994 resultados para Coupled Method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical methodology for the simultaneous determination of seven pharmaceuticals and two metabolites belonging to the non-steroidal anti-inflammatory drugs (NSAIDs) and analgesics therapeutic groups was developed based on off-line solid-phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry (SPE–UHPLC–MS/MS). Extraction conditions were optimized taking into account parameters like sorbent material, sample volume and sample pH. Method detection limits (MDLs) ranging from 0.02 to 8.18 ng/L were obtained. This methodology was successfully applied to the determination of the selected pharmaceuticals in seawater samples of Atlantic Ocean in the Northern Portuguese coast. All the pharmaceuticals have been detected in the seawater samples, with pharmaceuticals like ibuprofen, acetaminophen, ketoprofen and the metabolite hydroxyibuprofen being the most frequently detected at concentrations that can reach some hundreds of ng/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty Candida albicans isolated from oral candidosis patients and 30 C. albicans isolated from control individuals were studied. In vitro susceptibility tests were performed for amphotericin B, fluconazole, 5-flucytosine and itraconazole through the Clinical and Laboratorial Standards Institute (CLSI) reference method and E test system. The results obtained were analyzed and compared. MIC values were similar for the strains isolated from oral candidosis patients and control individuals. The agreement rate for the two methods was 66.67% for amphotericin B, 53.33% for fluconazole, 65% for flucytosine and 45% for itraconazole. According to our data, E test method could be an alternative to trial routine susceptibility testing due to its simplicity. However, it can not be considered a substitute for the CLSI reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the new KDIGO (Kidney Disease Improving Global Outcomes) guidelines, the term of renal osteodystrophy, should be used exclusively in reference to the invasive diagnosis of bone abnormalities. Due to the low sensitivity and specificity of biochemical serum markers of bone remodelling,the performance of bone biopsies is highly stimulated in dialysis patients and after kidney transplantation. The tartrate-resistant acid phosphatase (TRACP) is an iso-enzyme of the group of acid phosphatases, which is highly expressed by activated osteoclasts and macrophages. TRACP in osteoclasts is in intracytoplasmic vesicles that transport the products of bone matrix degradation. Being present in activated osteoclasts, the identification of this enzyme by histochemistry in undecalcified bone biopsies is an excellent method to quantify the resorption of bone. Since it is an enzymatic histochemical method for a thermolabile enzyme, the temperature at which it is performed is particularly relevant. This study aimed to determine the optimal temperature for identification of TRACP in activated osteoclasts in undecalcified bone biopsies embedded in methylmethacrylate. We selected 10 cases of undecalcified bone biopsies from hemodialysis patients with the diagnosis of secondary hyperparathyroidism. Sections of 5 μm were stained to identify TRACP at different incubation temperatures (37º, 45º, 60º, 70º and 80ºC) for 30 minutes. Activated osteoclasts stained red and trabecular bone (mineralized bone) was contrasted with toluidine blue. This approach also increased the visibility of the trabecular bone resorption areas (Howship lacunae). Unlike what is suggested in the literature and in several international protocols, we found that the best results were obtained with temperatures between 60ºC and 70ºC. For technical reasons and according to the results of the present study, we recommended that, for an incubation time of 30 minutes, the reaction should be carried out at 60ºC. As active osteoclasts are usually scarce in a bone section, the standardization of the histochemistry method is of great relevance, to optimize the identification of these cells and increase the accuracy of the histomosphometric results. Our results, allowing an increase in osteoclasts contrast, also support the use of semi-automatic histomorphometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antifungal activities of fluconazole, itraconazole, ketoconazole, terbinafine and griseofulvin were tested by broth microdilution technique, against 60 dermatophytes isolated from nail or skin specimens from Goiania city patients, Brazil. In this study, the microtiter plates were incubated at 28 ºC allowing a reading of the minimal inhibitory concentration (MIC) after four days of incubation for Trichophyton mentagrophytes and five days for T. rubrum and Microsporum canis. Most of the dermatophytes had uniform patterns of susceptibility to the antifungal agents tested. Low MIC values as 0.03 µg/mL were found for 33.3%, 31.6% and 15% of isolates for itraconazole, ketoconazole and terbinafine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new iterative algorithm based on the inexact-restoration (IR) approach combined with the filter strategy to solve nonlinear constrained optimization problems is presented. The high level algorithm is suggested by Gonzaga et al. (SIAM J. Optim. 