938 resultados para DOPPLER ULTRASOUND
Resumo:
Study Objective: To evaluate the diagnostic accuracy of transvaginal ultrasound and office hysteroscopy in the differentiation between endometrial polyps and endometrial adenocarcinoma. Design: This is a prospective 100 women longitudinal study, 24 to 80 years, submitted to hysteroscopic polypectomy (n = 80) or surgery due to endometrial adenocarcinoma (n = 20), from january 2010 to December 2011. Clinical, ultrasonographic and hysteroscopic parameters were analyzed and compared with histopathologic find. Statistical analysis were performed utilizing the Tukey, Kruskal-Wallis, Dunn and Mann-Whitney test, with a confidence interval of 95% and p\0, 05 statiscally significant. Setting: Botucatu Medical School. Intervention: Prospective analysis of clinical, ultrasonographic and hysteroscopic parameters in patients with diagnosis suspected of endometrial polyps and adenocarcinoma of endometrium were performed. According to the diagnosis, hysteroscopic polypectomy or pan hysterectomy with lymph node sampling was realized. After the surgery and histopathological study, statistical analysis of parameters was performed and the results were compared between groups. It was Research Ethics Committee approved. Measurements and Main Results: There were no differences between age, BMI, menopause, TH use and associated diseases among groups. The main symptom of endometrial cancer was the postmenopausal bleeding, affecting 84,2% of women against 34,8% of polypectomy group. The majority of women with endometrial polyps were asymptomatic. Transvaginal ultrasonography showed no ability to differentiate cases of endometrial cancer compared with the cases of endometrial polyps, considering the presence of endometrial thickness and blood flow on color Doppler. Office hysteroscopy showed significant changes in 75% of the adenocarcinoma cases, especially the presence of diffuse hypervascularity with atypical vessels. Conclusion: Still remains an inability to establish clinical parameters and reliable ultrasound imaging to differentiate endometrial polyps and cancer of endometrium. Attention should be given to hysteroscopic exams presenting diffuse endometrial hypervascularization with architectural distortion of the vessels. The recommendation of our service remains the systematic removal of all endometrial polyps.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Degeneration of tendon tissue is a common cause of tendon dysfunction with the symptoms of repeated episodes of pain and palpable increase of tendon thickness. Tendon mechanical properties are directly related to its physiological composition and the structural organization of the interior collagen fibers which could be altered by tendon degeneration due to overuse or injury. Thus, measuring mechanical properties of tendon tissue may represent a quantitative measurement of pain, reduced function, and tissue health. Ultrasound elasticity imaging has been developed in the last two decades and has proved to be a promising tool for tissue elasticity imaging. To date, however, well established protocols of tendinopathy elasticity imaging for diagnosing tendon degeneration in early stages or late stages do not exist. This thesis describes the re-creation of one dynamic ultrasound elasticity imaging method and the development of an ultrasound transient shear wave elasticity imaging platform for tendon and other musculoskeletal tissue imaging. An experimental mechanical stage with proper supporting systems and accurate translating stages was designed and made. A variety of high-quality tissue-mimicking phantoms were made to simulate homogeneous and heterogeneous soft tissues as well as tendon tissues. A series of data acquisition and data processing programs were developed to collect the displacement data from the phantom and calculate the shear modulus and Young’s modulus of the target. The imaging platform was found to be capable of conducting comparative measurements of the elastic parameters of the phantoms and quantitatively mapping elasticity onto ultrasound B-Mode images. This suggests the system has great potential for not only benefiting individuals with tendinopathy with an earlier detection, intervention and better rehabilitation, but also for providing a medical tool for quantification of musculoskeletal tissue dysfunction in other regions of the body such as the shoulder, elbow and knee.
