962 resultados para Denture, Complete, Immediate
Resumo:
The aims of this study were to evaluate the reliability and to validate a Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (OHIP-EDENT), an inventory for measuring oral health-related quality of life of edentulous subjects. The sample comprised 65 complete denture wearers (23 men, mean age of 69.1 +/- 10.3 years). The translated OHIP-EDENT was applied on two occasions with a washout period of 3 months. Reliability was assessed by an internal consistency analysis and a test-retest approach. A preliminary validation process was conducted by a qualitative approach/interview. Results of internal consistency showed a Cronbach's alpha of 0.86 or 0.90 for the first or second appointment respectively. Through the test-retest analysis, an intra-class correlation coefficient of 0.57 was found, and individual answers reflected a broad range of agreement. Interviewed volunteers (n = 6) comprehended most questions well. In conclusion, the Brazilian version of OHIP-EDENT is adequate for assessing the oral health-related quality of life for edentulous subjects.
Resumo:
Statement of problem. Microwave postpolymerization has been Suggested as a method to improve the mechanical strength of repaired denture base materials. However, the effect of microwave heating oil the flexural strength of the autopolymerizing denture reline resins has not been investigated.Purpose. This study analyzed the effect of microwave postpolymerization on the flexural strength of 4 autopolymerizing reline resins (Duraliner II, Kooliner, Ufi Gel Hard, and Tokuso Rebase Fast) and 1 heat-polymerized resin (Lucitone 550).Material and methods. For each material, 80 specimens (64 X 10 X 3.3 mm) were polymerized according to the manufacturer's instructions and divided into 10 groups (n = 8). Control group specimens remained as processed. Before testing, the specimens were Subjected to postpolymerization in a microwave oven using different power (500, 5,50, or 650 W) and time (3, 4, or 5 Minutes) settings. Load measurements (newtons) were made at a crosshead speed of 5 mm/min using a 3-point bending device with a span of 50 mill. The flexural strength values were calculated in MPa. Data analyses included 3-way and 2-way analysis of variance and the Tukey Honestly Significant Difference test (alpha=.05).Results. The flexural strengths of resins Duraliner 11 and Kooliner were significantly increased (P=.0015 and P=.0046, respectively) with the application of microwave irradiation using different time/power combinations. The materials Lucitone 550, Tokuso Rebase Fast, and Ufi Gel Hard demonstrated no significant strength improvement compared to the corresponding control. Only after microwave postpolymerization irradiation for 3 minutes at 550 W did Lucitione 550 show significantly higher flexural strength than Tokuso Rebase Fast and Ufi Gel Hard relining resins.Conclusion. Microwave postpolymerization irradiation can be an effective method for increasing the flexural strength of Duraliner II (at 650 W) and Kooliner (at 550 W and 650 W for 5 minutes).
Resumo:
Objective: the purpose of this research was to study the cases of inflammatory fibrous hyperplasia (IFH) at the Clinic of Semiology, Department of Bioscience and Oral Diagnosis, Sao Jose dos Campos Dental School, State University of São Paulo, Brazil. Methods and materials: A total of 141 clinical file cards indicating a final diagnosis of IFH, from the archives of the Department of Bioscience and Oral Diagnosis and dated from 1979 to 2001, were included in the study. of these files, 50 indicated a diagnosis of denture-induced fibrous hyperplasia. Sex, age, race, duration, and clinical features that confirm their classification in the non-neoplastic proliferating process were analyzed statistically. Results: of the 50 analyzed cases of denture-induced lesion, 22% occurred in men and 78% in women. Patients in the age group of 41 to 50 years presented the highest frequency of the lesion. Conclusions: Inflammatory fibrous hyperplasia occurs more frequently in women (71.63%), and denture-induced lesions appear mainly in patients over 40 years of age (70% of cases). Patients with denture-induced hyperplasia reported pain associated with the lesion (70%).
Resumo:
Objectives: the aim of this study was to compare the satisfaction and the quality of life in an elderly population using either mandibular conventional dentures or implant-retained overdentures.Materials and methods: A total of 34 patients were divided into two groups: group I-complete dentures users; group II - users of upper complete dentures opposed by implant-retained overdentures. The subjects were submitted to a questionnaire based on Oral Health impact Profile and oral health related quality of life to evaluate their satisfaction levels and quality of life with their prostheses. Data were evaluated using a non-parametric statistical analysis (Fischer test) with significant difference at alpha = 0.05.Results: There were no significant differences between the groups in relation to comfort, aesthetics, chewing ability, overall satisfaction, pain, functional, phonetic, social, and psychological limitations (p > 0.05). Comparing the stability of mandibular dentures, group II presented the better results (p < 0.05).Conclusion: Although the stability of the mandibular implant-retained overdenture was enhanced compared to a conventional denture, the quality of life and satisfaction levels were similar for both the groups.
