909 resultados para DIAGNOSTIC USES
Resumo:
Background. Hhereditary cystic kidney diseases are a heterogeneous spectrum of disorders leading to renal failure. Clinical features and family history can help to distinguish the recessive from dominant diseases but the differential diagnosis is difficult due the phenotypic overlap. The molecular diagnosis is often the only way to characterize the different forms. A conventional molecular screening is suitable for small genes but is expensive and time-consuming for large size genes. Next Generation Sequencing (NGS) technologies enables massively parallel sequencing of nucleic acid fragments. Purpose. The first purpose was to validate a diagnostic algorithm useful to drive the genetic screening. The second aim was to validate a NGS protocol of PKHD1 gene. Methods. DNAs from 50 patients were submitted to conventional screening of NPHP1, NPHP5, UMOD, REN and HNF1B genes. 5 patients with known mutations in PKHD1 were submitted to NGS to validate the new method and a not genotyped proband with his parents were analyzed for a diagnostic application. Results. The conventional molecular screening detected 8 mutations: 1) the novel p.E48K of REN in a patient with cystic nephropathy, hyperuricemia, hyperkalemia and anemia; 2) p.R489X of NPHP5 in a patient with Senior Loken Syndrome; 3) pR295C of HNF1B in a patient with renal failure and diabetes.; 4) the NPHP1 deletion in 3 patients with medullar cysts; 5) the HNF1B deletion in a patient with medullar cysts and renal hypoplasia and in a diabetic patient with liver disease. The NGS of PKHD1 detected all known mutations and two additional variants during the validation. The diagnostic NGS analysis identified the patient’s compound heterozygosity with a maternal frameshift mutation and a paternal missense mutation besides a not transmitted paternal missense mutation. Conclusions. The results confirm the validity of our diagnostic algorithm and suggest the possibility to introduce this NGS protocol to clinical practice.
Resumo:
This thesis work deals, principally, with the development of different chemical protocols ranging from environmental sustainability peptide synthesis to asymmetric synthesis of modified tryptophans to a series of straightforward procedures for constraining peptide backbones without the need for a pre-formed scaffold. Much efforts have been dedicated to the structural analysis in a biomimetic environment, fundamental for predicting the in vivo conformation of compounds, as well as for giving a rationale to the experimentally determined bioactivity. The conformational analyses in solution has been done mostly by NMR (2D gCosy, Roesy, VT, titration experiments, molecular dynamics, etc.), FT-IR and ECD spectroscopy. As a practical application, 3D rigid scaffolds have been employed for the synthesis of biological active compounds based on peptidomimetic and retro-mimetic structures. These mimics have been investigated for their potential as antiflammatory agents and actually the results obtained are very promising. Moreover, the synthesis of Amo ring permitted the development of an alternative high effective synthetic pathway for obtaining Linezolid antibiotic. The final section is, instead, dedicated to the construction of a new biosensor based on zeolite L SAMs functionalized with the integrin ligand c[RGDfK], that has showed high efficiency for the selective detection of tumor cells. Such kind of sensor could, in fact, enable the convenient, non-invasive detection and diagnosis of cancer in early stages, from a few drops of a patient's blood or other biological fluids. In conclusion, the researches described herein demonstrate that the peptidomimetic approach to 3D definite structures, allows unambiguous investigation of the structure-activity relationships, giving an access to a wide range bioactive compounds of pharmaceutical interest to use not only as potential drugs but also for diagnostic and theranostic applications.