Resumo:
Fifteen live adult male botos, or Amazon river dolphins (Inia geoffrensis), were examined using ultrasonography during the yearly capture expedition, between October and November 2005, at the Mamiraua Sustainable Development Reserve, within the Brazilian Amazon (3 degrees S, 65 degrees W). All examinations were performed with a Sonosite 180 plus ultrasound unit in conjunction with a 2- to 5-MHz multifrequency transducer convex array 180 Plus/Elite-C60. Age and maturity estimates were determined considering the body length, weight, and external characteristics. In all examinations, the testes were discerned by the presence of a hyperechoic central line, called the mediastinum testis, a landmark for their identification during ultrasonography. No significant differences in echogenicity were detected on the ultrasonographic appearance of the testes among the studied animals. On adult male botos, apparent parenchymal nodulation of the testis was observed on scanning in most of the animals and probably constituted evidence of reproductive maturity. Using the color Doppler technique, blood flow was detected along the mediastinum testis that progressively decreased toward the periphery of this organ. Little blood flow could be identified by color Doppler. Power Doppler allowed better accuracy to identify testicular vessels, their topography, and their differentiation from adjacent structures. Ultrasonographic examination provides useful data for morphologic characterization of the boto's testes. Examination using Doppler techniques was considered a valuable tool to evidence blood flow through the testicular parenchyma.
Resumo:
OBJECTIVE: The purpose of this study was to establish longitudinal reference ranges for fetal ultrasound biometry measurements and growth parameters in twin pregnancies. METHOD: A total of 200 uncomplicated twin pregnancies before 21 weeks of gestation were recruited for this prospective, longitudinal study. Women who abandoned follow-up, pregnancies with unknown outcomes or pregnancies with complications were excluded. Ultrasound scans were performed every three weeks, and biparietal and occipitofrontal diameters, head and abdominal circumferences, and femur diaphysis length measurements were obtained for each fetus at each visit. Estimated fetal weight, biparietal/occipitofrontal diameter, head circumference/abdominal circumference, and femur diaphysis length/abdominal circumference ratios were also calculated. Multilevel regression analysis was performed on normalized data. RESULTS: A total of 807 ultrasound examinations were performed in 125 twin pregnancies between 14 and 38 weeks of gestation (6.5 +/- 1.4 scans/pregnancy). Regression analysis demonstrated significant correlations for all variables with gestational age, namely log of the biparietal diameter (r = 0.98), log of the occipitofrontal diameter (r = 0.98), log of the head circumference (r = 0.99), log of the abdominal circumference (r = 0.98), square root of the femur length (r = 0.99), log of the estimated fetal weight (r = 0.99), biparietal/occipitofrontal ratio (r = -0.11), head/abdomen circumference ratio (r = -0.56), and log of the femur length/abdominal circumference ratio (r = 0.61). Values corresponding to the 10th, 50th, and 90th percentiles for estimated fetal weight at 28, 32, and 36 weeks, respectively, were as follows: 937, 1,096, 1,284 g; 1,462, 1,720, 2,025 g; and 2,020, 2,399, 2,849 g. CONCLUSION: In twin pregnancies, fetal ultrasound biometry measurements and growth parameters show a significant correlation with gestational age.
Resumo:
Given the important role of leptin in metabolism, we looked for a possible association of leptin and leptin receptor polymorphisms with carcass and growth traits in Nellore cattle. We examined associations of leptin and leptin receptor SNPs with ultrasound carcass (longissimus dorsi muscle area (ribeye area), backfat thickness and rump fat thickness and growth traits (weaning weight adjusted to 210 days of age, yearling weight adjusted to 550 days of age, weight gain of weaning to yearling and scrotal circumference adjusted to 550 days of age) of 2162 Bos primigenius indicus (Nellore) animals. Allele and genotypic frequencies were calculated for each marker. Allele substitution, additive and dominance effects of the polymorphisms were also evaluated. Some alleles of the molecular markers had low frequencies, lower than 1%, in the sample analyzed, although the same polymorphisms described for B. p. taurus cattle were found. Due to very low allelic frequencies, the E2JW, A59V and UASMS2 markers were not included in the analysis, because they were almost fixed. E2FB was found to be significantly associated with weight gain, ribeye area and backfat thickness. The promoter region markers, C963T and UASMS1, were also found to be significantly associated with ribeye area. T945M was significantly associated with weight gain. We conclude that the leptin and receptor gene markers would be useful for marker-assisted selection.
