988 resultados para Detector eletroquímico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a measurement of the charged current interaction rate of the electron neutrino beam component of the beam above 1.5 GeV using the large fiducial mass of the T2K π0 detector. The predominant portion of the νe flux (∼85%) at these energies comes from kaon decays. The measured ratio of the observed beam interaction rate to the predicted rate in the detector with water targets filled is 0.89 ± 0.08 (stat.) ± 0.11 (sys.), and with the water targets emptied is 0.90 ± 0.09 (stat.) ± 0.13 (sys.). The ratio obtained for the interactions on water only from an event subtraction method is 0.87 ± 0.33 (stat.) ± 0.21 (sys.). This is the first measurement of the interaction rate of electron neutrinos on water, which is particularly of interest to experiments with water Cherenkov detectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The AEgIS experiment is an interdisciplinary collaboration between atomic, plasma and particle physicists, with the scientific goal of performing the first precision measurement of the Earth's gravitational acceleration on antimatter. The principle of the experiment is as follows: cold antihydrogen atoms are synthesized in a Penning-Malmberg trap and are Stark accelerated towards a moiré deflectometer, the classical counterpart of an atom interferometer, and annihilate on a position sensitive detector. Crucial to the success of the experiment is an antihydrogen detector that will be used to demonstrate the production of antihydrogen and also to measure the temperature of the anti-atoms and the creation of a beam. The operating requirements for the detector are very challenging: it must operate at close to 4 K inside a 1 T solenoid magnetic field and identify the annihilation of the antihydrogen atoms that are produced during the 1 μs period of antihydrogen production. Our solution—called the FACT detector—is based on a novel multi-layer scintillating fiber tracker with SiPM readout and off the shelf FPGA based readout system. This talk will present the design of the FACT detector and detail the operation of the detector in the context of the AEgIS experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gamma detectors based on monolithic scintillator blocks coupled to APDs matrices have proved to be a good alternative to pixelated ones for PET scanners. They provide comparable spatial resolution, improve the sensitivity and make easier the mechanical design of the system. In this study we evaluate by means of Geant4-based simulations the possibility of replacing the APDs by SiPMs. Several commercial matrices of light sensors coupled to LYSO:Ce monolithic blocks have been simulated and compared. Regarding the spatial resolution and linearity of the detector, SiPMs with high photo detection efficiency could become an advantageous replacement for the APDs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have analyzed the performance of a PET demonstrator formed by two sectors of four monolithic detector blocks placed face-to-face. Both front-end and read-out electronics have been evaluated by means of coincidence measurements using a rotating 22Na source placed at the center of the sectors in order to emulate the behavior of a complete full ring. A continuous training method based on neural network (NN) algorithms has been carried out to determine the entrance points over the surface of the detectors. Reconstructed images from 1 MBq 22Na point source and 22Na Derenzo phantom have been obtained using both filtered back projection (FBP) analytic methods and the OSEM 3D iterative algorithm available in the STIR software package [1]. Preliminary data on image reconstruction from a 22Na point source with Ø = 0.25 mm show spatial resolutions from 1.7 to 2.1 mm FWHM in the transverse plane. The results confirm the viability of this design for the development of a full-ring brain PET scanner compatible with magnetic resonance imaging for human studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron spectra unfolding and dose equivalent calculation are complicated tasks in radiation protection, are highly dependent of the neutron energy, and a precise knowledge on neutron spectrometry is essential for all dosimetry-related studies as well as many nuclear physics experiments. In previous works have been reported neutron spectrometry and dosimetry results, by using the ANN technology as alternative solution, starting from the count rates of a Bonner spheres system with a LiI(Eu) thermal neutrons detector, 7 polyethylene spheres and the UTA4 response matrix with 31 energy bins. In this work, an ANN was designed and optimized by using the RDANN methodology for the Bonner spheres system used at CIEMAT Spain, which is composed of a He neutron detector, 12 moderator spheres and a response matrix for 72 energy bins. For the ANN design process a neutrons spectra catalogue compiled by the IAEA was used. From this compilation, the neutrons spectra were converted from lethargy to energy spectra. Then, the resulting energy ?uence spectra were re-binned by using the MCNP code to the corresponding energy bins of the He response matrix before