Resumo:
Since its approval by FDA in 2001, capsule endoscopy revolutionized the study of small bowel. One of the main limitations of its diffusion has been the high cost. More recently, a new videocapsule system (OMOM CE) has been developed in China and obtained the CE mark. Its cost is approximately half that of other capsule systems. However, there are few studies regarding the clinical experience with this new videocapsule system and none of them has been performed in the western world. Among the limitations of capsule endoscopy, there is also one linked to the diagnostic yield. The rapid transit of the device in the proximal segments implies a high risk of false negatives; an indirect confirmation of this limit is offered by the poor ability to identify the papilla of Vater. In addition, recent studies show that in patients with obscure gastrointestinal bleeding, the negative outcome of capsule endoscopy is correlated to a significant risk of recurrence of anemia in the short term, as well as the presence of small bowel lesions documented by a second capsule endoscopy. It was recently approved the use of a new device called "CapsoCam" (CapsoVision, Inc. Saratoga) characterized by four side cameras that offer a panoramic view of 360 degrees, instead of the front to 160°. Two recent pilot studies showed comparable safety profiles and diagnostic yield with the more standardized capsule. Namely, side vision has made possible a clear visualization of the papilla in 70% of cases. The aim of our study is to evaluate the feasibility and diagnostic yield of these two new devices, which first may allow a reduction in costs. Moreover, their complementary use could lead to a recovery diagnostic in patients with false negative results in an initial investigation.
Resumo:
Das Institut für Kernphysik der Universität Mainz betreibt seit 1990 eine weltweit einzigartige Beschleunigeranlage für kern- und teilchenphysikalische Experimente – das Mainzer Mikrotron (MAMI-B). Diese Beschleunigerkaskade besteht aus drei Rennbahn-Mikrotrons (RTMs) mit Hochfrequenzlinearbeschleunigern bei 2.45 GHz, mit denen ein quasi kontinuierlicher Elektronenstrahl von bis zu 100 μA auf 855MeV beschleunigt werden kann.rnrnIm Jahr 1999 wurde die Umsetzung der letzten Ausbaustufe – ein Harmonisches Doppelseitiges Mikrotron (HDSM, MAMI-C) – mit einer Endenergie von 1.5 GeV begonnen. Die Planung erforderte einige mutige Schritte, z.B. Umlenkmagnete mit Feldgradient und ihren daraus resultierenden strahloptischen Eigenschaften, die einen großen Einfluss auf die Longitudinaldynamik des Beschleunigers haben. Dies erforderte die Einführung der „harmonischen“ Betriebsweise mit zwei Frequenzen der zwei Linearbeschleuniger.rnrnViele Maschinenparameter (wie z.B. HF-Amplituden oder -Phasen) wirken direkt auf den Beschleunigungsprozess ein, ihre physikalischen Größen sind indes nicht immer auf einfache Weise messtechnisch zugänglich. Bei einem RTM mit einer verhältnismäßig einfachen und wohldefinierten Strahldynamik ist das im Routinebetrieb unproblematisch, beim HDSM hingegen ist schon allein wegen der größeren Zahl an Parametern die Kenntnis der physikalischen Größen von deutlich größerer Bedeutung. Es gelang im Rahmen dieser Arbeit, geeignete Methoden der Strahldiagnose zu entwickeln, mit denen diese Maschinenparameter überprüft und mit den Planungsvorgaben verglichen werden können.rnrnDa die Anpassung des Maschinenmodells an eine einzelne Phasenmessung aufgrund der unvermeidlichen Messfehler nicht immer eindeutige Ergebnisse liefert, wird eine Form der Tomographie verwendet. Der longitudinale Phasenraum wird dann in Form einer Akzeptanzmessung untersucht. Anschließend kann ein erweitertes Modell an die gewonnene Datenvielfalt angepasst werden, wodurch eine größere Signifikanz der Modellparameter erreicht wird.rnrnDie Ergebnisse dieser Untersuchungen zeigen, dass sich der Beschleuniger als Gesamtsystem im Wesentlichen wie vorhergesagt verhält und eine große Zahl unterschiedlicher Konfigurationen zum Strahlbetrieb möglich sind – im Routinebetrieb wird dies jedoch vermieden und eine bewährte Konfiguration für die meisten Situationen eingesetzt. Das führt zu einer guten Reproduzierbarkeit z.B. der Endenergie oder des Spinpolarisationswinkels an den Experimentierplätzen.rnrnDie Erkenntnisse aus diesen Untersuchungen wurden teilweise automatisiert, so dass nun den Operateuren zusätzliche und hilfreiche Diagnose zur Verfügung steht, mit denen der Maschinenbetrieb noch zuverlässiger durchgeführt werden kann.