14:646–669, 2003) but not yet implement—the internal algorithms are not proposed. The filter, a new concept introduced by Fletcher and Leyffer (Math. Program. Ser. A 91:239–269, 2002), replaces the merit function avoiding the penalty parameter estimation and the difficulties related to the nondifferentiability. In the IR approach two independent phases are performed in each iteration, the feasibility and the optimality phases. The line search filter is combined with the first one phase to generate a “more feasible” point, and then it is used in the optimality phase to reach an “optimal” point. Numerical experiences with a collection of AMPL problems and a performance comparison with IPOPT are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal parasites are an important cause of morbidity and mortality. Immunocompromised individuals may develop more severe forms of these infections. Taking into account the immunity impairment in patients suffering from chronic renal failure (CRF), we will determine the prevalence and associated symptoms of intestinal parasites in these patients. Controls without CRF were used for comparison. Stool samples were collected and processed for microscopic identification of parasites using the Formalin-ether concentration method. For Cryptosporidium diagnosis, the ELISA technique was used. One hundred and ten fecal samples from hemodialysis patients were analyzed, as well as 86 from a community group used as control group. A result of 51.6% of intestinal parasites was observed in hemodialysis patients and 61.6% in the control group. Cryptosporidium and Blastocystis were the most common infections in patients with CRF (26.4% and 24.5%, respectively). Blastocystis was the most common infection in the control group (41.9%), however no individual was found positive for Cryptosporidium. Among the CRF patients, 73.6% were symptomatic, 54.3% of these tested positive for at least one parasite, in contrast to 44.8% in asymptomatic patients (p = 0.38). The most common symptoms in this group were flatulence (36.4%), asthenia (30.0%) and weight loss (30.0%). In the control group, 91.9% were symptomatic, 60.8% of these tested positive for at least one parasite, in contrast to 71.4% in asymptomatic patients (p = 0.703). A significant difference between the two groups was observed with regard to symptoms, with bloating, postprandial fullness, and abdominal pain being more frequent in the control group than in the hemodialysis group (all p < 0.05). Comparing symptomatic with asymptomatic, there was no association in either group between symptoms or the prevalence of parasitic infection, nor with the type of parasite or with multiple parasitic infections. Patients with chronic renal failure are frequent targets for renal transplantation, which as well as the inherent immunological impairment of the disease itself, results in immunosuppression by medication. For this reason, carriers of intestinal parasites with pathogenic potential can develop serious clinical complications influencing the success of transplantation. This fact, coupled with the high prevalence of intestinal parasites and the dissociation between symptoms and infection in CRF patients, suggests that the stool test should be incorporated in routine propedeutics. Furthermore, preventive measures for the acquisition of parasites through the fecal-oral contamination route should be introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A contínua subida dos preços dos combustíveis fósseis tradicionais aliada à crescente pressão por parte de várias instituições mundiais para uma política “verde” no que diz respeito aos combustíveis, levam a um aumento da procura dos biocombustíveis e é neste contexto que surge o biodiesel como um dos principais intervenientes. O biodiesel pode ser definido como um derivado éster monoalquílico de ácidos gordos de cadeia longa proveniente de fontes renováveis como óleos vegetais ou gorduras animais e que apresenta características semelhantes ao diesel de petróleo, podendo ser utilizado sem qualquer problema em motores de ignição por compressão. Este trabalho apresenta como principal