mentioned. With the response matrix and the re-binned spectra the counts rate of the Bonner spheres system were calculated and the resulting re-binned neutrons spectra and calculated counts rate were used as the ANN training data set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of unreliable failure detector was introduced by Chandra and Toueg as a mechanism that provides information about process failures. This mechanism has been used to solve several agreement problems, such as the consensus problem. In this paper, algorithms that implement failure detectors in partially synchronous systems are presented. First two simple algorithms of the weakest class to solve the consensus problem, namely the Eventually Strong class (⋄S), are presented. While the first algorithm is wait-free, the second algorithm is f-resilient, where f is a known upper bound on the number of faulty processes. Both algorithms guarantee that, eventually, all the correct processes agree permanently on a common correct process, i.e. they also implement a failure detector of the class Omega (Ω). They are also shown to be optimal in terms of the number of communication links used forever. Additionally, a wait-free algorithm that implements a failure detector of the Eventually Perfect class (⋄P) is presented. This algorithm is shown to be optimal in terms of the number of bidirectional links used forever.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The set agreement problem states that from n proposed values at most n-1 can be decided. Traditionally, this problem is solved using a failure detector in asynchronous systems where processes may crash but not recover, where processes have different identities, and where all processes initially know the membership. In this paper we study the set agreement problem and the weakest failure detector L used to solve it in asynchronous message passing systems where processes may crash and recover, with homonyms (i.e., processes may have equal identities) and without a complete initial knowledge of the membership.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detectors designing is a key aspect for the development of the new millimeter wave systems. In this paper two detectors in microstrip technology are presented. They use zero bias Schottky diodes to detect signals from low frequency to 40 GHz. High sensibility, flat frequency response and ultrabroadband are the main features of these designs. They are also cheap and easy to mount because they have been built using microstrip technology. This paper explains most technological questions which must be taken into account to design such detectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed 241AmBe neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The azimuthal asymmetry in the risetime of signals in Auger surface detector stations is a source of information on shower development. The azimuthal asymmetry is due to a combination of the longitudinal evolution of the shower and geometrical effects related to the angles of incidence of the particles into the detectors. The magnitude of the effect depends upon the zenith angle and state of development of the shower and thus provides a novel observable, (sec theta)(max), sensitive to the mass composition of cosmic rays above 3 x 10(18) eV. By comparing measurements with predictions from shower simulations, we find for both of our adopted models of hadronic physics (QGSJETII-04 and EPOS-LHC) an indication that the mean cosmic-ray mass increases slowly with energy, as has been inferred from other studies. However, the mass estimates are dependent on the shower model and on the range of distance from the shower core selected. Thus the method has uncovered further deficiencies in our understanding of shower modeling that must be resolved before the mass composition can be inferred from (sec theta)(max).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents signal processing techniques to detect a passive thermal threshold detector based on a chipless time-domain ultrawideband (UWB) radio frequency identification (RFID) tag. The tag is composed by a UWB antenna connected to a transmission line, in turn loaded with a biomorphic thermal switch. The working principle consists of detecting the impedance change of the thermal switch. This change occurs when the temperature exceeds a threshold. A UWB radar is used as the reader. The difference between the actual time sample and a reference signal obtained from the averaging of previous samples is used to determine the switch transition and to mitigate the interferences derived from clutter reflections. A gain compensation function is applied to equalize the attenuation due to propagation loss. An improved method based on the continuous wavelet transform with Morlet wavelet is used to overcome detection problems associated to a low signal-to-noise ratio at the receiver. The average delay profile is used to detect the tag delay. Experimental measurements up to 5 m are obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os ésteres de ftalato (PAEs) são compostos produzidos em grandes quantidades, amplamente utilizados industrialmente como agentes plastificantes. Seus