Resumo:
The first part of this essay aims at investigating the already available and promising technologies for the biogas and bio-hydrogen production from anaerobic digestion of different organic substrates. One strives to show all the peculiarities of this complicate process, such as continuity, number of stages, moisture, biomass preservation and rate of feeding. The main outcome of this part is the awareness of the huge amount of reactor configurations, each of which suitable for a few types of substrate and circumstance. Among the most remarkable results, one may consider first of all the wet continuous stirred tank reactors (CSTR), right to face the high waste production rate in urbanised and industrialised areas. Then, there is the up-flow anaerobic sludge blanket reactor (UASB), aimed at the biomass preservation in case of highly heterogeneous feedstock, which can also be treated in a wise co-digestion scheme. On the other hand, smaller and scattered rural realities can be served by either wet low-rate digesters for homogeneous agricultural by-products (e.g. fixed-dome) or the cheap dry batch reactors for lignocellulose waste and energy crops (e.g. hybrid batch-UASB). The biological and technical aspects raised during the first chapters are later supported with bibliographic research on the important and multifarious large-scale applications the products of the anaerobic digestion may have. After the upgrading techniques, particular care was devoted to their importance as biofuels, highlighting a further and more flexible solution consisting in the reforming to syngas. Then, one shows the electricity generation and the associated heat conversion, stressing on the high potential of fuel cells (FC) as electricity converters. Last but not least, both the use as vehicle fuel and the injection into the gas pipes are considered as promising applications. The consideration of the still important issues of the bio-hydrogen management (e.g. storage and delivery) may lead to the conclusion that it would be far more challenging to implement than bio-methane, which can potentially “inherit” the assets of the similar fossil natural gas. Thanks to the gathered knowledge, one devotes a chapter to the energetic and financial study of a hybrid power system supplied by biogas and made of different pieces of equipment (natural gas thermocatalitic unit, molten carbonate fuel cell and combined-cycle gas turbine structure). A parallel analysis on a bio-methane-fed CCGT system is carried out in order to compare the two solutions. Both studies show that the apparent inconvenience of the hybrid system actually emphasises the importance of extending the computations to a broader reality, i.e. the upstream processes for the biofuel production and the environmental/social drawbacks due to fossil-derived emissions. Thanks to this “boundary widening”, one can realise the hidden benefits of the hybrid over the CCGT system.
Resumo:
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.
Resumo:
To evaluate, in a prospective pilot study, the feasibility of identifying pathogens in urine using real-time polymerase chain reaction (PCR), and to compare the results with the conventional urine culture-based procedures.
Resumo:
To prospectively evaluate a 3-dimensional spoiled gradient-dual-echo (3D SPGR-DE) magnetic resonance imaging (MRI) sequence for the qualitative and quantitative analysis of liver fat content (LFC) in patients with the suspicion of fatty liver disease using histopathology as the standard of reference.
Resumo:
Malignant rhabdoid tumor (MRT) of the liver is a rare malignancy with grave prognosis. This entity should be considered in the differential diagnosis of any aggressive liver tumor with low levels of alpha fetoprotein. We report 2 cases of hepatic MRT presenting in infancy. In these 2 cases, we show that loss of INI1 facilitates making the correct diagnosis of primary hepatic MRT utilizing BAF 47 (INI1 gene product) immunostains. Difficulty encountered in making this rare diagnosis, including the need for repeated biopsies, can be avoided if MRT is considered in the differential diagnosis early on and BAF 47 immunohistochemistry is ordered.
Resumo:
We hypothesized that bone SPECT combined with multiplanar reconstructed CT can identify and target the pain-inducing focus in the foot and can be used to successfully guide anaesthetic infiltrations. Therefore we prospectively investigated feasibility and predictive value of bone SPECT/CT for image guided diagnostic infiltrations in patients with chronic foot pain.
Resumo:
High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
Despite a growing number of identified genetic causes of monogenetic disorders, early molecular testing is rarely applied in daily nephrologic practice. In selected cases and to answer specific questions, molecular testing however can be helpful for the specialist. The future significance of genetic testing most likely lies in the area of individual risk profiling for polygenetic disorders. The basis for this testing however has yet to be established.