The incidence of temporomandibular disorder signs and symptoms in patients wearing complete dentures
Resumo:
Prosthodontics should be one of the means of establishing conditions for the maintenance of periodontal health. The forces applied to the abutment teeth and their effects are very important considerations in the design and construction of the removable partial dentures. This 6-month follow-up clinical study evaluated the degree of mobility of abutment teeth of distal extension and tooth supported removable partial dentures by using Periotest. Two types of clasp design were selected for evaluation. In cases with unilateral and bilateral distal-extension, a clasp design including a T clasp of Roach retentive arm, a rigid reciprocal arm and a mesial rest were used. For the abutments of tooth-supported removable partial dentures, a second clasp design with a cast circumferential buccal retentive arm, a rigid reciprocal clasp arm and a rest adjacent to the edentulous ridges was selected. A total of 68 abutment teeth was analysed. Periotest values were made at the time of denture placement (control) and at 1, 3 and 6 months after the denture placement. The statistical analysis was performed using Friedman test. All analysis was performed at a 0.05 level of significance. The results revelled that no significant changes in tooth mobility were observed during the 6-months follow-up (P > 0.05). In conclusion, our findings suggest that adequate oral hygiene instructions, careful prosthetic treatment planning and regular recall appointments play an important role in preventing changes in abutment tooth mobility caused by removable partial denture placement.
Resumo:
Statement of problem. Acrylic resin denture teeth soften upon immersion in water, and the heating generated during microwave sterilization may enhance this process.Purpose. Six brands of acrylic resin denture teeth were investigated with respect to the effect of microwave sterilization and water immersion on Vickers hardness (VHN).Material and Methods. The acrylic resin denture teeth (Dentron [D], Vipi Dent Plus [V], Postaris [P], Biolux [B], Trilux [T], and Artiplus [A]) were embedded in heat-polymerized acrylic resin within polyvinylchloride tubes. For each brand, the occlusal surfaces of 32 identical acrylic resin denture posterior teeth were ground flat with 1500-grit silicon carbide paper and polished on a wet polishing wheel with a slurry of tin oxide. Hardness tests were performed after polishing (control group, C) after polishing followed by 2 cycles of microwave sterilization at 650 W for 6 minutes (MwS group), after polishing followed by 90-day immersion in water (90-day Wim group), and after polishing followed by 90-day storage in water and 2 cycles of microwave sterilization (90-day Wim + MwS group). For each specimen, 8 hardness measurements were made and the mean was calculated. Data were analyzed with a 2-way analysis of variance followed by the Bonferroni procedure to determine any significance between pairs of mean values (alpha=.01).Results: Mircrowave sterilization of specimens significantly decreased (P <.001) the hardness of the acrylic resin denture tooth specimens P (17.8 to 16.6 VHN, V (18.3 to 15.8 VHN), T (17.4 to 15.3 VHN), B (16.8 to 15.7 VHN), and A (17.3 to 15.7 VHN). For all acrylic resin denture teeth, no significant differences in hardness were found between the groups Mws, 90-day Wim, and 90-day Wim + MwS, with the exception of the 90-day Wim + MwS tooth A specimens (14.4 VHN), which demonstrated significant lower mean values (P <.001) than the 90-day Wim (15.8 VHN) and MwS (15.7 VHN) specimens.Conclusions. For specimens immersed in water for 90 days, 2 cycles of microwave sterilization had no effect on the hardness of most of the acrylic resin denture teeth.
Resumo:
The aim of this study was to evaluate, through histologic examination, the effect of surgical repositioning of intruded dog teeth upon the pulpal and surrounding tissues. Thirty teeth in 10 adult dogs, aged 2-3 years, were used. Fifteen teeth were intruded, surgically repositioned and fixed using orthodontics wire, composite resin, and enamel acid conditioning. All these teeth served as the experimental group. The remaining intruded teeth were not treated ( control group). The animals were sacrificed to allow observations at 7,15, and 30 post-operative days. The maxillary and mandibular archs were removed and processed for histologic exam. Based on the methodology and observed results, we concluded that: pulpal necrosis, external root resorption and ankylosis were common sequelae to severe traumatic intrusion; a careful immediate surgical repositioning of severed intruded permanent tooth with complete root formation has many advantages with few disadvantages.