resíduos são lixiviados pela água tornando-se poluentes orgânicos persistentes (POPs) no meio ambiente aquoso, além de apresentar características de interferência endócrina. O dietil ftalato (DEP) é frequentemente encontrado nas amostras ambientais, pois possui elevada solubilidade na água e pode ser gerado durante a degradação de outros PAEs. Assim, este trabalho teve como objetivo a degradação do dietil ftalato em meio aquoso por método eletroquímico utilizando um ânodo dimensionalmente estável (ADE) comercial representado como Ti/Ru0,3Ti0,7O2 em uma célula do tipo filtro-prensa. As eletrólises foram de 120 minutos contendo uma concentração inicial de 100,3 mg L-1 de DEP, pH inicial igual a 3, a temperatura em 25 °C e vazão em 250 mL min-1. Os experimentos foram feitos utilizando planejamento fatorial do tipo 32 com duas réplicas no ponto central, apresentando como variáveis independentes a densidade de corrente (10, 25 e 40 mA cm-2) e o logaritmo em base 10 da forca iônica do eletrólito suporte, NaCl e Na2SO4 (µ = 0,05, 0,15 e 0,5 mol L-1), com o intuito de estudar o efeito da densidade de corrente, concentração e natureza do eletrólito para determinar a melhor condição de degradação do dietil ftalato. O monitoramento da concentração do DEP foi feito com cromatografia líquida de alta eficiência (CLAE) e a mineralização foi acompanhada pelas análises de carbono orgânico total (COT). Foram obtidas maiores porcentagens de remoção e mineralização com uso das maiores densidades de corrente e na presença de altas concentrações de NaCl em comparação com Na2SO4. Dessa maneira, se obteve remoção de 63,2 % e mineralização de 63,9 % em solução 0,5 mol L-1 NaCl e densidade de corrente de 40 mA cm-2, enquanto que para Na2SO4 (µ = 0,5 mol L-1) e 40 mA cm-2 foi removido 51,3 % e mineralizado 53,0 % de DEP. O mecanismo de degradação de DEP foi determinado em meio de NaCl e Na2SO4, através de CLAE-MS nas condições citadas anteriormente, identificando-se os íons moleculares de m/z 149 e 177 em ambos eletrólitos, correspondentes ao anidrido ftálico protonado e ao aduto do anidrido ftálico com C(2)H(5)(+) respectivamente, íons característicos da fragmentação do DEP, além do íon m/z 239 em Na2SO4 correspondente ao dietil 3-hidroxiftalato. A degradação do DEP acontece através da cadeia alifática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ligas de níquel têm atualmente uma vasta gama de aplicações, sendo a agressividade do meio e as elevadas temperaturas que estas ligas suportam, um diferencial excepcional. A liga UNS N07090, objeto deste trabalho, encontra aplicações muito diversas, entre elas turbocompressores, sistemas de exaustão e de pós-tratamento de motores a diesel. Nestas aplicações a liga está exposta a gases, que ao condensarem formam ácido sulfúrico (H2SO4). Torna-se, assim, importante, o conhecimento da resistência à corrosão da liga nesse meio. O presente trabalho tem como objetivo caracterizar o comportamento eletroquímico da liga através de curvas de polarização potenciodinâmica em diferentes concentrações de ácido sulfúrico. Observou-se que quanto maior a concentração de ácido, maior é a corrosão da liga. Este fato pode ser discutido pela adsorção do íon sulfato (SO42-), que prejudica tanto a formação quanto a cinética de crescimento da película passiva do níquel. Em contrapartida, a presença de Cr na liga UNS N07090 apresentou um benefício sobre a resistência à corrosão desta muito acima do esperado, influenciando de forma direta as curvas de polarização da liga e mantendo-a em condição de elevada resistência à corrosão em detrimento do pior desempenho observado em outros elementos pertecentes à liga, como Co, Al e Ti. Tempos de imersão de 24h em ácido sulfúrico elevam discretamente os parâmetros de corrosão da liga, mantendo-os, no entanto em patamares bastante baixos, permitindo finalmente concluir que a liga UNS N07090, quando exposta a concentrações que variam de 1M a 4M H2SO4, a 25°C, apresenta boa resistência à corrosão e que esta não se altera com o tempo de exposição. A análise dos resultados mostrou que o processo corrosivo é controlado por reações catódicas de sulfato e hidrogênio, as quais podem ter diferentes contribuições dependendo da concentração do ácido e do tempo de imersão da liga UNS N07090 no meio corrosivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho foram desenvolvidos detectores de radiação Barreira de superfície de silício que fossem capazes de detectar a presença da radiação gama de baixa energia proveniente de sementes de iodo-125 utilizada em tratamentos de braquiterapia. A partir de substratos comerciais de silício foram desenvolvidos os detectores, de uma sequência que partiu de tratamentos químicos nas superfícies destes substratos com a intenção de minimizar os possíveis ruídos gerados, validação das amostras obtidas como diodos, assegurando características detectoras, e a efetiva utilização como detector para fontes radioativas de iodo-125 com energia em torno de 25 kev e amerício-251 com energia na ordem de 59 kev. Finalizou realizando a análise dos espectros de energia obtidos e assim foi possível observar a capacidade destes detectores para mensuração da energia proveniente destas sementes.