease have not yet been clearly established. The purpose of this study was to evaluate the prevalence of NHPH DNA in the gastric mucosa of dogs and its association with histopathology. Helicobacter was detected through histopathological techniques, PCR, and FISH analysis from fundic biopsies of twenty dogs with or without signs of gastrointestinal disease. PCR and FISH were based on partial 16S rRNA gene sequences. Nineteen dogs showed mild to marked gastritis in the fundus, and only one dog had a healthy gastric mucosa. NHPH DNA was detected in 18 dogs with gastritis and one with normal gastric mucosa. However, there was no significant correlation between the presence of NHPH DNA and the degree of gastritis. These results show a high prevalence of NHPH DNA in the gastric mucosa of dogs from Venezuela. Further studies are necessary to determine a possible association between a specific NHPH species and the degree of gastritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacteria of the genus Bartonella are emerging pathogens detected in lymph node biopsies and aspirates probably caused by increased concentration of bacteria. Twenty-three samples of 18 patients with clinical, laboratory and/or epidemiological data suggesting bartonellosis were subjected to three nested amplifications targeting a fragment of the 60-kDa heat shock protein (HSP), the internal transcribed spacer 16S-23S rRNA (ITS) and the cell division (FtsZ) of Bartonella henselae, in order to improve detection in clinical samples. In the first amplification 01, 04 and 05 samples, were positive by HSP (4.3%), FtsZ (17.4%) and ITS (21.7%), respectively. After the second round six positive samples were identified by nested-HSP (26%), eight by nested-ITS (34.8%) and 18 by nested-FtsZ (78.2%), corresponding to 10 peripheral blood samples, five lymph node biopsies, two skin biopsies and one lymph node aspirate. The nested-FtsZ was more sensitive than nested-HSP and nested-ITS (p < 0.0001), enabling the detection of Bartonella henselae DNA in 15 of 18 patients (83.3%). In this study, three nested-PCR that should be specific for Bartonella henselae amplification were developed, but only the nested-FtsZ did not amplify DNA from Bartonella quintana. We conclude that nested amplifications increased detection of B. henselae DNA, and that the nested-FtsZ was the most sensitive and the only specific to B. henselae in different biological samples. As all samples detected by nested-HSP and nested-ITS, were also by nested-FtsZ, we infer that in our series infections were caused by Bartonella henselae. The high number of positive blood samples draws attention to the use of this biological material in the investigation of bartonellosis, regardless of the immune status of patients. This fact is important in the case of critically ill patients and young children to avoid more invasive procedures such as lymph nodes biopsies and aspirates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asymptomatic Plasmodium infection is a new challenge for public health in the American region. The polymerase chain reaction (PCR) is the best method for diagnosing subpatent parasitemias. In endemic areas, blood collection is hampered by geographical distances and deficient transport and storage conditions of the samples. Because DNA extraction from blood collected on filter paper is an efficient method for molecular studies in high parasitemic individuals, we investigated whether the technique could be an alternative for Plasmodium diagnosis among asymptomatic and pauciparasitemic subjects. In this report we compared three different methods (Chelex®-saponin, methanol and TRIS-EDTA) of DNA extraction from blood collected on filter paper from asymptomatic Plasmodium-infected individuals. Polymerase chain reaction assays for detection of Plasmodium species showed the best results when the Chelex®-saponin method was used. Even though the sensitivity of detection was approximately 66% and 31% for P. falciparum and P. vivax, respectively, this method did not show the effectiveness in DNA extraction required for molecular diagnosis of Plasmodium. The development of better methods for extracting DNA from blood collected on filter paper is important for the diagnosis of subpatent malarial infections in remote areas and would contribute to establishing the epidemiology of this form of infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY High-risk human papillomavirus (hr-HPV) infection is necessary but not sufficient for cervical cancer development. Recently, P16INK4A gene silencing through hypermethylation has been proposed as an important cofactor in cervical carcinogenesis due to its tumor suppressor function. We aimed to investigate P16INK4A methylation status in normal and neoplastic epithelia and evaluate an association with HPV infection and genotype. This cross-sectional study was performed with 141 cervical samples from patients attending Hospital Moncorvo Filho, Rio de Janeiro. HPV detection and genotyping were performed through PCR and P16INK4A methylation by nested-methylation specific PCR (MSP). HPV frequency was 62.4% (88/141). The most common HPV were HPV16 (37%), HPV18 (16.3%) and HPV33/45(15.2%). An upward trend was observed concerning P16INK4A methylation and lesion degree: normal epithelia (10.7%), low grade lesions (22.9%), high grade (57.1%) and carcinoma (93.1%) (p < 0.0001). A multivariate analysis was performed to evaluate an association between methylation, age, tobacco exposure, HPV infection and genotyping. A correlation was found concerning methylation with HPV infection (p < 0.0001), hr-HPV (p = 