objetivo o estudo da aplicação da tecnologia de ultrassons na produção de biodiesel. Foi utilizado neste trabalho como matéria-prima um óleo doméstico usado. Este óleo foi previamente filtrado sendo depois analisado o seu índice de acidez para avaliar o seu teor em ácidos gordos livres. O valor obtido para o índice de acidez do óleo foi de 1,91 mg KOH/g, um valor relativamente baixo permitindo a sua utilização sem ser necessário um tratamento inicial via esterificação para diminuir a acidez do mesmo. Foram realizados três ensaios de reação independentes, o primeiro recorrendo ao método tradicional de produção de biodiesel através de transesterificação e recorrendo a agitação mecânica e aquecimento, o segundo utilizando uma sonda de ultrassons com a potência de 500 W e um terceiro ensaio de reação utilizando uma sonda de ultrassons de 2000 W. Em todas as reações foi utilizada uma proporção de 1:5 de óleo usado e metanol e 0,5 % (em relação á massa de óleo utilizada) de catalisador metilato de sódio. Todas as alíquotas recolhidas durante os ensaios foram analisadas através de cromatografia gasosa de modo a determinar o conteúdo em ésteres presente em cada uma delas. A reação convencional teve uma duração total de 150 minutos e decorreu a uma temperatura de 65ºC e a agitação constante de 500 rpm. Ao longo da reação foram retiradas alíquotas de cerca de 25 ml, que foram tratadas de imediato e posteriormente analisadas de modo a estudar-se o comportamento da reação ao longo do tempo. A percentagem de ésteres metílicos no biodiesel obtida ao fim de 90 minutos foi de 81,3%. Em seguida realizou-se uma reação utilizando uma sonda de ultrassons de 500 W de potência mergulhada num recipiente reacional devidamente isolado com uma rolha de cortiça de modo a minimizar as perdas de metanol por evaporação. O tempo total de reação foi de 90 minutos e foram-se retirando alíquotas de cerca de 25 ml para acompanhar o desenrolar da reação, tendo-se obtido uma percentagem de ésteres metílicos de 85,9% ao fim dos 90 minutos. Foi realizada por fim um terceiro ensaio de reação utilizando uma sonda de 2000 W com uma duração total de 90 minutos, tendo-se obtido resultados pouco satisfatórios (77,7%), provavelmente devido a algum problema operacional relacionado com a sonda de ultrassons utilizada ou devido a uma geometria do reator pouco eficiente. Os produtos resultantes da reação convencional e da reação utilizando a sonda de ultrassons de 500 W, assim como o óleo utilizado como matéria-prima foram caracterizados em termos de índice de acidez, densidade a 15ºC e viscosidade a 40ºC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Qualquer estrutura hoje em dia deve ser resistente, robusta e leve, o que aumentou o interesse industrial e investigação nas ligações adesivas, nomeadamente pela melhoria das propriedades de resistência e fratura dos materiais. Com esta técnica de união, o projeto de estruturas pode ser orientado para estruturas mais leves, não só em relação à economia direta de peso relativamente às juntas aparafusas ou soldadas, mas também por causa da flexibilidade para ligar materiais diferentes. Em qualquer área da indústria, a aplicação em larga escala de uma determinada técnica de ligação supõe que estão disponíveis ferramentas confiáveis para o projeto e previsão da rotura. Neste âmbito, Modelos de Dano Coesivo (MDC) são uma ferramenta essencial, embora seja necessário estimar as leis MDC do adesivo à tração e corte para entrada nos modelos numéricos. Este trabalho avalia o valor da tenacidade ao corte (GIIC) de juntas coladas para três adesivos com ductilidade distinta. O trabalho experimental consiste na caracterização à fratura ao corte da ligação adesiva por métodos convencionais e pelo Integral-J. Além disso, pelo integral-J, é possível definir a forma exata da lei coesiva. Para o integral-J, é utilizado um método de correlação de imagem digital anteriormente desenvolvido para a avaliação do deslocamento ao corte do adesivo na extremidade da fenda (δs) durante o ensaio, acoplado a uma sub-rotina em Matlab® para a extração automática de δs. É também apresentado um trabalho numérico para avaliar a adequabilidade de leis coesivas triangulares aproximadas em reproduzir as curvas força-deslocamento (P-δ) experimentais dos ensaios ENF. Também se apresenta uma análise de sensibilidade para compreender a influência dos parâmetros coesivos nas previsões numéricas. Como resultado deste trabalho, foram estimadas experimentalmente as leis coesivas de cada adesivo pelo método direto, e numericamente validadas, para posterior previsão de resistência em juntas adesivas. Em conjunto com a caraterização à tração destes adesivos, é possível a previsão da rotura em modo-misto.