Resumo:
In the clinical setting, the early detection of myocardial injury induced by doxorubicin (DXR) is still considered a challenge. To assess whether ultrasonic tissue characterization (UTC) can identify early DXR-related myocardial lesions and their correlation with collagen myocardial percentages, we studied 60 rats at basal status and prospectively after 2mg/Kg/week DXR endovenous infusion. Echocardiographic examinations were conducted at baseline and at 8,10,12,14 and 16 mg/Kg DXR cumulative dose. The left ventricle ejection fraction (LVEF), shortening fraction (SF), and the UTC indices: corrected coefficient of integrated backscatter (IBS) (tissue IBS intensity/phantom IBS intensity) (CC-IBS) and the cyclic variation magnitude of this intensity curve (MCV) were measured. The variation of each parameter of study through DXR dose was expressed by the average and standard error at specific DXR dosages and those at baseline. The collagen percent (%) was calculated in six control group animals and 24 DXR group animals. CC-IBS increased (1.29 +/- 0.27 x 1.1 +/- 0.26-basal; p=0.005) and MCV decreased (9.1 +/- 2.8 x 11.02 +/- 2.6-basal; p=0.006) from 8 mg/Kg to 16mg/Kg DXR. LVEF presented only a slight but significant decrease (80.4 +/- 6.9% x 85.3 +/- 6.9%-basal, p=0.005) from 8 mg/Kg to 16 mg/Kg DXR. CC-IBS was 72.2% sensitive and 83.3% specific to detect collagen deposition of 4.24%(AUC=0.76). LVEF was not accurate to detect initial collagen deposition (AUC=0.54). In conclusion: UTC was able to early identify the DXR myocardial lesion when compared to LVEF, showing good accuracy to detect the initial collagen deposition in this experimental animal model.
Resumo:
We evaluated the diagnostic quality of first-trimester ultrasound images transmitted in realtime using low-cost telecommunications. A prospective sample of fetal ultrasound images from 11 weeks to 13 weeks and six days of pregnancy was obtained from pregnant women over 18 years old. The examinations were transmitted in realtime to three independent examiners who carried out a qualitative assessment based on parameters established by the Fetal Medicine Foundation. All fetal structures could be viewed and the quality of images received by the examiners was considered normal. There were significant differences for crown-rump length and nuchal translucency in the transmitted images but the loss in definition was acceptable. Thus the quality of images transmitted via the Internet through the use of low-cost software appeared suitable for screening for chromosomal abnormalities in the first trimester of pregnancy.
Resumo:
Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.
Resumo:
Object. Sonothrombolysis has recently been considered an emerging modality for the treatment of stroke. The purpose of the present paper was to review randomized clinical studies concerning the effects of sonothrombolysis associated with tissue plasminogen activator (tPA) on acute ischemic stroke. Methods. Systematic searches for literature published between January 1996 and July 2011 were performed for studies regarding sonothrombolysis combined with tPA for acute ischemic stroke. Only randomized controlled trials were included. Data extraction was based on ultrasound variables, patient characteristics, and outcome variables (rate of intracranial hemorrhages and arterial recanalization). Results. Four trials were included in this study; 2 trials evaluated the effect of transcranial Doppler (TCD) ultrasonography on sonothrombolysis, and 2 addressed transcranial color-coded duplex (TCCD) ultrasonography. The frequency of ultrasound waves varied from 1.8 to 2 MHz. The duration of thrombus exposure to ultrasound energy ranged from 60 to 120 minutes. Sample sizes were small, recanalization was evaluated at different time points (60 and 120 minutes), and inclusion criteria were heterogeneous. Sonothrombolysis combined with tPA did not lead to an increase in symptomatic intracranial hemorrhagic complications. Two studies demonstrated that patients treated with ultrasound combined with tPA had statistically significant higher rates of recanalization than patients treated with tPA alone. Conclusions. Despite the heterogeneity and the limitations of the reviewed studies, there is evidence that sonothrombolysis associated with tPA is a safe procedure and results in an increased rate of recanalization in the setting of acute ischemic stroke when wave frequencies and energy intensities of diagnostic ultrasound systems are used. (http://thejns.org/doi/abs/10.3171/2011.10.FOCUS11251)
Resumo:
The objective of this study was to develop equations to predict retail product and fat trim (weights and percentages) for Nellore (Bos indicus) cattle. Live ultrasound measurements of the longissimus muscle area, backfat thickness at the 12th rib and rump fat depth and shrunk body weight were obtained from 218 Nellore steers to predict weights and percentages of carcass retail product, pistola retail product and fat trimmings. After slaughter, carcasses were deboned and weighed and percentages of retail cuts were obtained directly. Measurements taken directly in the carcasses explained 97% and 36% of variation in carcass retail product weight and percentage, and 94% and 36% of variation in pistola retail weight and percentage, respectively. Live measurements explained 93% of carcass retail product weight and 39% of carcass retail product percentage. Lower accuracies were observed for pistola retail product weight (R-2=0.87) and percentage (R-2=0.33). Accuracies for fat trimmings weight and percentage were 79% and 55%, respectively. Ultrasound rump fat thickness showed greater correlations with retail product and fat trimmings (weights and percentages) when compared with ultrasound backfat thickness. The weight and percentage of retail products and of trimmable fat can be estimated in Nellore steers from live animal measurements, with similar accuracy to equations developed based on carcass measurements obtained at slaughter.
Resumo:
This study aims to evaluate the thickness of the femoral quadriceps and biceps brachii and brachialis muscles bilaterally and the adjacent subcutaneous fat in patients undergoing gastric bypass Roux-en-Y before and after surgery, using ultrasound as the diagnostic method of choice. We studied 12 patients undergoing this surgical method preoperatively and during the first, third, and sixth postoperative months. During these periods, patients were evaluated by ultrasound to determine the thickness of subcutaneous adipose tissue and muscle of the upper and lower limbs. Postoperatively, these patients showed a reduction in the thickness of the upper and lower extremities muscle and adipose tissue as compared to their preoperative values. There was a significant difference in the loss of muscle thickness in all postoperative months and in the thickness of fatty tissue in the sixth month after surgery, compared to the preoperative muscle and fatty tissue thickness. Ultrasound can be considered as the diagnostic method of choice when assessment of the fat and lean body mass is required in morbidly obese patients before and after bariatric surgery.
Resumo:
Background: The high and increasing prevalence of Dilated Cardiomyopathy (DCM) represents a serious public health issue. Novel technologies have been used aiming to improve diagnosis and the therapeutic approach. In this context, speckle tracking echocardiography (STE) uses natural myocardial markers to analyze the systolic deformation of the left ventricle (LV). Objective: Measure the longitudinal transmural global strain (GS) of the LV through STE in patients with severe DCM, comparing the results with normal individuals and with echocardiographic parameters established for the analysis of LV systolic function, in order to validate the method in this population. Methods: Seventy-one patients with severe DCM (53 +/- 12 years, 72% men) and 20 controls (30 +/- 8 years, 45% men) were studied. The following variables were studied: LV volumes and ejection fraction calculated by two and three-dimensional echocardiography, Doppler parameters, Tissue Doppler Imaging systolic and diastolic LV velocities and GS obtained by STE. Results: Compared with controls, LV volumes were higher in the DCM group; however, LVEF and peak E-wave velocity were lower in the latter. The myocardial performance index was higher in the patient group. Tissue Doppler myocardial velocities (S', e', a') were significantly lower and E/e' ratio was higher in the DCM group. GS was decreased in the DCM group (-5.5% +/- 2.3%) when compared with controls (-14.0% +/- 1.8%). Conclusion: In this study, GS was significantly lower in patients with severe DCM, bringing new perspectives for therapeutic approaches in this specific population. (Arq Bras Cardiol 2012;99(3):834-842)
Resumo:
Objective To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy. Method This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival). Results In total, 16 fetuses with congenital lung lesions underwent invasive percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p?=?0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p?<?0.01). Conclusion Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. (C) 2012 John Wiley & Sons, Ltd.