0.01), HSIL (p < 0.0007) and malignant lesions (p < 0.0001). Since viral infection and epigenetic alterations are related to cervical carcinoma, we suggest that P16INK4A methylation profile maybe thoroughly investigated as a biomarker to identify patients at risk of cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARYThe use of a “direct PCR” DNA polymerase enables PCR amplification without any prior DNA purification from blood samples due to the enzyme's resistance to inhibitors present in blood components. Such DNA polymerases are now commercially available. We compared the PCR performance of six direct PCR-type DNA polymerases (KOD FX, Mighty Amp, Hemo KlenTaq, Phusion Blood II, KAPA Blood, and BIOTAQ) in dried blood eluted from a filter paper with TE buffer. GoTaq Flexi was used as a standard DNA polymerase. PCR performance was evaluated by a nested PCR technique for detecting Plasmodium falciparum genomic DNA in the presence of the blood components. Although all six DNA polymerases showed resistance to blood components compared to the standard Taq polymerase, the KOD FX and BIOTAQ DNA polymerases were resistant to inhibitory blood components at concentrations of 40%, and their PCR performance was superior to that of other DNA polymerases. When the reaction mixture contained a mild detergent, only KOD FX DNA polymerase retained the original amount of amplified product. These results indicate that KOD FX DNA polymerase is the most resistant to inhibitory blood components and/or detergents. Thus, KOD FX DNA polymerase could be useful in serological studies to simultaneously detect antibodies and DNA in eluents for antibodies. KOD FX DNA polymerase is thus not limited to use in detecting malaria parasites, but could also be employed to detect other blood-borne pathogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently there are several methods to extract bacterial DNA based on different principles. However, the amount and the quality of the DNA obtained by each one of those methods is highly variable and microorganism dependent, as illustrated by coagulase-negative staphylococci (CoNS) which have a thick cell wall that is difficult to lyse. This study was designed to compare the quality and the amount of CoNS DNA, extracted by four different techniques: two in-house protocols and two commercial kits. DNA amount and quality determination was performed through spectrophotometry. The extracted DNA was also analyzed using agarose gel electrophoresis and by PCR. 267 isolates of CoNS were used in this study. The column method and thermal lyses showed better results with regard to DNA quality (mean ratio of A260/280 = 1.95) and average concentration of DNA (), respectively. All four methods tested provided appropriate DNA for PCR amplification, but with different yields. DNA quality is important since it allows the application of a large number of molecular biology techniques, and also it's storage for a longer period of time. In this sense the extraction method based on an extraction column presented the best results for CoNS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study was designed to investigate, for the first time, the short-term molecular evolution of the HIV-2 C2, V3 and C3 envelope regions and its association with the immune response. Clonal sequences of the env C2V3C3 region were obtained from a cohort of eighteen HIV-2 chronically infected patients followed prospectively during 2-4 years. Genetic diversity, divergence, positive selection and glycosylation in the C2V3C3 region were analysed as a function of the number of CD4+ T cells and the anti-C2V3C3 IgG and IgA antibody reactivity RESULTS: The mean intra-host nucleotide diversity was 2.1% (SD, 1.1%), increasing along the course of infection in most patients. Diversity at the amino acid level was significantly lower for the V3 region and higher for the C2 region. The average divergence rate was 0.014 substitutions/site/year, which is similar to that reported in chronic HIV-1 infection. The number and position of positively selected sites was highly variable, except for codons 267 and 270 in C2 that were under strong and persistent positive selection in most patients. N-glycosylation sites located in C2 and V3 were conserved in all patients along the course of infection. Intra-host variation of C2V3C3-specific IgG response over time was inversely associated with the variation in nucleotide and amino acid diversity of the C2V3C3 region. Variation of the C2V3C3-specific IgA response was inversely associated with variation in the number of N-glycosylation sites. CONCLUSION: The evolutionary dynamics of HIV-2 envelope during chronic aviremic infection is similar to HIV-1 implying that the virus should be actively replicating in cellular compartments. Convergent evolution of N-glycosylation in C2 and V3, and the limited diversification of V3, indicates that there are important functional constraints to the potential diversity of the HIV-2 envelope. C2V3C3-specific IgG antibodies are effective at reducing viral population size limiting the number of virus escape mutants. The C3 region seems to be a target for IgA antibodies and increasing N-linked glycosylation may prevent HIV-2 envelope recognition by these antibodies. Our results provide new insights into the biology of HIV-2 and its relation with the human host and may have important implications for vaccine design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Evolutionary Biology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Química Especialidade de Química Orgânica, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics